Samsung Hylex Heating Element Kit for MPAH Module
Genuine Samsung heat kits that add backup heat to the MPAH air handler of a Hylex heat pump.
AirGreen codeAG-AC-02001
514 316-2973 · sales@airgreen.ca
Quick facts
Samsung Hylex heating element kits add electric auxiliary heat to the multi-position modules (MPAH) of the R-454B Hylex™ lineup. Samsung offers them as an option for the HH**M**C11H1 modules, paired with standard and premium Hylex™ outdoor units.
The backup that completes a central heat pump
In extreme cold or while the outdoor unit is shut down, the element takes over. The ACU MXD-U001XN control module, required with Hylex MPAH modules, runs the auxiliary heat in one or two stages (terminals W1 and W2) depending on its settings. We offer three outputs: 10 kW (HA10E0CH1), 15 kW (HA15E0CH1) and 20 kW (HA20E0CH1).
Compatibility with the MPAH module
The allowed output varies from one module to another. For example, Samsung lists elements from 5 to 20 kW for the HH48MCCC11H1 module and from 7 to 20 kW for the HH60MACC11H1. Samsung also specifies that the HH24MCAC11H1 must not take the 10 kW element in a downflow configuration.
Electrical connection
- For the 15 and 20 kW elements, Samsung offers the HA15B0CH1 single-point breaker kit.
- The connection follows the instructions supplied with the element and the electrical code.
- The work is done by a master electrician.
Installed by AirGreen in Greater Montréal
We install Samsung Hylex systems and their auxiliary heating elements in Montréal, Laval, Longueuil, on the South Shore and on the North Shore. RBQ licence 5645-9605-01. For availability or a quote, call us at 514 316-2973 or email sales@airgreen.ca with your MPAH module model and the output you need.
Backup electric heat for the Hylex heat pump
Samsung offers these kits as optional supplemental heat for Hylex MPAH air handlers.
- Backup heat for an R-454B Samsung Hylex™ heat pump
- Standard and premium Hylex™ multi-position air handlers (HH**M**C11H1)
- Emergency heat when the outdoor unit is off
- Replacing an electric furnace with a central heat pump
3 sizes, one page
Each size has its own AirGreen code. Tap a row to select it.
| Model | Part no. | Nominal output | HA15B0CH1 single point breaker kit | AirGreen code |
|---|---|---|---|---|
| 10 kW – HA10E0CH1 | HA10E0CH1 | 10 kW | Not listed by Samsung for this model | AG-AC-02001 |
| 15 kW – HA15E0CH1 | HA15E0CH1 | 15 kW | Available for this model | AG-AC-02002 |
| 20 kW – HA20E0CH1 | HA20E0CH1 | 20 kW | Available for this model | AG-AC-02003 |
Nominal output as listed by Samsung. The allowed size depends on the MPAH.
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- The allowed size depends on the MPAH: Samsung lists 5 to 20 kW for the HH48MCCC11H1 and 7 to 20 kW for the HH60MACC11H1, for example.
- Per Samsung, the HH24MCAC11H1 must not be used with the 10 kW kit in downflow configuration.
- The ACU control unit MXD-U001XN is mandatory with Hylex MPAH air handlers.
- Follow the instructions supplied with the kit and have a licensed electrician make the connection.
Manufacturer documents
You may also need
Samsung Single Point Breaker Kit – HA15B0CH1
Samsung Hylex ACU Control Module MXD-U001XN
Samsung Advanced Wired Controller – MWR-WG01UN
Copper Electrical Wire
Outdoor Disconnect Switch for Heat Pump
Fujitsu Leak Detection System Accessory – UTYSGZU
GENERAL AIRSTAGE Leak Detection System Accessory – UTYSGZU
Hitachi 5-Wire Adapter for 24 V Thermostat – C3STAT01Original partsSee all
Frequently asked questions
Which kit fits my Hylex air handler?
It depends on the MPAH model; Samsung lists the allowed kits on each air handler’s submittal. Send us the model number (HH…C11H1) and we confirm before ordering.
What is the HA15B0CH1 for?
Samsung describes it as a single point breaker kit for the 15 and 20 kW heat kits.
Does the kit work without the ACU?
Hylex MPAH air handlers require the MXD-U001XN ACU control unit; it runs the backup heat stages (W1, W2).
Can you install it?
Yes. We fit the kit in the air handler and coordinate the connection with a licensed electrician, everywhere in Greater Montréal.
Genuine backup heat for your Hylex
Tell us the size and the quantity: we confirm availability and send you a quote. Or let our technicians install it for you.