GENERAL AIRSTAGE UART Cable for Gas Sensor – UTYXWZXZL
The genuine GENERAL AIRSTAGE cable for the UART connection of a gas sensor in a refrigerant leak detection system.
AirGreen codeAG-AC-110
514 316-2973 · sales@airgreen.ca
Quick facts
In a refrigerant leak detection system, the GENERAL AIRSTAGE UTYXWZXZL UART cable is the OEM part that connects the gas sensor. It is the same part under the Fujitsu AIRSTAGE brand: Fujitsu General Limited, now owned by Paloma Rheem Holdings, renamed itself GENERAL Inc. on January 1, 2026, without touching the model numbers. The acronym UART refers to a serial communication link: this cable is how the sensor and the unit pass their signals to each other.
A link that is part of the unit’s safety
When the unit runs on an A2L refrigerant such as R-32, leak detection is one of its safeguards. The sensor still has to stay in touch with the unit: a faulty link makes it useless. So we install the cable the manufacturer provides, not a generic connector. Sometimes no external cable is needed at all: the manufacturer indicates that several R-32 AIRSTAGE units, for example the ARUH ducted units and the AMUH units, have their sensor built in.
The information to send us
Before ordering the cable, we validate the installation from this information:
- the model number of each unit, indoor and outdoor, read from its nameplate
- the unit’s refrigerant, as displayed on the nameplate (R-32, R-410A…)
- where possible, a photo of the spot where the unit sits
Routing, connection and testing
The cable routing follows the unit’s manual, and we test the detection system once the connection is complete. A unit with A2L refrigerant requires a qualified technician for any work.
AirGreen, everywhere in Greater Montréal
AirGreen’s team of refrigeration technicians works on GENERAL or Fujitsu AIRSTAGE units in Montréal, Laval, Longueuil, on the North Shore and on the South Shore. All our service calls are carried out under RBQ licence 5645-9605-01. Pass on your model numbers at 514 316-2973 or sales@airgreen.ca, and we will tell you whether the cable is available or send you a quote.
The link between the sensor and the unit
A gas sensor only protects if it talks to the equipment: this genuine cable makes that link.
- Connecting a GENERAL or Fujitsu gas sensor to the equipment
- Replacing a damaged cable in an existing detection system
- R-32 installations that call for external leak detection
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- Send us the unit and sensor model numbers before ordering.
- Cable routing must follow the equipment manual.
- Some R-32 AIRSTAGE units have a built-in sensor, per the manufacturer: an external cable is not always needed.
- Work on A2L refrigerant equipment is reserved for a qualified technician.
You may also need
GENERAL AIRSTAGE Leak Detection System Accessory – UTYSGZU
GENERAL AIRSTAGE Extension Kit – UTZJUXA
GENERAL AIRSTAGE Shut-Off Valve Kit for R-32 Leak Detection
Fujitsu Leak Detection System Accessory – UTYSGZU
Hitachi 5-Wire Adapter for 24 V Thermostat – C3STAT01
Hitachi C1STAT01 5-Wire Thermostat Adapter (airHome)
Hitachi Port Adapter for airHome RAM-G Multi-Zone
Hitachi PSC-6RAD H-Link Adapter for airHome Indoor UnitOriginal partsSee all
Frequently asked questions
Does my installation need it?
Only if it includes an external gas sensor to connect. Several R-32 AIRSTAGE units have a built-in sensor per the manufacturer. Send us your model numbers and we check.
Is it compatible with my unit?
We confirm compatibility with the manufacturer from your units’ model numbers, before any order.
Can I use a generic cable?
We do not recommend it: leak detection is a safety function, and we fit the part the manufacturer designed.
Can you install it?
Yes. Our technicians connect the cable and test the detection system, everywhere in Greater Montréal.
The genuine cable for your GENERAL or Fujitsu gas sensor
Tell us the size and the quantity: we confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on October 7, 2026.