2-Zone Heat Pump CONFORTO MHMZ | 18,000 BTU - R410A

In stock
SKU: MHMZ218DACFC
18,000BTU/h · 2 heads
−30 °Cheats down to
$1,800LogisVert, indicative
ENERGY STAR® cold climateOptional Wi-FiR-410AUp to 2 heads
Talk to a technician · 514 316-2973
Outdoor unit MHMZ218DACFCPossible indoor models MHWAL09DACFCAHRI 210605810· ENERGY STAR 4480247
In short

The Conforto MHMZ 18 000 multi-zone heat pump heats and cools 2 rooms with a single outdoor unit. ENERGY STAR cold-climate certified, it delivers 15,000 BTU/h at −8 °C, heats down to −30 °C and qualifies for a $1,800 LogisVert grant. Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.

01 · The verdict in 10 seconds

2 rooms, one outdoor unit.

Figures come from the manufacturer’s data and the AHRI certification.

AHRI 210605810
15,000BTU/h at −8 °C
−30 °Cstill heating
2heads
2.5COP at −8 °C
$1,800LogisVert, indicative
02 · The machine

The parts that make a multi-zone system.

Tap a part to learn more.

MHMZ218DACFC

Outdoor unit

One compressor for the whole house. It supplies up to 2 heads.

03 · How it works

Turn rooms on and off. Watch the power being shared.

One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.

04 · My plan

Tell us your rooms. We tell you if this size is enough.

Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide, the real calculation is done room by room at your home.

05 · The series

The whole series at a glance: find the box that fits you.

Each box is a product: the outdoor unit’s size, and the number of heads.

Outdoor2 zones3 zones4 zones5 zones
18,000BTU
Here
27,000BTU
23
36,000BTU
234
48,000BTU
2345

Conforto MHMZ 18 000 · 2 zones

15,000 BTU/h
at −8 °C
$1,800
LogisVert

Up to 2 heads on this outdoor unit. Tap another box to see that size.

06 · Deep cold

At −15 °C, it still delivers 109 % of its rated capacity.

Tap a temperature: capacity, efficiency and the cost of one hour of heating.

07 · The bill

At every temperature, cheaper than baseboards.

Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.

08 · Efficiency

The official ratings, on the same scales as before.

SEER2, HSPF2 and EER2 come from the AHRI certification.

SEER2 · seasonal cooling22.0
Scale 1 – 30
HSPF2 · seasonal heating9.8
Scale 1 – 15
EER2 · cooling in peak heat12.5
Scale 1 – 20
COP at −15 °C1.9
Scale 0 – 4
09 · LogisVert grant

A grant you can calculate, not guess.

15,000 BTU/h÷ 1,000 ×$120=$1,800

The capacity at −8 °C. $120 per 1,000 BTU/h is the rate for ENERGY STAR cold-climate heat pumps (guide v1.10).

Set for this system (AHRI 210605810). Another head combination (ducted, console) can change the AHRI number, and so the amount.
Cap: the grant never exceeds 100 % of the purchase and installation cost before taxes.
9 months after installation to apply; +5 % when two measures are in the same request.
All about LogisVert, with the simulator
10 · Multi-zone or wall units

One multi-zone or several wall units? Both sides, honestly.

This multi-zone2 wall units
On the wall1 outdoor unit2 outdoor units
Electrical1 dedicated circuitOne circuit per unit
CapacityShared between roomsReserved for each room
If the outdoor unit stopsEvery zone stopsOnly one room
ModesSame mode everywhereEach room chooses
LogisVert$1,800 for the systemDepends on each model

We compare both options on your floor plan during the estimate.

11 · Installation

What to know before installing a multi-zone system.

Dimensions, wiring and lines, drawn. Then our six steps.

The outdoor unit, dimensioned

31.90 in
MHMZ218DACFCDepth 16.10 in
37.20 in
Dimensions: product sheet (W × D × H).

One circuit for the whole house

Electrical panel
Load calculation before the quote
25 A max. breaker
MCA 20 A · 220 V
Outdoor unit
Head 1
Head 2
Our RBQ licence covers electrical work (subclass 16).
01Room-by-room visit and surveyWe measure each zone and note insulation and windows. The on-site estimate is free.
02Heads and line layoutOne pair of lines per head.
03Outdoor unit baseAbove the snow line, away from the neighbours’ bedroom windows.
04Exposed, finished linesLines under line covers, no work inside the walls.
05Dedicated circuit220 V, MCA 20 A, 25 A protection. The panel load calculation is done before the quote.
06Commissioning, zone by zoneEach head is tested and the controls set up. Then the LogisVert application within 9 months.
12 · Sound

Published sound levels, on one scale.

We use the outdoor figure to choose where the unit goes.

24
38
61
20 dB(A)3040506070
24 Reference head, lowest speed38 Reference head, highest speed61 Outdoor unit
Values in dB(A). Indoor values are those of the sheet’s reference head; each head has its own, confirmed for the chosen model. Municipal noise by-laws vary by borough.
13 · What sets it apart

What is particular about this machine.

Only facts published by ENERGY STAR, NEEP or the manufacturer.

5,700BTU/h at low speedMinimum certified capacity (NEEP): it slows down instead of stopping when the load drops.
$1,800LogisVert grantAmount for the owner of an existing home, according to Hydro-Québec’s list of October 19, 2026.
150 WBase pan heaterHeater in the outdoor unit’s base pan, against ice (NEEP).
14 · Specifications

Every number, and where it comes from.

Each line carries its source; a line with no published value is not shown.

Performance
Cooling capacity (size)18,000 BTU · 1,5 tonsSheet
SEER2 (seasonal cooling efficiency)22.0AHRI
EER2 (instant cooling efficiency)12.5AHRI
HSPF2 (seasonal heating efficiency, region IV)9.8AHRI
Heating
Capacity at −8 °C15,000 BTU/h · COP 2.5Sheet
Capacity at −15 °C19,700 BTU/h · COP 1.9Sheet
Capacity at -15 °C (max.)20,000 BTU/h · COP 1.83Sheet
Heats down to−30 °CSheet
Zones and heads
Zones on this product2 Zones (Double Zone)Sheet
Maximum zones2 Zones (Double Zone)Sheet
Possible indoor modelsMHWAL09DACFCSheet
Indoor dimensions (W × D × H)33.70 x 9.10 x 11.70 inSheet
Airflow (reference head)340 CFMSheet
Indoor sound (reference head)24 – 38 dB(A)Sheet
Installation
Outdoor unit (W × D × H)37.20 x 16.10 x 31.90 inSheet
Outdoor sound61 dB(A)Sheet
Electrical
Voltage220 VSheet
MCA (minimum circuit ampacity)20 ASheet
MOP (maximum overcurrent protection)25 ASheet
RefrigerantR-410ASheet
Wi-FiEn OptionSheet
Certifications and warranty
AHRI210605810AHRI
ENERGY STARYes · cold climate · ID 4480247Sheet
LogisVert grant (indicative)$1,800Sheet
AirGreen extended warrantyPossibleSheet
15 · Official brochures

The manufacturer’s documentation, as PDF.

16 · Description

Everything we have written about this system.

Two small rooms, two identical heads and a condenser sized to match

Not every home needs a large system. Two bedrooms that overheat in summer, a bedroom and a home office, the two closed rooms of a condo: for these modest needs, the right unit is the one that matches the actual load, not the biggest one. The 2-Zone Heat Pump CONFORTO MHMZ | 18,000 BTU - R410A feeds two wall heads from a single MHMZ218DACFC condenser, compact and sized for two small rooms.

This 1.5-ton condenser serves 2 zones, which is its maximum of 2. The wall head intended for it is the MHWAL09DACFC, installed in each of the two rooms. Its certified ratings are 22.0 SEER2, 12.5 EER2 and 9.8 HSPF2. The system is ENERGY STAR certified with the cold-climate designation under ENERGY STAR ID 4480247, and it qualifies for a $1,800 LogisVert grant.

The right size for two small rooms

A heat pump that is too large for its room heats or cools quickly, stops, then starts again. These short cycles wear out the unit, leave the air humid in summer and create temperature swings. A condenser sized to the rooms instead runs for long periods at low speed, which gives more even comfort and drier air.

This size therefore targets two modest rooms: two bedrooms in a 4 ½ or a 5 ½, a bedroom and an office, a basement bedroom and a workroom. In a well-insulated home, the two heads cover most of the year in these rooms. In an older house, the electric baseboards stay in place for deep cold. The load calculation confirms the choice during the visit.

We are often asked whether a single head, mounted in the hallway between the two rooms, would do the job. With the door open, a little air circulates; with the door closed to sleep or work, almost nothing gets through. One head per room is the only way to guarantee each its own temperature, and that is exactly what a two-zone condenser allows.

Two MHWAL09DACFC heads, two set points

Both rooms get the same head, the MHWAL09DACFC, each with its own remote and set point. You can keep the office comfortable during the day and the bedroom cool at night, or shut off an unoccupied zone entirely without touching the other.

The two heads share the condenser's capacity: when both call at full demand, it is split between them; when only one room is occupied, it benefits from the available capacity. With 2 zones out of a maximum of 2, every connection is used. If a third room needs to be equipped one day, another unit will be required; we tell you before signing, so the choice is made with full knowledge.

Sleep, the first argument

In a bedroom, it is the night that judges a system. The inverter compressor slows down as soon as the set point is reached and holds the temperature without abrupt starts. In summer, extended low-speed operation removes moisture from the air, which lets you sleep cool without setting the set point too low. For cooling, the system is built around a nominal size of 18,000 BTU/h shared between the two rooms.

Compared with a window air conditioner, the difference is clear: the condenser and its compressor are outside, the window stays free and locks, and only a flow of air remains in the room. We mount each head high on the wall so the air sweeps the room without blowing directly on the bed.

In the cold, more capacity than the nominal size

The certificate lists 15,000 BTU/h at -8 °C (17 °F), with a COP of 2.50, and 19,700 BTU/h at -15 °C (5 °F), with a COP of 1.90. It also publishes a maximum capacity of 20,000 BTU/h at -15 °C, with a COP of 1.83. The two points are measured separately; we report each one as published.

The figure at -15 °C exceeds the 18,000 BTU nominal size. This is not an error: in cold weather, the inverter compressor can run faster than its reference speed to offset the home's heat losses. A COP of 1.90 means that at that temperature, each kilowatt-hour consumed returns 1.90 kilowatt-hours of heat, where a baseboard returns one. ENERGY STAR's cold-climate designation confirms that the combination meets the low-temperature performance criteria.

These figures come from certificate AHRI 210605810, published by NEEP.

Backup heat and defrost

The certificate does not publish a point colder than -15 °C. We therefore recommend keeping the existing baseboards, set slightly below the heads' set point: they stay off most of the time and only take over during extreme cold. In cold, humid weather, the condenser also runs defrost cycles of a few minutes. The heads then stop blowing warm air and a cloud of vapour rises from the outdoor unit. This is normal.

Inverter technology and R-410A refrigerant

The condenser meters the R-410A refrigerant sent to each head according to its demand and adjusts the compressor speed accordingly. The two heads always work in the same mode, heating or cooling, as on any multi-zone system of this type. For two neighbouring rooms living through the same season, this rule goes unnoticed.

The 22.0 SEER2, 12.5 EER2 and 9.8 HSPF2 ratings

  • SEER2: cooling efficiency over a whole summer.
  • EER2: cooling at full load, in hot weather.
  • HSPF2: heating efficiency over the whole cold season, the rating that weighs most on the bill in Quebec.
  • COP: the ratio between heat delivered and electricity consumed at a specific temperature, here 2.50 at -8 °C and 1.90 at -15 °C.

The $1,800 LogisVert grant

The system is listed in Hydro-Québec's LogisVert program, with $1,800 for the owner of an existing home, according to the list in effect on the installation date. We confirm eligibility before signing and prepare the detailed invoice, model numbers and proof of payment. Our page on the efficient heat pump grant summarizes the program's conditions.

An installation in a condo or a house

Our installation

In a condo, the condenser's location and drilling through exterior walls often fall under the syndicate's authority; check the declaration of co-ownership and obtain approval before the work. The compact condenser is installed on a balcony, on a wall bracket or on a stand, always above the snow line and sheltered from snow sliding off the roof.

Each head gets its own refrigerant line set back to the condenser, protected by a line cover outdoors, and its own sloped condensate drain. The condenser is connected to a dedicated circuit, checked at the panel during the visit. Commissioning includes the vacuum, the leak test, a check of both zones and setup of the remotes with you.

Maintenance

Rinse the filters of both heads every two weeks in season; they come out by hand, without tools. Keep the condenser clear of snow, ice and leaves, without covering it in winter: it heats in January too. One HVAC maintenance visit per year cleans the coils, fans and drains and checks the electrical connections. Our cleaning service takes over when you prefer to hand off the annual visit.

AirGreen, for the life of the installation

A family business active for more than fifteen years in Montreal, Laval, Longueuil, the North Shore and the South Shore, we hold RBQ licences for ventilation, refrigeration and electrical work and carry $5,000,000 in liability insurance. The in-home assessment is free, the quote is in writing, and our financing options let you choose the right unit rather than the cheapest one.

Request your free estimate for the 2-Zone Heat Pump CONFORTO MHMZ | 18,000 BTU - R410A. We assess your two rooms and confirm the right size and your grant eligibility before signing.

17 · Questions

What people ask us about multi-zone systems.

Can I heat one room and cool another at the same time?

No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.

What happens when every room calls for heat?

They share the outdoor unit’s capacity: 15,000 BTU/h at −8 °C, 19,700 at −15 °C.

How many heads can I connect?

Up to 2 on this outdoor unit. This product is configured for 2 heads.

How much is the LogisVert grant?

$1,800. The grant never exceeds 100 % of the cost before taxes; apply within 9 months of installation.

Is it ENERGY STAR certified?

Yes, cold climate, ID 4480247.

Down to what temperature does it heat?

Down to −30 °C.

Is it noisy?

Indoors, the reference head goes down to 24 dB(A). Outdoors, 61 dB(A): we place the unit away from bedroom windows.

Why a multi-zone instead of several wall units?

One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.

AirGreen

A multi-zone system is planned room by room. At your home.

We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.

RBQ 5645-9605-01Ventilation 15.8, refrigeration 15.10, electrical 16
We handle the circuitOur licence covers the electrical work
LogisVert : $1,800Indicative amount
Beware of scamsHydro-Québec does no phone or door-to-door solicitation for LogisVert
SourcesCosts: Hydro-Québec Rate D, 11.142 ¢/kWh (second tier, since 1 April 2026). Amounts shown are estimates; only the responsible bodies confirm the grant awarded.