2-Zone Heat Pump CONFORTO MHMZ | 48,000 BTU - R410A
The Conforto MHMZ 48 000 multi-zone heat pump heats and cools 2 rooms with a single outdoor unit. ENERGY STAR cold-climate certified, it delivers 36,000 BTU/h at −8 °C, operates down to −30 °C per the brochure; its indicative LogisVert amount is $4,320; only Hydro-Québec confirms the amount granted. Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.
2 rooms, one outdoor unit.
Figures come from the NEEP list, the AHRI certification and the manufacturer’s brochure.
The parts that make a multi-zone system.
Tap a part to learn more.
Outdoor unit
One compressor for the whole house. It supplies up to 5 heads.
Base pan heater
A heater keeps the outdoor unit’s base pan free of ice below 1 °C and during defrost (NEEP).
Refrigerant lines
One pair of lines per head.
Indoor heads
One head per room, each with its own remote and temperature. Your heads are chosen with you at the visit.
Control
Each zone is set separately.
Turn rooms on and off. Watch the power being shared.
One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.
Tell us your rooms. We tell you if this size is enough.
Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide: the size is confirmed during the on-site assessment, at the visit.
The whole series at a glance: find the box that fits you.
Each box is a product: the outdoor unit’s size, and the number of heads.
At −15 °C, it still delivers 45,000 BTU/h per NEEP.
Tap a temperature: capacity, efficiency and the cost of one hour of heating.
At every temperature, cheaper than baseboards.
Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.
The official ratings, on the same scales as before.
SEER2, HSPF2 and EER2 come from the AHRI certification.
The indicative amount, and where it comes from.
The capacity at −8 °C. $120 per 1,000 BTU/h is the rate for ENERGY STAR cold-climate heat pumps (guide v1.10). Only Hydro-Québec confirms the amount granted.
One multi-zone or several wall units? Both sides, honestly.
We compare both options on your floor plan during the estimate. Only Hydro-Québec confirms the amount granted.
What to know before installing a multi-zone system.
Dimensions, wiring and lines, drawn. Then our six steps.
The outdoor unit, dimensioned
One circuit for the whole house
Published sound levels, on one scale.
We use the outdoor figure to choose where the unit goes.
What is particular about this machine.
Only facts published by ENERGY STAR, NEEP or the manufacturer.
Every number, and where it comes from.
Each line carries its source; a line with no published value is not shown.
The manufacturer’s documentation, as PDF.
Everything we have written about this system.
An intergenerational home, two households, two settings and a single condenser
When parents move into a suite finished in the basement or in an addition, the house shelters two households with neither the same schedules nor the same idea of a comfortable temperature. The 2-Zone Heat Pump CONFORTO MHMZ | 48,000 BTU - R410A gives each one its own wall head and its own remote, fed by a single MHMZ548DACFC condenser installed outside.
This 4-ton condenser serves 2 zones here and accepts up to 5 at most. Its AHRI certificate was established with the MHWAL09DACFC, MHWAL12DACFC and MHWAL24DACFC wall heads; your heads are chosen with you during the visit. Its certified ratings are 21.8 SEER2, 11.7 EER2 and 9.8 HSPF2. The system is ENERGY STAR certified with the cold-climate designation under ENERGY STAR ID 2495078, and its indicative LogisVert amount is $4,320 (only Hydro-Québec confirms the amount granted).
Two households under one roof
In an intergenerational home, needs differ from one floor to the next. Grandparents often prefer a warmer house and spend their days at home; the family on the ground floor leaves in the morning and comes back in the evening. A single set point for the whole house is bound to leave someone unhappy. With two zones, each household sets its own unit as it sees fit, without negotiating over a thermostat.
This size also suits any house that divides into two large, well-separated spaces: an open ground floor and a finished basement, a house and its addition, or a large single-storey house whose bedroom wing is closed off. The assessment of each space confirms that the size is right.
Two large heads
For the main living space, often open to the kitchen, we usually plan the largest head. The second unit gets the head that matches its load: another MHWAL24DACFC if it is just as large, the MHWAL12DACFC if it is a more compact studio. The MHWAL09DACFC is better suited to small closed rooms.
The two heads share the condenser's capacity. When both units call at full demand, it is split between them; when only one is occupied, it gets all the available capacity. With 2 zones out of a maximum of 5, three connections remain free to equip closed bedrooms later, after checking the remaining capacity.
A single mode for both units
There is one thing to know before choosing this system: the heads on the same condenser always work in the same mode, all heating or all cooling. Each household sets its own temperature, but not the mode. In practice, both units live through the same season and the question rarely comes up; it can, however, arise on a few spring or fall days. We discuss it during the visit to agree with you on how to handle those days.
The solution is usually simple. On a mild day when one unit needs a little heat and the other does not, the second unit's head can be turned off or switched to fan mode while the first keeps heating. Each unit keeps its own remote, which prevents one household from unintentionally changing the other's setting.
What the NEEP list shows for winter
The NEEP list gives 36,000 BTU/h at -8 °C (17 °F), with a COP of 2.30, and 45,000 BTU/h at -15 °C (5 °F), with a COP of 2.00. The maximum published capacity is 45,000 BTU/h at -15 °C. The two points are measured separately; we report each one as published.
At -15 °C, a COP of 2.00 means that each kilowatt-hour consumed returns two kilowatt-hours of heat, where an electric baseboard returns one. ENERGY STAR's cold-climate designation confirms that the combination meets the low-temperature performance criteria.
These figures come from NEEP's cold-climate heat pump list, for certificate AHRI 210605819.
Backup heat during deep cold
The NEEP list gives no point colder than -15 °C. In a unit occupied by older people, we are particularly keen on keeping the backup in place: the existing electric baseboards, set slightly below the heads' set point, stay off most of the time and take over during extreme cold. They also fill in the defrost cycles, those few minutes when the condenser melts the frost off its coil and the heads stop blowing warm air. A cloud of vapour above the outdoor unit is normal at those times.
The inverter compressor between two units
The inverter compressor varies its speed according to the demand of the two heads and meters the R-410A refrigerant sent to each one. During the day, it runs slowly for the only occupied unit; in the evening, it speeds up when both households are home. This continuous operation keeps temperatures steady and avoids the repeated starts that wear out equipment.
Summer in both units
In cooling, the system is built around a nominal size of 48,000 BTU/h for the two zones. On the ground floor, the windows and the kitchen load the room; in the basement, it is mostly humidity. Extended low-speed operation removes that moisture, and the dehumidification mode listed in the brochure helps on muggy days.
The 21.8 SEER2, 11.7 EER2 and 9.8 HSPF2 ratings
- SEER2: cooling efficiency over a whole summer.
- EER2: cooling at full load, in hot weather.
- HSPF2: heating efficiency over the whole cold season, calculated for a reference climate (region IV); it is used to compare models.
- COP: the ratio between heat delivered and electricity consumed at a specific temperature, here 2.30 at -8 °C and 2.00 at -15 °C.
The indicative LogisVert amount: $4,320
The system is listed in Hydro-Québec's LogisVert program, with an indicative amount of $4,320 for the owner of an existing home, according to the list in effect on the installation date. Only Hydro-Québec confirms the amount granted. We check eligibility before signing and prepare the detailed invoice, model numbers and proof of payment. Our page on the efficient heat pump grant summarizes the program's conditions.
Installation and maintenance
Our installation
After the visit and the on-site assessment, the condenser is installed above the snow line, on a stand or a sturdy bracket, away from snow sliding off the roof and from bedroom windows. A 4-ton condenser requires a larger dedicated circuit than a small wall-mounted heat pump: we check the panel's space and capacity during the visit.
Each head gets its own refrigerant line set back to the condenser, protected by a line cover outdoors. For a basement unit, the line goes through the foundation wall and the condensate drain often needs a small pump, for lack of a natural slope; we determine that during the visit. Commissioning includes the vacuum, the leak test, a check of both zones and setup of the remotes with each household.
Maintenance
Rinse the filters of both heads every two weeks in season; in an intergenerational home, agree on who takes care of each head. Keep the condenser clear of snow and leaves, without covering it in winter. One HVAC maintenance visit per year cleans the coils, fans and drains and checks the electrical connections. Our cleaning service takes over when you prefer to hand off the annual visit.
AirGreen, the company behind the installation
A family business active for more than fifteen years in Montreal, Laval, Longueuil, the North Shore and the South Shore, we hold RBQ licences for ventilation, refrigeration and electrical work and carry $5,000,000 in liability insurance. The in-home assessment is free, the quote is in writing, and our financing options let you choose the right unit rather than the cheapest one.
Request your free estimate for the 2-Zone Heat Pump CONFORTO MHMZ | 48,000 BTU - R410A. We assess both units and confirm the right size and check your grant eligibility before signing.
What people ask us about multi-zone systems.
Can I heat one room and cool another at the same time?
No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.
What happens when every room calls for heat?
They share the outdoor unit’s capacity: 36,000 BTU/h at −8 °C, 45,000 at −15 °C.
How many heads can I connect?
Up to 5 on this outdoor unit. This product is configured for 2 heads.
What is the indicative LogisVert amount?
$4,320. It is an indicative amount: only Hydro-Québec confirms the amount granted. The grant never exceeds 100 % of the cost before taxes; apply within 9 months of installation.
Is it ENERGY STAR certified?
Yes, cold climate, ID 2495078.
Down to what temperature does it operate?
Per the brochure, down to −30 °C.
Is it noisy?
Outdoors, 65 dB(A): we place the unit away from bedroom windows.
Why a multi-zone instead of several wall units?
One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.
A multi-zone system is planned at your home, during the visit.
We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.