SENVILLE LETO and AURA R454B 12,000 BTU, figure by figure

Home / Comparisons / 12,000 BTU wall heat pumps

Comparison · Wall heat pump · 12,000 BTU

SENVILLE LETO and SENVILLE AURA R454B: what the cold-weather certificate shows

Two 12,000 BTU SENVILLE wall units, both on R-454B and 208/230 V. Their AHRI certificates do not stop at the same place: the last point published by NEEP is at −15 °C for the LETO and at −30 °C for the AURA. This page shows what each record contains, point by point, and what the ENERGY STAR criteria require for the “cold climate” designation.

Refrigerant : R-454B and R-454BColdest certified point : −15 °C and −30 °CSEER2 21.3 and 25.4HSPF2 Region V 7.0 and 8.0ENERGY STAR cold climate : no and yes
SENVILLE LETO 12,000 BTU (AirGreen image) SENVILLE

LETO 12,000 BTU, 220 V

SENL-12CD220-ILL / SENL-12CD220-OL · AHRI 215735289

Also offered in 115 V, under another certificate (AHRI 215735287).

View the product page
8.3 °C −8.3 °C −15 °CLETO −30 °CAURA

NEEP certified points, warmest to coldest.

SENVILLE AURA R454B 12,000 BTU (AirGreen image) SENVILLE

AURA R454B 12,000 BTU

SENA-12HF-IGG / SENA-12HF-OG · AHRI 215735296

Same NEEP certified values as the MIDEA28, the DIRECT AIR HEAT XTREME PRO R-454B and the BOSCH MAX PERFORMANCE R-454B.

View the product page
Estimated operating cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for the same 12,000 BTU/h zone in Montréal, at Hydro-Québec Rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the point of reference.

How this amount is calculated
  1. Heat needed over the winter. A zone whose heat loss reaches 12,000 BTU/h ( kW) at −23.1 °C, Montréal’s design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for round-the-clock heating, all winter. Heating degree-days (18 °C base) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day (the “Heating” slider), the heat is reduced in the same proportion, for the heat pump and the baseboards alike: this is a simplification that ignores the recovery after a temperature setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 12,000 BTU/h ÷ SEER2 × hours a day × 60 days ÷ 1,000: the method of Hydro-Québec’s air conditioning calculator, with the seasonal SEER2 efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day long: that is a maximum, since a variable-speed unit slows down once the room is at the right temperature.
  4. Price. Hydro-Québec Rate D in effect on April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ beyond that; the average price, 9.104¢, is the one offered by Hydro-Québec’s calculators. GST and QST included. The system access charge, the same with or without a heat pump, is not counted.

AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The actual bill depends on the house, the insulation, the settings and how it is used; this amount is not a promise.

The winter gap comes from the certified HSPF2 Region V: 7.0 for the LETO, 8.0 for the AURA. This seasonal coefficient already accounts for cold days and the electric backup assumed by the standard.

What the cold-weather certificate shows

Two NEEP records on the same temperature scale

Move the thermometer down. At every temperature where NEEP publishes a point, it appears on the chart. Below −15 °C, the LETO record has no more points: its last point stays on screen, with the range SENVILLE advertises. The AURA record adds one at −30 °C.

8.3 °C
8.3−8.3−15−20−25−30 °C

LETO SENVILLE

AURA R454B SENVILLE

ENERGY STAR “cold climate” criteria, line by line

Thresholds published by ENERGY STAR for a non-ducted split heat pump; values from each unit’s AHRI certificate, read on NEEP. Yellow tick: the threshold.

Capacity kept at −15 °CMaximum capacity at −15 °C ÷ rated capacity at 8.3 °C · threshold: 70%
LETO67%
AURA96%
8,000 ÷ 12,000 and 11,500 ÷ 12,000 BTU/h
COP at −15 °CAt maximum capacity · threshold: 1.75
LETO1.91
AURA1.80
HSPF2 Region IVCold-climate threshold, non-ducted: 8.5
LETO9.1
AURA10.5
SEER2Threshold: 15.2
LETO21.3
AURA25.4
EER2Basic ENERGY STAR criterion for split systems · threshold: 11.0
LETO10.8
AURA13.4
LETO · NEEP record 385692: ENERGY STAR no, cold climate no. No listing in the ENERGY STAR directory for AHRI 215735289.
AURA · NEEP record 385685: ENERGY STAR yes, cold climate yes. ENERGY STAR directory: certified on May 6, 2026.

This grid restates the criteria published by ENERGY STAR. The certification itself is granted by ENERGY STAR, which also requires a controls verification at −15 °C; the result is the one shown in the NEEP records and the directory above.

Extreme cold

Below −15 °C: every published number, at its exact temperature

At −15 °C, both records have a certified point: 8,000 BTU/h maximum for the LETO, 11,500 for the AURA. Lower down, only the AURA has one, at −30 °C. In between, the page shows the range of the two published values, without calculating anything between them.

What SENVILLE publishes below −15 °C. LETO: the manufacturer’s page lists heating “down to −15 °C (5 °F)” and gives no figure lower down. AURA: the page lists heating down to −30 °C (−22 °F), with no capacity table by temperature; the point certified by NEEP at −30 °C is the only figure published below −15 °C. We found no low-temperature capacity table for either model; promotional percentage claims are not repeated here.
Documented features

What SENVILLE writes for each, group by group

LETO: manufacturer’s page SENL-12CD/220 (senville.ca). AURA: manufacturer’s page SENA-12HF (senville.com). The two pages do not describe the same things: when a page is silent, the card says so.

Heating range

LETO : “heating down to −15 °C (5 °F)”.

AURA : heating down to −30 °C (−22 °F); minimum outdoor heating temperature −30 °C in the specification table.

Remote and app

LETO : remote control; control through Alexa and the app, multi-room management.

AURA : wireless remote, voice control and the Alexa app through an included USB kit.

Modes

LETO : dehumidification, fan, Turbo and Sleep mode.

AURA : cooling, heating, dehumidification and fan.

Refrigerant leak and self-diagnosis

LETO : not published on the manufacturer’s page.

AURA : built-in self-diagnosis and refrigerant leak detection.

Inverter compressor

LETO : “DC inverter” technology.

AURA : not described on the page; the specification table gives a heating range of 4,000 to 14,500 BTU/h.

Fan at its lowest

LETO : 22.5 dB at low speed; Sleep mode.

AURA : 24 dB at the lowest setting.

Dehumidification

LETO : 1.5 L/h.

AURA : 1.4 L/h.

ENERGY STAR certification

LETO : not certified per NEEP; the manufacturer’s page does not mention it.

AURA : certified, with the cold climate designation (NEEP and the ENERGY STAR directory).

Refrigerant pre-charge

LETO : pre-charged for 25 ft; 16 ft installation kit.

AURA : pre-charged for 25 ft; 16, 25 or 50 ft kits, the last one requiring refrigerant added on site.

Sound

Four fan speeds each, published the same way

SENVILLE publishes both indoor units at four speeds (Turbo, high, medium, low) and one value for each outdoor unit. The pages do not describe the measurement conditions.

dB(A)

How to read these numbers. The decibel measures a noise level: the lower the number, the quieter the unit. Each dot is a published fan speed, from slowest to fastest.

Why this is not a ranking. The airflows are not the same: 359 CFM in Turbo for the LETO, 530 for the AURA. A fan that moves more air is usually louder at its top speed, and the measurement distance is not published.

Indoor unit, in the room

The four published speeds

Outdoor unit, outside

One published value per unit

Measurements taken by each manufacturer using its own method: read them separately, not as a ranking.

Installation

On the wall and outside: widths, weights, wiring

Indoor units, photos at the same width scale

LETO31.57 in wide
SENVILLE LETO indoor unit
31.57 in · 802 mm
AURA33.4 in wide
SENVILLE AURA indoor unit
33.4 in · 848 mm
36 in

0 in24 in48 in

Widths published by SENVILLE. The comparison only accounts for the cabinet width: the side clearance to allow is in the installation manual and is confirmed during the visit.

Outdoor units seen from the front, scale drawing

30.12 in30.31 in LETO59.08 lb AURA82.67 lb 21.85 in21.65

Drawing: cabinets drawn at the same scale from the published dimensions (width × height). The AirGreen product-page photos of both models show the same outdoor-unit illustration; the drawing gives each one’s own dimensions and weight.

InstallationLETOAURA R454B
Indoor unit W × H × D, weight31.57 × 11.69 × 7.44 in, 19.4 lb33.4 × 11.76 × 9.18 in, 24.25 lb
Outdoor unit W × H × D, weight30.12 × 21.85 × 11.93 in, 59.08 lb30.31 × 21.65 × 12.20 in, 82.67 lb
Precharged length25 ft25 ft
Maximum piping lengthNot published by the manufacturerNot on the product page consulted.Not published by the manufacturerNot on the product page consulted.
Maximum height differenceNot published by the manufacturerNot published by the manufacturer
Refrigerant chargeNot published by the manufacturerR-454B, 40.92 oz
Electrical protectionAccording to the manufacturerMCA 13 A; maximum fuse 15 AMCA 12 A; maximum fuse 15 A
Heating capacity min. / max., per the manufacturerPublished range, no test temperature stated2,400 / 12,200 BTU/h4,000 / 14,500 BTU/h
Cooling capacity min. / max., per the manufacturer1,700 / 13,300 BTU/h3,500 / 13,500 BTU/h
Indoor airflow, Turbo / high / medium / low359 · 306 · 206 · 144 CFM530 · 410 · 320 · 240 CFM
Dehumidification1.5 L/h1.4 L/h
Advertised heating rangeDown to −15 °C (5 °F)Down to −30 °C (−22 °F)

SENVILLE, SENL-12CD/220 page (senville.ca) and SENA-12HF page (senville.com), accessed November 10, 2026. Airflows are rounded to the CFM (LETO: 359.0 / 306.1 / 206.0 / 144.2). Clearances around the outdoor unit are not on these pages: they are in the installation manual and are checked during the visit.

Frequently asked questions

What people ask about these two SENVILLE units

Why doesn't the LETO carry the “cold climate” designation?

Its NEEP record shows “no” for ENERGY STAR and for cold climate. On the published criteria, two certificate values are below the threshold: at −15 °C, its maximum capacity of 8,000 BTU/h is 67% of its rated capacity at 8.3 °C, against a 70% threshold; its EER2 is 10.8, against a basic threshold of 11.0. Its COP at −15 °C (1.91), its HSPF2 and its SEER2 are above the thresholds.

And below −15 °C, with the LETO?

SENVILLE lists the LETO’s heating “down to −15 °C” and publishes nothing lower down; neither does NEEP. The page therefore shows its last point, 8,000 BTU/h at −15 °C, without extending the curve. For the AURA, NEEP certifies a point at −30 °C: 5,900 BTU/h maximum.

At −8.3 °C, which one heats more?

At that temperature, NEEP certifies 9,300 BTU/h maximum for the LETO and 12,800 for the AURA. The COPs at maximum capacity are 2.39 and 1.75: they are two different points on each unit’s curve, to be read together with their capacity.

115 V or 220 V?

The 12,000 BTU LETO comes in 115 V and in 208/230 V, under two different certificates: 215735287 (115 V: SEER2 21.2, HSPF2 Region V 6.7) and 215735289 (220 V: SEER2 21.3, HSPF2 Region V 7.0). This page compares the 220 V version, like the AURA, offered in 208/230 V.

Does the AURA go by other names?

On NEEP, the MIDEA28 (AHRI 215471381), the DIRECT AIR HEAT XTREME PRO R-454B (216571373) and the BOSCH MAX PERFORMANCE R-454B (215223282) have the same certified values as the 12,000 BTU AURA. Each brand’s indoor units, remotes and documents may differ.

Which one costs less to run?

With the method in the “Cost per season” section, round-the-clock heating and the average price, the estimate is $437 per winter for the LETO and $382 for the AURA, against $896 with baseboards. These amounts change with the sliders; they are for comparing, not for predicting a bill.

Are they eligible for grants?

Eligibility depends on the official list in effect on the purchase date. This page promises no amount; the current list is checked when the quote is prepared.

Certified data

All AHRI and NEEP values

Certified valueLETOAURA R454B
Cooling
35 °C: min. / rated / max.BTU/h1,700 / 12,000 / 13,3003,800 / 12,000 / 13,500
SEER221.325.4
EER210.813.4
Heating, same conditions
HSPF2 Region IV / V9.1 / 7.010.5 / 8.0
8.3 °C: min. / rated / max.BTU/h3,500 / 12,000 / 13,4003,800 / 12,000 / 16,000
8.3 °C: COP min. / rated / max.3.11 / 3.17 / 2.914.84 / 3.74 / 3.35
−8.3 °C: min. / rated / max.BTU/h1,100 / 9,300 / 9,3005,300 / 12,000 / 12,800
−8.3 °C: COP min. / rated / max.1.07 / 2.39 / 2.392.22 / 2.51 / 1.75
−15 °C: min. / rated / max.BTU/h700 / 8,000 / 8,0004,100 / 11,500 / 11,500
−15 °C: COP min. / rated / max.0.76 / 1.91 / 1.911.72 / 1.80 / 1.80
Coldest point — different temperatures, not highlighted
Test temperature−15 °C (5 °F): no colder point on the record−30 °C (−22 °F)
Capacity min. / max.700 / 8,000 BTU/h2,000 / 5,900 BTU/h
COP at maximum capacity1.911.25
Certifications and refrigerant
ENERGY STAR / cold climate (NEEP)No / NoYes / Yes
AHRI certificate · NEEP record215735289 · 385692215735296 · 385685
RefrigerantGWP per the IPCC (AR4); ASHRAE 34 classR-454B · GWP 466 · A2LR-454B · GWP 466 · A2L

higher marks the higher value of the same measurement, under the same conditions. It is not a recommendation. Capacities and COPs at each point are not highlighted: the order changes depending on the point.

Both are on the AirGreen website.

To choose for your home, talk to our team: bring the width of the planned wall, the outdoor location and the coldest temperature you want to cover.