GE Zoneline · PTAC · updated October 13, 2026
GE Zoneline PTAC units in Montreal: your wall outlet picks the heater
Three R-454B Zoneline heat pumps — 9,000, 12,000 and 15,000 BTU — that slide into the standard 42 × 16 in sleeve. At GE, back-up heat comes from a power cord kit: the outlet already in your wall, 6-15, 6-20 or 6-30, sets the heater at 2.4, 3.4 or 4.8 kW.
Which outlet do you see under the window?
Drawing after GE’s cord-kit table; output at 230 V.
- 3 sizes
- 9,000 to 15,000 BTU
- 42 × 16 in
- standard RAB42MG sleeve
- −4 °C
- heat pump, then heater
- R-454B
- AZHS refrigerant
01 · Replacement
Find my Zoneline in 4 answers
Four things you can check yourself: the outlet, the building’s voltage, the size of the room and the outside grille. The answer comes straight from GE’s spec sheets.
1 · The outlet
2 · The building’s voltage
4 · The outside grille
Recognizing your outlet
15 A · 2.4 kW
20 A · 3.4 kW
30 A · 4.8 kW
Slots after GE’s description (tandem, perpendicular, large tandem).
AirGreen × GE Zoneline
GE’s machine, a local install.
GE Appliances designs the Zoneline and its kits. AirGreen picks the right model and the right kit for your outlet with you, then installs it. Each does what it does best.
What GE brings
- Three R-454B Zoneline units9,000, 12,000 and 15,000 BTU fixed-speed heat pumps. The 12,000 and 15,000 are AHRI certified.
- The power cord kitThe back-up heater follows the outlet: 2.4, 3.4 or 4.8 kW at 230 V.
- The standard sleeveThe 42 × 16 in RAB42MG, and the RAK40 deflector for another brand’s grille.
- Corrosion protectionThe “C” in the model number, standard on the AZHS.
What AirGreen brings
- Sold and installed by AirGreenIn Montreal, Laval, Longueuil, the South Shore and the North Shore.
- Free quotationSend the room size, a photo of the outlet and one of the grille.
- 10 published GE installationsZoneline PTAC units in Montérégie, from August to October 2026.
- RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16.
The result: the right Zoneline and the right kit for your outlet, installed by AirGreen.
02 · GE’s numbers
The three Zoneline units, side by side
Many buildings run on 208 V: GE publishes both columns, so we show you both.
| Measure | 9,000 BTUAZHS09DCXXA |
12,000 BTUAZHS12DCXXA |
15,000 BTUAZHS15DCXXA |
|---|---|---|---|
| Cooling | 9,700 BTU/h | 12,100 BTU/h | 15,100 BTU/h |
| Heating, heat pump | 8,000 BTU/h | 10,600 BTU/h | 13,500 BTU/h |
| EER | 12.4 | 11.6 | 10.4 |
| COP (8 °C rating) | 3.7 | 3.6 | 3.3 |
| Power in heat-pump mode | 625 W | 855 W | 1,180 W |
| Largest heater (RAK330P) | 4.8 kW | 4.8 kW | 4.8 kW |
| Dehumidification | 2.0 pints/h | 3.1 pints/h | 4.1 pints/h |
| Airflow (low/high) | 290 / 400 cfm | 335 / 440 cfm | 330 / 495 cfm |
| Room (AirGreen estimate) | 130–195 sq ft | 170–255 sq ft | 235–350 sq ft |
| AHRI | not found online | 215399516 | 215406392 |
Sources: GE “Specification Revised 2/24” sheets, GE brochure 27-D0107-24 (measured watts), AHRI certificates. For the 12,000 at 230 V, GE’s sheet says 12,000 BTU/h and the AHRI certificate 12,100: we show the certified value.
03 · Heating
Heat pump first, heater second
GE runs the AZHS heat pump down to 25 °F (−4 °C) outside, with reverse-cycle defrost. Colder than that, the cord kit’s heater takes over. Slide the temperature to see what heats.
Model
Kit (by outlet)
04 · Installation
The sleeve, the grille and the kits
A Zoneline is ordered with its kits. Here are the ones GE provides, and what each one does.

The wall sleeve
42 × 16 in, 13 ¾ in deep; also 16, 18, 20 and 24 in. The chassis is 20 13/16 in deep.
The deflector
Adapts the Zoneline to an outside grille that isn’t GE’s.
The cord that sets the heater
RAK315P, RAK320P or RAK330P: 2.4, 3.4 or 4.8 kW at 230 V, on a 6-15, 6-20 or 6-30 outlet.
The acoustic sleeve
GE says the RAB42MGSTC raises the Zoneline’s rating to STC 31. GE publishes no sound level in dB.
The fresh-air vent
Brings in outdoor air. GE gives two different airflows depending on the document: we confirm it on quotation.
The corrosion protection
The “C” in AZHS…DCXXA: corrosion treatment as standard, per GE’s model-number key.
Reading AZHS12DCXXA (letters per GE’s key)
- Aair conditioner
- ZZoneline
- Hheat pump, fixed speed
- Sstandard
- 1212,000 BTU nominal
- D230/208 V heater
- Ccorrosion protection
- Xno UV-C
- Xno onboard Wi-Fi
- Aseries A
05 · Grants and certifications
The straight answer before the quotation
LogisVert
Not eligible
Hydro-Québec’s guide (v1.10, Sept. 15, 2026) covers ENERGY STAR split and mini-split heat pumps with an outdoor unit of at least 12,000 BTU/h. A PTAC is a single package, and no AZHS appears in Hydro-Québec’s list of October 13, 2026.
ENERGY STAR
No category
ENERGY STAR has no specification in force for PTACs: the PTHP heat pump one (v1.0) remained a draft, paused according to the EPA (December 2025).
AHRI
Certified
12,000: certificate 215399516 · 15,000: certificate 215406392 (rated as PTHP, packaged terminal heat pump). The 9,000’s certificate isn’t published online.
Why say it? Because a PTAC is often weighed against a wall heat pump, which can qualify for LogisVert. If the grant matters for your project, ask us for both options in the same quotation.
06 · Our installations
10 published GE installations
Articles from our “Nos réalisations” blog on GE Zoneline PTAC units, all in Montérégie, published from August 4 to October 5, 2026.
By month of publication
- October 5, 2026Saint-HyacintheUnder a window
- September 23, 2026UptonUnder a window
- September 20, 2026YamaskaUnder a window
- September 18, 2026Saint-DamaseUnder a large window
- September 15, 2026Saint-Barnabé-SudIn the existing wall sleeve
- September 10, 2026MassuevilleUnder a large window
- September 5, 2026Saint-RobertUnder a large window
- August 29, 2026Saint-Roch-de-RichelieuUnder a large window
- August 25, 2026Saint-AiméBedroom with existing baseboard
- August 4, 2026Saint-LiboireUnder a window, existing baseboard
07 · FAQ
Your Zoneline questions
Which Zoneline size for my room?
By our estimate (GE publishes no square-foot range): the 9,000 for about 130 to 195 sq ft, the 12,000 for 170 to 255 sq ft, the 15,000 for 235 to 350 sq ft. Insulation, windows and orientation can change the choice.
My outlet is a 6-20: which heater will I get?
The RAK320P kit: 3.4 kW at 230 V or 2.78 kW at 208 V, on a 20 A circuit. With a 6-15, it’s the RAK315P (2.4 kW); with a 6-30, the RAK330P (4.8 kW).
Does the Zoneline heat in a Montréal winter?
Yes, in two stages: the heat pump down to −4 °C outside, then the cord kit’s heater. In deep cold, the heater does the work, like a baseboard.
208 V or 230 V: what changes?
A little less output at 208 V. For example, the 4.8 kW heater gives 3.93 kW at 208 V, and the 15,000 cools at 14,700 BTU/h instead of 15,100.
Will the Zoneline fit my current sleeve?
It’s built for the 42 × 16 in sleeve (RAB42MG at GE). If the outside grille isn’t GE’s, GE provides the RAK40 deflector. The sleeve and grille are checked before ordering.
Are GE PTAC units eligible for LogisVert?
No. LogisVert covers ENERGY STAR split and mini-split heat pumps with an outdoor unit; no AZHS Zoneline is in Hydro-Québec’s list of October 13, 2026.
Are they ENERGY STAR certified?
No: ENERGY STAR has no category in force for PTACs. They are AHRI certified, though (12,000 and 15,000).
Which refrigerant?
R-454B, per GE’s AZHS spec sheets.
Can I control it over Wi-Fi?
GE’s documents disagree: the AZHS model key says “no onboard Wi-Fi”, and the brochure lists a SmartHQ module (SHCM10PK) sold separately. We confirm it on quotation.
What is the warranty?
GE publishes the Zoneline warranty for the United States; the terms that apply in Québec are confirmed on quotation.
Does it dehumidify?
Yes, in cooling mode: 2.0, 3.1 and 4.1 pints per hour for the 9,000, 12,000 and 15,000, according to GE.
Is it noisy?
GE publishes no sound level in dB for these models. It mentions a sound barrier and an acoustic sleeve (RAB42MGSTC) that raises the rating to STC 31.
How much is an installed Zoneline?
The price is on quotation, and the quotation is free. It depends on the model, the kit, and the sleeve and grille in place.
No question matches. Call us at 514 316-2973.
AirGreen Climatisation & Chauffage
Your Zoneline, priced on quotation
The room size, a photo of the outlet and a photo of the grille: that’s what it takes to pick the right model and the right kit.
- RBQ 5645-9605-01 (subclasses 15.8, 15.10 and 16)
- Showroom: 1370 rue Joliot-Curie, unit 712, Boucherville
- Office: 4951 Sainte-Catherine Street East, Montréal
- Mon–Thu 8 a.m.–6 p.m. · Fri 8 a.m.–4 p.m.
Sources (checked October 13, 2026)
- GE Appliances, “GE Zoneline Heat Pump Unit with Corrosion Protection, 230/208 Volt” sheets AZHS09DCXXA, AZHS12DCXXA, AZHS15DCXXA, “Specification Revised 2/24”.
- GE Appliances, “ZONELINE Packaged Terminal Air Conditioners” brochure, publication 27-D0107-24: model key, electrical data, kits, accessories.
- GE Appliances, Zoneline owner’s manual 49-5001038, rev. 1 (09-24).
- AHRI, certificates 215399516 (AZHS12DCXXA, issued August 5, 2026) and 215406392 (AZHS15DCXXA, issued July 20, 2026).
- Hydro-Québec, LogisVert program, residential participation guide, version 1.10 of September 15, 2026, and list of eligible heat pumps of October 13, 2026.
- ENERGY STAR (EPA), Room Air Conditioners specification v4.2 (PTAC exclusion) and draft Packaged Terminal Heat Pumps v1.0 specification (paused, December 2025).
- AirGreen, “Nos réalisations” blog, articles published as of October 13, 2026.
Price on quotation · free quotation
The GE shop
Our three Zoneline units, right below.
9,000, 12,000 and 15,000 BTU: open the product page for GE’s numbers, the kit and the sleeve. Price on quotation.