3-Zone Heat Pump CONFORTO MHMZ | 48,000 BTU - R410A

In stock
SKU: MHMZ548DACFC
48,000BTU/h · 3 heads
−30 °Cheats down to
$4,320LogisVert, indicative
ENERGY STAR® cold climateOptional Wi-FiR-410AUp to 5 heads
Talk to a technician · 514 316-2973
Outdoor unit MHMZ548DACFCPossible indoor models MHWAL09DACFC, MHWAL12DACFC, MHWAL24DACFCAHRI 210605819· ENERGY STAR 2495078
In short

The Conforto MHMZ 48 000 multi-zone heat pump heats and cools 3 rooms with a single outdoor unit. ENERGY STAR cold-climate certified, it delivers 36,000 BTU/h at −8 °C, heats down to −30 °C and qualifies for a $4,320 LogisVert grant. Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.

01 · The verdict in 10 seconds

3 rooms, one outdoor unit.

Figures come from the manufacturer’s data and the AHRI certification.

AHRI 210605819
36,000BTU/h at −8 °C
−30 °Cstill heating
3 → 5heads, on the same unit
2.3COP at −8 °C
$4,320LogisVert, indicative
02 · The machine

The parts that make a multi-zone system.

Tap a part to learn more.

MHMZ548DACFC

Outdoor unit

One compressor for the whole house. It supplies up to 5 heads.

03 · How it works

Turn rooms on and off. Watch the power being shared.

One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.

04 · My plan

Tell us your rooms. We tell you if this size is enough.

Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide, the real calculation is done room by room at your home.

05 · The series

The whole series at a glance: find the box that fits you.

Each box is a product: the outdoor unit’s size, and the number of heads.

Outdoor2 zones3 zones4 zones5 zones
18,000BTU
2
27,000BTU
23
36,000BTU
234
48,000BTU
2Here45

Conforto MHMZ 48 000 · 3 zones

36,000 BTU/h
at −8 °C
$4,320
LogisVert

Up to 5 heads on this outdoor unit. Tap another box to see that size.

06 · Deep cold

At −15 °C, it still delivers 93 % of its rated capacity.

Tap a temperature: capacity, efficiency and the cost of one hour of heating.

07 · The bill

At every temperature, cheaper than baseboards.

Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.

08 · Efficiency

The official ratings, on the same scales as before.

SEER2, HSPF2 and EER2 come from the AHRI certification.

SEER2 · seasonal cooling21.8
Scale 1 – 30
HSPF2 · seasonal heating9.8
Scale 1 – 15
EER2 · cooling in peak heat11.7
Scale 1 – 20
COP at −15 °C2.0
Scale 0 – 4
09 · LogisVert grant

A grant you can calculate, not guess.

36,000 BTU/h÷ 1,000 ×$120=$4,320

The capacity at −8 °C. $120 per 1,000 BTU/h is the rate for ENERGY STAR cold-climate heat pumps (guide v1.10).

Set for this system (AHRI 210605819). Another head combination (ducted, console) can change the AHRI number, and so the amount.
Cap: the grant never exceeds 100 % of the purchase and installation cost before taxes.
9 months after installation to apply; +5 % when two measures are in the same request.
All about LogisVert, with the simulator
10 · Multi-zone or wall units

One multi-zone or several wall units? Both sides, honestly.

This multi-zone3 wall units
On the wall1 outdoor unit3 outdoor units
Electrical1 dedicated circuitOne circuit per unit
CapacityShared between roomsReserved for each room
If the outdoor unit stopsEvery zone stopsOnly one room
ModesSame mode everywhereEach room chooses
LogisVert$4,320 for the systemDepends on each model

We compare both options on your floor plan during the estimate.

11 · Installation

What to know before installing a multi-zone system.

Dimensions, wiring and lines, drawn. Then our six steps.

The outdoor unit, dimensioned

52.50 in
MHMZ548DACFCDepth 16.30 in
37.50 in
Dimensions: product sheet (W × D × H).

One circuit for the whole house

Electrical panel
Load calculation before the quote
60 A max. breaker
MCA 40 A · 220 V
Outdoor unit
Head 1
Head 2
Head 3
Our RBQ licence covers electrical work (subclass 16).
01Room-by-room visit and surveyWe measure each zone and note insulation and windows. The on-site estimate is free.
02Heads and line layoutOne pair of lines per head.
03Outdoor unit baseAbove the snow line, away from the neighbours’ bedroom windows.
04Exposed, finished linesLines under line covers, no work inside the walls.
05Dedicated circuit220 V, MCA 40 A, 60 A protection. The panel load calculation is done before the quote.
06Commissioning, zone by zoneEach head is tested and the controls set up. Then the LogisVert application within 9 months.
12 · Sound

Published sound levels, on one scale.

We use the outdoor figure to choose where the unit goes.

65
20 dB(A)3040506070
65 Outdoor unit
Values in dB(A). Indoor values are those of the sheet’s reference head; each head has its own, confirmed for the chosen model. Municipal noise by-laws vary by borough.
13 · What sets it apart

What is particular about this machine.

Only facts published by ENERGY STAR, NEEP or the manufacturer.

13,000BTU/h at low speedMinimum certified capacity (NEEP): it slows down instead of stopping when the load drops.
$4,320LogisVert grantAmount for the owner of an existing home, according to Hydro-Québec’s list of October 19, 2026.
150 WBase pan heaterHeater in the outdoor unit’s base pan, against ice (NEEP).
14 · Specifications

Every number, and where it comes from.

Each line carries its source; a line with no published value is not shown.

Performance
Cooling capacity (size)48,000 BTU · 4 tonsSheet
SEER2 (seasonal cooling efficiency)21.8AHRI
EER2 (instant cooling efficiency)11.7AHRI
HSPF2 (seasonal heating efficiency, region IV)9.8AHRI
Heating
Capacity at −8 °C36,000 BTU/h · COP 2.3Sheet
Capacity at −15 °C45,000 BTU/h · COP 2.0Sheet
Capacity at -15 °C (max.)45,000 BTU/h · COP 2.0Sheet
Heats down to−30 °CSheet
Zones and heads
Zones on this product3 Zones (Triple Zone)Sheet
Maximum zones5 ZonesSheet
Possible indoor modelsMHWAL09DACFC, MHWAL12DACFC, MHWAL24DACFCSheet
Indoor dimensions (W × D × H)33.70 x 9.10 x 11.70, 47.10 x 11.00 x 14.60 inSheet
Installation
Outdoor unit (W × D × H)37.50 x 16.30 x 52.50 inSheet
Outdoor sound65 dB(A)Sheet
Electrical
Voltage220 VSheet
MCA (minimum circuit ampacity)40 ASheet
MOP (maximum overcurrent protection)60 ASheet
RefrigerantR-410ASheet
Wi-FiEn OptionSheet
Certifications and warranty
AHRI210605819AHRI
ENERGY STARYes · cold climate · ID 2495078Sheet
LogisVert grant (indicative)$4,320Sheet
AirGreen extended warrantyPossibleSheet
15 · Official brochures

The manufacturer’s documentation, as PDF.

16 · Description

Everything we have written about this system.

A cathedral-ceiling living room and two bedrooms, served by the same condenser

A living room with a cathedral ceiling is often the most beautiful room in the house and the hardest to keep comfortable. Heat rises to the ridge in winter, large windows let the sun in during summer, and the bedrooms, closed and lower, live in a completely different climate. The 3-Zone Heat Pump CONFORTO MHMZ | 48,000 BTU - R410A treats these three spaces separately, with three wall heads connected to a single MHMZ548DACFC condenser.

This 4-ton condenser serves 3 zones here and accepts up to 5 at most. The wall heads intended for it are the MHWAL09DACFC, the MHWAL12DACFC and the MHWAL24DACFC. Its certified ratings are 21.8 SEER2, 11.7 EER2 and 9.8 HSPF2. The system is ENERGY STAR certified with the cold-climate designation under ENERGY STAR ID 2495078, and it qualifies for a $4,320 LogisVert grant.

The challenge of a high ceiling

In a tall room, air settles in layers. Warm air collects under the ceiling, cool air stays at floor level, and your feet can be cold in a room that seems warm on the thermometer. The large glazed areas common in these living rooms add losses in winter and heat gains in summer. A small wall head is not enough to stir such a volume.

This size therefore targets homes whose main room is large and tall: a bungalow with a cathedral ceiling, a country house with a mezzanine, a living room extended under a sloped roof. The other two zones serve the bedrooms. The load calculation accounts for the room's actual volume, not just its floor area.

The MHWAL24DACFC in a large volume

For the living room, we plan the MHWAL24DACFC, the largest of the intended heads. It is not installed at the top of the wall, where the air is already warm, but at a height that lets it blow toward the occupied zone and remains accessible for filter maintenance. It blows along the length of the room, toward the windows rather than against a wall.

A ceiling fan helps a great deal in these rooms. Set to push air gently downward in winter, it brings the heat collected under the ridge back to the occupied zone and makes the head's work more effective. If your living room already has one, we take it into account when choosing the location.

The two bedrooms

The bedrooms get smaller heads: the MHWAL12DACFC for the main bedroom, the MHWAL09DACFC for a child's or guest room. Closed at night, they need their own set point, independent of the living room's.

The three heads share the condenser's capacity. During the day, the living room takes the largest share; at night, the bedrooms do. With 3 zones out of a maximum of 5, two connections remain free to equip another bedroom or an office later, after checking the remaining capacity.

A mezzanine open to the living room is a special case. It benefits from the large room's air in winter, but it collects heat under the roof in summer and quickly becomes the hottest zone in the house. During the visit, we assess whether the living-room head is enough to cover it or whether it deserves its own head on one of the free connections.

Winter according to the certificate

The certificate lists 36,000 BTU/h at -8 °C (17 °F), with a COP of 2.30, and 45,000 BTU/h at -15 °C (5 °F), with a COP of 2.00. The maximum published capacity is 45,000 BTU/h at -15 °C. The two points are measured separately; we report each one as published.

A COP of 2.00 means that at -15 °C, each kilowatt-hour consumed returns two kilowatt-hours of heat, where an electric baseboard returns one. At -8 °C, the ratio rises to 2.30. ENERGY STAR's cold-climate designation confirms that the combination meets the low-temperature performance criteria.

These figures come from certificate AHRI 210605819, published by NEEP.

Backup heat and defrost

The certificate does not publish a point colder than -15 °C. In a heavily glazed living room, backup remains worthwhile: the existing electric baseboards or fireplace stay in place, set slightly below the heads' set point, and take over during extreme cold. In cold, humid weather, the condenser also runs defrost cycles of a few minutes; the heads then stop blowing warm air and a cloud of vapour rises from the outdoor unit. This is normal.

The inverter compressor and its three zones

The inverter compressor varies its speed according to demand and meters the R-410A refrigerant sent to each head. In the living room, it runs for long periods at moderate speed, which keeps the air moving continuously and limits stratification. Shutting off an unoccupied bedroom leaves the other two zones running normally. As on any multi-zone system of this type, the three heads work in the same mode, heating or cooling.

Summer under a cathedral ceiling

In cooling, the system is built around a nominal size of 48,000 BTU/h for the three zones. In a tall, glassy living room, sunny afternoons are what count: blinds on the upper windows lighten the load considerably. Extended low-speed operation removes moisture from the air, and each head offers a dehumidification mode for muggy days. The bedrooms, for their part, are cooled for the night without cooling the whole living room.

The 21.8 SEER2, 11.7 EER2 and 9.8 HSPF2 ratings

The HSPF2 of 9.8 measures heating efficiency over the whole cold season; in Quebec, it is the rating that weighs most on the bill. The SEER2 of 21.8 measures cooling efficiency over a whole summer, and the EER2 of 11.7 measures cooling at full load, in hot weather. The COP expresses efficiency at a specific temperature: it is the ratio between heat delivered and electricity consumed.

The $4,320 LogisVert grant

The system is listed in Hydro-Québec's LogisVert program, with $4,320 for the owner of an existing home, according to the list in effect on the installation date. We confirm eligibility before signing and prepare the detailed invoice, model numbers and proof of payment. Our page on the efficient heat pump grant summarizes the program's conditions.

Installation and maintenance

Our installation

After the visit and the load calculation, the condenser is installed above the snow line, on a stand or a sturdy bracket, away from snow sliding off the roof. A 4-ton condenser requires a larger dedicated circuit than a small wall-mounted heat pump; we check the panel's space and capacity during the visit.

Each head gets its own refrigerant line set back to the condenser, grouped in a line cover outdoors, and its own sloped condensate drain. Commissioning includes the vacuum, the leak test, a check of each zone and setup of the three remotes with you.

Maintenance

Rinse the filters of all three heads every two weeks in season; the living-room one comes out with a stepladder, hence the importance of its location. Keep the condenser clear of snow and leaves, without covering it in winter. One HVAC maintenance visit per year cleans the coils, fans and drains and checks the electrical connections. Our cleaning service takes over when you prefer to hand off the annual visit.

AirGreen, for the life of the installation

A family business active for more than fifteen years in Montreal, Laval, Longueuil, the North Shore and the South Shore, we hold RBQ licences for ventilation, refrigeration and electrical work and carry $5,000,000 in liability insurance. The in-home assessment is free, the quote is in writing, and our financing options let you choose the right unit rather than the cheapest one.

Request your free estimate for the 3-Zone Heat Pump CONFORTO MHMZ | 48,000 BTU - R410A. We assess your living room and bedrooms and confirm the right size and your grant eligibility before signing.

17 · Questions

What people ask us about multi-zone systems.

Can I heat one room and cool another at the same time?

No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.

What happens when every room calls for heat?

They share the outdoor unit’s capacity: 36,000 BTU/h at −8 °C, 45,000 at −15 °C.

How many heads can I connect?

Up to 5 on this outdoor unit. This product is configured for 3 heads.

How much is the LogisVert grant?

$4,320. The grant never exceeds 100 % of the cost before taxes; apply within 9 months of installation.

Is it ENERGY STAR certified?

Yes, cold climate, ID 2495078.

Down to what temperature does it heat?

Down to −30 °C.

Is it noisy?

Outdoors, 65 dB(A): we place the unit away from bedroom windows.

Why a multi-zone instead of several wall units?

One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.

AirGreen

A multi-zone system is planned room by room. At your home.

We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.

RBQ 5645-9605-01Ventilation 15.8, refrigeration 15.10, electrical 16
We handle the circuitOur licence covers the electrical work
LogisVert : $4,320Indicative amount
Beware of scamsHydro-Québec does no phone or door-to-door solicitation for LogisVert
SourcesCosts: Hydro-Québec Rate D, 11.142 ¢/kWh (second tier, since 1 April 2026). Amounts shown are estimates; only the responsible bodies confirm the grant awarded.