131 ft
The shortest reach in the series
The brochure limits the MHMZ218 to 82 ft per head and 131 ft in total. The MHMZ327 goes to 98 and 197 ft; the MHMZ436 and MHMZ548 to 115 and 262 ft.
Multi-zone brochureAirGreen × CONFORTO · Multi-zone · 2 rooms
Two rooms, two lines, four possible outdoor units
Authorized CONFORTO dealer · sold and installed by AirGreen in Montreal, Laval, Longueuil and on the South and North Shores.
CONFORTO Maximum · multi-zone · 2 rooms
For two rooms, our shop sells all four MHMZ heat pumps as dual-zone systems. The smallest, the MHMZ218, has exactly two ports; the MHMZ327 keeps one free, the MHMZ436 two and the MHMZ548 three. Enter your two line lengths and the height difference: the page checks them against the brochure limits and works out the R-410A to add beyond the factory charge.
Updated October 29, 2026 · CONFORTO multi-zone brochure (rev. 15/05/26), MHMZ manual, NEEP, ENERGY STAR and the LogisVert guide
Multi-zone brochure
The line length covered by the factory charge
Two lines of 15 and 25 ft make 40 ft, under the factory charge of all four units. Beyond that charge, 0.16 oz of R-410A is added per foot.
This page answers
Two rooms: is the MHMZ218 enough, or does it take the MHMZ327?
On this page
The CONFORTO shop · 2 zones
From the MHMZ218 to the MHMZ548, each system starts from a Maximum-series outdoor unit; the two heads are decided at your home. Priced by quote.
01 · Your two lines, checked
Pick the outdoor unit, enter the length of each line, from the outdoor unit to the head, then the height difference. The page checks each line, the total and the height, and works out the refrigerant to add when the two lines go past the factory charge.
Outdoor unit
Your two lines, in feet
Outdoor unit position
MHMZ218 · 15 + 25 ft · within the limits · nothing to add See the details
Maximums, height and factory charge: CONFORTO multi-zone brochure, rev. 15/05/26. Its height limit is 15 m when the outdoor unit is above the heads and 10 m when it is below (English edition), converted down to 49.2 and 32.8 ft. Beyond the factory charge, 0.16 oz of R-410A per foot of 1/4 in liquid line. 3 m (9.8 ft) minimum per line: MHMZ manual 615000580 asks for at least 3 m of piping against vibration and noise; applying it to each line is our reading.
MHMZ218 · 2 zones
40ft of piping for both heads
Not in the calculation: the height gap between your two heads, which the MHMZ manual limits to 10 m, and the choice of the two heads, made with you, based on the two rooms.
02 · After two heads
Two figures per unit: the ports still free, and the length of line the factory charge still covers with the tool’s default lines, 15 and 25 ft.
| Outdoor unit | Free ports | Line still covered by the factory charge, after 15 + 25 ft |
|---|---|---|
| MHMZ21818,000 | none | 9 ft |
| MHMZ32727,000 | 1 of 3 | 34 ft |
| MHMZ43636,000 | 2 of 4 | 58 ft |
| MHMZ54848,000 | 3 of 5 | 83 ft |
Ports and factory charge: multi-zone brochure, rev. 15/05/26. Last column: our arithmetic, the factory charge minus the 40 ft of the two default lines.
03 · MHMZ218 or MHMZ327
Per NEEP, the MHMZ327 gives more heat: 26,600 against 15,000 BTU/h at −8.3 °C, 25,000 against 19,700 at −15 °C. Its factory charge covers 25 more feet of line and it keeps one free port. The MHMZ218 is lighter and quieter.
Two ports
Three ports
The amount follows the heat at −8 °C, hence the gap between the two. Only Hydro-Québec confirms the amount granted. The comparison covers the outdoor units, at their published values.
Heat, certificates and amounts: AirGreen product pages, pulled live (NEEP list, AHRI certificates 210605810 and 210605813). Ports, factory charge, lengths, sound and weight: multi-zone brochure. LogisVert rule: participation guide, version 1.10.
04 · Did you know
131 ft
The brochure limits the MHMZ218 to 82 ft per head and 131 ft in total. The MHMZ327 goes to 98 and 197 ft; the MHMZ436 and MHMZ548 to 115 and 262 ft.
Multi-zone brochure49 ft
The MHMZ218 leaves the factory with enough R-410A for 49 ft (15 m) of line. Two 24 ft lines need nothing added; two 25 ft lines already need 0.16 oz.
Multi-zone brochure61 dB(A)
The MHMZ218 weighs 149 lb gross and the brochure gives it 61 dB(A). The other three weigh 180 to 270 lb and range from 62 to 65 dB(A).
Multi-zone brochure05 · Questions
Both take two heads. Per NEEP, the MHMZ218 gives 19,700 BTU/h at −15 °C and the MHMZ327 25,000; the 327 also covers more line with its factory charge and keeps one free port. The choice is made during the on-site assessment, based on the two rooms and the line routes.
NEEP list; multi-zone brochureOn the MHMZ218, no: both its ports are taken. The other three keep at least one free port, but a free port is not enough on its own: neither the brochure nor the MHMZ manual says how many BTU/h of heads an outdoor unit can supply. So AirGreen commits to no extra head before seeing the house.
Multi-zone brochure; MHMZ manual 61500058049 ft for the MHMZ218, 74 ft for the MHMZ327, 98 ft for the MHMZ436 and 123 ft for the MHMZ548, counting both lines end to end. Beyond that, 0.16 oz of R-410A is added per foot, since every liquid port is 1/4 in.
Multi-zone brochurePer the NEEP list, 15,000 BTU/h rated at −8.3 °C (19,000 at most) and 19,700 BTU/h at −15 °C (20,000 at most). NEEP lists nothing lower; the brochure gives −30 °C as the low end of its heating operating range.
NEEP list (AHRI certificate 210605810); multi-zone brochureIn our shop, the indicative amount depends on the heat pump: $1,800 for the MHMZ218, $3,192 for the MHMZ327, $3,960 for the MHMZ436 and $4,320 for the MHMZ548. Hydro-Québec reserves the aid for owners and works it out from the heat at −8 °C, at $120 per 1,000 BTU/h for an ENERGY STAR cold-climate heat pump; only Hydro-Québec confirms the amount granted.
LogisVert participation guide, version 1.10; AirGreen product pagesPricing is by quote. The in-home estimate is free, with no commitment.
AirGreen · Air conditioning & heating
We measure the path of both lines to the outdoor unit, choose the two heads with you, then you get the quote. The estimate is free.
LogisVert amounts are indicative: only Hydro-Québec confirms the amount granted. Priced by quote; free in-home estimate.