2-Zone Heat Pump CONFORTO MHMZ | 36,000 BTU - R410A

In stock
SKU: MHMZ436DACFC
36,000BTU/h · 2 heads
−30 °Coperates down to, per the brochure
$3,960LogisVert, indicative amount · only Hydro-Québec confirms the amount granted
ENERGY STAR® cold climateOptional Wi-FiR-410AUp to 4 heads
Talk to a technician · 514 316-2973
Outdoor unit MHMZ436DACFCPossible indoor models MHWAL09DACFC, MHWAL12DACFC, MHWAL18DACFCAHRI 210605816· ENERGY STAR 2495072
In short

The Conforto MHMZ 36 000 multi-zone heat pump heats and cools 2 rooms with a single outdoor unit. ENERGY STAR cold-climate certified, it delivers 33,000 BTU/h at −8 °C, operates down to −30 °C per the brochure; its indicative LogisVert amount is $3,960; only Hydro-Québec confirms the amount granted. Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.

01 · The verdict in 10 seconds

2 rooms, one outdoor unit.

Figures come from the NEEP list, the AHRI certification and the manufacturer’s brochure.

AHRI 210605816
33,000BTU/h at −8 °C
−30 °Cstill operating, per the brochure
2 → 4heads, on the same unit
2.4COP at −8 °C
$3,960LogisVert, indicative amount. Only Hydro-Québec confirms the amount granted.
02 · The machine

The parts that make a multi-zone system.

Tap a part to learn more.

MHMZ436DACFC

Outdoor unit

One compressor for the whole house. It supplies up to 4 heads.

03 · How it works

Turn rooms on and off. Watch the power being shared.

One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.

04 · My plan

Tell us your rooms. We tell you if this size is enough.

Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide: the size is confirmed during the on-site assessment, at the visit.

05 · The series

The whole series at a glance: find the box that fits you.

Each box is a product: the outdoor unit’s size, and the number of heads.

Outdoor2 zones3 zones4 zones5 zones
18,000BTU
2
27,000BTU
23
36,000BTU
Here34
48,000BTU
2345

Conforto MHMZ 36 000 · 2 zones

33,000 BTU/h
at −8 °C
$3,960
LogisVert, indicative amount

Up to 4 heads on this outdoor unit. Tap another box to see that size. Only Hydro-Québec confirms the amount granted.

06 · Deep cold

At −15 °C, it still delivers 36,000 BTU/h per NEEP.

Tap a temperature: capacity, efficiency and the cost of one hour of heating.

07 · The bill

At every temperature, cheaper than baseboards.

Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.

08 · Efficiency

The official ratings, on the same scales as before.

SEER2, HSPF2 and EER2 come from the AHRI certification.

SEER2 · seasonal cooling22.2
Scale 1 – 30
HSPF2 · seasonal heating10.3
Scale 1 – 15
EER2 · cooling in peak heat13.6
Scale 1 – 20
COP at −15 °C1.9
Scale 0 – 4
09 · LogisVert, indicative amount

The indicative amount, and where it comes from.

33,000 BTU/h÷ 1,000 ×$120=$3,960

The capacity at −8 °C. $120 per 1,000 BTU/h is the rate for ENERGY STAR cold-climate heat pumps (guide v1.10). Only Hydro-Québec confirms the amount granted.

Indicative amount for this system (AHRI 210605816). Another head combination (ducted, console) can change the AHRI number, and so the amount.
Cap: the grant never exceeds 100 % of the purchase and installation cost before taxes.
9 months after installation to apply; +5 % when two measures are in the same request.
All about LogisVert, with the simulator
10 · Multi-zone or wall units

One multi-zone or several wall units? Both sides, honestly.

This multi-zone2 wall units
On the wall1 outdoor unit2 outdoor units
Electrical1 dedicated circuitOne circuit per unit
CapacityShared between roomsReserved for each room
If the outdoor unit stopsEvery zone stopsOnly one room
ModesSame mode everywhereEach room chooses
LogisVert$3,960 indicative, for the systemDepends on each model

We compare both options on your floor plan during the estimate. Only Hydro-Québec confirms the amount granted.

11 · Installation

What to know before installing a multi-zone system.

Dimensions, wiring and lines, drawn. Then our six steps.

The outdoor unit, dimensioned

52.50 in
MHMZ436DACFCDepth 16.30 in
37.50 in
Dimensions: product sheet (W × D × H).

One circuit for the whole house

Electrical panel
Panel capacity checked before the quote
60 A max. breaker
MCA 40 A · 220 V
Outdoor unit
Head 1
Head 2
Our RBQ licence covers electrical work (subclass 16).
01On-site assessment, at the visitWe measure each zone and note insulation and windows. The on-site estimate is free.
02Heads and line layoutOne pair of lines per head.
03Outdoor unit baseAbove the snow line, away from the neighbours’ bedroom windows.
04Exposed, finished linesLines under line covers, no work inside the walls.
05Dedicated circuit220 V, MCA 40 A, 60 A protection. The electrical panel’s capacity is checked before the quote.
06Commissioning, zone by zoneEach head is tested and the controls set up. Then the LogisVert application within 9 months.
12 · Sound

Published sound levels, on one scale.

We use the outdoor figure to choose where the unit goes.

62
20 dB(A)3040506070
62 Outdoor unit
Values in dB(A). Indoor values are those of the sheet’s reference head; each head has its own, confirmed for the chosen model. Municipal noise by-laws vary by borough.
13 · What sets it apart

What is particular about this machine.

Only facts published by ENERGY STAR, NEEP or the manufacturer.

10,000BTU/h at low speedMinimum capacity listed by NEEP: it slows down instead of stopping when the load drops.
$3,960Indicative LogisVert amountFor the owner of an existing home, according to Hydro-Québec’s list of October 19, 2026. Only Hydro-Québec confirms the amount granted.
150 WBase pan heaterHeater in the outdoor unit’s base pan, against ice (NEEP).
14 · Specifications

Every number, and where it comes from.

Each line carries its source; a line with no published value is not shown.

Performance
Cooling capacity (size)36,000 BTU · 3 tonsSheet
SEER2 (seasonal cooling efficiency)22.2AHRI
EER2 (instant cooling efficiency)13.6AHRI
HSPF2 (seasonal heating efficiency, region IV)10.3AHRI
Heating
Capacity at −8 °C33,000 BTU/h · COP 2.4Sheet
Capacity at −15 °C36,000 BTU/h · COP 1.9Sheet
Capacity at -15 °C (max.)36,000 BTU/h · COP 1.9Sheet
Operates down to, per the brochure−30 °CSheet
Zones and heads
Zones on this product2 Zones (Double Zone)Sheet
Maximum zones4 Zones (Quad Zone)Sheet
Possible indoor modelsMHWAL09DACFC, MHWAL12DACFC, MHWAL18DACFCSheet
Indoor dimensions (W × D × H)33.70 x 9.10 x 11.70, 40.30 x 9.70 x 12.60 inSheet
Installation
Outdoor unit (W × D × H)37.50 x 16.30 x 52.50 inSheet
Outdoor sound62 dB(A)Sheet
Electrical
Voltage220 VSheet
MCA (minimum circuit ampacity)40 ASheet
MOP (maximum overcurrent protection)60 ASheet
RefrigerantR-410ASheet
Wi-FiEn OptionSheet
Certifications and warranty
AHRI210605816AHRI
ENERGY STARYes · cold climate · ID 2495072Sheet
Indicative LogisVert amount (only Hydro-Québec confirms the amount granted)$3,960Sheet
AirGreen extended warrantyPossibleSheet
15 · Official brochures

The manufacturer’s documentation, as PDF.

16 · Description

Everything we have written about this system.

The ground floor and the attic floor, each with its own head, even during heat waves

A floor finished under the roof is often the most pleasant room in the house in spring and the most uncomfortable in July. The sun heats the roof all day, and heat builds up under the sloped ceilings long after sunset. The 2-Zone Heat Pump CONFORTO MHMZ | 36,000 BTU - R410A gives that floor its own wall head, another on the ground floor, and connects them to a single MHMZ436DACFC condenser.

This 3-ton condenser serves 2 zones here and accepts up to 4 at most. Its AHRI certificate was established with the MHWAL09DACFC, MHWAL12DACFC and MHWAL18DACFC wall heads; your heads are chosen with you during the visit. Its certified ratings are 22.2 SEER2, 13.6 EER2 and 10.3 HSPF2. The system is ENERGY STAR certified with the cold-climate designation under ENERGY STAR ID 2495072, and its indicative LogisVert amount is $3,960 (only Hydro-Québec confirms the amount granted).

A floor under the roof, the hardest to cool

An attic converted into a main bedroom, a mezzanine turned into an office, the upper floor of a Cape Cod-style house: these spaces share low walls, sloped ceilings and a roof directly overhead. In summer, they take the roof's heat before every other room. In winter, they lose their own through the same roof if the insulation is thin.

A head on the ground floor cannot cool an upper floor: cold air sinks, it does not rise. That is why this system places a head on each level. The ground-floor one serves the living space; the upper one, the bedrooms or the office under the roof. The on-site assessment takes the roof insulation into account, and we tell you plainly if it limits the result.

Humidity adds to the heat. Under the roof, warm, damp air makes sleep difficult even when the thermometer seems reasonable. By running for long periods at low speed, the upstairs head removes that moisture; the dehumidification mode listed in the brochure helps on muggy days when full cooling is not needed.

What 13.6 EER2, 22.2 SEER2 and 10.3 HSPF2 measure

EER2 measures cooling efficiency at full load, in hot weather. That is exactly the situation of a floor under the roof in July, when the head runs flat out during the hottest hours. At 13.6, this rating is the system's strong point for heat waves.

The SEER2 of 22.2 measures cooling efficiency over a whole summer, mild days included. The HSPF2 of 10.3 does the same for heating over the whole cold season; it is calculated for a reference climate (region IV) and is useful to compare models. Finally, the COP expresses efficiency at a specific temperature: it is the ratio between heat delivered and electricity consumed.

Two zones, two heads to choose

The largest head usually goes in the ground-floor living space. Upstairs, the choice depends on floor area and exposure: the MHWAL12DACFC for a main bedroom under the roof, the MHWAL18DACFC if the floor is open and very exposed, the MHWAL09DACFC for a small office. The on-site assessment decides.

The two heads share the condenser's capacity. On a summer afternoon, the upper floor asks for the largest share; on a winter evening, it is often the ground floor. With 2 zones out of a maximum of 4, two connections remain free for rooms added later, after checking the remaining capacity.

Placing a head under a sloped ceiling

Under the roof, there is often little space at the top of the walls. We install the head on the gable wall or the tallest wall, so it blows along the length of the floor rather than against a slope. It needs enough space above it for the air intake. When the floor is divided into two bedrooms, the head goes in the larger or more exposed one, and we tell you whether the second bedroom will be well served with the door open or deserves its own zone.

Winter: the full nominal size at -15 °C

The NEEP list gives 33,000 BTU/h at -8 °C (17 °F), with a COP of 2.40, and 36,000 BTU/h at -15 °C (5 °F), with a COP of 1.90. The maximum published capacity is 36,000 BTU/h at -15 °C. The two points are measured separately; we report each one as published.

At -15 °C, the NEEP list therefore gives 36,000 BTU/h for this system. A COP of 1.90 means that at that temperature, each kilowatt-hour consumed returns 1.90 kilowatt-hours of heat, where an electric baseboard returns one. ENERGY STAR's cold-climate designation confirms that the combination meets the low-temperature performance criteria.

These figures come from NEEP's cold-climate heat pump list, for certificate AHRI 210605816.

Backup heat and defrost

The NEEP list gives no point colder than -15 °C. We therefore recommend keeping the existing electric baseboards, set slightly below the heads' set point. They stay off for most of the winter and only take over during extreme cold. In cold, humid weather, the condenser also runs defrost cycles of a few minutes: the heads stop blowing warm air and a cloud of vapour rises from the outdoor unit. This is normal.

The inverter compressor and R-410A refrigerant

The inverter compressor varies its speed according to the demand of the two heads and meters the R-410A refrigerant sent to each one. It runs for long periods at moderate speed, which removes moisture from the air in cooling and keeps temperatures steady in heating. For cooling, the system is built around a nominal size of 36,000 BTU/h. The two heads always work in the same mode, heating or cooling, as on any multi-zone system of this type.

The indicative LogisVert amount: $3,960

The system is listed in Hydro-Québec's LogisVert program, with an indicative amount of $3,960 for the owner of an existing home, according to the list in effect on the installation date. Only Hydro-Québec confirms the amount granted. We check eligibility before signing and prepare the detailed invoice, model numbers and proof of payment. Our page on the efficient heat pump grant summarizes the program's conditions.

Installation on two levels

Our installation

The refrigerant line for the ground-floor head is short. The one for the upper floor runs up the facade in a painted line cover; we show you the route before drilling. Each head gets its own refrigerant line set and its own condensate drain, sloped toward the outside.

The condenser is installed above the snow line, on a wall bracket or a stand, away from snow sliding off the roof. It is connected to a dedicated circuit, checked at the panel during the visit. Commissioning includes the vacuum, the leak test, a check of both zones and setup of the remotes with you.

Maintenance

Rinse the filters of both heads every two weeks in season; the upstairs one works hard in summer and deserves particular attention. Keep the condenser clear of snow and leaves, without covering it in winter. One HVAC maintenance visit per year cleans the coils, fans and drains and checks the electrical connections. Our cleaning service takes over when you prefer to hand off the annual visit.

AirGreen, the company behind the installation

A family business active for more than fifteen years in Montreal, Laval, Longueuil, the North Shore and the South Shore, we hold RBQ licences for ventilation, refrigeration and electrical work and carry $5,000,000 in liability insurance. The in-home assessment is free, the quote is in writing, and our financing options let you choose the right unit rather than the cheapest one.

Request your free estimate for the 2-Zone Heat Pump CONFORTO MHMZ | 36,000 BTU - R410A. We assess both levels and confirm the right size and check your grant eligibility before signing.

17 · Questions

What people ask us about multi-zone systems.

Can I heat one room and cool another at the same time?

No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.

What happens when every room calls for heat?

They share the outdoor unit’s capacity: 33,000 BTU/h at −8 °C, 36,000 at −15 °C.

How many heads can I connect?

Up to 4 on this outdoor unit. This product is configured for 2 heads.

What is the indicative LogisVert amount?

$3,960. It is an indicative amount: only Hydro-Québec confirms the amount granted. The grant never exceeds 100 % of the cost before taxes; apply within 9 months of installation.

Is it ENERGY STAR certified?

Yes, cold climate, ID 2495072.

Down to what temperature does it operate?

Per the brochure, down to −30 °C.

Is it noisy?

Outdoors, 62 dB(A): we place the unit away from bedroom windows.

Why a multi-zone instead of several wall units?

One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.

AirGreen

A multi-zone system is planned at your home, during the visit.

We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.

RBQ 5645-9605-01Ventilation 15.8, refrigeration 15.10, electrical 16
We handle the circuitOur licence covers the electrical work
Indicative LogisVert: $3,960Indicative amount; only Hydro-Québec confirms the amount granted
Beware of scamsHydro-Québec does no phone or door-to-door solicitation for LogisVert
SourcesCosts: Hydro-Québec Rate D, 11.142 ¢/kWh (second tier, since 1 April 2026). Amounts shown are estimates; only the responsible bodies confirm the grant awarded.