Élios Heating Element for GPHLA Extra-Slim Fan Coil

In stock

The original long, slim heater kit built for the Élios GPHLA slim ceiling fan coil.

AirGreen codeAG-AC-01101

3 to 10 kW4 nominal ratings
3.9 inthick, made for the slim unit
208-230 Vsingle phase, 60 Hz
Backup heatGenuine part
Model
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

AirGreen codeAG-AC-01101
BrandÉlios
Part no.EAH03DUL, EAH05DUL, EAH08DUL, EAH10DUL
ForÉlios GPHLA slim fan coils (18,000 to 36,000 BTU)
Power208-230 V, 1 ph, 60 Hz

The Élios EAHxxDUL series heating element is made for the GPHLA extra-slim fan coil, the thin ducted unit that hides in a drop ceiling or an attic. It adds electric auxiliary heat of 3, 5, 8 or 10 kW nominal, at 208-230 V single-phase, and keeps the unit's slim profile: 28.74 × 3.9 × 7.48 in and 1.8 kg.

Auxiliary heat where there is no room for an air handler

In a condo, a renovation or a floor with no mechanical room, the GPHLA distributes air through short ducts from the ceiling. The DUL element supplements the heat pump when it needs extra heat. Élios lists it as an optional accessory in the submittal sheets for the GPHLA18, GPHLA24, GPHLA30 and GPHLA36.

Sizes listed by Élios

  • 5, 8 and 10 kW: for all four sizes, from 18,000 to 36,000 BTU.
  • 3 kW: for the GPHLA18, GPHLA30 and GPHLA36; it does not appear in the GPHLA24 sheet.

Built-in relay, protection at the panel

The manufacturer's drawing shows a relay on each DUL element, with no breaker. Circuit protection is therefore provided at the panel, based on the maximum value (MOCP) in the sheet: 20 A for the 3 kW up to 50 A for the 10 kW, at 230 V. Actual output also varies with voltage; the 10 kW delivers 9 kW at 230 V and 7.4 kW at 208 V. The values for each size are shown when you select it.

Installed by AirGreen in Greater Montréal

We install the element in your GPHLA and check the auxiliary heat in Montréal, Laval, Longueuil, on the South Shore and the North Shore; the power circuit is done by a master electrician. RBQ licence 5645-9605-01. For availability or a quote, call us at 514 316-2973 or email sales@airgreen.ca with the unit model, the output and the quantity.

01 · What it is for

Backup heat in a ceiling-mounted unit

The GPHLA hides in a dropped ceiling or an attic; the DUL kit has the slim shape that fits inside.

  • Backup heat for an Élios system with a GPHLA slim fan coil
  • Unit installed in a dropped ceiling, a soffit or an attic
  • Renovations with no room for an upright air handler
  • Replacing a DUL-series heater
Slim formatThe kit measures 28.74 × 3.9 × 7.48 in and weighs 1.8 kg in every rating.
Built-in relayThe manufacturer’s drawing shows a relay on every DUL kit; no circuit breaker is shown.
Single stageEach model heats in one stage: 2.75 to 9 kW actual output at 230 V.
Compatible with
GPHLA18R4AS1GPHLA24R4AS1GPHLA30R4AS1GPHLA36R4AS1
Per the manufacturer. Send us your unit’s model number and we confirm before ordering.
02 · Sizes

4 sizes, one page

Each size has its own AirGreen code. Tap a row to select it.

ModelActual output at 208 / 230 VCurrent at 208 / 230 VMCA at 208 / 230 VMax. overcurrent protection (MOCP) at 208 / 230 VNet weightCompatible air handlersPart no.AirGreen code
3 kW – EAH03DUL2.26 / 2.75 kW11 / 12.5 A14 / 16 A15 / 20 A1.8 kg (4 lb)GPHLA18, GPHLA30 and GPHLA36EAH03DULAG-AC-01101
5 kW – EAH05DUL3.76 / 4.54 kW18.5 / 20 A23.5 / 25 A25 / 30 A1.8 kg (4 lb)GPHLA18, GPHLA24, GPHLA30 and GPHLA36EAH05DULAG-AC-01102
8 kW – EAH08DUL5.9 / 7.1 kW29 / 31.5 A36.5 / 40 A40 / 45 A1.8 kg (4 lb)GPHLA18, GPHLA24, GPHLA30 and GPHLA36EAH08DULAG-AC-01103
10 kW – EAH10DUL7.4 / 9 kW36.5 / 40 A46 / 50 A50 / 50 A1.8 kg (4 lb)GPHLA18, GPHLA24, GPHLA30 and GPHLA36EAH10DULAG-AC-01104

Nominal output. Actual values at 208 V and 230 V are in the table for the size you pick.

03 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

BrandÉlios
TypeElectric heater kit (backup heat)
SeriesEAHxxDUL
ModelsEAH03DUL, EAH05DUL, EAH08DUL, EAH10DUL
Power208-230 V, 1 ph, 60 Hz
Heating stages1
ComponentRelay
Net dimensions (W × D × H)28.74 × 3.9 × 7.48 in
Net weight1.8 kg (4 lb)
UnitsÉlios GPHLA18R4AS1, GPHLA24R4AS1, GPHLA30R4AS1, GPHLA36R4AS1
Actual output at 208 / 230 V2.26 / 2.75 kW
Current at 208 / 230 V11 / 12.5 A
MCA at 208 / 230 V14 / 16 A
Max. overcurrent protection (MOCP) at 208 / 230 V15 / 20 A
Net weight1.8 kg (4 lb)
Compatible air handlersGPHLA18, GPHLA30 and GPHLA36
Part no.EAH03DUL
AirGreen codeAG-AC-01101
04 · Before installing

What to know before installing

  • The 3 kW kit is not listed on the GPHLA24 submittal: use 5, 8 or 10 kW for that size.
  • No breaker appears on the DUL drawing: plan circuit protection at the panel, per the MOCP on the sheet.
  • The 10 kW kit needs 50 A MCA and 50 A max. overcurrent protection at 230 V.
  • The supply circuit is done by a licensed electrician, with the unit powered off.
05 · Documents

Manufacturer documents

06 · Goes with

You may also need

Same category
Original parts
See all
07 · Questions

Frequently asked questions

Which kit fits my GPHLA?

The Élios submittals list the 5, 8 and 10 kW kits for all four sizes, 18,000 to 36,000 BTU, and the 3 kW kit for the GPHLA18, GPHLA30 and GPHLA36. Send us your unit’s model number and we confirm before ordering.

Is it the same kit as for the GGHLA wall-mount air handler?

No. The GGHLA takes the EAHxxCUL series. The DUL series is longer and thinner, made for the GPHLA.

Does the kit have its own breaker?

The manufacturer’s DUL drawing shows only a relay. The circuit is protected at the electrical panel, per the max. overcurrent protection listed for each rating.

Can you install it?

Yes. We fit the kit in the GPHLA and check the backup heat; the supply circuit is run by a licensed electrician, everywhere in Greater Montréal.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

Original backup heat for your GPHLA

Tell us the size and the quantity: we confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 7, 2026.