AirGreen × SAMSUNGMXD-U001XN: required on every HylexHA00A00203H1: required with an HC coilHeat kits from 5 to 20 kWURK-3A: three speeds on a PSC motorSold and installed by AirGreenMontréal · Laval · Longueuil · Rive-Sud · Rive-Nord
01 · The parts

Required, optional or accessory: each part has its job.

Seven Samsung parts. We plan them in the quote when your install needs them: nothing hidden.

02 · The map

Where each part goes in the house.

A Hylex install, from the thermostat to the outdoor unit. Tap a number: we tell you what the part does, and whether it is required.

Upper floorBasementHH unit (or furnace + HC coil)Hylex outdoor unit

RequiredOptionTo planSuppliedSystem

Required

Control unit (ACU)

MXD-U001XN

It goes between the outdoor unit, the thermostat and the indoor unit or furnace. Samsung requires it on every Hylex and sells it separately. Wi-Fi included.

Tap a number on the illustration.

Source: Samsung Hylex submittals (04072026, 05052026); MXD-U001XN ACU manual (DB68-13653A); MIM-B14U sheet (SHA-DVMS-07212023); Samsung Hylex parts pages. Illustration, not an install plan.

03 · My parts list

Your Hylex, part by part.

Pick your setup: the list builds itself with Samsung part numbers, and what is required is marked.

Indoor side
Line
Tonnage
Heat kit
Position
Control
Quiet mode by contact

Greyed-out sizes are not listed in Samsung’s submittal for the selected HH unit, or are ruled out in downflow.

Source: Samsung Hylex submittals with HH unit (04072026) and with coil (05052026); manual 679608-01; ACU manual DB68-13653A; brochure HYLEXBR 02.2026-V2 (7.5 kW). The list is a starting point: the final quote depends on the visit.

04 · Samsung plate

Every part: when you need it, and what’s in the box.

The seven Samsung parts side by side, with their exact names. Pick your setup: what applies to you stays lit. Where Samsung publishes nothing, the cell says so.

Hylex parts
PartWhenIn the boxPublished dataDocument
MXD-U001XN“Hylex™ ACU Control Kit for R-454B Hylex Systems”Required, sold separatelyRequired, sold separatelyRequired, with another brand’s air handler tooThe ACU and its Wi-Fi module, the module holder, 2 cable ties, 5 M4 × 16 screws, 5 holder locks, 24 U-rings, the fan speed control wire, the Wi-Fi extension wire, the float switch wire, the manual and the wire label24 VAC only, 3 W max; up to 100 m (328 ft) from the outdoor unit; 2.4 GHz Wi-Fi, channels 1 to 11 in Canada; 24 DIP switches, 10 of them reservedDB68-13653A-00
HA00A00203H1“Mitigation Controller for Hylex™ A-coils”Not needed: the HH unit has detection and mitigation built inRequired, sold separately: the detector is in the coilNot listed: a field-supplied detector sends its alarm to the ACU at 24 VACnot publishedNo sheet, wiring or sequence publishedSamsung HA00A00203H1 page; submittal 05052026
HA05E0CH1 · HA07E0CH1 · HA10E0CH1 · HA15E0CH1 · HA20E0CH1“Electric Heat Kits for Hylex™ MPAH Units”Optional, backup heat inside the HH unitNot applicable: with an HC coil, your furnace is the backupNot listed for another brand’s air handlerNot published; the brochure titles its table “w/ Breaker”5, 7, 10, 15 and 20 kW per the submittal; HA07E0CH1 at 7.5 kW per the brochure; electrical data not publishedSubmittal 04072026; brochure HYLEXBR 02.2026-V2
HA15B0CH1“Single point breaker kit for 15kW and 20kW electric heat kits”Offered for the 15 and 20 kW kits, without a “mandatory” labelNot applicableNot applicablenot publishednot publishedSubmittal 04072026
URK-3A“URK-3A Relay Kit for Hylex™ Systems”Not listed: the HH unit has its own speed tapsFor a PSC motor without two cooling inputs; never with a gas furnaceFor a PSC motor without two cooling inputsnot publishedNo technical data publishedAC036FCUPCG outdoor unit sheet (02112026)
MIM-B14U“External Contact Control Module”Optional: night quiet mode, run and error outputsOptional: same usesOptional: night quiet modeThe board, its case, one harness per wire and 2 screws3 1/8 × 2 in; 5 V, 5 mA input; 220 VAC, 3 A outputsSHA-DVMS-07212023 ; DB68-12292A
MWR-WG01UN“Advanced Wired Controller”Optional: without it, the app only monitorsOptional: same rulesOptional: same rulesnot published12 VDC, 2 W; 2 wires F3/F4; details on the Thermostats page10232024
What Samsung does not publish
  • A sheet, wiring or sequence for the HA00A00203H1 and the URK-3A.
  • Electrical data for each heat kit, and whether the kits come with their breaker.
  • The ACU’s labelled dimensions and operating temperature.
  • A warranty specific to the parts: Samsung’s warranty is explained once, on the Samsung page.

Sources: ACU manual DB68-13653A-00 (p. 6, 12, 15, 23 and 24, 37 and 41); Hylex coil (05052026), HH unit (04072026) and AC036FCUPCG outdoor unit (02112026) submittals; brochure HYLEXBR 02.2026-V2; MIM-B14U sheet (SHA-DVMS-07212023) and manual DB68-12292A; Samsung Hylex parts pages. The MRS-L32U, the slim duct’s optional R-32 detector, is not a Hylex part.

05 · The control unit

The MXD-U001XN ACU, terminal by terminal.

A Hylex’s brain fits in a small box, held by four magnets near the indoor unit. Tap a terminal block: we tell you what connects there.

MXD-U001XN · ACU24 VAC thermostatRCY1Y2W1W2GDO/BOutdoorF1F2ControlF3F4Leak alarm (RDS)INNONCFloat switchCN950DIPSW1Wi-Fi 2.4 GHz

RequiredOptionTo planSuppliedSystem

Thermostat

Thermostat terminals

R · C · Y1 · Y2 · W1 · W2 · G · D · O/B

R and C: 24 VAC, from the indoor unit’s transformer. Y1 and Y2: the compressor, 1 or 2 stages. W1 and W2: backup heat. G: the blower. D: dehumidification, optional. O/B: reversing.

Tap a number on the illustration.

3 WPower draw

Maximum ACU power draw, per Samsung. It takes 24 VAC only.

9Thermostat terminals

From R to O/B: for a 1- or 2-stage 24 V thermostat.

100 mTo the outdoor unit

Maximum distance between the outdoor unit and the ACU.

2 stagesRecommended

Samsung recommends a 2-stage thermostat with the ACU.

The ACU’s Wi-Fi light

Blinks: 0.5 s on, 0.5 s off. To enter it, press the Easy setup button for 5 seconds.

Blinks: 1.5 s on, 0.5 s off.

Stays on.

All lights go off, and the system keeps its previous mode.

Source: Samsung MXD-U001XN control unit installation manual (DB68-13653A-00), p. 11, 12, 15, 22, 36 to 41; Hylex coil submittal (05052026). Illustration: the actual terminal layout differs.

06 · The ACU at work

The thermostat calls, the ACU answers: play both parts.

Each thermostat terminal sets something off in the Hylex. Turn on Y1, Y2, W1 or W2 and watch what starts, with an HH unit or on your furnace.

Your setup
SW1-1Off · heat pumpOn · furnace + A-coil, dual fuel
Backup stages
SW1-2Off · stage 1On · stage 2
The thermostat calls

An illustration of the logic Samsung publishes, not a wiring diagram. With a 2-stage heat kit, both stages are enabled on the ACU (SW1-2). With the MWR-WG01UN, Samsung adds finer dual-fuel and backup settings.

Source: MXD-U001XN ACU manual (DB68-13653A-00), p. 11, 17, 23 and 25; HH unit manual 679608-01, p. 8, 9 and 24; brochure HYLEXBR 02.2026-V2, p. 6-7 (note 1); Hylex HH unit submittal (04072026).

07 · The switches

24 tiny switches, and the answer to “why is it doing that?”

On the ACU, three rows of DIP switches set the fan, the condensate pump and the leak alarm. Pick what you notice and the switch behind it lights up.

What you notice

Illustration: the real layout differs. We set these switches at start-up, for your indoor unit.

Source: MXD-U001XN ACU manual (DB68-13653A-00), p. 14, 22 to 27.

08 · Three speeds

Three fan speeds, even on a PSC motor.

The ACU can run three fan speeds. Depending on your indoor unit’s motor, that takes two cooling inputs, or Samsung’s URK-3A relay kit. Pick your unit, then play an hour of fan.

Your indoor unit

The ACU runs three fan speeds on most air handlers and furnaces, per Samsung. The colours line up: yellow, blue and red for G1, G2 and G3.

An hour of fan, three-speed setting
LowMediumHigh

With a 1-stage thermostat, two short cycles in a row means: off within 30 minutes of starting, then back on within 20 minutes of stopping.

Source: Hylex AC036FCUPCG outdoor unit sheet (02112026), p. 4 and 5; MXD-U001XN ACU manual (DB68-13653A-00), p. 11, 23, 25 and 26; HH unit manual 679608-01, p. 24; Samsung “URK-3A Relay Kit for Hylex™ Systems” page.

09 · R-454B safety

Built-in detector, or a separate controller?

R-454B is an A2L refrigerant. With Samsung’s HH unit or HC coil, the detector is built in. The difference is what triggers mitigation.

Hylex air handlerHH unit
R-454B detectorBuilt in
MitigationBuilt in
To addNothing
Add-on, on your furnaceHC coil
R-454B detectorBuilt into the coil
MitigationHA00A00203H1
To addThe controller, sold separately
HC coils compatible with the HA00A00203H1
  • HC24MCB021H1
  • HC36MBB021H1
  • HC36MCC021H1
  • HC48MBC021H1
  • HC60MCD021H1
  • HC60MBC021H1
  • HC60MAD021H1
The UL rule, in 15 secondsFrom 25% of the lower flammability limit
0 s · leak detected15 s · mitigation called for (general UL rule)
Heavierthan air

A2L refrigerants are heavier than air: the sensor sits where they would collect, per UL.

4Safety factor

Charge limits aim for dilution well below the flammability limit, with a factor of 4, per UL.

Alwayspowered

The HH unit label: leak detection installed, the unit must stay powered except for service.

Source: Samsung Hylex submittals with coil (05052026) and with HH unit (04072026); manual 679608-01; Samsung coil and HA00A00203H1 pages; UL Solutions (2024) and UL page on the 60335-2-40 standard.

10 · Leak alarm

A leak is detected. Who in the house finds out?

The sensor doesn’t beep: its signal goes to other parts of the system. Pick your setup, then run the drill and follow the signal, part by part.

System
Wall control
MIM-B14U module

The sensor is replaced after 10 years, per Samsung: safety standards don’t allow calibrating it in the field.

The HA00A00203H1 is not a detector: the R-454B detector is in the coil, and the controller is what shuts the system down and runs mitigation, per Samsung.

Source: Hylex coil (05052026) and AC036FCUPCG outdoor unit (02112026, p. 2) submittals; Hylex outdoor unit manual DB68-13654A, p. 9; Samsung HVAC FAQ (sensor, alarm, ASHRAE 15, MIM-B14U, ACU); Hylex HH unit submittal (04072026).

11 · External contacts

A window opens, the wall unit stops.

On a wall unit, an FJM head or a CAC unit, the MIM-B14U module follows a simple dry contact. On a Hylex, Samsung uses it for something else: night quiet mode and run and error outputs. Open the window to see.

Try it
On or off by dry contact
Hotel key card, door or window switch, occupancy sensor: these are Samsung’s examples, not separate modes.
On a Hylex
Samsung lists it for the outdoor unit’s night quiet mode, and for run and error outputs.
Run and error outputs
220 VAC, 3 A relays: one follows operation, the other, normally closed, opens on error.
External leak alarm
If you want an alarm, the MIM-B14U gives it a dry contact when the indoor unit detects a leak, per Samsung.

5 V, 5 mA input; 3 1/8 × 2 in enclosure, with bracket, for indoor use. On a wall unit, Samsung requires the MIM-A00UN board.

Source: Samsung MIM-B14 / MIM-B14U sheet (SHA-DVMS-07212023) and manual DB68-12292A, re-read Oct. 26, 2026; WindFree (10072024A) and Hylex (05052026) submittals; Samsung HVAC FAQ (external alarm).

12 · AirGreen × SAMSUNG

Samsung makes the parts. AirGreen sets them up on your Hylex.

A Hylex has more parts than you’d think. Samsung numbers them; we plan them, install them and set up the ACU.

SAMSUNG

What SAMSUNG brings

  • The MXD-U001XN ACU3 W max, four magnets, Wi-Fi and nine thermostat terminals.
  • Coil mitigationThe HA00A00203H1, for all seven HC coils in the line.
  • Five heat kits5 to 20 kW for the HH unit, with the HA15B0CH1 kit offered for 15 and 20 kW.
  • Contacts when neededMIM-B14U for night quiet mode and run and error outputs; URK-3A for a PSC motor.
AirGreen

What AirGreen brings

  • Sold and installed by AirGreenThe visit, the quote, the install and start-up.
  • The ACU set at start-upBackup stages, fan, condensate pump, leak alarm: we set its switches for your equipment.
  • The thermostat picked with youA two-stage 24 V model, as Samsung recommends, or the MWR-WG01UN for app control.
  • All in the quoteRequired parts are there from the start, with their Samsung numbers.
  • RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16.
13 · True or false

Hylex parts, in six claims.

True or false? Each card flips to its source.

0/ 6

Pick True or False: the card flips to show the answer and its source.

01

The ACU is required, even with Samsung’s own indoor unit.

02

The HA15B0CH1 kit is required with a 15 kW heat kit.

03

The HC coil has no leak detector.

04

The URK-3A relay kit works with a gas furnace.

05

The ACU can shut the Hylex down if condensate water rises.

06

Samsung gives two ratings for the same HA07E0CH1 kit.

14 · Frequently asked questions

What people ask about Samsung parts.

Yes. Samsung requires it on every Hylex system, even with a Samsung indoor unit. It is sold separately.

R-454B is an A2L refrigerant. With an HC coil, Samsung requires the HA00A00203H1; the HH unit has its own built-in detector and mitigation.

No: the ACU supports 2.4 GHz Wi-Fi only, per its manual. We check your network at install.

The ACU and its Wi-Fi module, with the module holder, 2 cable ties, 5 M4 × 16 screws, 5 holder locks, 24 U-rings, the fan speed control wire, a Wi-Fi extension wire, the float switch wire, the manual and a wire label, per Samsung. The float switch itself is bought separately.

The MXD-U001XN ACU is still required, and Samsung calls for a field-supplied R-454B detector, installed where the maker specifies, that sends a 24 VAC alarm to the ACU.

No, they are optional. For 15 or 20 kW, Samsung offers the HA15B0CH1 single-point breaker kit, which feeds the heat kit from one point. We discuss them during the visit, based on the house and your current heating.

Yes: 1 or 2 stages, per Samsung, which recommends a 2-stage thermostat.

Yes. For downflow, Samsung calls for a kit: HA00DA0H1, HA00DB0H1 or HA00DC0H1 depending on the model. On 24,000 BTU/h units, no 10 kW kit in that position.

Only if your indoor unit has a PSC motor and no two cooling inputs, per Samsung. It is not compatible with gas furnaces, and Samsung’s HH unit doesn’t need it.

Yes: per Samsung, it must be replaced after 10 years, and safety standards don’t allow calibrating it in the field.

No question matches. Call us: 514 316-2973.

15 · The Samsung range

These parts go on a Hylex. Here are the units.

The full SAMSUNG page

Sources checked on October 26, 2026

  1. Samsung HVAC Hylex R-454B spec sheets (2026), Hylex brochure (HYLEXBR 02.2026-V2) and MXD-U001XN control unit installation manual.
  2. Samsung HVAC Individual Wired Controls (MWR-SH12UN, MWR-WG01UN) and MIM-H04UN pages, and their submittals.
  3. airgreen.ca product pages, Oct. 8, 2026.
  4. Samsung Hylex R-454B submittals with HH unit (04072026) and with coil (05052026); HH unit manual 679608-01 (March 2026); MXD-U001XN ACU manual (DB68-13653A-00); MIM-B14 / MIM-B14U sheet (SHA-DVMS-07212023).
  5. UL Solutions, “Inspecting Refrigerant Detection Systems in HVAC Equipment” (Oct 21, 2024) and “Updated Requirements for Refrigerant Detection Systems” (UL 60335-2-40).
  6. Samsung MXD-U001XN ACU manual (DB68-13653A-00), p. 6, 11, 14, 17, 22 to 27 and 36, re-read Oct. 26, 2026; Hylex Premium AC036FCUPCG outdoor unit sheet (02112026), p. 2, 4 and 5, re-read Oct. 26, 2026.
  7. Samsung MIM-B14 / MIM-B14U sheet (SHA-DVMS-07212023) and manual DB68-12292A, re-read Oct. 26, 2026; Hylex R-454B outdoor unit manual (DB68-13654A), p. 9; Samsung HVAC FAQ, re-read Oct. 26, 2026.

Prices on quote.

The SAMSUNG shop

Samsung parts, right below.

Each product page gives the part number and its use.

AirGreenSAMSUNG
Prices on quote. Free home estimate.