THERMO 2000 VoltMax SCR VOLTSCR24072P1 Commercial Electric Boiler | 72 kW - 240V 1 Phase

In stock

Thermo 2000’s VoltMax 72 delivers 72 kW on 240 V single phase, with output that an external system can control through a 0-10 Vdc signal.

Model numberVOLTSCR24072P1

72 kW245,664 BTU/h
300 Acurrent on 240 V single phase
0-10 Vdcsetpoint and output controlled externally
240 V · single phaseLow water cut-off includedOutdoor sensor includedElectrical service to be confirmed
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberVOLTSCR24072P1
ManufacturerThermo 2000
Manufacturer designationVOLTMAX SCR 72-240-1 PH
Output72 kW (245,664 BTU/h)
Power supply240 V, 1 ph, 60 Hz
Current300 A
Elements12 x 6 kW

72 kW on 240 V single phase, with output your building can control

The largest 240 V single-phase size

Some large buildings heated with hot water only have a single-phase supply: a large apartment building in Laval, a commercial building on the North Shore, an old building expanded over the years. Thermo 2000’s VoltMax 72 is designed for them. Among the 240 V single-phase sizes we offer in the VoltMax SCR series, it is the largest: 72 kW, or 245,664 BTU/h according to the manufacturer.

It heats the water loop that feeds radiators, radiant floors or hydro-air coils, and its second setpoint can serve an indirect water heater, with or without domestic hot water priority.

300 A: a load to plan for

Thermo 2000 publishes a current of 300 A for this model. On a single-phase service, that is a very large load, and it is the first thing we check. If the margin is not there, you have two options: a smaller size in the series, such as the 66 kW or 60 kW VoltMax, if the heating load allows it, or an increase in the building’s electrical capacity.

Once the boiler is in place, its output stays under control. The solid-state relay (SCR) varies it from 0 to 100%, which, according to Thermo 2000, limits peak power demand. An external system, such as a building management system, can also send it a setpoint and output through a 0-10 Vdc signal, or communicate with it over BACnet IP or MS-TP.

What the boiler includes

Above 60 kW, Thermo 2000 installs a low water cut-off as standard, which interrupts heating if the water level drops. Two limit controls (automatic and manual), the factory-installed relief valve, control and power fuses and breakers, the outdoor sensor and the Schneider Electric controller complete the delivery. The controller shows alarm codes in French or English, and its Ethernet port gives access to a web page and email alarms.

Heating relies on 12 replaceable 6 kW Incoloy immersion elements, run in stages that the controller rotates. The unit is vertical and compact: 3 in of clearance on the sides and back, 24 in at the front, 32 in above, 310 lb (141 kg) and 11 US gal of water. The circulator and expansion tank are added to the quote.

AirGreen’s installation

We start with a free on-site estimate, including a review of the electrical loads, then you receive a written quote. Our technicians install the boiler, connect it to the loop through its 1 1/2 in male NPT side connections, make the electrical connection, mount the outdoor sensor, fill and purge the system, check the safety devices and set up the controller.

AirGreen is a family business established in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. Thermo 2000 covers the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years.

Let’s start with the estimate

We install the VoltMax SCR in Montreal, Laval, Longueuil, on the North Shore and on the South Shore. Ask for your free estimate: you receive a written quote, and financing is available.

01 · What it is for

The largest 240 V single-phase VoltMax size

Among the 240 V single-phase VoltMax SCR sizes we offer, the VoltMax 72 is the largest. It heats the water loop of a large building that has no three-phase supply, provided the electrical service can carry its 300 A.

  • Large apartment or commercial buildings without a three-phase supply
  • Buildings where an electrical load management system must control the boiler
  • Radiators, radiant floors and hydro-air coils
  • An indirect water heater on the second setpoint
Controllable outputThe setpoint and output can follow a 0-10 Vdc external signal, and the solid-state relay modulates from 0 to 100%.
Standard low water cut-offFactory-installed on sizes above 60 kW, along with two limit controls and the relief valve.
12 elements of 6 kWReplaceable Incoloy immersion elements, run in stages that the controller rotates.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerThermo 2000
SeriesVoltMax SCR, configuration A (22.5 to 90 kW)
Manufacturer designationVOLTMAX SCR 72-240-1 PH
TypeCommercial hot-water electric boiler with SCR modulation
Output72 kW
Output in BTU/h245,664 BTU/h
Power supply240 VAC, 60 Hz, single phase
Current300 A
Heating elements12 x 6 kW, immersion type, Incoloy, replaceable
ModulationSCR from 0 to 100% (solid-state relay) and relay stages, with stage rotation
Setpoint range50 °F to 200 °F (10 °C to 93 °C)
ControllerSchneider Electric, 3 in backlit LCD, alarm codes, °C/°F, French or English
CommunicationBACnet IP / MS-TP, Ethernet port with web page and email alarms
External controlSetpoint and output by 0-10 Vdc signal
Outdoor sensorIncluded (outdoor temperature reset)
Domestic hot waterPump contact with or without priority, 2nd setpoint for an indirect water heater
Low water cut-offStandard (above 60 kW)
Water volume11 US gal (41.6 L)
Water connections1 1/2 in male NPT, 4 side connections
Relief valve and drain3/4 in female NPT
ClearancesSides 3 in, back 3 in, front 24 in, top 32 in, floor 0 in
Weight310 lb (141 kg)
Manufacturer warrantyThermo 2000: 10 years on the tank (limited warranty, closed-loop heating); 2 years on electrical and mechanical components (parts and accessories)
StandardsCSA C22.2 No. 165-92, UL 834, CSA B-51-14, CRN, ASME Section IV (H)
Model numberVOLTSCR24072P1
03 · Before installing

What to know before installing

  • 240 V single-phase, 60 Hz power supply and a current of 300 A according to Thermo 2000: a very large load for a single-phase service. We confirm it before any order.
  • If the service is not large enough, a smaller size in the series or an increase in electrical capacity should be considered.
  • The circulator and expansion tank are not among the supplied parts.
  • Clearances: 3 in on the sides and back, 24 in at the front, 32 in above, 0 in at the floor.
  • Weight: 310 lb (141 kg); the unit holds 11 US gal of water.
In the box
  • Schneider Electric controller with backlit display
  • Outdoor temperature sensor
  • Low water cut-off
  • On/off control switch
  • Control and power fuses and breakers
  • SCR relay
  • 2 limit controls (automatic and manual)
  • Factory-installed relief valve
  • Drain valve
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Electric boilers
See all
Same brand
THERMO 2000
See all
06 · Questions

Frequently asked questions

Can our electrical service take this boiler?

Thermo 2000 publishes a current of 300 A for this model on 240 V single phase. During the free estimate, we review the building’s loads. If the margin is not there, we suggest a smaller size in the series or an increase in electrical capacity.

Can the boiler’s output be controlled?

Yes. The setpoint and output can follow a 0-10 Vdc external signal, for example from a building management system. The controller also communicates over BACnet IP or MS-TP, and the solid-state relay modulates output from 0 to 100%.

Is the low water cut-off supplied?

Yes. Thermo 2000 installs it as standard on VoltMax models above 60 kW, including this 72 kW model.

How many heating elements does it contain?

12 replaceable 6 kW Incoloy immersion elements. The controller rotates the order of the relay stages.

What warranty does Thermo 2000 offer?

A 10-year limited warranty on the tank, for closed-loop heating, and 2 years on electrical and mechanical components.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 240 V single-phase VoltMax 72, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 19, 2026.