THERMO 2000 VoltMax SCR VOLTSCR20845P3 Commercial Electric Boiler | 45 kW - 208V 3 Phase

In stock

The 208 V three-phase VoltMax 45 delivers 45 kW, or 153,540 BTU/h, to the heating loop of an apartment building or condominium, with SCR modulation from 0 to 100%.

Model numberVOLTSCR20845P3

45 kW153,540 BTU/h
125.1 Aat 208 V three phase
QuietSCR solid-state relays, per Thermo 2000
208 V · three phaseOutdoor sensor includedMulti-unit
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberVOLTSCR20845P3
ManufacturerThermo 2000
Output45 kW (153,540 BTU/h)
Power supply208 V, three phase, 60 Hz
Current125.1 A
Setpoint range50 °F to 200 °F
Thermo 2000 warrantyTank 10 years · components 2 years

45 kW for the heating loop of your apartment building or condominium

The VoltMax 45 on 208 V three phase

Thermo 2000 designs the VoltMax for commercial, institutional and multi-unit buildings heated with water. The 45 kW model, on 208 V three phase, produces 153,540 BTU/h and draws 125.1 A. It belongs to the series’ configuration A, from 22.5 to 90 kW.

It suits rental buildings and condominiums in Montreal, Laval or Longueuil whose units are heated by a central loop: radiators, hot water baseboards, radiant floors in lobbies and common areas. A second setpoint also makes it possible to feed an indirect water heater.

Occupant comfort, season after season

In an apartment building, the boiler works for occupants who never see it. The included outdoor sensor lets the Schneider Electric controller adjust the water temperature to the weather, within a 50 °F to 200 °F setpoint range: lukewarm water in the fall, hotter in the depth of winter. Schedules can also adjust heating in common areas.

Output follows the demand. SCR solid-state relays vary it from 0 to 100%, in addition to relay stages that the controller rotates, and Thermo 2000 points out that this modulation limits peak power demand. The manufacturer describes its boiler as quiet, clean and low maintenance, which matters when the mechanical room is next to an apartment.

For the property manager or condo board, the controller’s Ethernet port provides a web page and email alarms, and the 3 in backlit screen shows alarm codes in French or English.

What installation by AirGreen covers

The on-site estimate is free in Montreal, Laval, Longueuil, on the North Shore and on the South Shore. We assess the building’s heating load, the 208 V three-phase service and the condition of the central loop. The written quote, which the board or owner uses to decide, includes the circulator and expansion tank, which are not among the parts supplied by Thermo 2000.

Our technicians install the boiler with the required clearances (24 in in front, 32 in above, 3 in on the sides and at the back), connect it through its 1 1/2 in NPT connections, pipe the relief valve discharge and mount the outdoor sensor in a representative spot. They make the electrical connection, fill and purge the loop, then program the controller and the property manager’s email addresses.

AirGreen is a family business established in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. Thermo 2000 covers the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years.

Let’s talk about your building

To replace or install your building’s central boiler, ask for a free estimate. We give you a written quote, and financing is available.

01 · What it is for

The central boiler of an apartment building

In a rental building or condominium heated with hot water, the VoltMax 45 feeds the central loop that serves each unit. The included outdoor sensor sets the water temperature to the weather.

  • Rental buildings and condominiums on 208 V three phase
  • Central loops serving radiators or hot water baseboards in each unit
  • Radiant floors in lobbies and common areas
  • Indirect water heater connected to the second setpoint
Comfort that follows the weatherThe included outdoor sensor lets the controller adjust the water through the seasons, within a 50 °F to 200 °F setpoint range.
Quiet and cleanThermo 2000 describes the VoltMax as quiet and low maintenance, an advantage near apartments.
SCR modulation from 0 to 100%Output follows the building’s demand; according to the manufacturer, peak power demand is limited.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerThermo 2000
Manufacturer designationVoltMax 45, SCR series (VOLTMAX SCR 45-208-3 PH)
TypeCommercial hot water electric boiler
Output45 kW
Output in BTU/h153,540 BTU/h
Power supply208 VAC, 60 Hz, three phase
Current125.1 A
ModulationSCR from 0 to 100% (solid-state relay) plus relay stages
Setpoint range50 °F to 200 °F (10 °C to 93 °C)
Water volume11 US gal (41.6 L)
Water connections1 1/2 in male NPT, 4 side connections
Relief valve and drain3/4 in female NPT
ControllerSchneider Electric, 3 in backlit LCD, alarm codes, °C/°F, French/English
CommunicationBACnet IP / MS-TP; Ethernet port with web page and email alarms
External controlSetpoint and output by 0-10 Vdc signal
Outdoor sensorIncluded (outdoor reset)
Domestic hot water2nd setpoint for an indirect water heater; pump contact with or without DHW priority
Low water cut-offOptional up to 60 kW (standard above)
ClearancesSides 3 in, back 3 in, front 24 in, top 32 in, floor 0
Weight310 lb (141 kg)
ConfigurationA (22.5 to 90 kW)
Manufacturer warrantyThermo 2000: 10 years on the tank (limited warranty, closed-loop heating); 2 years on electrical and mechanical components (parts and accessories)
StandardsCSA C22.2 No. 165-92, UL 834, CSA B-51-14, ASME Section IV (H), CRN
Model numberVOLTSCR20845P3
03 · Before installing

What to know before installing

  • 208 V three-phase, 60 Hz supply, for a current of 125.1 A; the protection and conductors are sized by the electrician.
  • In a condominium, work in the shared mechanical room is planned with the board: our written quote supports its decision.
  • The circulator and expansion tank are not among the parts supplied by Thermo 2000; we choose them for the building’s loop.
  • Clearances: 24 in in front, 32 in above, 3 in on the sides and at the back, none at the floor.
  • Low water cut-off optional on this size; it is standard above 60 kW.
  • Weight of 310 lb (141 kg), to plan for when accessing the mechanical room.
In the box
  • Schneider Electric controller with backlit display
  • Outdoor temperature sensor
  • Control ON/OFF switch
  • Control and power fuses and breakers
  • SCR relays
  • 2 limit controls, one automatic, one manual
  • Factory-installed relief valve
  • Drain valve
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Electric boilers
See all
Same brand
THERMO 2000
See all
06 · Questions

Frequently asked questions

Is a 45 kW VoltMax enough for our building?

It depends on the building’s heat loss, not only on the number of units. We assess the load during the free estimate and propose the right size: the 208 V three-phase VoltMax comes in several outputs.

Will occupants hear the boiler?

Thermo 2000 describes the VoltMax as quiet: its output goes through SCR solid-state relays. We also choose the circulator with this in mind.

How does heating adapt to the seasons?

With the included outdoor sensor, the controller adjusts the water temperature to the weather. Schedules can also adjust heating in common areas.

Who is alerted when an alarm occurs?

The controller sends its alarms by email to the programmed addresses, such as the property manager’s. On site, the 3 in backlit screen shows the alarm code in French or English.

What warranty does Thermo 2000 offer?

10 years on the tank (limited warranty, closed-loop heating) and 2 years on electrical and mechanical components, parts and accessories.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 45 kW VoltMax for your building, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 19, 2026.