3-Zone Heat Pump CONFORTO MHMZ | 27,000 BTU - R410A

In stock
SKU: MHMZ327DACFC
27,000BTU/h · 3 heads
−30 °Cheats down to
$3,192LogisVert, indicative
ENERGY STAR® cold climateOptional Wi-FiR-410AUp to 3 heads
Talk to a technician · 514 316-2973
Outdoor unit MHMZ327DACFCPossible indoor models MHWAL09DACFC, MHWAL18DACFCAHRI 210605813· ENERGY STAR 2495138
In short

The Conforto MHMZ 27 000 multi-zone heat pump heats and cools 3 rooms with a single outdoor unit. ENERGY STAR cold-climate certified, it delivers 26,600 BTU/h at −8 °C, heats down to −30 °C and qualifies for a $3,192 LogisVert grant. Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.

01 · The verdict in 10 seconds

3 rooms, one outdoor unit.

Figures come from the manufacturer’s data and the AHRI certification.

AHRI 210605813
26,600BTU/h at −8 °C
−30 °Cstill heating
3heads
2.3COP at −8 °C
$3,192LogisVert, indicative
02 · The machine

The parts that make a multi-zone system.

Tap a part to learn more.

MHMZ327DACFC

Outdoor unit

One compressor for the whole house. It supplies up to 3 heads.

03 · How it works

Turn rooms on and off. Watch the power being shared.

One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.

04 · My plan

Tell us your rooms. We tell you if this size is enough.

Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide, the real calculation is done room by room at your home.

05 · The series

The whole series at a glance: find the box that fits you.

Each box is a product: the outdoor unit’s size, and the number of heads.

Outdoor2 zones3 zones4 zones5 zones
18,000BTU
2
27,000BTU
2Here
36,000BTU
234
48,000BTU
2345

Conforto MHMZ 27 000 · 3 zones

26,600 BTU/h
at −8 °C
$3,192
LogisVert

Up to 3 heads on this outdoor unit. Tap another box to see that size.

06 · Deep cold

At −15 °C, it still delivers 92 % of its rated capacity.

Tap a temperature: capacity, efficiency and the cost of one hour of heating.

07 · The bill

At every temperature, cheaper than baseboards.

Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.

08 · Efficiency

The official ratings, on the same scales as before.

SEER2, HSPF2 and EER2 come from the AHRI certification.

SEER2 · seasonal cooling23.0
Scale 1 – 30
HSPF2 · seasonal heating10.6
Scale 1 – 15
EER2 · cooling in peak heat12.5
Scale 1 – 20
COP at −15 °C1.8
Scale 0 – 4
09 · LogisVert grant

A grant you can calculate, not guess.

26,600 BTU/h÷ 1,000 ×$120=$3,192

The capacity at −8 °C. $120 per 1,000 BTU/h is the rate for ENERGY STAR cold-climate heat pumps (guide v1.10).

Set for this system (AHRI 210605813). Another head combination (ducted, console) can change the AHRI number, and so the amount.
Cap: the grant never exceeds 100 % of the purchase and installation cost before taxes.
9 months after installation to apply; +5 % when two measures are in the same request.
All about LogisVert, with the simulator
10 · Multi-zone or wall units

One multi-zone or several wall units? Both sides, honestly.

This multi-zone3 wall units
On the wall1 outdoor unit3 outdoor units
Electrical1 dedicated circuitOne circuit per unit
CapacityShared between roomsReserved for each room
If the outdoor unit stopsEvery zone stopsOnly one room
ModesSame mode everywhereEach room chooses
LogisVert$3,192 for the systemDepends on each model

We compare both options on your floor plan during the estimate.

11 · Installation

What to know before installing a multi-zone system.

Dimensions, wiring and lines, drawn. Then our six steps.

The outdoor unit, dimensioned

31.90 in
MHMZ327DACFCDepth 16.10 in
37.20 in
Dimensions: product sheet (W × D × H).

One circuit for the whole house

Electrical panel
Load calculation before the quote
40 A max. breaker
MCA 25 A · 220 V
Outdoor unit
Head 1
Head 2
Head 3
Our RBQ licence covers electrical work (subclass 16).
01Room-by-room visit and surveyWe measure each zone and note insulation and windows. The on-site estimate is free.
02Heads and line layoutOne pair of lines per head.
03Outdoor unit baseAbove the snow line, away from the neighbours’ bedroom windows.
04Exposed, finished linesLines under line covers, no work inside the walls.
05Dedicated circuit220 V, MCA 25 A, 40 A protection. The panel load calculation is done before the quote.
06Commissioning, zone by zoneEach head is tested and the controls set up. Then the LogisVert application within 9 months.
12 · Sound

Published sound levels, on one scale.

We use the outdoor figure to choose where the unit goes.

63
20 dB(A)3040506070
63 Outdoor unit
Values in dB(A). Indoor values are those of the sheet’s reference head; each head has its own, confirmed for the chosen model. Municipal noise by-laws vary by borough.
13 · What sets it apart

What is particular about this machine.

Only facts published by ENERGY STAR, NEEP or the manufacturer.

8,400BTU/h at low speedMinimum certified capacity (NEEP): it slows down instead of stopping when the load drops.
$3,192LogisVert grantAmount for the owner of an existing home, according to Hydro-Québec’s list of October 19, 2026.
150 WBase pan heaterHeater in the outdoor unit’s base pan, against ice (NEEP).
14 · Specifications

Every number, and where it comes from.

Each line carries its source; a line with no published value is not shown.

Performance
Cooling capacity (size)27,000 BTUSheet
SEER2 (seasonal cooling efficiency)23.0AHRI
EER2 (instant cooling efficiency)12.5AHRI
HSPF2 (seasonal heating efficiency, region IV)10.6AHRI
Heating
Capacity at −8 °C26,600 BTU/h · COP 2.3Sheet
Capacity at −15 °C25,000 BTU/h · COP 1.8Sheet
Capacity at -15 °C (max.)25,000 BTU/h · COP 1.8Sheet
Heats down to−30 °CSheet
Zones and heads
Zones on this product3 Zones (Triple Zone)Sheet
Maximum zones3 Zones (Triple Zone)Sheet
Possible indoor modelsMHWAL09DACFC, MHWAL18DACFCSheet
Indoor dimensions (W × D × H)33.70 x 9.10 x 11.70, 40.30 x 9.70 x 12.60 inSheet
Installation
Outdoor unit (W × D × H)37.20 x 16.10 x 31.90 inSheet
Outdoor sound63 dB(A)Sheet
Electrical
Voltage220 VSheet
MCA (minimum circuit ampacity)25 ASheet
MOP (maximum overcurrent protection)40 ASheet
RefrigerantR-410ASheet
Wi-FiEn OptionSheet
Certifications and warranty
AHRI210605813AHRI
ENERGY STARYes · cold climate · ID 2495138Sheet
LogisVert grant (indicative)$3,192Sheet
AirGreen extended warrantyPossibleSheet
15 · Official brochures

The manufacturer’s documentation, as PDF.

16 · Description

Everything we have written about this system.

The living room and two bedrooms on a single condenser: a whole small home in three zones

In a condo or a small house, three rooms account for most of daily life: the living room, the main bedroom and a second bedroom or an office. The 3-Zone Heat Pump CONFORTO MHMZ | 27,000 BTU - R410A equips each one with a wall head and connects them all to a single MHMZ327DACFC condenser. One unit outside, three set points inside.

The condenser serves 3 zones here, which is its maximum of 3. The wall heads intended for it are the MHWAL09DACFC and the MHWAL18DACFC. Its certified ratings are 23.0 SEER2, 12.5 EER2 and 10.6 HSPF2. The system is ENERGY STAR certified with the cold-climate designation under ENERGY STAR ID 2495138, and it qualifies for a $3,192 LogisVert grant.

A complete home, three zones

This size targets homes where three rooms carry all the comfort: a condo 5 ½, the ground floor of a bungalow with a living room and two bedrooms, or a small house whose kitchen is open to the living room. Each closed room gets its own head, and the kitchen benefits from the living-room head.

The result depends on the insulation. In a recent or renovated home, the three heads can become the main heat source. In an older house, we calculate the share the heat pump can take on in each room and the share left to the electric baseboards, then present it to you before signing.

The three heads and where they go

The MHWAL18DACFC, the larger of the two intended heads, goes in the living room: it is the largest and most glazed room. The bedrooms get the MHWAL09DACFC, smaller and well suited to a closed room used mostly at night. The exact combination is confirmed after the load calculation.

In a small home, the location of each head is decided carefully. In the living room, we place it so it blows toward the open kitchen without aiming straight at the sofa, and away from the stove, whose heat would skew the temperature reading. In a bedroom, the head goes high on the wall, preferably on an exterior wall to shorten the lines, with airflow that sweeps the room without falling on the bed. We show you each location before drilling.

The three heads share the condenser's capacity. With 3 zones out of a maximum of 3, every connection is used: the system covers the home as it is, with no room for a fourth space. If a basement is to be finished later, we point it out during the visit so the size is chosen with full knowledge.

A typical day, zone by zone

In the morning, the bedrooms ask for a little heat on waking while the living room stays at its daytime set point. During the day, the bedrooms are empty: their set point can stay a little lower, and the condenser concentrates its capacity on the living room. In the evening, demand moves back to the bedrooms. The inverter compressor follows this movement without abrupt starts, metering the R-410A refrigerant sent to each head according to its demand.

A single rule frames this operation: the three heads work in the same mode, heating or cooling, as on any multi-zone system of this type. In a home that lives through the same season from one room to the next, it goes unnoticed.

What the certificate shows for winter

The certificate lists 26,600 BTU/h at -8 °C (17 °F), with a COP of 2.30, and 25,000 BTU/h at -15 °C (5 °F), with a COP of 1.80. The maximum published capacity is 25,000 BTU/h at -15 °C. The two points are measured separately; we report each one as published.

At -15 °C, the three heads therefore share 93% of the 27,000 BTU nominal size. A COP of 1.80 means that at that temperature, each kilowatt-hour consumed returns 1.80 kilowatt-hours of heat, where a baseboard returns one. ENERGY STAR's cold-climate designation confirms that the combination meets the low-temperature performance criteria.

These figures come from certificate AHRI 210605813, published by NEEP.

The baseboards, kept in reserve

The certificate does not publish a point colder than -15 °C. We therefore recommend keeping the existing baseboards, set slightly below the heads' set point: they stay off for most of the winter and take over during extreme cold. In cold, humid weather, the condenser also runs defrost cycles of a few minutes. The heads then stop blowing warm air and a cloud of vapour rises from the outdoor unit; this is normal.

This system's seasonal ratings

  • 10.6 HSPF2: heating efficiency over the whole cold season. In Quebec, it is the rating that weighs most on the bill.
  • 23.0 SEER2: cooling efficiency over a whole summer.
  • 12.5 EER2: cooling at full load, during a heat wave.
  • COP: the ratio between heat delivered and electricity consumed at a specific temperature, here 2.30 at -8 °C and 1.80 at -15 °C.

Cooling and humidity

In cooling, the system is built around a nominal size of 27,000 BTU/h, shared among the three rooms. The bedrooms are set for the night, the living room for the day, and an empty room can be shut off. The compressor runs for long periods at low speed, which removes moisture from the air and keeps the home comfortable without an overly low set point. Each head also offers a dehumidification mode for muggy days.

The $3,192 LogisVert grant

The system is listed in Hydro-Québec's LogisVert program, with $3,192 for the owner of an existing home, according to the list in effect on the installation date. We confirm eligibility before signing and prepare the detailed invoice, model numbers and proof of payment. Our page on the efficient heat pump grant summarizes the program's conditions.

Installing three heads in a small home

In a condo: approval first

In a condominium building, the condenser's location and drilling through exterior walls often fall under the syndicate's authority. Check the declaration of co-ownership and obtain the required approval before planning the work. We can provide the model numbers and the planned location to support the request.

Our installation

After the visit and the load calculation, the condenser is installed above the snow line, on a balcony, a wall bracket or a stand, sheltered from snow sliding off the roof. Each head gets its own refrigerant line set back to the condenser; the three are grouped in a line cover for a clean run along the wall. Each head also has its own sloped condensate drain.

The condenser is connected to a dedicated circuit, checked at the panel during the visit. Commissioning includes the vacuum, the leak test, a check of each zone and setup of the three remotes with you.

Maintenance

Rinse the filters of all three heads every two weeks in season; they come out by hand. Keep the condenser clear of snow and leaves, without covering it in winter. One HVAC maintenance visit per year cleans the coils, fans and drains and checks the electrical connections. Our cleaning service takes over when you prefer to hand off the annual visit.

AirGreen, for the life of the installation

A family business active for more than fifteen years in Montreal, Laval, Longueuil, the North Shore and the South Shore, we hold RBQ licences for ventilation, refrigeration and electrical work and carry $5,000,000 in liability insurance. The in-home assessment is free, the quote is in writing, and our financing options let you choose the right unit rather than the cheapest one.

Request your free estimate for the 3-Zone Heat Pump CONFORTO MHMZ | 27,000 BTU - R410A. We assess your three rooms and confirm the right size and your grant eligibility before signing.

17 · Questions

What people ask us about multi-zone systems.

Can I heat one room and cool another at the same time?

No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.

What happens when every room calls for heat?

They share the outdoor unit’s capacity: 26,600 BTU/h at −8 °C, 25,000 at −15 °C.

How many heads can I connect?

Up to 3 on this outdoor unit. This product is configured for 3 heads.

How much is the LogisVert grant?

$3,192. The grant never exceeds 100 % of the cost before taxes; apply within 9 months of installation.

Is it ENERGY STAR certified?

Yes, cold climate, ID 2495138.

Down to what temperature does it heat?

Down to −30 °C.

Is it noisy?

Outdoors, 63 dB(A): we place the unit away from bedroom windows.

Why a multi-zone instead of several wall units?

One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.

AirGreen

A multi-zone system is planned room by room. At your home.

We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.

RBQ 5645-9605-01Ventilation 15.8, refrigeration 15.10, electrical 16
We handle the circuitOur licence covers the electrical work
LogisVert : $3,192Indicative amount
Beware of scamsHydro-Québec does no phone or door-to-door solicitation for LogisVert
SourcesCosts: Hydro-Québec Rate D, 11.142 ¢/kWh (second tier, since 1 April 2026). Amounts shown are estimates; only the responsible bodies confirm the grant awarded.