Performance R-410A: it heats down to 0 °F (-17 °C), not lower.
The manufacturer prints a 0 to 86 °F (-17 to 30 °C) outdoor heating range for the DLCERBH (2024 catalogue, p. 37). Colder than that, it is outside its range: the home’s heating has to take over. Pick a size: you see what the manufacturer prints for it.
What the manufacturer prints for each size.
Tap a size. The maximum heat at -15 °C and the efficiency are those the catalogue gives with the DLFEHBH head; our sheets pair the DLFEHAH head.
Outdoor unit size
The size is decided at the visit. Here you see what the manufacturer prints for each outdoor unit in the series.
Value printed with the DLFEHBH head. Our sheet pairs the DLFEHAH head, which the manufacturer lists as compatible; that pair is listed neither by NEEP nor by ENERGY STAR Canada.
2024 catalogue, p. 37 (outdoor unit) and p. 38 (ratings with the DLFEHBH head).
Value printed with the DLFEHBH head. Our sheet pairs the DLFEHAH head, which the manufacturer lists as compatible; that pair is listed neither by NEEP nor by ENERGY STAR Canada.
2024 catalogue, p. 37 (outdoor unit) and p. 38 (ratings with the DLFEHBH head).
Value printed with the DLFEHBH head. Our sheet pairs the DLFEHAH head, which the manufacturer lists as compatible; that pair is listed neither by NEEP nor by ENERGY STAR Canada.
2024 catalogue, p. 37 (outdoor unit) and p. 38 (ratings with the DLFEHBH head).
Value printed with the DLFEHBH head. Our sheet pairs the DLFEHAH head, which the manufacturer lists as compatible; that pair is listed neither by NEEP nor by ENERGY STAR Canada.
2024 catalogue, p. 37 (outdoor unit) and p. 38 (ratings with the DLFEHBH head).
Value printed with the DLFEHBH head. Our sheet pairs the DLFEHAH head, which the manufacturer lists as compatible; that pair is listed neither by NEEP nor by ENERGY STAR Canada.
2024 catalogue, p. 37 (outdoor unit) and p. 38 (ratings with the DLFEHBH head).
In the p. 37 table, the heating row is printed under a second “Cooling” label; its values, 0 to 86 °F (-17 to 30 °C), are the heating range. The 30,000 and 36,000 of the same series are on the wall page.
All 5 Performance wall units, right below.
Each product gives the DLCERBH outdoor unit, the DLFEHAH head and the AHRI number. Pricing by quote.
What the entry series does not do.
The three R-410A series side by side, as the manufacturer describes them. The Performance keeps the essentials: the inverter compressor, the basepan heater, the remote.
| R-410A series | Performance | QuietComfort | Deluxe |
|---|---|---|---|
| Printed heating range 2024 catalogue, pp. 37, 18, 13 | down to 0 °F (-17 °C) | down to -22 °F (-30 °C) | down to -22 °F (-30 °C) |
| “High Heat” capability brochure DLS-020-AR-01, p. 4 | No | Yes | Yes |
| Humidity control brochure DLS-020-AR-01, p. 4 | No | Yes, depending on the head | Yes |
| Occupancy sensor brochure DLS-020-AR-01, p. 4 | No | Yes | Yes |
| Wi-Fi brochure DLS-020-AR-01, p. 4 | Optional | Optional | Built in |
| ENERGY STAR ENERGY STAR Canada; 2024 catalogue, pp. 16, 12 | none of the 5 pairs on this page | select pairs | every DLCPRB pair; on our site, only the 9,000 |
| Basepan heater brochure DLS-020-AR-01, p. 4 | Yes | Yes | Yes |
Performance Series brochure DLS-020-AR-01 (May 2024), series table, p. 4; ductless catalogue DLS-001-AR-01 (March 2024). ENERGY STAR Canada certifies the Performance 30,000 with the DLFEHBH30XAK head (not cold climate); it is sold on the wall page.
The outdoor unit, size by size.
Voltage, electrical protection, piping, footprint and sound, as the 2024 catalogue prints them for the DLCERBH.
| Outdoor unit | Voltage | MCA · MOCP | Total piping · lift | Size (W × H × D) | Net weight | Sound | |
|---|---|---|---|---|---|---|---|
| DLCERBH · R-410A | |||||||
| 9,000 BTU/h DLCERBH09AAK | 208/230 V | 12 A · 15 A | 82 ft (25 m) lift 32 ft (10 m) | 30.12 × 21.85 × 11.93 in 765 × 555 × 303 mm | 55.11 lb (25.0 kg) | 55 dB(A) | |
| 12,000 BTU/h · 115 V DLCERBH12AAJ | 115 V | 18.5 A · 25 A | 82 ft (25 m) lift 32 ft (10 m) | 30.12 × 21.85 × 11.93 in 765 × 555 × 303 mm | 62.17 lb (28.2 kg) | 54 dB(A) | |
| 12,000 BTU/h DLCERBH12AAK | 208/230 V | 15 A · 15 A | 82 ft (25 m) lift 32 ft (10 m) | 30.12 × 21.85 × 11.93 in 765 × 555 × 303 mm | 59.30 lb (26.9 kg) | 56 dB(A) | |
| 18,000 BTU/h DLCERBH18AAK | 208/230 V | 15 A · 20 A | 98.4 ft (30 m) lift 65.6 ft (20 m) | 31.69 × 21.81 × 12.99 in 805 × 554 × 330 mm | 73.85 lb (33.5 kg) | 55 dB(A) | |
| 24,000 BTU/h DLCERBH24AAK | 208/230 V | 19 A · 30 A | 164 ft (50 m) lift 82 ft (25 m) | 35.04 × 26.50 × 13.46 in 890 × 673 × 342 mm | 97.88 lb (44.4 kg) | 60 dB(A) | |
Ductless catalogue DLS-001-AR-01 (March 2024), p. 37. Lift: outdoor unit above or below the head.
Three things the manufacturer’s documents tell you.
A small three-inch hole in the wall is enough.
The manufacturer writes that the head connects through a small three-inch hole: no demolition, patching or repainting.
Brochure DLS-020-AR-01, 05/2024, p. 2Basepan heater and crankcase heater, installed at the factory.
Even at entry level, the DLCERBH outdoor unit comes with both heaters as standard, useful in winter.
Catalogue DLS-001-AR-01, 03/2024, p. 36The outdoor unit detects refrigerant leaks.
Refrigerant leak detection is among the DLCERBH features, with condenser high-temperature protection.
Catalogue DLS-001-AR-01, 03/2024, p. 36What people ask us about the Performance Series.
Is it enough for a Montreal winter?
Not on its own. Its printed heating range stops at 0 °F (-17 °C). It suits a home that keeps its heating for deep cold; to heat down to -22 °F (-30 °C), look at the QuietComfort or the Deluxe. We discuss it at the visit.
Why no LogisVert amount?
None of the five pairs on this page (DLFEHAH head) is listed by NEEP or ENERGY STAR Canada, and our sheets show no amount. The Performance 30,000, sold on the wall page with the DLFEHBH30XAK head, is ENERGY STAR certified (not cold climate). Only Hydro-Québec confirms the amount granted.
115 V or 208/230 V at 12,000?
With the DLFEHBH head, the catalogue prints 6,272 BTU/h maximum at 5 °F (-15 °C) for the 115 V version and 8,000 for the 208/230 V. We check the electrical panel at the visit.
Why the DLFEHAH head on your sheets?
The manufacturer lists the DLFEHAH as compatible with the DLCERBH outdoor unit (2024 catalogue, p. 37). Its ratings with the DLCERBH are not printed: those on this page come from the DLFEHBH head.
Is Wi-Fi included?
No: it is optional on the Performance Series, per the manufacturer’s series table. We add it to the quote if you want it.
How do you choose the size?
At the visit: the room, the windows, the insulation, and what heating the house keeps for deep cold.
The entry series, where it’s enough.
We look at the room and the home’s heating, then tell you whether the Performance is enough or whether a series that heats lower is the better choice. You get a quote with the system and its AHRI number.
Sources checked on October 29, 2026
- ARCOAIRE, ductless catalogue DLS-001-AR-01 (March 2024), pp. 12-13, 16, 18 and 36 to 38: DLCERBH, ratings with the DLFEHBH head, DLFEHAH compatibility, comparison with DLCPRB and DLCSRB.
- ARCOAIRE, Performance Series brochure DLS-020-AR-01 (May 2024), pp. 2 and 4 (series table).
- NEEP and ENERGY STAR Canada, search for AHRI numbers 206384475 to 206384479: no record, read October 28, 2026.
- airgreen.ca product sheets (AHRI numbers, paired heads), re-read October 29, 2026.
LogisVert amounts are indicative. Only Hydro-Québec confirms the amount granted. Pricing by quote.