AirGreen × SAMSUNGFJM Premium: heats down to -25 °C100% performance down to -15 °C, per SamsungENERGY STAR cold climate62 pairs in Samsung’s tables2 WindFree heads12-12-6 warranty: 12 years compressor, 12 years parts, 6 years labourMontreal · Laval · Longueuil · South Shore · North Shore
01 · Which outdoor unit?

Two heads: four possible outdoor units, from the 20,000 to the 36,000.

Pick an outdoor unit: its model, its ports, the heads it takes with 2 heads, its certified capacity at -8 °C and the LogisVert amount of the all-wall-head listing, with the math.

1Which outdoor unit?
2Your 2 rooms
2-head combinations in Samsung’s tables
20,0009
24,00013
30,00019
36,00021

62 pairs in all

The outdoor unit size follows the rooms: we size each one during the visit.

Source: Samsung FJM Premium submittals (02142025A); Hydro-Québec’s LogisVert list, all-wall-head listings, read Oct. 26, 2026 (“Puissance à -8 °C”); SEER2 and HSPF2: Samsung’s “Non-ducted” column and the ENERGY STAR record for each AHRI number.

02 · Build your system

Two heads: is your pair in Samsung’s table?

Pick each room’s head. The tool looks the pair up in all four outdoor units’ tables and says why a unit refuses it: with two heads, one head’s size can be enough.

One head per room: pick each size
Room 1
Room 2

Sizes come from the load calculation for each room, done at the visit. Here you see what Samsung’s combination table accepts, unit by unit.

Source: combination tables in Samsung FJM Premium submittals (02142025A); amounts: Hydro-Québec’s LogisVert list, all-wall-head listings, read Oct. 26, 2026; Max Heat: same list, Oct. 14, 2026.

03 · Two big rooms

24,000 + 24,000: a pair that only exists with two heads.

The bigger the outdoor unit, the bigger the pair of heads it can take. On the 36,000, Samsung accepts two 24,000 heads. With three or four heads, that pair isn’t in any table. Pick a unit: the heads draw at their real width.

12,000AJ012DNADCG15,000AJ015DNADCGOn the wall: 32 5/16 + 41 9/16 = 73 7/8 inConnected heads: 27,000 BTU/h2-head maximum: 27,0000
SAMSUNGAJ012DNADCGCooling / heating: 12,000 / 12,000 BTU/h32 5/16 × 11 3/4 × 8 7/16 in · 19.6 lbSound, high / Silent: 38 / 23 dB(A)Gas 3/8 in
SAMSUNGAJ015DNADCGCooling / heating: 15,000 / 15,000 BTU/h41 9/16 × 11 3/4 × 8 7/16 in · 25.4 lbSound, high / Silent: 41 / 30 dB(A)Gas 1/2 in

Pairs not in this unit’s table15,000 + 15,000 · any pair with an 18,000 or a 24,000

Two pairs at this unit’s maximum:

15,000AJ015DNADCG15,000AJ015DNADCGOn the wall: 41 9/16 + 41 9/16 = 83 1/8 inConnected heads: 30,000 BTU/h2-head maximum: 30,0000
SAMSUNGAJ015DNADCGCooling / heating: 15,000 / 15,000 BTU/h41 9/16 × 11 3/4 × 8 7/16 in · 25.4 lbSound, high / Silent: 41 / 30 dB(A)Gas 1/2 in

Pairs not in this unit’s table15,000 + 18,000 · 18,000 + 18,000 · any pair with a 24,000

12,000AJ012DNADCG18,000AJ018DNADCGOn the wall: 32 5/16 + 41 9/16 = 73 7/8 inConnected heads: 30,000 BTU/h2-head maximum: 30,0000
SAMSUNGAJ012DNADCGCooling / heating: 12,000 / 12,000 BTU/h32 5/16 × 11 3/4 × 8 7/16 in · 19.6 lbSound, high / Silent: 38 / 23 dB(A)Gas 3/8 in
SAMSUNGAJ018DNADCGCooling / heating: 18,000 / 21,000 BTU/h41 9/16 × 11 3/4 × 8 7/16 in · 25.4 lbSound, high / Silent: 41 / 30 dB(A)Gas 1/2 in

Pairs not in this unit’s table15,000 + 18,000 · 18,000 + 18,000 · any pair with a 24,000

Two pairs at this unit’s maximum:

15,000AJ015DNADCG24,000AJ024DNADCGOn the wall: 41 9/16 + 41 9/16 = 83 1/8 inConnected heads: 39,000 BTU/h2-head maximum: 39,0000
SAMSUNGAJ015DNADCGCooling / heating: 15,000 / 15,000 BTU/h41 9/16 × 11 3/4 × 8 7/16 in · 25.4 lbSound, high / Silent: 41 / 30 dB(A)Gas 1/2 in
SAMSUNGAJ024DNADCGCooling / heating: 22,000 / 24,000 BTU/h41 9/16 × 11 3/4 × 8 7/16 in · 25.4 lbSound, high / Silent: 45 / 30 dB(A)Gas 5/8 in

Pairs not in this unit’s table18,000 + 24,000 · 24,000 + 24,000

18,000AJ018DNADCG18,000AJ018DNADCGOn the wall: 41 9/16 + 41 9/16 = 83 1/8 inConnected heads: 36,000 BTU/h2-head maximum: 39,0000
SAMSUNGAJ018DNADCGCooling / heating: 18,000 / 21,000 BTU/h41 9/16 × 11 3/4 × 8 7/16 in · 25.4 lbSound, high / Silent: 41 / 30 dB(A)Gas 1/2 in

Pairs not in this unit’s table18,000 + 24,000 · 24,000 + 24,000

24,000AJ024DNADCG24,000AJ024DNADCGOn the wall: 41 9/16 + 41 9/16 = 83 1/8 inConnected heads: 48,000 BTU/h2-head maximum: 48,0000
SAMSUNGAJ024DNADCGCooling / heating: 22,000 / 24,000 BTU/h41 9/16 × 11 3/4 × 8 7/16 in · 25.4 lbSound, high / Silent: 45 / 30 dB(A)Gas 5/8 in

21 pairs out of 21The 36,000 lists every pair its six head sizes allow.

Width follows capacity: up to 12,000 BTU/h a head is 32 5/16 in wide; from 15,000 to 24,000, 41 9/16 in. Two 24,000s take 83 1/8 in of wall. We measure your walls at the visit. Drawn to scale.

Source: combination tables in Samsung FJM Premium submittals (02142025A); heads: Samsung FJM technical data book, Ver. 1.2 (dimensions, weight, “H / Silent” sound, gas line). Width sums: our math.

04 · Quick game

What’s the smallest outdoor unit for this pair?

Six pairs, four answers. Hint: each unit has two limits, the heads’ total and the biggest head. With two heads, a single head’s size can block on its own.

Round 1 / 6Score 0

The smallest unit that takes this pair?

20,000max head 15,000
24,000max head 18,000
30,000max head 24,000
36,000max head 24,000

heads totalunit’s ceiling

The two limits, heads total (27,000, 32,000, 40,000 or 48,000) and biggest head (15,000, 18,000, 24,000 or 24,000), are our reading of Samsung’s tables: they reproduce all 200 rows, with no exception. Samsung doesn’t state them that way.

Source: combination tables in Samsung AJ020DXS3CG and AJ024/030/036DXS4CG submittals (02142025A).

05 · The heads

Up to 24,000 on the wall, 18,000 overhead: two heads, two styles.

Samsung shows four FJM head families. With two heads every size is in play: wall heads up to 24,000 BTU/h, slim ducts, mini cassettes and consoles up to 18,000. Our dual-zones in the store come with wall heads; restrictions apply to the other families, so we confirm the pair in the quote.

Source: Samsung FJM Premium submittals (02142025A), compatibility matrix (“** Restrictions apply”); Samsung model lists by family; slim duct manual DB68-12926A (one room only).

06 · The layout

One line per room: two of them, 82 ft each at most.

Each head has its own line to the outdoor unit. Switch between two wall heads and a mix of families, then follow the steps.

Room 121°Room 219°Up to 82 ft (25 m) per head2 × 82 ft = 164 ft max (our math)49 ft (15 m) of height25 ft (7.5 m) between the two heads

Illustration. Limits: Samsung FJM Premium submittals (02142025A) and installation manual DB68-13175A. “Mixed”: wall, slim duct, mini cassette and console are listed by Samsung; restrictions apply, we check every combination.

07 · Where the outdoor unit goes

194 lb: on the ground or a flat roof, never hung on a wall.

Four of the nine FJM dual-zones shown further down sit on a roof. A wall is out: Samsung says any outdoor unit over 132.2 lb (60 kg) must stand on the floor, and the FJM Premium weighs 191.8 to 194 lb.

Expected snow123
  1. SAMSUNGA frame higher than the expected snowfall, and a snow-proof hood.
  2. SAMSUNGNo drain hose, plug or cap on these models: defrost water drains naturally.
  3. SAMSUNGA base pan heater as standard, for defrost water (150 W per NEEP).
1234
  1. SAMSUNGOn a roof: waterproof the unit and check the roof’s strength.
  2. AIRGREENOur Brossard install: a raised metal stand, long wooden beams and a protective membrane.
  3. AIRGREENAnd two diagonal metal braces.
  4. SAMSUNGStrong winds: shield plates around the unit, so the fan runs correctly.
Samsung limit: 132.2 lb (60 kg)FJM: 191.8 to 194 lb0 lb200 lb
On a wall: no.

Samsung: above a net weight of 132.2 lb (60 kg), the outdoor unit isn’t hung on a wall, it stands on the floor. The FJM Premium weighs 191.8 lb (20,000) or 194 lb (24,000 to 36,000).

4 / 9

of the FJM dual-zones shown further down are on a roof:

Source: Samsung installation manual DB68-13175A (132.2 lb, snow frame and hood, shield plates, roof, no drain hose); submittals 02142025A (weight, base pan heater as standard); NEEP, base pan heater power; AirGreen “Nos réalisations”, Brossard (Aug. 10, 2026). Illustrations.

08 · One more room, someday

Two heads today. A third one later?

Our 2-head outdoor units have 3 or 4 ports. Pick the unit and your two heads: we show which third, then fourth head Samsung’s tables would accept on the same unit.

1The outdoor unit
2Your two heads today (listed pairs)

Adding a head means a new line and a new start-up: Samsung’s procedure includes a pipe check and head addressing. We confirm the final combination in the quote. On the 20,000, five of nine pairs leave no room for a third head: 7+15, 9+12, 9+15, 12+12 and 12+15.

Source: Samsung FJM Premium submittals (02142025A), “3 Port” and “4 Port Condensing Unit” titles and 2-, 3- and 4-head tables; installation manual DB68-13175A (“Pipe Checking Operation”, head addressing).

09 · 2 · 3 · 4 heads

Two heads to start. One more room? See 3 or 4 heads.

Source: combination tables in Samsung FJM Premium submittals (02142025A): 62 pairs, 83 trios, 55 sets of four; samsunghvac.com, “up to four zones with one outdoor unit”.

10 · Multi-zone or wall units?

Two rooms: one FJM 24,000, or two Max Heat 12,000 wall units?

Both heat and cool. What changes: the number of outdoor units, the LogisVert amount, the lowest heating temperature and the distances allowed. Switch to count the boxes outside.

Room 1Room 21 outdoor unitRoom 1Room 22 outdoor units
12outdoor unitoutdoor units
FJM 24,000 (12,000 + 12,000)2 × Max Heat 12,000
Outdoor units1 · 194.0 lb · 37 × 47 5/8 × 13 in2 · 71.0 lb each (142.0 lb) · 2 × 31 1/8 in = 62 1/4 in side by side
LogisVert$1,824 (AHRI 216372794, all wall heads)$1,272 worked out per wall unit. Several systems in one home? Only Hydro-Québec confirms the assistance granted.
Heats down to-25 °C; 100% down to -15 °C, per Samsung-30 °C; 100% down to -20 °C, per Samsung
Lines82 ft per head, 230 ft in total66 ft per unit
Max breaker40 A20 A per unit
R-32 in the house109.3 oz, nothing to add2 × 34.0 oz = 68.0 oz for 24.6 ft each, more beyond

With two rooms, the two wall units heat to a lower temperature and weigh less together. The FJM puts just one unit outside. We compare both at the visit.

Source: Samsung FJM Premium (02142025A) and WindFree Max Heat (10072024A) submittals; Hydro-Québec’s LogisVert list (FJM: Oct. 26, 2026; Max Heat: Oct. 14, 2026). Widths and sums: our math.

11 · Hydro-Québec LogisVert

All wall heads, mixed or ducted: the amount follows the listing.

Each FJM Premium outdoor unit has three AHRI listings, depending on the heads installed. Hydro-Québec pays on the installed listing’s certified capacity at -8 °C, at $120 per 1,000 BTU/h: one amount for the system, however many heads. Pick a unit, then your heads.

The outdoor unit
The heads installed
All wall heads$1,584
Mixed$1,584
All ducted heads$1,584
All wall heads$1,824
Mixed$1,812
All ducted heads$1,800
All wall heads$2,100
Mixed$2,076
All ducted heads$2,064
All wall heads$2,760
Mixed$2,616
All ducted heads$2,472

The 20,000 pays $1,584 in all three cases. On the others, a slim duct, cassette or console head changes the AHRI number, and the amount.

Source: Hydro-Québec, list of heat pumps eligible for LogisVert (owner, existing home), FJM rows re-read Oct. 26, 2026; classes “Multizone All Non-Ducted”, “Mix Ducted/Non-Ducted” and “All Ducted”: NEEP, by AHRI number; IDs and COP: ENERGY STAR. Our dual-zones in the store come with wall heads: that is this page’s default listing. Hydro-Québec’s list prevails; the final amount is confirmed when you apply. The program rules are explained once, on the Samsung page.

12 · The spec sheet, made clear

The 2-head spec sheet: the outdoor unit, heads up to 24,000.

Pick an outdoor unit: size, weight, sound and the range of connected heads with two heads. Heads from 15,000 to 24,000 are wider: 41 9/16 in instead of 32 5/16.

SAMSUNGFJM Premium multi-zone
OutdoorAJ020DXS3CG
AHRI, all wall heads216372795
Ports3 · 2 to 3 heads
RefrigerantR-32 · 109.3 oz factory charge
Power208-230 V · 60 Hz · MCA 35.9 A
SEER223.0 all wall heads (Samsung: non-ducted)
HSPF210.5 all wall heads
Samsung submittal 02142025AAIRGREEN SUMMARY

Wall head 7,000 to 12,000 · 19.6 lb

32 5/16 in11 3/4 in8 7/16 in

Wall head 15,000 to 24,000 · 25.4 lb

41 9/16 in11 3/4 in8 7/16 in

Outdoor unit · 191.8 lb

37 in47 5/8 in13 in

Sound in dB(A), with references

Silent 23Silent 30High 45Outdoor 5120
Rustling leaves
30
Whisper
40
Quiet library
50
Moderate rain
60
Conversation

Heads in Silent mode: 23 dB(A) from 7,000 to 12,000, 30 dB(A) from 15,000 to 24,000; the 24,000 on high: 45 dB(A); outdoor unit in heating: 51 dB(A), per Samsung. References: American Academy of Audiology, for a sense of scale.

21,000 BTU/hrated cooling (non-ducted)
22,000 BTU/h22,000 BTU/h rated; 22,000 at -15 °C per ENERGY STAR (AHRI 216372795)
14,000 to 27,000BTU/h of connected heads with two heads, per Samsung’s table
-25 °Cheating limit; 100% down to -15 °C, per Samsung
-10 °Ccools from -10 to 46 °C
$1,584LogisVert, all-wall-head listing
SAMSUNGFJM Premium multi-zone
OutdoorAJ024DXS4CG
AHRI, all wall heads216372794
Ports4 · 2 to 4 heads
RefrigerantR-32 · 109.3 oz factory charge
Power208-230 V · 60 Hz · MCA 35.9 A
SEER223.0 all wall heads (Samsung: non-ducted)
HSPF210.4 all wall heads
Samsung submittal 02142025AAIRGREEN SUMMARY

Wall head 7,000 to 12,000 · 19.6 lb

32 5/16 in11 3/4 in8 7/16 in

Wall head 15,000 to 24,000 · 25.4 lb

41 9/16 in11 3/4 in8 7/16 in

Outdoor unit · 194.0 lb

37 in47 5/8 in13 in

Sound in dB(A), with references

Silent 23Silent 30High 45Outdoor 5220
Rustling leaves
30
Whisper
40
Quiet library
50
Moderate rain
60
Conversation

Heads in Silent mode: 23 dB(A) from 7,000 to 12,000, 30 dB(A) from 15,000 to 24,000; the 24,000 on high: 45 dB(A); outdoor unit in heating: 52 dB(A), per Samsung. References: American Academy of Audiology, for a sense of scale.

25,000 BTU/hrated cooling (non-ducted)
25,000 BTU/h25,000 BTU/h rated; 25,000 at -15 °C per ENERGY STAR (AHRI 216372794)
14,000 to 30,000BTU/h of connected heads with two heads, per Samsung’s table
-25 °Cheating limit; 100% down to -15 °C, per Samsung
-10 °Ccools from -10 to 46 °C
$1,824LogisVert, all-wall-head listing
SAMSUNGFJM Premium multi-zone
OutdoorAJ030DXS4CG
AHRI, all wall heads216372793
Ports4 · 2 to 4 heads
RefrigerantR-32 · 109.3 oz factory charge
Power208-230 V · 60 Hz · MCA 35.9 A
SEER222.5 all wall heads (Samsung: non-ducted)
HSPF210.0 all wall heads
Samsung submittal 02142025AAIRGREEN SUMMARY

Wall head 7,000 to 12,000 · 19.6 lb

32 5/16 in11 3/4 in8 7/16 in

Wall head 15,000 to 24,000 · 25.4 lb

41 9/16 in11 3/4 in8 7/16 in

Outdoor unit · 194.0 lb

37 in47 5/8 in13 in

Sound in dB(A), with references

Silent 23Silent 30High 45Outdoor 5320
Rustling leaves
30
Whisper
40
Quiet library
50
Moderate rain
60
Conversation

Heads in Silent mode: 23 dB(A) from 7,000 to 12,000, 30 dB(A) from 15,000 to 24,000; the 24,000 on high: 45 dB(A); outdoor unit in heating: 53 dB(A), per Samsung. References: American Academy of Audiology, for a sense of scale.

28,400 BTU/hrated cooling (non-ducted)
28,600 BTU/h28,600 BTU/h rated; 28,600 at -15 °C per ENERGY STAR (AHRI 216372793)
14,000 to 39,000BTU/h of connected heads with two heads, per Samsung’s table
-25 °Cheating limit; 100% down to -15 °C, per Samsung
-10 °Ccools from -10 to 46 °C
$2,100LogisVert, all-wall-head listing
SAMSUNGFJM Premium multi-zone
OutdoorAJ036DXS4CG
AHRI, all wall heads216372792
Ports4 · 2 to 4 heads
RefrigerantR-32 · 109.3 oz factory charge
Power208-230 V · 60 Hz · MCA 35.9 A
SEER221.5 all wall heads (Samsung: non-ducted)
HSPF29.5 all wall heads
Samsung submittal 02142025AAIRGREEN SUMMARY

Wall head 7,000 to 12,000 · 19.6 lb

32 5/16 in11 3/4 in8 7/16 in

Wall head 15,000 to 24,000 · 25.4 lb

41 9/16 in11 3/4 in8 7/16 in

Outdoor unit · 194.0 lb

37 in47 5/8 in13 in

Sound in dB(A), with references

Silent 23Silent 30High 45Outdoor 5320
Rustling leaves
30
Whisper
40
Quiet library
50
Moderate rain
60
Conversation

Heads in Silent mode: 23 dB(A) from 7,000 to 12,000, 30 dB(A) from 15,000 to 24,000; the 24,000 on high: 45 dB(A); outdoor unit in heating: 53 dB(A), per Samsung. References: American Academy of Audiology, for a sense of scale.

34,000 BTU/hrated cooling (non-ducted)
36,600 BTU/h36,600 BTU/h rated; 36,600 at -15 °C per ENERGY STAR (AHRI 216372792)
14,000 to 48,000BTU/h of connected heads with two heads, per Samsung’s table
-25 °Cheating limit; 100% down to -15 °C, per Samsung
-10 °Ccools from -10 to 46 °C
$2,760LogisVert, all-wall-head listing

Sources: Samsung FJM Premium submittals (02142025A); heads: Samsung FJM technical data book, Ver. 1.2, same AJ0xxDNADCG models (sound “H / Silent”: high speed and Silent mode). Outdoor: heating value, high speed; Samsung does not publish the measuring distance.

13 · Samsung plate

The 2-head plate, unit by unit.

The four outdoor units that take two heads, side by side, with Samsung’s own term under each row and each unit’s three AHRI listings. Where Samsung publishes nothing, the cell says so.

FJM Premium · 2 heads
Outdoor unit20,00024,00030,00036,000
Identification
Outdoor unitModel (US code)AJ020DXS3CG/AA (JXG20S3D)AJ024DXS4CG/AA (JXG24S4D)AJ030DXS4CG/AA (JXG30S4D)AJ036DXS4CG/AA (JXG36S4D)
Ports3 / 4 Port Condensing Unit3444
Capacity indexCapacity Index21243036
AHRI number, all wall headsMultizone All Non-Ducted216372795216372794216372793216372792
AHRI number, mixedMix Ducted/Non-Ducted216411178216411177216411304216411176
AHRI number, all ductedMultizone All Ducted216372803216372802216372801216372800
ENERGY STAR ID, all wall headsENERGY STAR Unique ID3891562389156138915603891558
LogisVert, Hydro-Québec listOct. 26, 2026, all wall heads$1,584$1,824$2,100$2,760
LogisVert, mixed / all ductedOct. 26, 2026$1,584 / $1,584$1,812 / $1,800$2,076 / $2,064$2,616 / $2,472
With 2 heads
Combinations in the table2-unit rows9 pairs13 pairs19 pairs21 pairs
Connected heads, lightest to heaviestBTU/h14,000 to 27,00014,000 to 30,00014,000 to 39,00014,000 to 48,000
Share of the index (our math)67 to 129 %58 to 125 %47 to 130 %39 to 133 %
Largest head allowedBTU/h15,00018,00024,00024,000
Free ports1 of 32 of 42 of 42 of 4
Heating, all wall heads
Rated capacity, cooling / heatingRated capacity, non-ducted (BTU/h)21,000 / 22,00025,000 / 25,00028,400 / 28,60034,000 / 36,600
Heat at 8.3 / -8.3 / -15 °CENERGY STAR, 47 / 17 / 5 °F22,000 / 13,200 / 22,00025,000 / 15,200 / 25,00028,600 / 17,500 / 28,60036,600 / 23,000 / 36,600
COP at 8.3 / -8.3 °CNEEP, 47 / 17 °F4.64 / 2.954.70 / 2.893.99 / 2.834.21 / 2.45
COP at -15 °CENERGY STAR, 5 °F1.951.851.812.04
Coldest point listed on NEEP, -25 °CNEEP, -13 °Fup to 18,000 BTU/h · COP 1.61up to 18,000 BTU/h · COP 1.61up to 20,000 BTU/h · COP 1.87up to 20,000 BTU/h · COP 1.87
Min / max capacity at 8.3 °CNEEP, 47 °F7,600 / 32,0007,600 / 42,0007,600 / 54,5007,600 / 54,500
Efficiency
SEER2 / EER2Non-ducted23.00 / 15.0023.00 / 14.5522.50 / 13.5021.50 / 12.50
HSPF2, region IV / region VSamsung · NEEP10.5 / 7.110.4 / 7.110.0 / 6.99.5 / 7.7
Sound
Outdoor, cooling / heating, highSound Pressure Level, dB(A)50 / 5151 / 5252 / 5352 / 53
Distance and test conditionsnot publishednot publishednot publishednot published
Installation
Power · MCA / max breaker1 / 208-230 / 6035.9 A / 40.0 A35.9 A / 40.0 A35.9 A / 40.0 A35.9 A / 40.0 A
Liquid / gas connectionsHigh side / Low side (suction), in1/4 × 3 / 3/8 × 31/4 × 4 / 3/8 × 2 + 1/2 × 21/4 × 4 / 3/8 × 2 + 1/2 × 21/4 × 4 / 3/8 × 2 + 1/2 × 2
Adapters includedIncluded Pipe Adapters, in1 × 3/8 × 1/22 × 1/2 × 3/82 × 1/2 × 3/82 × 1/2 × 3/8 + 2 × 1/2 × 5/8
R-32 factory chargeFactory Charge · Charged for109.3 oz (3,100 g) · 230 ft109.3 oz (3,100 g) · 230 ft109.3 oz (3,100 g) · 230 ft109.3 oz (3,100 g) · 230 ft
Lines: per head / total / minimumft82 / 230 / 10 ft82 / 230 / 10 ft82 / 230 / 10 ft82 / 230 / 10 ft
Rise: to the outdoor unit / between headsft49 / 25 ft49 / 25 ft49 / 25 ft49 / 25 ft
Outdoor W × H × D · weightin · lb37 × 47 5/8 × 13 in · 191.8 lb37 × 47 5/8 × 13 in · 194.0 lb37 × 47 5/8 × 13 in · 194.0 lb37 × 47 5/8 × 13 in · 194.0 lb
Base pan heaterSamsung: “as standard” · NEEPstandard · 150 W per NEEPstandard · 150 W per NEEPstandard · 150 W per NEEPstandard · 150 W per NEEP
What Samsung does not publish
  • The distance and conditions behind the sound figures, indoors and out.
  • The base pan heater’s power: Samsung writes “as standard”, NEEP lists 150 W.
  • How to read its model numbers: Samsung writes them with wildcards (AJ0**DXS*CG).
  • The submittals and manual don’t say which head goes on the 3/8 in or the 1/2 in port: we decide it at install, with the adapters supplied.

Sources: Samsung FJM Premium submittals (02142025A; 24,000 and 36,000 adapters re-read Oct. 26, 2026) and combination tables; manual DB68-13175A; ENERGY STAR (w7cv-9xjt) and NEEP, read by AHRI number on Oct. 14, 2026; Hydro-Québec’s LogisVert list, FJM rows re-read Oct. 26, 2026. Listing classes come from NEEP. Index percentages are our math. ENERGY STAR lists less heat at -8.3 °C than at -15 °C for these units: we show its values as published, and Hydro-Québec works out its amount from the -8.3 °C one.

14 · AirGreen × SAMSUNG

Two Samsung heads, one AirGreen crew to install them.

Samsung makes the unit and its tables. AirGreen picks the pair with you, finds where the outdoor unit goes and does the start-up.

SAMSUNG

What SAMSUNG brings

  • 24,000 + 24,000The biggest pair, on the 36,000, per Samsung’s table.
  • 62 pairs listed9 on the 20,000, 13 on the 24,000, 19 on the 30,000, 21 on the 36,000.
  • Down to -25 °CAnd 100% of heating performance down to -15 °C, per Samsung.
  • Leak detection in every headIf there’s a leak, the system stops the compressor and runs the head’s fan, per Samsung.
AirGreen

What AirGreen brings

  • Sold and installed by AirGreenThe visit, the quote, the install and the start-up.
  • Two line runs checked at the visitOne line per head, 82 ft max each.
  • On the ground or a flat roofFour of the nine dual-zones shown on this page are on a roof.
  • RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16.
15 · Our FJM installs

Nine FJM dual-zones, four of them on a roof.

Dual-zones installed from Brossard to Sainte-Thérèse, each one written up on our blog, from the outdoor unit to the two heads.

All our installs
16 · True or false

The dual-zone, in six claims.

True or false? Flip the cards: the answers come from Samsung’s submittals and manuals, and Hydro-Québec’s list.

0/ 6

Pick True or False: the card flips to show the answer and its source.

01

You can connect a single head to an FJM, to start with.

02

Each head needs at least 10 ft of line.

03

The FJM Premium keeps 100% of its heating capacity at -15 °C, per Samsung.

04

With two heads you can run up to 230 ft of line.

05

The “24,000” head cools at 24,000 BTU/h.

06

Wall heads or ducted heads, an FJM’s LogisVert amount stays the same.

17 · Frequently asked questions

What people ask about Samsung dual-zones.

Two at least: Samsung prohibits connecting a single indoor unit. Three at most on the 20,000 (AJ020DXS3CG, three ports) and four on the 24,000, 30,000 and 36,000. With two heads, all four units work: Samsung lists 62 pairs on them.

Yes, only on the 36,000: 18,000 + 24,000 = 42,000 BTU/h of heads. On the 30,000, that pair isn’t in the table.

82 ft (25 m) per head at most, so 164 ft for two (our math). Samsung’s 230 ft (70 m) total doesn’t come into play. And the factory charge covers it: Samsung says not to add refrigerant.

Often, yes: the 20,000 has three ports, the others four. The final combination has to be in Samsung’s table, for example 9,000 + 9,000 + 9,000 on the 20,000. It means a new line and a new start-up, so we confirm it in the quote.

Often, yes. Each outdoor unit has three AHRI listings: all wall heads, mixed, all ducted heads. On the 36,000, Hydro-Québec’s list of Oct. 26, 2026 gives $2,760 for all wall heads and $2,616 for a mix; the 20,000 stays at $1,584 in all three cases.

No. Over 132.2 lb (60 kg), Samsung says the outdoor unit stands on the floor rather than hanging on a wall, and the FJM Premium weighs 191.8 to 194 lb. We set it on the ground, on a stand, or on a flat roof once the roof is checked.

Two wall units mean two outdoor units. Each wall unit of 12,000 BTU/h or more has its own amount worked out, but the LogisVert guide doesn’t say whether two systems in one home each get theirs: we confirm it with Hydro-Québec. The multi-zone has one outdoor unit and one AHRI number. We compare both at the visit.

No. Samsung prohibits connecting a single indoor unit to these outdoor units: you need at least two. For one room, a single-zone wall unit is the right unit.

Yes. Each head has its own temperature setting: a bedroom can stay cooler than the living room.

No question matches. Call us: 514 316-2973.

18 · The Samsung range

Just one room, or a house with ducts?

For one room, the Samsung wall unit; for a house with ducts, the Hylex central system. The rest of the Samsung range we sell and install.

The full SAMSUNG page
AirGreen × SAMSUNGSold and installed by AirGreen62 pairs in Samsung’s tablesUp to 4 heads per outdoor unitFree home estimate

Sources checked on October 14 and 26, 2026

  1. Samsung FJM Premium submittals AJ020DXS3CG and AJ024/030/036DXS4CG, version 02142025A (files of Jan. 14, 2026), combination tables included; read Oct. 14, 2026, AJ024 and AJ036 re-read Oct. 26, 2026.
  2. Samsung installation manuals DB68-13175A-00 (FJM R-32 outdoor unit) and DB68-13426A-01 (AJ0**DNADCG wall heads); technical data book “Free Joint Multi … (R32, 60Hz, HP)”, Ver. 1.2 (head data).
  3. samsunghvac.com, “Free Joint Multi Premium” page, read Oct. 14, 2026.
  4. ENERGY STAR, Certified Air-Source Heat Pumps (dataset w7cv-9xjt), records read by AHRI number on Oct. 14, 2026.
  5. NEEP, Cold Climate Air Source Heat Pump List, records read by AHRI number on Oct. 14, 2026 (listing classes, COP, coldest point, base pan heater).
  6. Hydro-Québec, list of heat pumps eligible for LogisVert (owner, existing home): file of Oct. 14, 2026, FJM rows re-read Oct. 26, 2026; Participation guide v1.10 (Sept. 15, 2026).
  7. Samsung WindFree Max Heat submittals (10072024A) and AR**DX*** wall-unit installation manual, for the comparisons with separate wall units.
  8. AirGreen, “Nos réalisations” blog: the nine FJM Premium dual-zones shown on this page.
  9. American Academy of Audiology, “Levels of Noise in Decibels”, 2023 (sound references).

LogisVert amounts are indicative: Hydro-Québec confirms them when you apply. Prices on quote.

The SAMSUNG shop

Our 2-head Samsung multi-zones, right below.

Each listing gives the outdoor unit, the AHRI number and the certified ratings. The head sizes allowed are those in Samsung’s table, above.

AirGreenSAMSUNG
Prices on quote. Free home estimate.