25,000
The 27,000 gives less at −15 °C than at −8.3 °C
At maximum speed, the MHMZ327 goes from 27,200 BTU/h at −8.3 °C to 25,000 BTU/h at −15 °C.
NEEP list (AHRI certificates 210605813, 210605816 and 210605819)AirGreen × CONFORTO · Multi-zone · 3 rooms
Three line lengths to check before the installation
Authorized CONFORTO dealer · sold and installed by AirGreen in Montreal, Laval, Longueuil and on the South and North Shores.
CONFORTO Maximum · multi-zone · 3 rooms
Three CONFORTO heat pumps take three heads, for a triple-zone system: the MHMZ327, the MHMZ436 and the MHMZ548. Enter your three line lengths: the page checks them against the brochure limits, works out the refrigerant to add and shows the heat at −15 °C listed by NEEP.
Updated November 5, 2026 · CONFORTO multi-zone brochure (rev. 15/05/26), MHMZ manual 615000580, NEEP, ENERGY STAR and the LogisVert guide
Multi-zone brochure
Free ports after three heads
One port is one pair of flare connections: liquid and gas. Multi-zone brochure.
This page answers
Three rooms: the 27,000, the 36,000 or the 48,000? And do your line lengths stay within the limits?
On this page
The CONFORTO shop · 3 zones
MHMZ outdoor units from the Maximum series; the heads are chosen with you. Priced by quote.
01 · The three-line check
Pick the outdoor unit, enter each line length and the height difference. The page checks the longest line, the shortest, the total and the height difference, then works out the refrigerant to add beyond the precharged length.
Outdoor unit
Length of each line, in feet
Outdoor unit position
MHMZ327 · 90 ft in total · within the limits · 2.56 oz to add See the details
Limits: CONFORTO multi-zone brochure, rev. 15/05/26, including the height limits of 15 m (outdoor unit higher) and 10 m (lower). 3 m minimum per line: our reading of MHMZ manual 615000580, which calls for at least 3 m of piping to limit vibration and noise. 1/4 in liquid line: 0.16 oz of R-410A per foot beyond the precharged length.
MHMZ327 · 3 zones
90ft of piping in total
What the check does not tell you: which heads to connect; they are chosen with you during the in-home estimate. Nor does the check cover the height between heads: 10 m at most, per the manual.
02 · Free ports
For the same number of rooms, the three units differ in precharged length, maximum lengths and free ports. Those values come from the brochure; the minimum circuit ampacity and the LogisVert amount come from the product records, read live.
| Outdoor unit | Ports | Free after 3 heads | Precharged | Max. per head / total | Sound | Min. circuit ampacity (MCA) | Indicative LogisVert amount |
|---|---|---|---|---|---|---|---|
| MHMZ327AHRI 210605813 | 3 | 0 | 74 ft (22.5 m) | 98 / 197 ft | 63 dB(A) | 25 A | $3,192 |
| MHMZ436AHRI 210605816 | 4 | 1 | 98 ft (30 m) | 115 / 262 ft | 62 dB(A) | 40 A | $3,960 |
| MHMZ548AHRI 210605819 | 5 | 2 | 123 ft (37.5 m) | 115 / 262 ft | 65 dB(A) | 40 A | $4,320 |
Ports, lengths, sound: CONFORTO multi-zone brochure, rev. 15/05/26. MCA and amounts: pulled live from our product pages. Only Hydro-Québec confirms the amount granted.
03 · In 2 or 3 zones
The shop sells the same MHMZ327 on the 2-zone page and on this one, under the same AHRI certificate. In 3 zones it has no free port left and the piping gets longer.
| MHMZ327, 2 zones | MHMZ327, 3 zones | |
|---|---|---|
| AHRI certificate | 210605813 | 210605813 |
| Rated heat at −8.3 °C (NEEP) | 26,600 BTU/h | 26,600 BTU/h |
| Indicative LogisVert amount | $3,192 | $3,192 |
| Free ports | 1 | none |
| Example: 25 ft per line | 50 ft: under the 74 ft precharge, nothing to add | 75 ft: 1 ft beyond the 74 ft precharge, 0.16 oz to add |
Certificate, heat and amounts: pulled live from the product pages of both systems. Only Hydro-Québec confirms the amount granted. Ports, precharge and refrigerant to add: multi-zone brochure.
04 · At −8.3 and −15 °C
Two test points: rated and maximum heat at −8.3 °C, then heat at −15 °C. NEEP lists no value at −30 °C for the MHMZ units; the brochure gives −30 °C as the heating operating limit.
NEEP list (AHRI certificates 210605813, 210605816 and 210605819); scale 0 to 50,000 BTU/h. Rated values at −8.3 °C and −15 °C pulled live from our product pages.
05 · Did you know
25,000
At maximum speed, the MHMZ327 goes from 27,200 BTU/h at −8.3 °C to 25,000 BTU/h at −15 °C.
NEEP list (AHRI certificates 210605813, 210605816 and 210605819)5 °C
A button on the outdoor unit’s control board starts the automatic correction of wiring or piping mix-ups between the heads (“CE” on the display, 5 to 10 minutes). The manual says it needs more than 5 °C outside.
MHMZ manual 615000580Wi-Fi
With several zones, the brochure says a Wi-Fi module is needed to control every unit remotely, from the free app.
Multi-zone brochure06 · Questions
The heads of a CONFORTO 3-zone system are chosen at your home, during the visit. The CONFORTO multi-zone page shows the head families.
Multi-zone brochureThe outdoor unit is precharged for 74 ft (MHMZ327), 98 ft (MHMZ436) or 123 ft (MHMZ548) of line. Beyond that, 0.16 oz of R-410A is added per foot. The maximums are 98, 115 and 115 ft per head, and 197, 262 and 262 ft in total. The manual also calls for at least 3 m of piping to limit vibration and noise, a minimum we apply to each line.
Multi-zone brochure; MHMZ manual 615000580The MHMZ436 keeps one free port, the MHMZ548 two. No maximum connected head capacity is published, so adding a head is confirmed during the in-home estimate, within the maximum line lengths. The MHMZ327 stays at three rooms.
Multi-zone brochureThe brochure gives a heating operating range down to −30 °C. NEEP lists values down to −15 °C: 25,000, 36,000 and 45,000 BTU/h depending on the unit.
Multi-zone brochure; NEEP listThe indicative amount follows the rule in Hydro-Québec’s guide: $120 per 1,000 BTU/h of heat at −8 °C for an ENERGY STAR cold-climate heat pump. That gives $3,192 (MHMZ327), $3,960 (MHMZ436) and $4,320 (MHMZ548). The aid is for owners, and only Hydro-Québec confirms the amount granted.
LogisVert participation guide, version 1.10; ENERGY STARThe brochure gives 63 dB(A) for the MHMZ327, 62 dB(A) for the MHMZ436 and 65 dB(A) for the MHMZ548.
Multi-zone brochurePricing is by quote. The in-home estimate is free, with no commitment.
AirGreen · Air conditioning & heating
We look at each line’s route with you, then choose the outdoor unit and the heads together.
LogisVert amounts are indicative: only Hydro-Québec confirms the amount granted. Priced by quote; free in-home estimate.