4-Zone Heat Pump CONFORTO MHMZ | 48,000 BTU - R410A
The Conforto MHMZ 48 000 multi-zone heat pump heats and cools 4 rooms with a single outdoor unit. ENERGY STAR cold-climate certified, it delivers 36,000 BTU/h at −8 °C, operates down to −30 °C per the brochure; its indicative LogisVert amount is $4,320; only Hydro-Québec confirms the amount granted. Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.
4 rooms, one outdoor unit.
Figures come from the NEEP list, the AHRI certification and the manufacturer’s brochure.
The parts that make a multi-zone system.
Tap a part to learn more.
Outdoor unit
One compressor for the whole house. It supplies up to 5 heads.
Base pan heater
A heater keeps the outdoor unit’s base pan free of ice below 1 °C and during defrost (NEEP).
Refrigerant lines
One pair of lines per head.
Indoor heads
One head per room, each with its own remote and temperature. Your heads are chosen with you at the visit.
Control
Each zone is set separately.
Turn rooms on and off. Watch the power being shared.
One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.
Tell us your rooms. We tell you if this size is enough.
Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide: the size is confirmed during the on-site assessment, at the visit.
The whole series at a glance: find the box that fits you.
Each box is a product: the outdoor unit’s size, and the number of heads.
At −15 °C, it still delivers 45,000 BTU/h per NEEP.
Tap a temperature: capacity, efficiency and the cost of one hour of heating.
At every temperature, cheaper than baseboards.
Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.
The official ratings, on the same scales as before.
SEER2, HSPF2 and EER2 come from the AHRI certification.
The indicative amount, and where it comes from.
The capacity at −8 °C. $120 per 1,000 BTU/h is the rate for ENERGY STAR cold-climate heat pumps (guide v1.10). Only Hydro-Québec confirms the amount granted.
One multi-zone or several wall units? Both sides, honestly.
We compare both options on your floor plan during the estimate. Only Hydro-Québec confirms the amount granted.
What to know before installing a multi-zone system.
Dimensions, wiring and lines, drawn. Then our six steps.
The outdoor unit, dimensioned
One circuit for the whole house
Published sound levels, on one scale.
We use the outdoor figure to choose where the unit goes.
What is particular about this machine.
Only facts published by ENERGY STAR, NEEP or the manufacturer.
Every number, and where it comes from.
Each line carries its source; a line with no published value is not shown.
The manufacturer’s documentation, as PDF.
Everything we have written about this system.
Four zones on three levels: basement, ground floor and upper floor, a single 4-ton condenser
In a three-level house, each floor has its own climate. The basement stays cool and damp, the ground floor loses its heat through large windows, and the upper floor receives all the warm air rising up the staircase. The 4-Zone Heat Pump CONFORTO MHMZ | 48,000 BTU - R410A spreads four wall heads over these three levels and connects them to a single MHMZ548DACFC condenser.
This 4-ton condenser serves 4 zones here and accepts up to 5 at most. Its AHRI certificate was established with the MHWAL09DACFC, MHWAL12DACFC and MHWAL24DACFC wall heads; your heads are chosen with you during the visit. Its certified ratings are 21.8 SEER2, 11.7 EER2 and 9.8 HSPF2. The system is ENERGY STAR certified with the cold-climate designation under ENERGY STAR ID 2495078, and its indicative LogisVert amount is $4,320 (only Hydro-Québec confirms the amount granted).
Three levels, three climates
In winter, heat from the ground floor rises to the upper floor, which becomes the warmest level, while the basement stays cold at floor level. In summer, it is the reverse: the upper floor overheats under the roof and the basement, cool but damp, mostly needs to be dried out. A single unit, set to a single set point, cannot satisfy all three levels at once.
With heads spread over the three levels, each floor is set according to its use: a basement kept a little cooler when it is empty, a bedroom cooler for sleeping, a living space comfortable in the evening. This avoids the classic single-thermostat situation, where the upper floor gets too hot because the set point was raised to warm the basement.
This size targets a large two-storey house with a finished basement, or a two-storey whose basement serves as a family room. The result depends on the envelope: in a well-insulated house, the four heads carry most of the heating and all of the cooling. In an older house, we assess on site the share left to the electric baseboards.
How the four heads are distributed
On the ground floor, the largest head usually serves the living space. Upstairs, the main bedroom gets the MHWAL12DACFC and a second bedroom the MHWAL09DACFC. In the basement, the choice depends on the floor area and the insulation of the foundation walls: the MHWAL12DACFC for a mid-sized family room, the MHWAL24DACFC for a large open basement. The on-site assessment decides.
The four heads share the condenser's capacity. When they all call at full demand, it is split between them; the rest of the time, the occupied levels benefit from the capacity the others are not using. With 4 zones out of a maximum of 5, one connection remains free for a room added later, after checking the remaining capacity.
The electrical panel first
A 4-ton condenser requires a larger dedicated circuit than a small wall-mounted heat pump. During the visit, we open the panel: available space, capacity of the electrical service, loads already connected such as a range, a dryer or a water heater. In a house whose panel is already heavily loaded, an upgrade may be needed; we point it out during the visit, and that work appears in the written quote just like the unit.
What the NEEP list shows
The NEEP list gives 36,000 BTU/h at -8 °C (17 °F), with a COP of 2.30, and 45,000 BTU/h at -15 °C (5 °F), with a COP of 2.00. The maximum published capacity is 45,000 BTU/h at -15 °C. The two points are measured separately; we report each one as published.
At -15 °C, the four heads therefore share the 45,000 BTU/h listed by NEEP, and each kilowatt-hour consumed returns two kilowatt-hours of heat, where an electric baseboard returns one. ENERGY STAR's cold-climate designation confirms that the combination meets the low-temperature performance criteria.
These figures come from NEEP's cold-climate heat pump list, for certificate AHRI 210605819.
Backup heat and defrost
The NEEP list gives no point colder than -15 °C. We therefore recommend keeping the existing baseboards, set slightly below the heads' set point: they stay off for most of the winter and take over during extreme cold. In cold, humid weather, the condenser also runs defrost cycles of a few minutes; the heads then stop blowing warm air and a cloud of vapour rises from the outdoor unit. This is normal.
The inverter compressor from one level to the next
The inverter compressor varies its speed according to the demand of the four heads and meters the R-410A refrigerant sent to each one. In winter, the upstairs head often slows down on its own, benefiting from the rising heat, while the basement head works harder. The four heads always work in the same mode, heating or cooling, as on any multi-zone system of this type. Shutting off an unoccupied zone leaves the other three running normally.
Summer: the upper floor for heat, the basement for humidity
In cooling, the system is built around a nominal size of 48,000 BTU/h for the four zones. The upstairs heads carry most of the effort on hot evenings. In the basement, dehumidification mode removes the damp air without needlessly cooling the room. Everywhere, extended low-speed operation makes the air drier and more comfortable.
The certified ratings, in plain terms
- 9.8 HSPF2: heating efficiency over the whole cold season, calculated for a reference climate (region IV); it is used to compare models.
- 21.8 SEER2: cooling efficiency over a whole summer.
- 11.7 EER2: cooling at full load, in hot weather.
- COP: the ratio between heat delivered and electricity consumed at a specific temperature, here 2.30 at -8 °C and 2.00 at -15 °C.
The indicative LogisVert amount: $4,320
The system is listed in Hydro-Québec's LogisVert program, with an indicative amount of $4,320 for the owner of an existing home, according to the list in effect on the installation date. Only Hydro-Québec confirms the amount granted. We check eligibility before signing and prepare the detailed invoice, model numbers and proof of payment. Our page on the efficient heat pump grant summarizes the program's conditions.
An installation over three levels
Lines, drains and commissioning
The condenser is installed where the four line routes are shortest, above the snow line, on a stand or a sturdy bracket, away from snow sliding off the roof. Each head gets its own refrigerant line set: the basement one goes through the foundation wall, the upstairs ones run up the facade in a painted line cover. We show you each route before drilling.
Each head also has its own sloped condensate drain. In the basement, a small condensate pump often becomes necessary for lack of a natural slope; we determine that during the visit. Commissioning includes the vacuum, the leak test, a check of each zone and setup of the four remotes with you.
Maintenance
Rinse the filters of all four heads every two weeks in season, preferably on the same day. Keep the condenser clear of snow and leaves, without covering it in winter. One HVAC maintenance visit per year cleans the coils, fans and drains, checks the condensate pump if there is one and inspects the electrical connections. Our cleaning service takes over when you prefer to hand off the annual visit.
AirGreen, the company behind the installation
A family business active for more than fifteen years in Montreal, Laval, Longueuil, the North Shore and the South Shore, we hold RBQ licences for ventilation, refrigeration and electrical work and carry $5,000,000 in liability insurance. The in-home assessment is free, the quote is in writing, and our financing options let you choose the right unit rather than the cheapest one.
Request your free estimate for the 4-Zone Heat Pump CONFORTO MHMZ | 48,000 BTU - R410A. We assess your three levels and your electrical panel and confirm the right size and check your grant eligibility before signing.
What people ask us about multi-zone systems.
Can I heat one room and cool another at the same time?
No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.
What happens when every room calls for heat?
They share the outdoor unit’s capacity: 36,000 BTU/h at −8 °C, 45,000 at −15 °C.
How many heads can I connect?
Up to 5 on this outdoor unit. This product is configured for 4 heads.
What is the indicative LogisVert amount?
$4,320. It is an indicative amount: only Hydro-Québec confirms the amount granted. The grant never exceeds 100 % of the cost before taxes; apply within 9 months of installation.
Is it ENERGY STAR certified?
Yes, cold climate, ID 2495078.
Down to what temperature does it operate?
Per the brochure, down to −30 °C.
Is it noisy?
Outdoors, 65 dB(A): we place the unit away from bedroom windows.
Why a multi-zone instead of several wall units?
One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.
A multi-zone system is planned at your home, during the visit.
We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.