Three rooms, one outdoor unit.
Three line runs sharing 230 ft, and 83 three-head combinations in Samsung’s tables, across four outdoor units. The Samsung FJM Premium heats down to -25 °C and keeps 100% of its heating performance down to -15 °C, per Samsung. LogisVert, all wall heads: $1,584 to $2,760 for the system.
- 83 trios in Samsung’s tables
- 230 ft of line for three
- WindFree™ heads, 7,000 to 24,000
With three heads, the 20,000 uses all three of its ports; the 24,000, 30,000 and 36,000 keep one free.
Samsung FJM Premium submittals (02142025A).
Three heads: the 20,000 fills up, the other three keep a port free.
Pick an outdoor unit: its model, its ports, the heads it takes with 3 heads, its certified capacity at -8 °C and the LogisVert amount of the all-wall-head listing, with the math.
83 trios in all
The outdoor unit size follows the rooms: we size each one during the visit.
FJM Premium 20,000 · 3 heads
Hydro-Québec’s LogisVert list, all-wall-head listing (Oct. 26, 2026)
With a slim duct, cassette or console head, the AHRI listing changes, and so does the amount: we confirm it in the quote.
FJM Premium 24,000 · 3 heads
Hydro-Québec’s LogisVert list, all-wall-head listing (Oct. 26, 2026)
With a slim duct, cassette or console head, the AHRI listing changes, and so does the amount: we confirm it in the quote.
FJM Premium 30,000 · 3 heads
Hydro-Québec’s LogisVert list, all-wall-head listing (Oct. 26, 2026)
With a slim duct, cassette or console head, the AHRI listing changes, and so does the amount: we confirm it in the quote.
FJM Premium 36,000 · 3 heads
Hydro-Québec’s LogisVert list, all-wall-head listing (Oct. 26, 2026)
With a slim duct, cassette or console head, the AHRI listing changes, and so does the amount: we confirm it in the quote.
Source: Samsung FJM Premium submittals (02142025A); Hydro-Québec’s LogisVert list, all-wall-head listings, read Oct. 26, 2026 (“Puissance à -8 °C”); SEER2 and HSPF2: Samsung’s “Non-ducted” column and the ENERGY STAR record for each AHRI number.
Three heads: is your trio in Samsung’s table?
Pick each room’s head. The tool looks the trio up in all four units’ tables. With three heads, when a unit refuses, it’s because the total is too high.
Sizes come from the load calculation for each room, done at the visit. Here you see what Samsung’s combination table accepts, unit by unit.
No FJM Premium lists this set. Change a size, or talk to us at the visit.
Why a refusal: our reading of Samsung’s tables, where each unit has two limits, the heads’ total and the biggest head. Separate units: one Max Heat of the same size per room (a 7,000 head becomes a 9,000, the smallest Max Heat); under 12,000 BTU/h, no amount. The LogisVert guide doesn’t say whether several systems in one home each get an amount, so we never add them up.
Source: combination tables in Samsung FJM Premium submittals (02142025A); amounts: Hydro-Québec’s LogisVert list, all-wall-head listings, read Oct. 26, 2026; Max Heat: same list, Oct. 14, 2026.
Living room first: its head decides what’s left for the bedrooms.
In a three-room bungalow, pick the head for the big room. We show, unit by unit, the pairs Samsung accepts for the two bedrooms.
Bedrooms at 7,000 + 7,000: on the 20,000 · 24,000 · 30,000 · 36,000
Bedrooms at 7,000 + 9,000: on the 24,000 · 30,000 · 36,000
Bedrooms at 7,000 + 12,000: on the 24,000 · 30,000 · 36,000
Bedrooms at 9,000 + 9,000: on the 24,000 · 30,000 · 36,000
Bedrooms at 9,000 + 12,000: on the 30,000 · 36,000
Bedrooms at 12,000 + 12,000: on the 30,000 · 36,000
Bedrooms at 7,000 + 7,000: on the 24,000 · 30,000 · 36,000
Bedrooms at 7,000 + 9,000: on the 24,000 · 30,000 · 36,000
Bedrooms at 7,000 + 12,000: on the 30,000 · 36,000
Bedrooms at 7,000 + 15,000: on the 30,000 · 36,000
Bedrooms at 9,000 + 9,000: on the 30,000 · 36,000
Bedrooms at 9,000 + 12,000: on the 30,000 · 36,000
Bedrooms at 9,000 + 15,000: on the 30,000 · 36,000
Bedrooms at 12,000 + 12,000: on the 30,000 · 36,000
Bedrooms at 12,000 + 15,000: on the 36,000
Bedrooms at 15,000 + 15,000: on the 36,000
Bedrooms at 7,000 + 7,000: on the 24,000 · 30,000 · 36,000
Bedrooms at 7,000 + 9,000: on the 30,000 · 36,000
Bedrooms at 7,000 + 12,000: on the 30,000 · 36,000
Bedrooms at 7,000 + 15,000: on the 30,000 · 36,000
Bedrooms at 7,000 + 18,000: on the 36,000
Bedrooms at 9,000 + 9,000: on the 30,000 · 36,000
Bedrooms at 9,000 + 12,000: on the 30,000 · 36,000
Bedrooms at 9,000 + 15,000: on the 36,000
Bedrooms at 9,000 + 18,000: on the 36,000
Bedrooms at 12,000 + 12,000: on the 36,000
Bedrooms at 12,000 + 15,000: on the 36,000
Bedrooms at 12,000 + 18,000: on the 36,000
Bedrooms at 15,000 + 15,000: on the 36,000
Bedrooms at 7,000 + 7,000: on the 30,000 · 36,000
Bedrooms at 7,000 + 9,000: on the 30,000 · 36,000
Bedrooms at 7,000 + 12,000: on the 36,000
Bedrooms at 7,000 + 15,000: on the 36,000
Bedrooms at 9,000 + 9,000: on the 36,000
Bedrooms at 9,000 + 12,000: on the 36,000
Bedrooms at 9,000 + 15,000: on the 36,000
Bedrooms at 12,000 + 12,000: on the 36,000
The bigger the living room head, the smaller the bedrooms must be, except on the 36,000, which has room up to 48,000 BTU/h of heads. With a 24,000 living room head, the 30,000 leaves the bedrooms only 7,000 + 7,000 or 7,000 + 9,000; the 36,000 offers eight. The plan cycles on its own; tap a pair to see it. Exact sizes come from each room’s load calculation, at the visit.
Source: three-head tables in Samsung FJM Premium submittals (02142025A): each pair is a table row where the living room head is the biggest of the three. Head widths: FJM technical data book Ver. 1.2. Illustrative plan.
The 20,000 has three ports. Here, it fills them all.
The
ENERGY STAR cold climate certified, per this listing’s ENERGY STAR record (ID 3891562).
7 + 7 + 15 29,000 BTU/h: over the 20,000’s 27,000. For a 15,000 in the trio, you need the 24,000 (7 + 7 + 15 or 7 + 9 + 15).
With three heads on the 20,000, the heads never add up to less than the unit’s index: 21,000 to 27,000 BTU/h, for an index of 21. The percentages are our math; Samsung publishes none.
Source: Samsung
Three rooms, three ways to deliver air: wall, console, cassette.
With three heads, each room can have its own family. For example: a 7,000 wall head in a bedroom, a 9,000 console under a window, a 9,000 mini cassette in a drop ceiling. 7,000 + 9,000 + 9,000 = 25,000: that total is in all four units’ tables. Samsung notes that restrictions apply by head type, so we confirm it in the quote.
The only family offered in 7,000 and 24,000. WindFree mode in summer.
- 7,000 to 24,000 BTU/h
Nothing on the wall. One slim duct serves one room, per Samsung.
- 9,000, 12,000, 18,000 BTU/h
Panel sized for a 2 × 2 ft ceiling grid, WindFree mode in summer.
- 9,000, 12,000, 18,000 BTU/h
Often under a window. The 15,000 is multi-zone only.
- 9,000, 12,000, 15,000, 18,000 BTU/h
Source: Samsung FJM Premium submittals (02142025A), compatibility matrix (“** Restrictions apply”); Samsung model lists by family; slim duct manual
Three heads, three lines, one outdoor unit.
Three lines leave the same unit. Switch between wall heads and a mix of families: each room keeps its own line and setting.
Illustration. Ports and limits: Samsung FJM Premium submittals (02142025A); start-up: installation manual
Three lines, 230 ft in all: the third one gets what’s left.
Each head can sit 82 ft from the outdoor unit. But three times 82 is 246 ft, and Samsung caps the total at 230. Slide the three lengths.
109.3 oz factory charge: nothing to add, per Samsung, whatever the length.
With three heads, the limit that matters isn’t just the farthest head any more: it’s the sum. Three times 82 ft is 246 ft; with two lines at 82 ft, the third stops at 66 ft (20 m), our math. At least 10 ft per head, against noise and vibration, per Samsung. We measure all three runs at the visit. The example plays on its own until you touch a slider.
Source: Samsung FJM Premium submittals (02142025A): “Max. Individual Line Set Length 82 ft”, “Max. Line Set Length (total) 230 ft”; installation manual
One head per floor, basement to upstairs: 25 ft apart at most.
One head in the basement, one on the main floor, one upstairs: it works as long as the highest and lowest stay within 25 ft (7.5 m) of each other. Set the floor-to-floor height and how high each head goes.
The main floor doesn’t count toward the gap: only the highest and lowest heads do. With one head per level at the same height, floors must be 12.3 ft apart or less (our math). Samsung asks to mount heads 5.9 ft or more off the floor. Illustrative house: main floor at grade, main-floor head at 7 ft.
Source: Samsung installation manual
Three bedrooms, one R-32 charge: each needs at least 117 to 125 sq ft.
Samsung’s manual sets a minimum floor area for any room that holds an
Dashed: 125 sq ft (11.6 m²), the table’s 3.2 kg row for a wall head. Drawn to scale.
Samsung’s table is “Calculated in accordance with UL 60335-2-40 Annex GG”; the charge that counts is the whole system’s, 109.3 oz (3.1 kg) on every FJM Premium. Samsung doesn’t say whether the heads’ leak detector changes the area required, and local rules may add to it. The same table asks for 352 to 375 sq ft for a floor console, and 84.4 to 90.1 sq ft for a ceiling head at 2.5 m. For comparison, a Max Heat 9,000 single-zone holds 34.0 oz (0.96 kg), under the 1.836 kg “no restriction” row.
Source: Samsung installation manual
Three rooms here. Two or four? Switch pages.
Multi-zone 2 heads
4 outdoor units, 20,000 to 36,000; from 14,000 BTU/h of heads.
See the pageMulti-zone 3 heads
4 outdoor units, 20,000 to 36,000; from 21,000 BTU/h of heads.
You’re hereMulti-zone 4 heads
3 outdoor units, 24,000 to 36,000; from 28,000 BTU/h of heads.
See the pageSource: combination tables in Samsung FJM Premium submittals (02142025A): 62 pairs, 83 trios, 55 sets of four; samsunghvac.com, “up to four zones with one outdoor unit”.
Three small bedrooms: one FJM 20,000, or three 9,000 wall units?
Both heat and cool. What changes: the number of outdoor units, the LogisVert amount, the lowest heating temperature and the distances allowed. Switch to count the boxes outside.
| FJM 20,000 (9,000 + 9,000 + 9,000) | 3 × Max Heat 9,000 | |
|---|---|---|
| Outdoor units | 1 · 191.8 lb · 37 × 47 5/8 × 13 in | 3 · 71.0 lb each (213.0 lb) · 3 × 31 1/8 in = 93 3/8 in side by side |
| LogisVert | $1,584 (AHRI 216372795, all wall heads) | $0: each unit is 9,000 BTU/h in cooling, under the 12,000 minimum |
| Heats down to | -25 °C; 100% down to -15 °C, per Samsung | -30 °C; 100% down to -20 °C, per Samsung |
| Lines | 82 ft per head, 230 ft in total | 66 ft per unit |
| Max breaker | 40 A | 20 A per unit |
| 109.3 oz, nothing to add | 3 × 34.0 oz = 102.0 oz for 24.6 ft each, more beyond |
Three small 9,000 bedrooms: as separate wall units, none gets a LogisVert amount, and three units go outside. The FJM 20,000 puts one out there, with $1,584.
Source: Samsung FJM Premium (02142025A) and WindFree Max Heat (10072024A) submittals; Hydro-Québec’s LogisVert list (FJM: Oct. 26, 2026; Max Heat: Oct. 14, 2026). Widths and sums: our math.
One triple-zone, one AHRI number: $1,584 to $2,760.
Hydro-Québec’s math starts from the installed combination’s certified capacity at -8 °C. Three heads or two, a multi-zone has one outdoor unit and one AHRI number: one amount for the system. Pick a unit.
Source: Hydro-Québec, list of heat pumps eligible for LogisVert (owner, existing home), read Oct. 26, 2026, by AHRI number; the list prevails and the final amount is confirmed when you apply. With ducted heads or a mix of heads, the AHRI listing changes, and so does the amount: each unit’s three listings are on the 2-head page. The program rules are explained once, on the Samsung page.
The 3-head plate, unit by unit.
The four outdoor units that take three heads, side by side, with Samsung’s own term under each row. Where Samsung publishes nothing, the cell says so.
| Outdoor unit | 20,000 | 24,000 | 30,000 | 36,000 |
|---|---|---|---|---|
| Identification | ||||
| Outdoor unitModel (US code) | ||||
| Ports3 / 4 Port Condensing Unit | 3 | 4 | 4 | 4 |
| Capacity indexCapacity Index | 21 | 24 | 30 | 36 |
| AHRI number, all wall headsMultizone All Non-Ducted | 216372795 | 216372794 | 216372793 | 216372792 |
| ENERGY STAR ID, all wall headsENERGY STAR Unique ID | 3891562 | 3891561 | 3891560 | 3891558 |
| LogisVert, Hydro-Québec listOct. 26, 2026, all wall heads | $1,584 | $1,824 | $2,100 | $2,760 |
| With 3 heads | ||||
| Combinations in the table3-unit rows | 5 trios | 11 trios | 26 trios | 41 trios |
| Connected heads, lightest to heaviestBTU/h | 21,000 to 27,000 | 21,000 to 32,000 | 21,000 to 40,000 | 21,000 to 48,000 |
| Share of the index (our math) | 100 to 129 % | 88 to 133 % | 70 to 133 % | 58 to 133 % |
| Largest head allowedBTU/h | 12,000 | 18,000 | 24,000 | 24,000 |
| Free ports | 0 of 3 | 1 of 4 | 1 of 4 | 1 of 4 |
| Heating, all wall heads | ||||
| Rated capacity, cooling / heatingRated capacity, non-ducted (BTU/h) | 21,000 / 22,000 | 25,000 / 25,000 | 28,400 / 28,600 | 34,000 / 36,600 |
| Heat at 8.3 / -8.3 / -15 °CENERGY STAR, 47 / 17 / 5 °F | 22,000 / 13,200 / 22,000 | 25,000 / 15,200 / 25,000 | 28,600 / 17,500 / 28,600 | 36,600 / 23,000 / 36,600 |
| COP at 8.3 / -8.3 °CNEEP, 47 / 17 °F | 4.64 / 2.95 | 4.70 / 2.89 | 3.99 / 2.83 | 4.21 / 2.45 |
| COP at -15 °CENERGY STAR, 5 °F | 1.95 | 1.85 | 1.81 | 2.04 |
| Coldest point listed on NEEP, -25 °CNEEP, -13 °F | up to 18,000 BTU/h · COP 1.61 | up to 18,000 BTU/h · COP 1.61 | up to 20,000 BTU/h · COP 1.87 | up to 20,000 BTU/h · COP 1.87 |
| Min / max capacity at 8.3 °CNEEP, 47 °F | 7,600 / 32,000 | 7,600 / 42,000 | 7,600 / 54,500 | 7,600 / 54,500 |
| Efficiency | ||||
| SEER2 / EER2Non-ducted | 23.00 / 15.00 | 23.00 / 14.55 | 22.50 / 13.50 | 21.50 / 12.50 |
| HSPF2, region IV / region VSamsung · NEEP | 10.5 / 7.1 | 10.4 / 7.1 | 10.0 / 6.9 | 9.5 / 7.7 |
| Sound | ||||
| Outdoor, cooling / heating, highSound Pressure Level, dB(A) | 50 / 51 | 51 / 52 | 52 / 53 | 52 / 53 |
| Distance and test conditions | not published | not published | not published | not published |
| Installation | ||||
| Power · MCA / max breaker1 / 208-230 / 60 | 35.9 A / 40.0 A | 35.9 A / 40.0 A | 35.9 A / 40.0 A | 35.9 A / 40.0 A |
| Liquid / gas connectionsHigh side / Low side (suction), in | 1/4 × 3 / 3/8 × 3 | 1/4 × 4 / 3/8 × 2 + 1/2 × 2 | 1/4 × 4 / 3/8 × 2 + 1/2 × 2 | 1/4 × 4 / 3/8 × 2 + 1/2 × 2 |
| Adapters includedIncluded Pipe Adapters, in | 1 × 3/8 × 1/2 | 2 × 1/2 × 3/8 | 2 × 1/2 × 3/8 | 2 × 1/2 × 3/8 + 2 × 1/2 × 5/8 |
| 109.3 oz (3,100 g) · 230 ft | 109.3 oz (3,100 g) · 230 ft | 109.3 oz (3,100 g) · 230 ft | 109.3 oz (3,100 g) · 230 ft | |
| Lines: per head / total / minimumft | 82 / 230 / 10 ft | 82 / 230 / 10 ft | 82 / 230 / 10 ft | 82 / 230 / 10 ft |
| Rise: to the outdoor unit / between headsft | 49 / 25 ft | 49 / 25 ft | 49 / 25 ft | 49 / 25 ft |
| Outdoor W × H × D · weightin · lb | 37 × 47 5/8 × 13 in · 191.8 lb | 37 × 47 5/8 × 13 in · 194.0 lb | 37 × 47 5/8 × 13 in · 194.0 lb | 37 × 47 5/8 × 13 in · 194.0 lb |
| Base pan heaterSamsung: “as standard” · NEEP | standard · 150 W per NEEP | standard · 150 W per NEEP | standard · 150 W per NEEP | standard · 150 W per NEEP |
- The distance and conditions behind the sound figures, indoors and out.
- The base pan heater’s power: Samsung writes “as standard”, NEEP lists 150 W.
- How to read its model numbers: Samsung writes them with wildcards (AJ0**DXS*CG).
- What happens, for the user, when one head calls for heat and another for cooling: the manual doesn’t describe it.
Sources: Samsung FJM Premium submittals (02142025A; 24,000 and 36,000 adapters re-read Oct. 26, 2026) and combination tables; manual
Three Samsung heads, three line runs, one crew.
Samsung makes the unit and sets the limits. AirGreen measures the three runs and the three rooms, installs and starts it up.
What SAMSUNG brings
- 83 three-head combinationsIn Samsung’s tables, on four units.
- Up to 48,000 BTU/h of headsOn the 36,000, with three heads.
- 230 ft for three linesAnd 82 ft at most for any one, per Samsung’s submittals.
- 109.3 oz from the factoryNothing to add, whatever the line length, per Samsung.
What AirGreen brings
- Sold and installed by AirGreenThe visit, the quote, the install and the start-up.
- Three runs measured at the visitAnd the height between the highest and lowest head.
- Every bedroom measuredFor the
R-32 minimum floor area in Samsung’s table. - RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16.
The triple-zone, in six claims.
True or false? Flip the cards: the answers come from Samsung’s submittals and manuals, and Hydro-Québec’s list.
Beyond 25 ft of line, refrigerant must be added.
FJM wall heads have a refrigerant leak detector.
All three heads must be on the same floor.
On a 3-head FJM 20,000, a 12,000 head is only allowed with two 7,000 heads.
A 3-head FJM 30,000 accepts a 24,000 head.
Per Samsung’s
These apply across the Samsung range: they have their own page, so we don’t repeat them here.
What people ask about Samsung triple-zones.
7,000 × 3 and 9,000 × 3: all four units. 12,000 × 3: the 30,000 and 36,000. 15,000 × 3: the 36,000 only. 18,000 × 3 (54,000): not in any table.
No. With two 7,000s that’s 29,000 BTU/h of heads, and the 20,000 stops at 27,000. You need at least the 24,000 (7,000 + 7,000 + 15,000 or 7,000 + 9,000 + 15,000).
On the 24,000, 30,000 and 36,000, yes: four ports for three heads. The 20,000 has three ports, all in use.
Yes, per the
No. 3 × 82 = 246 ft, and Samsung allows 230 ft in total. With two lines at 82 ft, the third stops at 66 ft (20 m), our math.
Yes, as long as the highest and lowest heads stay within 25 ft (7.5 m) of each other, and within 49 ft (15 m) of the outdoor unit, per Samsung.
No. The math uses the system’s AHRI number, and a multi-zone has only one: $1,584 (20,000) to $2,760 (36,000) with wall heads, per Hydro-Québec’s list.
No question matches. Call us: 514 316-2973.
One room on its own? A wall unit or a console.
One more room, off the multi-zone circuit: a single-zone Samsung wall unit or console. And for a house with ducts, the Hylex central system.

SAMSUNG wall-mounted heat pumps
WindFree Standard and Max Heat, 9,000 to 24,000 BTU/h.
See the collection
Hylex central heat pumps
Standard and Premium, 2 to 5 tons, on your ducts.
See the collection
“Add-on” central systems
A Hylex coil on the furnace you keep.
See the collection
Hylex electric furnaces
The Hylex indoor unit in place of an electric furnace.
See the collection
SAMSUNG ducted units
Slim duct hidden in a ceiling or closet.
See the collection
SAMSUNG ceiling cassettes
WindFree mini 4-way cassette, 2 × 2 ft.
See the collection
SAMSUNG floor consoles
Low on the wall, often under a window.
See the collection
SAMSUNG thermostats and Wi-Fi
Wired controllers and Wi-Fi adapter.
See the collectionThree rooms, one Samsung outdoor unit, installed by AirGreen.
We measure the three rooms and the three line runs, pick the heads and the outdoor unit with you, and hand you a clear quote with the AHRI number and the LogisVert amount from Hydro-Québec’s list.
Hydro-Québec does no phone or door-to-door solicitation for LogisVert. A call “from Hydro-Québec” selling a heat pump? Hang up.


Sources checked on October 14 and 26, 2026
- Samsung FJM Premium submittals
AJ020DXS3CG and AJ024/030/036DXS4CG, version 02142025A (files of Jan. 14, 2026), combination tables included; read Oct. 14, 2026, AJ024 and AJ036 re-read Oct. 26, 2026. - Samsung installation manuals
DB68-13175A-00 (FJMR-32 outdoor unit) andDB68-13426A-01 (AJ0**DNADCG wall heads); technical data book “Free Joint Multi … (R32, 60Hz, HP)”, Ver. 1.2 (head data). - samsunghvac.com, “Free Joint Multi Premium” page, read Oct. 14, 2026.
- ENERGY STAR, Certified Air-Source Heat Pumps (dataset w7cv-9xjt), records read by AHRI number on Oct. 14, 2026.
- NEEP, Cold Climate Air Source Heat Pump List, records read by AHRI number on Oct. 14, 2026 (listing classes, COP, coldest point, base pan heater).
- Hydro-Québec, list of heat pumps eligible for LogisVert (owner, existing home): file of Oct. 14, 2026, FJM rows re-read Oct. 26, 2026; Participation guide v1.10 (Sept. 15, 2026).
- Samsung WindFree Max Heat submittals (10072024A) and AR**DX*** wall-unit installation manual, for the comparisons with separate wall units.
LogisVert amounts are indicative: Hydro-Québec confirms them when you apply. Prices on quote.
Our 3-head Samsung multi-zones, right below.
Each listing gives the outdoor unit, the AHRI number and the certified ratings. The head sizes allowed are those in Samsung’s table, above.