2-Zone Heat Pump CONFORTO MHMZ | 27,000 BTU - R410A
The Conforto MHMZ 27 000 multi-zone heat pump heats and cools 2 rooms with a single outdoor unit. ENERGY STAR cold-climate certified, it delivers 26,600 BTU/h at −8 °C, operates down to −30 °C per the brochure; its indicative LogisVert amount is $3,192; only Hydro-Québec confirms the amount granted. Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.
2 rooms, one outdoor unit.
Figures come from the NEEP list, the AHRI certification and the manufacturer’s brochure.
The parts that make a multi-zone system.
Tap a part to learn more.
Outdoor unit
One compressor for the whole house. It supplies up to 3 heads.
Base pan heater
A heater keeps the outdoor unit’s base pan free of ice below 1 °C and during defrost (NEEP).
Refrigerant lines
One pair of lines per head.
Indoor heads
One head per room, each with its own remote and temperature. Your heads are chosen with you at the visit.
Control
Each zone is set separately.
Turn rooms on and off. Watch the power being shared.
One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.
Tell us your rooms. We tell you if this size is enough.
Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide: the size is confirmed during the on-site assessment, at the visit.
The whole series at a glance: find the box that fits you.
Each box is a product: the outdoor unit’s size, and the number of heads.
At −15 °C, it still delivers 25,000 BTU/h per NEEP.
Tap a temperature: capacity, efficiency and the cost of one hour of heating.
At every temperature, cheaper than baseboards.
Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.
The official ratings, on the same scales as before.
SEER2, HSPF2 and EER2 come from the AHRI certification.
The indicative amount, and where it comes from.
The capacity at −8 °C. $120 per 1,000 BTU/h is the rate for ENERGY STAR cold-climate heat pumps (guide v1.10). Only Hydro-Québec confirms the amount granted.
One multi-zone or several wall units? Both sides, honestly.
We compare both options on your floor plan during the estimate. Only Hydro-Québec confirms the amount granted.
What to know before installing a multi-zone system.
Dimensions, wiring and lines, drawn. Then our six steps.
The outdoor unit, dimensioned
One circuit for the whole house
Published sound levels, on one scale.
We use the outdoor figure to choose where the unit goes.
What is particular about this machine.
Only facts published by ENERGY STAR, NEEP or the manufacturer.
Every number, and where it comes from.
Each line carries its source; a line with no published value is not shown.
The manufacturer’s documentation, as PDF.
Everything we have written about this system.
The living room and the bedroom, heated and cooled with high seasonal ratings
When you replace baseboards with a heat pump, what counts is the heating bill for the whole season, not the performance on a single day. The 2-Zone Heat Pump CONFORTO MHMZ | 27,000 BTU - R410A brings a living space and a bedroom together on a single MHMZ327DACFC condenser, with two wall heads of different sizes and high seasonal ratings in both heating and cooling.
The condenser serves 2 zones here and accepts up to 3 at most. Its AHRI certificate was established with the MHWAL09DACFC and MHWAL18DACFC wall heads; your heads are chosen with you during the visit. Its certified ratings are 23.0 SEER2, 12.5 EER2 and 10.6 HSPF2. The system is ENERGY STAR certified with the cold-climate designation under ENERGY STAR ID 2495138, and its indicative LogisVert amount is $3,192 (only Hydro-Québec confirms the amount granted).
Two rooms, two heads of different sizes
A living space and a bedroom do not have the same needs. The living room, often open to the kitchen, has more floor area, more windows and more occupants; the bedroom is small, closed and used mostly at night. The two heads, chosen during the visit, follow that difference. The MHWAL18DACFC, the larger, goes in the living space; the MHWAL09DACFC, the smaller, in the bedroom.
This uneven split avoids two common mistakes: a head too small for the living room, which strains without ever catching up to the set point, and a head too large for the bedroom, which constantly starts and stops and removes moisture poorly. The condenser then distributes its capacity according to each head's actual demand. The combination of heads is chosen with you during the visit.
What 10.6 HSPF2 and 23.0 SEER2 mean
HSPF2 measures heating efficiency over a whole cold season, taking mild days as well as cold days into account. The higher it is, the less each unit of heat costs in electricity over the whole winter. At 10.6, it is the rating to look at first for a Quebec home, where heating weighs much more than cooling.
Why a seasonal rating rather than a single figure: a heat pump spends most of the winter at moderate temperatures, in October, November, March or April, when it runs at reduced speed. A high seasonal rating reflects precisely that part-load efficiency, the kind that repeats day after day. The NEEP deep-cold points, presented below, complete the picture for the weeks of January and February.
SEER2 does the same for summer: it measures cooling efficiency over the whole warm season. At 23.0, cooling the living room and the bedroom weighs little on the bill. The EER2 of 12.5 measures cooling at full load during a heat wave. Finally, the COP gives the efficiency at a specific temperature.
For which homes
This size suits a condo whose living room and main bedroom are separate, the ground floor of a bungalow, or a semi-detached where the living space and one bedroom carry most of the comfort. In a well-insulated home, the two heads can become the main heat source for these rooms. In an older house, the electric baseboards stay in place for deep cold, and we assess on site the share the heat pump can take on.
Winter according to the NEEP list
The NEEP list gives 26,600 BTU/h at -8 °C (17 °F), with a COP of 2.30, and 25,000 BTU/h at -15 °C (5 °F), with a COP of 1.80. The maximum published capacity is 25,000 BTU/h at -15 °C. The two points are measured separately; we report each one as published.
At -8 °C as at -15 °C, the NEEP list gives it at least 25,000 BTU/h. A COP of 2.30 means that at -8 °C, each kilowatt-hour consumed returns 2.30 kilowatt-hours of heat, where a baseboard returns one. ENERGY STAR's cold-climate designation confirms that the combination meets the low-temperature performance criteria.
These figures come from NEEP's cold-climate heat pump list, for certificate AHRI 210605813.
Backup heat and defrost
The NEEP list gives no point colder than -15 °C. We therefore recommend keeping the existing baseboards as backup, set slightly below the heads' set point: they stay off most of the time and only serve during extreme cold. In cold, humid weather, the condenser also runs defrost cycles of a few minutes; the heads then stop blowing warm air and a cloud of vapour rises from the outdoor unit. This is normal.
The inverter compressor, room by room
The inverter compressor varies its speed instead of starting and stopping. It meters the R-410A refrigerant sent to each head according to its demand: when the bedroom reaches its set point, it slows down while the living room keeps going. The two heads share the condenser's capacity when they call together.
As on any multi-zone system of this type, the two heads work in the same mode, heating or cooling. A living space and a bedroom live through the same season; this rule goes unnoticed.
Summer in the living room and the bedroom
In cooling, the system is built around a nominal size of 27,000 BTU/h, distributed between the two rooms. In the afternoon, the large living-room head does most of the work; at night, it is the small bedroom head. Extended low-speed operation removes moisture from the air, which keeps both rooms comfortable without an overly low set point. The brochure also lists a dehumidification mode, useful on muggy days.
The indicative LogisVert amount: $3,192
The system is listed in Hydro-Québec's LogisVert program, with an indicative amount of $3,192 for the owner of an existing home, according to the list in effect on the installation date. Only Hydro-Québec confirms the amount granted. We check eligibility before signing and prepare the detailed invoice, model numbers and proof of payment. Our page on the efficient heat pump grant summarizes the program's conditions.
Installation and maintenance
Our installation
- Visit and on-site assessment: we measure both rooms and note the windows and insulation.
- Condenser: above the snow line, on a wall bracket or a stand, sheltered from snow sliding off the roof.
- Refrigerant lines: one set per head back to the condenser, protected by a line cover outdoors.
- Drains: one sloped condensate drain per head.
- Electrical: a dedicated circuit for the condenser, checked at the panel during the visit.
- Commissioning: vacuum, leak test, check of both zones and setup of the remotes with you.
A third zone possible later
With 2 zones out of a maximum of 3, the condenser keeps one connection free. A child's bedroom, an office or a basement room could be added one day. Before any addition, we check that the remaining capacity is enough for the new room without shortchanging the first two, and that the combination follows the manufacturer's rules.
Maintenance
Rinse the filters of both heads every two weeks in season; the living-room one, near the kitchen, gets dirty faster. Keep the condenser clear of snow and leaves, without covering it in winter. One HVAC maintenance visit per year cleans the coils, fans and drains and checks the electrical connections. Our cleaning service takes over when you prefer to hand off the annual visit.
AirGreen, the company behind the installation
A family business active for more than fifteen years in Montreal, Laval, Longueuil, the North Shore and the South Shore, we hold RBQ licences for ventilation, refrigeration and electrical work and carry $5,000,000 in liability insurance. The in-home assessment is free, the quote is in writing, and our financing options let you choose the right unit rather than the cheapest one.
Request your free estimate for the 2-Zone Heat Pump CONFORTO MHMZ | 27,000 BTU - R410A. We assess your living room and your bedroom and confirm the right size and check your grant eligibility before signing.
What people ask us about multi-zone systems.
Can I heat one room and cool another at the same time?
No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.
What happens when every room calls for heat?
They share the outdoor unit’s capacity: 26,600 BTU/h at −8 °C, 25,000 at −15 °C.
How many heads can I connect?
Up to 3 on this outdoor unit. This product is configured for 2 heads.
What is the indicative LogisVert amount?
$3,192. It is an indicative amount: only Hydro-Québec confirms the amount granted. The grant never exceeds 100 % of the cost before taxes; apply within 9 months of installation.
Is it ENERGY STAR certified?
Yes, cold climate, ID 2495138.
Down to what temperature does it operate?
Per the brochure, down to −30 °C.
Is it noisy?
Outdoors, 63 dB(A): we place the unit away from bedroom windows.
Why a multi-zone instead of several wall units?
One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.
A multi-zone system is planned at your home, during the visit.
We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.