AirGreen × GENERAL AIRSTAGE
Sold and installed by AirGreen.
Montreal, Laval, Longueuil, the North Shore and the South Shore.
GENERAL AIRSTAGE // 3 zones
GENERAL 3-zone heat pump: the third head often decides the unit
10 three-head listings, on ten GENERAL multi-zone outdoor units: five R-32 Aquila and Aquila XLTH units, and five R-410A RLXFZ and RLXFZH units, also available. On the 24,000 units the third head stays at 9,000 BTU or less; beyond that, a unit of 36,000 or more is needed.
The tool // The third head
Three heads, ten outdoor units: which say yes?
The tool opens on 9,000 + 9,000 + 12,000, that is 30,000 BTU: the 24,000 and 36,000 Aquila units pass, the 24,000 R-410A units do not. Set room 1 to 12,000: the 24,000 Aquila units drop out too.
Total capacity 30,000 BTU
Aquila AOUH24KWAS3
R-32 · published limit −15 °C · accepted total 14,000 to 31,000 BTU
Largest head per port: A 18,000 · B 15,000 · C 9,000
Within the manual's rulesNotoo many heads for this unittotal under the accepted minimumtotal over the accepted maximuma head too big for its portcombination not on GENERAL's listAquila AOUH36KWAS4
R-32 · published limit −15 °C · accepted total 25,000 to 46,000 BTU
Largest head per port: A 24,000 · B 18,000 · C 15,000 · D 9,000
Within the manual's rulesNotoo many heads for this unittotal under the accepted minimumtotal over the accepted maximuma head too big for its portcombination not on GENERAL's listAquila AOUH45KWAS5
R-32 · published limit −15 °C · accepted total 34,000 to 58,000 BTU
Largest head per port: A 24,000 · B 24,000 · C 18,000 · D 12,000 · E 9,000
Within the manual's rulesNotoo many heads for this unittotal under the accepted minimumtotal over the accepted maximuma head too big for its portcombination not on GENERAL's listAquila XLTH AOUH24KWAH3
R-32 · published limit −26 °C · accepted total 14,000 to 31,000 BTU
Largest head per port: A 18,000 · B 15,000 · C 9,000
Within the manual's rulesNotoo many heads for this unittotal under the accepted minimumtotal over the accepted maximuma head too big for its portcombination not on GENERAL's listAquila XLTH AOUH36KWAH4
R-32 · published limit −26 °C · accepted total 25,000 to 46,000 BTU
Largest head per port: A 24,000 · B 18,000 · C 15,000 · D 9,000
Within the manual's rulesNotoo many heads for this unittotal under the accepted minimumtotal over the accepted maximuma head too big for its portcombination not on GENERAL's listRLXFZ AOU24RLXFZ
R-410A · published limit −15 °C · accepted total 14,000 to 27,000 BTU
5 three-room combinations listed by GENERAL (manual 9374747146, p. En-3)
On GENERAL's list, no. Notoo many heads for this unittotal under the accepted minimumtotal over the accepted maximuma head too big for its portcombination not on GENERAL's listRLXFZ AOU36RLXFZ1
R-410A · published limit −15 °C · accepted total 27,000 to 39,000 BTU
18 three-room combinations listed by GENERAL (manual 9374747153, p. En-3)
On GENERAL's list, no. 4Notoo many heads for this unittotal under the accepted minimumtotal over the accepted maximuma head too big for its portcombination not on GENERAL's listRLXFZ AOU45RLXFZ
R-410A · published limit −15 °C · accepted total 34,000 to 54,000 BTU
34 three-room combinations listed by GENERAL (manual 9380545101-06, p. En-4 and En-5)
On GENERAL's list, no. Notoo many heads for this unittotal under the accepted minimumtotal over the accepted maximuma head too big for its portcombination not on GENERAL's listRLXFZH AOU24RLXFZH
R-410A · published limit −26 °C · accepted total 14,000 to 27,000 BTU
5 three-room combinations listed by GENERAL (manual 9374747153, p. En-4)
On GENERAL's list, no. Notoo many heads for this unittotal under the accepted minimumtotal over the accepted maximuma head too big for its portcombination not on GENERAL's listRLXFZH AOU36RLXFZH
R-410A · published limit −26 °C · accepted total 27,000 to 39,000 BTU
18 three-room combinations listed by GENERAL (manual 9380545101-06, p. En-5)
On GENERAL's list, no. 8Notoo many heads for this unittotal under the accepted minimumtotal over the accepted maximuma head too big for its portcombination not on GENERAL's list
With three heads, the tool applies to the 5 Aquila and Aquila XLTH units their per-port limits and accepted total (manuals 9300793117-03 and 9379113397-02), then looks for your trio among the 80 three-room combinations of the 5 RLXFZ and RLXFZH units (manuals 9374747146, 9374747153 and 9380545101-06).
The 10 3-zone listings online
Price by quote.
GENERAL // Did you know
Three GENERAL details that matter for three rooms
Did you know · Port C
What does the third port of the 24,000 Aquila take?
Did you know · The line set
Same nominal size, same ports: besides the −26 °C limit, what changes on the 24,000 Aquila XLTH?
Did you know · The list
How many three-room combinations on the 24,000 R-410A units?
LogisVert
LogisVert for three rooms
Of the ten units that take three rooms, the five R-32 Aquila and Aquila XLTH units have a Canadian ENERGY STAR certification and may be eligible for LogisVert, as may three of the five R-410A units. The other two, the 36,000 and 45,000 RLXFZ, have no Canadian ENERGY STAR certification, and the LogisVert guide v1.10 (September 15, 2026) makes that a condition. The guide sets $120 per 1,000 BTU/h of heating at −8 °C with the cold-climate mention, $50 without.
Indicative amounts by outdoor unit: Aquila AOUH24KWAS3: $1,872; Aquila AOUH36KWAS4: $1,180; Aquila AOUH45KWAS5: $3,720; Aquila XLTH AOUH24KWAH3: $1,944; Aquila XLTH AOUH36KWAH4: $2,928; RLXFZ AOU24RLXFZ: $705; RLXFZ AOU36RLXFZ1: $0 (not on the Canadian ENERGY STAR list); RLXFZ AOU45RLXFZ: $0 (not on the Canadian ENERGY STAR list); RLXFZH AOU24RLXFZH: $1,848; RLXFZH AOU36RLXFZH: $2,568. The NEEP registry lists these certified combinations as all non-ducted multi-zones, except the 24,000 RLXFZ's, listed with ENERGY STAR only; if one of the three heads is ducted, the amount may change.
These are indicative amounts. Only Hydro-Québec confirms the assistance granted.
Questions
What people ask us about 3-zone systems
Which GENERAL units serve three rooms?
In multi-zone, ten of the outdoor units we offer: the 24,000 and 36,000 Aquila and Aquila XLTH, the 45,000 Aquila, the 24,000, 36,000 and 45,000 RLXFZ, and the 24,000 and 36,000 RLXFZH. The 18,000 units stop at two rooms. The J-7S mini-VRF, with its own VRF indoor units, also accepts three: its 2-ton goes up to five, its 3- and 4-ton up to nine and twelve.
Do the 24,000 Aquila units take 9,000 + 9,000 + 12,000?
Yes: the total, 30,000 BTU, stays under the 31,000 BTU they accept, and the 12,000 head goes on port A. On the R-410A side, the 24,000 RLXFZ and RLXFZH turn this trio down, as they stop at 27,000 BTU.
An 18,000 head among three, on a 24,000 unit?
No: on the 24,000 Aquila units, 18,000 + 7,000 + 7,000 makes 32,000 BTU, over the 31,000 accepted, and the 24,000 RLXFZ and RLXFZH take no head over 12,000 for three rooms. A 36,000 unit is needed: the two Aquila units, the RLXFZ (no. 14) and the RLXFZH (no. 18) at 36,000 accept this trio.
Do the three heads have to be the same size?
No: each room gets the size that suits it, and we set it on site, room by room. Only then do the three sizes, taken together, have to form a combination the outdoor unit accepts.
Three rooms on one outdoor unit, installed by AirGreen.
We come and see the three rooms and measure each line route, then give you the AHRI number and indicative LogisVert amount of the system you choose.
Sold and installed by AirGreen.
Compare the multi-zone families · See 2 zones · See 4 zones · The J-7S mini-VRF
Sources
Where the numbers come from
- GENERAL, 24KWAS3 (20250618A), 36KWAS4 (20250619A), 45KWAS5 (20250618A), 24KWAH3 (20250618A) and 36KWAH4 (20250619A) submittals.
- GENERAL, Aquila installation manuals, ref. 9300793117-03 and 9379113397-02: number of indoor units, accepted total capacity and size per port (three-room combinations).
- GENERAL, RLXFZ and RLXFZH installation manuals, ref. 9374747146, 9374747153 and 9380545101-06: numbered lists of three-room combinations, read November 5, 2026.
- GENERAL, RLXFZ and RLXFZH submittals (three-room combinations): 24RLXFZ, 36RLXFZ1, 45RLXFZ and 36RLXFZH, effective January 10, 2023; 24RLXFZH, October 22, 2019.
- On the 24,000 RLXFZH, the 2019 submittal stops at 21,000 BTU/h, but manual 9374747153 (p. En-3 and En-4) goes up to 27,000 BTU and lists 9,000 + 9,000 + 9,000: the page follows the manual.
- NEEP listings 385699, 385701, 438660, 438666, 455167, 455169 and 455170, checked November 5, 2026.
- ENERGY STAR, Canadian market, records 2409925, 2409928, 2409935, 3627392, 3627394, 3627398, 3630082 and 3630083, checked November 5, 2026.
- Hydro-Québec, LogisVert participation guide, residential customers, version 1.10, September 15, 2026, p. 14-15.
- airgreen.ca product pages, read November 5, 2026.
Page updated November 5, 2026. Indicative LogisVert amounts: only Hydro-Québec confirms the assistance granted. Price by quote.