The Samsung parts a Hylex install needs.
Some are required by Samsung: the
- Hylex™ ACU Control KitMXD-U001XNRequired on every Hylex
- A2L Mitigation ControllerHA00A00203H1Required with an HC coil
- Electric Heat KitsHA05E0CH1 · HA07E0CH1 · HA10E0CH1 · HA15E0CH1 · HA20E0CH1Optional, 5 to 20 kW
- URK-3A Relay Kit for Hylex™ SystemsURK-3AFor a PSC motor
Samsung Hylex
Required, optional or accessory: each part has its job.
Seven Samsung parts. We plan them in the quote when your install needs them: nothing hidden.
Where each part goes in the house.
A Hylex install, from the thermostat to the outdoor unit. Tap a number: we tell you what the part does, and whether it is required.
RequiredOptionTo planSuppliedSystem
Control unit (ACU)
It goes between the outdoor unit, the thermostat and the indoor unit or furnace. Samsung requires it on every Hylex and sells it separately. Wi-Fi included.
A2L mitigation controller
With an HC coil on your furnace, the coil’s detector needs this controller to shut the system down and run mitigation. The HH unit already has its own.
Heat kits
They slide into the HH unit for backup heat, 5 to 20 kW depending on the model. With an HC coil, your furnace takes over in deep cold.
Single-point breaker kit
For the 15 and 20 kW kits: it lets them be fed from a single point. Samsung offers it without requiring it.
Float switch input
CN950With a store-bought condensate pump, its float switch plugs in here, on the wire supplied with the ACU. If water rises, the Hylex stops and SmartThings alerts you, per Samsung.
External contact module
Turns on the outdoor unit’s night quiet mode from an external contact, and provides run and error outputs.
24 V thermostat
1 or 2 stagesThe ACU follows the signals of a 24 VAC thermostat. Samsung recommends a 2-stage model.
Advanced controller
Connected to the ACU’s F3/F4, it lets you control the Hylex from the app. With a 24 V thermostat alone, the app monitors only.
Hylex outdoor unit
AC0**FCU*CGStandard or Premium, 2 to 5 tons. It talks to the ACU over two 18 AWG wires, up to 100 m.
Tap a number on the illustration.
Source: Samsung Hylex submittals (04072026, 05052026);
Your Hylex, part by part.
Pick your setup: the list builds itself with Samsung part numbers, and what is required is marked.
Greyed-out sizes are not listed in Samsung’s submittal for the selected HH unit, or are ruled out in downflow.
In downflow, Samsung rules out the 10 kW kit on 24,000 BTU/h units: it is greyed out.
Source: Samsung Hylex submittals with HH unit (04072026) and with coil (05052026); manual 679608-01; ACU manual
Every part: when you need it, and what’s in the box.
The seven Samsung parts side by side, with their exact names. Pick your setup: what applies to you stays lit. Where Samsung publishes nothing, the cell says so.
| Part | When | In the box | Published data | Document |
|---|---|---|---|---|
| Required, sold separatelyRequired, sold separatelyRequired, with another brand’s air handler too | The ACU and its Wi-Fi module, the module holder, 2 cable ties, 5 M4 × 16 screws, 5 holder locks, 24 U-rings, the fan speed control wire, the Wi-Fi extension wire, the float switch wire, the manual and the wire label | 24 VAC only, 3 W max; up to 100 m (328 ft) from the outdoor unit; 2.4 GHz Wi-Fi, channels 1 to 11 in Canada; 24 DIP switches, 10 of them reserved | ||
| Not needed: the HH unit has detection and mitigation built inRequired, sold separately: the detector is in the coilNot listed: a field-supplied detector sends its alarm to the ACU at 24 VAC | not published | No sheet, wiring or sequence published | Samsung | |
| Optional, backup heat inside the HH unitNot applicable: with an HC coil, your furnace is the backupNot listed for another brand’s air handler | Not published; the brochure titles its table “w/ Breaker” | 5, 7, 10, 15 and 20 kW per the submittal; | Submittal 04072026; brochure HYLEXBR 02.2026-V2 | |
| Offered for the 15 and 20 kW kits, without a “mandatory” labelNot applicableNot applicable | not published | not published | Submittal 04072026 | |
| Not listed: the HH unit has its own speed tapsFor a PSC motor without two cooling inputs; never with a gas furnaceFor a PSC motor without two cooling inputs | not published | No technical data published | ||
| Optional: night quiet mode, run and error outputsOptional: same usesOptional: night quiet mode | The board, its case, one harness per wire and 2 screws | 3 1/8 × 2 in; 5 V, 5 mA input; 220 VAC, 3 A outputs | ||
| Optional: without it, the app only monitorsOptional: same rulesOptional: same rules | not published | 12 VDC, 2 W; 2 wires F3/F4; details on the Thermostats page | 10232024 |
- A sheet, wiring or sequence for the
HA00A00203H1 and theURK-3A . - Electrical data for each heat kit, and whether the kits come with their breaker.
- The ACU’s labelled dimensions and operating temperature.
- A warranty specific to the parts: Samsung’s warranty is explained once, on the Samsung page.
Sources: ACU manual
The MXD-U001XN ACU, terminal by terminal.
A Hylex’s brain fits in a small box, held by four magnets near the indoor unit. Tap a terminal block: we tell you what connects there.
RequiredOptionTo planSuppliedSystem
Thermostat terminals
R · C · Y1 · Y2 · W1 · W2 · G · D · O/BR and C: 24 VAC, from the indoor unit’s transformer. Y1 and Y2: the compressor, 1 or 2 stages. W1 and W2: backup heat. G: the blower. D: dehumidification, optional. O/B: reversing.
To the outdoor unit
F1 · F2Two 18 AWG solid-core communication wires, up to 100 m (328 ft) between the outdoor unit and the ACU.
To the wired control
F3 · F4For the
Leak alarm (RDS)
IN · NO · COM · NCIN: leak alarm input, 24 VAC, for another brand’s detector. NO and NC: two alarm outputs, one normally open, one normally closed, with their common terminal COM.
Float switch input
CN950The wire supplied with the ACU plugs into this 2-pin port (dry contact) and takes the float switch of a condensate pump. If water rises, the system stops and SmartThings alerts you, per Samsung.
SW1 switch
It sets electric backup to 1 or 2 stages. With a 2-stage heat kit, both stages are enabled here, per the manual.
Wi-Fi module
2.4 GHz onlySupplied with the ACU, with its holder. Per the manual: 2.4 GHz Wi-Fi only, channels 1 to 11 in Canada, a network name with letters and numbers only. We check your network at install.
Tap a number on the illustration.
Maximum ACU power draw, per Samsung. It takes 24 VAC only.
From R to O/B: for a 1- or 2-stage 24 V thermostat.
Maximum distance between the outdoor unit and the ACU.
Samsung recommends a 2-stage thermostat with the ACU.
Blinks: 0.5 s on, 0.5 s off. To enter it, press the Easy setup button for 5 seconds.
Blinks: 1.5 s on, 0.5 s off.
Stays on.
All lights go off, and the system keeps its previous mode.
Source: Samsung
The thermostat calls, the ACU answers: play both parts.
Each thermostat terminal sets something off in the Hylex. Turn on Y1, Y2, W1 or W2 and watch what starts, with an HH unit or on your furnace.
The ACU answers
At start-up, Samsung says to allow at least 3 minutes for all the kit’s sequencers to cycle on, and up to 5 minutes to cycle off: shown here sped up.
For dual fuel, Samsung calls for a Samsung communicating control or a 24 V thermostat that supports it.
An illustration of the logic Samsung publishes, not a wiring diagram. With a 2-stage heat kit, both stages are enabled on the ACU (
Source:
24 tiny switches, and the answer to “why is it doing that?”
On the ACU, three rows of DIP switches set the fan, the condensate pump and the leak alarm. Pick what you notice and the switch behind it lights up.
The fan waits before blowing in heating
- Off: enabled · default
- On: disabled
That’s cold-air prevention: at the start of heating, the fan stays off for up to 5 minutes while the coil warms up. It starts sooner if high pressure reaches 269 psi.
It keeps blowing after it stops
- 0 s · default
- 30 s
- 60 s
- 90 s
The fan keeps going for a while to clear the leftover heat. If the indoor unit has no such feature, or the fan runs through G1, G2 and G3, Samsung recommends 30 s.
The fan starts earlier and stops later
- 0 s · default
- 5 s
- 10 s
- 15 s
A delay for defrost and cold-air prevention. If the indoor unit has no such feature, or the fan runs through G1, G2 and G3, Samsung recommends 10 s.
During defrost, the air stops (or not)
- Off: fan off
- On: fan on
With the fan off, no cold air blows into the house during defrost. We pick the setting for your indoor unit.
In summer, the air is drier
- Off: enabled · default
- On: disabled
When the thermostat calls for dehumidification, the ACU pushes cooling harder. Samsung warns the thermostat may then cycle off and on more often.
There’s a condensate pump
- Off: disabled · default
- On: enabled
A store-bought pump is enabled here. Its float switch plugs into the CN950 input, with the supplied wire: if water rises, the system stops and alerts you.
Another brand’s detector sends its alarm
- Off: normally open (recommended)
- On: normally closed
Normally open: 24 V reaches the alarm terminal when there’s a leak. That’s the setting Samsung recommends.
24 V thermostat or Samsung control?
- Off: 24 V thermostat
- On: Samsung 2-wire control
With the Samsung control, its built-in sensor runs the temperature, by default.
Three fan speeds
- On/On or Off/Off: the thermostat decides · default
- Off/On: 3 speeds, Y only
- On/Off: 3 speeds, Y1 and Y2
The ACU can run three speeds. The logic is further down, in “Three speeds”.
Yellow dashes:
Illustration: the real layout differs. We set these switches at start-up, for your indoor unit.
Source:
Three fan speeds, even on a PSC motor.
The ACU can run three fan speeds. Depending on your indoor unit’s motor, that takes two cooling inputs, or Samsung’s
The ACU runs three fan speeds on most air handlers and furnaces, per Samsung. The colours line up: yellow, blue and red for G1, G2 and G3.
Out of the factory: yellow, blue and red on taps 1, 2 and 3. For more airflow on second-stage cooling or in heating, the red wire moves to tap 4 or 5. In downflow, it goes on tap 5.
No relay: the ACU uses the unit’s two cooling inputs, per Samsung.
Without two cooling inputs, Samsung calls for the
Samsung: the relay kit is not compatible with gas furnaces.
With a 1-stage thermostat, two short cycles in a row means: off within 30 minutes of starting, then back on within 20 minutes of stopping.
Source: Hylex
Built-in detector, or a separate controller?
HC24MCB021H1 HC36MBB021H1 HC36MCC021H1 HC48MBC021H1 HC60MCD021H1 HC60MBC021H1 HC60MAD021H1
A2L refrigerants are heavier than air: the sensor sits where they would collect, per UL.
Charge limits aim for dilution well below the flammability limit, with a factor of 4, per UL.
The HH unit label: leak detection installed, the unit must stay powered except for service.
Source: Samsung Hylex submittals with coil (05052026) and with HH unit (04072026); manual 679608-01; Samsung coil and
A leak is detected. Who in the house finds out?
The sensor doesn’t beep: its signal goes to other parts of the system. Pick your setup, then run the drill and follow the signal, part by part.
The sensor is replaced after 10 years, per Samsung: safety standards don’t allow calibrating it in the field.
The animation order is not a timeline: Samsung publishes no timing for the HC coil.
The
Source: Hylex coil (05052026) and
A window opens, the wall unit stops.
On a wall unit, an FJM head or a CAC unit, the
Hotel key card, door or window switch, occupancy sensor: these are Samsung’s examples, not separate modes.
Samsung lists it for the outdoor unit’s night quiet mode, and for run and error outputs.
220 VAC, 3 A relays: one follows operation, the other, normally closed, opens on error.
If you want an alarm, the
5 V, 5 mA input; 3 1/8 × 2 in enclosure, with bracket, for indoor use. On a wall unit, Samsung requires the
The wall unit runsThe wall unit stops
By default, contact closed: the indoor unit runs; contact open: it stops. The behaviour can be changed with installation options, per Samsung.
Source: Samsung
Samsung makes the parts. AirGreen sets them up on your Hylex.
A Hylex has more parts than you’d think. Samsung numbers them; we plan them, install them and set up the ACU.
What SAMSUNG brings
- The
MXD-U001XN ACU3 W max, four magnets, Wi-Fi and nine thermostat terminals. - Coil mitigationThe
HA00A00203H1 , for all seven HC coils in the line. - Five heat kits5 to 20 kW for the HH unit, with the
HA15B0CH1 kit offered for 15 and 20 kW. - Contacts when needed
MIM-B14U for night quiet mode and run and error outputs;URK-3A for a PSC motor.
What AirGreen brings
- Sold and installed by AirGreenThe visit, the quote, the install and start-up.
- The ACU set at start-upBackup stages, fan, condensate pump, leak alarm: we set its switches for your equipment.
- The thermostat picked with youA two-stage 24 V model, as Samsung recommends, or the
MWR-WG01UN for app control. - All in the quoteRequired parts are there from the start, with their Samsung numbers.
- RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16.
These apply to the whole range, or have their own page: we don’t repeat them here.
Hylex parts, in six claims.
True or false? Each card flips to its source.
The ACU is required, even with Samsung’s own indoor unit.
The
The HC coil has no leak detector.
The
The ACU can shut the Hylex down if condensate water rises.
Samsung gives two ratings for the same
What people ask about Samsung parts.
Yes. Samsung requires it on every Hylex system, even with a Samsung indoor unit. It is sold separately.
No: the ACU supports 2.4 GHz Wi-Fi only, per its manual. We check your network at install.
The ACU and its Wi-Fi module, with the module holder, 2 cable ties, 5 M4 × 16 screws, 5 holder locks, 24 U-rings, the fan speed control wire, a Wi-Fi extension wire, the float switch wire, the manual and a wire label, per Samsung. The float switch itself is bought separately.
The
No, they are optional. For 15 or 20 kW, Samsung offers the
Yes: 1 or 2 stages, per Samsung, which recommends a 2-stage thermostat.
Yes. For downflow, Samsung calls for a kit:
Only if your indoor unit has a PSC motor and no two cooling inputs, per Samsung. It is not compatible with gas furnaces, and Samsung’s HH unit doesn’t need it.
Yes: per Samsung, it must be replaced after 10 years, and safety standards don’t allow calibrating it in the field.
No question matches. Call us: 514 316-2973.
These parts go on a Hylex. Here are the units.

Hylex central heat pumps
Standard and Premium, 2 to 5 tons, on your ducts.
See the collection
Hylex electric furnaces
The Hylex indoor unit in place of an electric furnace.
See the collection
“Add-on” central systems
A Hylex coil on the furnace you keep.
See the collection
SAMSUNG wall-mounted heat pumps
WindFree Standard and Max Heat, 9,000 to 24,000 BTU/h.
See the collection
2, 3 or 4-head multi-zone
FJM Premium: up to 4 rooms on one outdoor unit.
See the collection
SAMSUNG ducted units
Slim duct hidden in a ceiling or closet.
See the collection
SAMSUNG ceiling cassettes
WindFree mini 4-way cassette, 2 × 2 ft.
See the collection
SAMSUNG floor consoles
Low on the wall, often under a window.
See the collection
SAMSUNG thermostats and Wi-Fi
Wired controllers and Wi-Fi adapter.
See the collectionThe right parts, planned from the quote.
We tell you what your Samsung system needs, and we install it.
Hydro-Québec does no phone or door-to-door solicitation for LogisVert. A call “from Hydro-Québec” selling a heat pump? Hang up.


Sources checked on October 26, 2026
- Samsung HVAC Hylex
R-454B spec sheets (2026), Hylex brochure (HYLEXBR 02.2026-V2) andMXD-U001XN control unit installation manual. - Samsung HVAC Individual Wired Controls (
MWR-SH12UN ,MWR-WG01UN ) andMIM-H04UN pages, and their submittals. - airgreen.ca product pages, Oct. 8, 2026.
- Samsung Hylex
R-454B submittals with HH unit (04072026) and with coil (05052026); HH unit manual 679608-01 (March 2026);MXD-U001XN ACU manual (DB68-13653A-00 );MIM-B14 /MIM-B14U sheet (SHA-DVMS-07212023 ). - UL Solutions, “Inspecting Refrigerant Detection Systems in HVAC Equipment” (Oct 21, 2024) and “Updated Requirements for Refrigerant Detection Systems” (UL 60335-2-40).
- Samsung
MXD-U001XN ACU manual (DB68-13653A-00 ), p. 6, 11, 14, 17, 22 to 27 and 36, re-read Oct. 26, 2026; Hylex PremiumAC036FCUPCG outdoor unit sheet (02112026), p. 2, 4 and 5, re-read Oct. 26, 2026. - Samsung
MIM-B14 /MIM-B14U sheet (SHA-DVMS-07212023 ) and manualDB68-12292A , re-read Oct. 26, 2026; HylexR-454B outdoor unit manual (DB68-13654A ), p. 9; Samsung HVAC FAQ, re-read Oct. 26, 2026.
Prices on quote.
Samsung parts, right below.
Each product page gives the part number and its use.