AirGreen × SAMSUNGUnder the window, where the radiator wasHeat from top and bottomRechargeable remote includedFloor, wall or half-concealedENERGY STAR cold climateMontreal · Laval · Longueuil · South Shore · North Shore
01 · Which size?

Four consoles, one LogisVert amount: the 18,000.

Three single-zone sizes, plus a 15,000 that only goes on a multi-zone. Pick a size: models, AHRI number, certified heat at -8 °C and the math, or the reason when there is no amount.

1What size?
Samsung floor console

Not sure about the size? We work it out on site: insulation, windows, orientation, ceiling height.

02 · Where it goes

Under the window, where the radiator was.

Where the radiator was

Samsung calls it a great option for replacing a radiator, sitting on the floor or hung low on the wall.

The remote in the box

Rechargeable by USB-C cable or its own solar panel, per Samsung. The front also has touch controls, a display and an infrared receiver.

Three sizes, plus one

9,000, 12,000 and 18,000 as single-zone; the 15,000 only goes on an FJM Premium multi-zone.

199 mm into the room

720 × 620 mm front, 199 mm deep: we measure the height under your window at the visit.

03 · The air outlets

Heating uses both outlets. Cooling uses one.

The console blows from the top, with a motorized louver. In heating, the bottom outlet, set by hand, also sends heat along the floor. Pick the mode.

WindowTop outlet (motorized louver)Bottom outlet, in heatingIn cooling: top outlet onlyHeating: 318 CFMCooling: 300 CFM12,000, high speed4°40°

Illustration. Sources: Samsung Console submittals (10072024A / 02132025A); Console data book Ver. 1.1, section 9 (“Discharge angle : 4 degree” in heating, “40 degree” in cooling).

04 · Three ways to mount it

On the floor, on the wall, or half in the wall.

Samsung calls it a great option for replacing a radiator: it sits on the floor, hangs low on the wall, or goes halfway into the wall. Pick the mount.

wallwindowfloor199 mm

Source: Samsung installation manual DB68-12932A-02: p. 8 (“Bracket Hanger (1)” supplied), p. 11 (sloped floor), p. 12 (“Case 1. Installing on the floor: You must secure the unit to the wall using 4 screws”, “Case 2. Hanging on the wall”), p. 17 (step 10, half-concealed install: dimensions 104, 199 and 95 mm; the drawing’s text doesn’t say which one is in the wall); Samsung Console page (“can sit on the floor or hang low on a wall”). Illustration.

05 · No pump

No pump: the water has to run downhill all the way.

The console has no built-in condensate pump. Water leaves through a 65 mm hole in the wall and drains by gravity. Four routes: only one follows Samsung’s rules. Which one?

Tap the route that follows Samsung’s rules.

Source: Samsung installation manual DB68-12932A-02, p. 16: “The hose must NOT slant upwards”, “Keep a clearance of at least 1.97 inch (5cm) between the end of the hose and the ground”, “The end of the drain hose must NOT be placed under water”, “Do NOT place the end of the drain hose in a hollow”, 65 mm hole, 2 m extension; p. 8 (one drain hose in the box); Console submittal 02132025A (Ghost 83809 and 83909, Blue Diamond MicroBlue X86-003 and X86-011 pumps). Illustrations.

06 · R-32 and room size

18,000 console: past 16.5 m of line, room size counts.

R-32 is an A2L refrigerant, mildly flammable per ASHRAE. For a floor console, Samsung sets a minimum floor area based on the system’s total charge. The 9,000 and 12,000 never need one; the 18,000 only does with long lines. Slide the length.

The size
5 m7.5 m20 m
5 m7.5 m20 m
5 m16.5 m30 m50 m
Samsung’s table, floor console
  • ≤ 1.836 kgno limit
  • 1.837 kg20.0 m²
  • 1.9 kg20.7 m²
  • 2.0 kg21.8 m²
  • 2.2 kg24.0 m²
  • 2.4 kg26.1 m²

Did you know: for 2.0 kg of R-32, Samsung asks for 21.8 m² of floor for the console, against 5.23 m² for the mini cassette mounted at 2.5 m. On the floor, the table is about four times stricter.

Source: Samsung installation manual DB68-12932A-02: p. 5 (“pre-charged with mildly flammable gas classified as A2L by ASHRAE”), p. 7 (sensor, E700), pp. 8-9 (“Floor-standing (with R-32 sensor)” table, 0.6 m reference height, “m : Total refrigerant charge in the system”, UL 60335-2-40 Annex GG); manual DB68-12928A-04, p. 8 (5.23 m² at 2.0 kg, 2.5 m); Console submittals (31.7 and 60 oz factory charge for 24.6 ft, 0.161 oz per foot, 38.4 and 82.4 oz max, 66 and 164 ft max). NIST SP 811 conversions. AirGreen math, cautious reading: the table row equal to or above the charge.

07 · 9,000 or 12,000?

At -20 °C, the 12,000 gives just 100 BTU/h more than the 9,000.

Outside, the 9,000 and 12,000 consoles use the same outdoor unit. In deep cold, their heat runs neck and neck, and the 12,000 gets no LogisVert amount. Slide the temperature.

ENERGY STAR certified, kept apart: a different test
Measure9,00012,00018,000
Rated heat at 8.3 °C10,10013,00019,000
Certified heat at -8.3 °C8,0007,60011,900
Certified cooling9,00010,20016,000
LogisVertnonenone$1,428

Did you know: outside, the 9,000 and the 12,000 use the same unit, 31 1/8 × 21 5/8 × 11 3/16 in, 67.2 lb, 31.7 oz of R-32 and 13.9 A. The slider values come from Samsung’s data book, 21 °C indoor air; they don’t compare with the heat certified at -8 °C, which is what LogisVert uses.

Source: Samsung Console technical data book Ver. 1.1 (24.12.06), section 4, heating capacity table, 70 °F (21 °C) indoor column, total capacity (TC) and power input (PI) at 32, 14, -4 and -13 °F; NEEP (same values at -25 °C); ENERGY STAR w7cv-9xjt (AHRI 216441748, 216441749, 216441726); submittals (outdoor units); Hydro-Québec LogisVert list, re-read Oct 26, 2026.

08 · Hydro-Québec LogisVert

Up to $1,428, checked by AHRI number.

ENERGY STAR cold-climate certified: $120 per 1,000 BTU/h of heat at -8 °C, from 12,000 BTU/h. Pick a size to see the math, or the reason when there is no amount.

ENERGY STAR cold climate: $120 / 1,000 BTU/hNo amount (reason shown)
ENERGY STAR required

For installations completed on or after November 26, 2025, the unit must be ENERGY STAR certified.

12,000 BTU/h minimum

The outdoor unit needs a nominal cooling capacity of at least 12,000 BTU/h.

Nine months to apply

Apply no later than nine months after installation. The grant never exceeds 100% of the pre-tax cost.

The AHRI number decides

The amount follows the installed combination, outdoor and indoor, as listed under its AHRI number.

Source: Hydro-Québec, list of heat pumps eligible for LogisVert (owner, existing home), by AHRI number, re-read Oct. 26, 2026; Participation guide v1.10 (Sept. 15, 2026). Hydro-Québec’s list prevails; the final amount is confirmed when you apply. Our LogisVert guide

09 · The spec sheet, made clear

The console, size by size.

Size, weight, sound, airflow and line limits: Samsung’s numbers. Pick a size. The 15,000 connects only to an FJM multi-zone.

SAMSUNGFloor console · 9,000 BTU/h
IndoorAC009DNJDCG
OutdoorAC009DXSCCG
AHRI216441748
RefrigerantR-32 · 31.7 oz factory charge
Power208-230 V · 60 Hz · MCA 13.9 A
SEER2 / EER2 / HSPF221.0 / 12.7 / 9.7
Samsung submittal, CAC PremiumAIRGREEN SUMMARY

Outdoor unit · 67.2 lb

31 1/8 in21 5/8 in11 3/16 in

Console · 34.6 lb

28 3/8 in24 3/8 in7 13/16 in

Sound, with everyday references

Silence 24High 35Outdoor 5320
Rustling leaves
30
Whisper
40
Quiet library
50
Moderate rain
60
Conversation

References in dB: American Academy of Audiology. The unit’s values are those Samsung publishes, in dB(A); the references only give a sense of scale.

300 CFMheating airflow (265 in cooling)
9,000 BTU/hrated cooling with the outdoor unit
Nobuilt-in condensate pump
66 ftof line at most, 49 ft vertical
24.6 ftof line pre-charged with refrigerant
35 Wturbo fan (output)
SAMSUNGFloor console · 12,000 BTU/h
IndoorAC012DNJDCG
OutdoorAC012DXSCCG
AHRI216441749
RefrigerantR-32 · 31.7 oz factory charge
Power208-230 V · 60 Hz · MCA 13.9 A
SEER2 / EER2 / HSPF221.0 / 12.2 / 9.5
Samsung submittal, CAC PremiumAIRGREEN SUMMARY

Outdoor unit · 67.2 lb

31 1/8 in21 5/8 in11 3/16 in

Console · 34.6 lb

28 3/8 in24 3/8 in7 13/16 in

Sound, with everyday references

Silence 24High 38Outdoor 5420
Rustling leaves
30
Whisper
40
Quiet library
50
Moderate rain
60
Conversation

References in dB: American Academy of Audiology. The unit’s values are those Samsung publishes, in dB(A); the references only give a sense of scale.

318 CFMheating airflow (300 in cooling)
10,200 BTU/hrated cooling with the outdoor unit
Nobuilt-in condensate pump
66 ftof line at most, 49 ft vertical
24.6 ftof line pre-charged with refrigerant
35 Wturbo fan (output)
SAMSUNGFloor console · 18,000 BTU/h
IndoorAC018DNJDCG
OutdoorAC018DXSCCG
AHRI216441726
RefrigerantR-32 · 60.0 oz factory charge
Power208-230 V · 60 Hz · MCA 22.7 A
SEER2 / EER2 / HSPF220.0 / 12.2 / 9.5
Samsung submittal, CAC PremiumAIRGREEN SUMMARY

Outdoor unit · 116.84 lb

34 5/8 in31 3/8 in12 3/16 in

Console · 35.1 lb

28 3/8 in24 3/8 in7 13/16 in

Sound, with everyday references

Silence 32High 43Outdoor 5820
Rustling leaves
30
Whisper
40
Quiet library
50
Moderate rain
60
Conversation

References in dB: American Academy of Audiology. The unit’s values are those Samsung publishes, in dB(A); the references only give a sense of scale.

388 CFMheating airflow (332 in cooling)
16,000 BTU/hrated cooling with the outdoor unit
Nobuilt-in condensate pump
164 ftof line at most, 98 ft vertical
24.6 ftof line pre-charged with refrigerant
35 Wturbo fan (output)

Sources: Samsung Console submittals (10072024A / 02132025A) and data book Ver. 1.1 (sound “H/M/L/Silence”). Sound: Silence and high speed. Dimensions W × H × D.

10 · Samsung plate

The full plate, size by size.

The three Console sizes side by side, with Samsung’s own term under each row. Where Samsung publishes nothing, the cell says so.

Console
Size9,00012,00018,000
Identification
Indoor unitIndoor unit · US CodeAC009DNJDCG (CNG09JDD)AC012DNJDCG (CNG12JDD)AC018DNJDCG (CNG18JDD)
Outdoor unitOutdoor unit · US CodeAC009DXSCCG (CXG09SCD)AC012DXSCCG (CXG12SCD)AC018DXSCCG (CXG18SCD)
AHRI numberAHRI Certified Ref. No.216441748216441749216441726
ENERGY STAR IDENERGY STAR Unique ID389155338915543891531
LogisVert, Hydro-Québec listre-read Oct. 26, 2026not listednot listed$1,428
Heating
Rated capacity, cooling / heatingNominal capacity (BTU/h)9,000 / 10,10010,200 / 13,00016,000 / 19,000
Heating rangeCapacity range, heating2,800 – 19,0002,900 – 19,5004,100 – 22,000
Heat at 8.3 / -8.3 °CENERGY STAR, 47 / 17 °F10,100 / 8,00013,000 / 7,60019,000 / 11,900
COP at 8.3 / -8.3 °CNEEP, 47 / 17 °F3.79 / 2.133.40 / 2.453.29 / 2.44
COP at -15 °CENERGY STAR, 5 °F1.801.801.80
Coldest certified point, -25 °CNEEP, -13 °Fup to 6,200 BTU/h · COP 1.53up to 6,500 BTU/h · COP 1.61up to 14,600 BTU/h · COP 1.70
Efficiency
SEER2 / EER2ENERGY STAR21.00 / 12.7021.00 / 12.2020.00 / 12.20
HSPF2, region IV / region VSamsung · NEEP9.70 / 7.89.50 / 7.69.50 / 7.6
Sound
Indoor, Silence / low / mid / highSound pressure, dB(A)24 / 29 / 31 / 3524 / 33 / 35 / 3832 / 35 / 39 / 43
Outdoor, high speedCooling / Heating (high), dB(A)53 / 5354 / 5458 / 58
Test conditionsnot publishednot publishednot published
Air and water
Airflow, cooling / heating (high)CFM265 / 300300 / 318332 / 388
Condensate pumpDrain pumpno: gravity, 65 mm holeno: gravity, 65 mm holeno: gravity, 65 mm hole
A2L leak detectionA2L Leak Detectionintegralintegralintegral
Installation
Power · MCA / MOP208-230 V, 1 ph, 60 Hz13.9 A / 15 A13.9 A / 15 A22.7 A / 25 A
Line setLiquid / gas (in)1/4 + 3/8 in1/4 + 3/8 in1/4 + 1/2 in
Max length / max riseft66 / 49 ft66 / 49 ft164 / 98 ft
Factory charge for 24.6 ft · maximumR-32, oz · trim 0.161 oz/ft31.7 · 38.4 oz31.7 · 38.4 oz60.0 · 82.4 oz
Outdoor W × H × D · weightin · lb31 1/8 × 21 5/8 × 11 3/16 in · 67.2 lb31 1/8 × 21 5/8 × 11 3/16 in · 67.2 lb34 5/8 × 31 3/8 × 12 3/16 in · 116.84 lb
Indoor W × H × D · weightin · lb28 3/8 × 24 3/8 × 7 13/16 in · 34.6 lb28 3/8 × 24 3/8 × 7 13/16 in · 34.6 lb28 3/8 × 24 3/8 × 7 13/16 in · 35.1 lb
What Samsung does not publish
  • The mounting height when the console hangs on the wall.
  • One size for the drain fitting: the submittal says 1 in inside diameter, the manual 12 mm. We measure the unit delivered.
  • The sound test conditions, and how to read the model numbers.

Sources: Samsung CAC Premium submittals (Slim Duct 02132025A; cassette and console 10072024A and 02132025A); Slim Duct data book Ver. 3.1 and Console data book Ver. 1.1; ENERGY STAR (w7cv-9xjt); NEEP, read by AHRI number on Oct. 14, 2026; Hydro-Québec’s LogisVert list re-read Oct. 26, 2026. HSPF2 region V comes from NEEP: Samsung prints region IV only. The 18,000s are rated under 18,000 BTU/h in cooling: that is their size class, not their rating. The 15,000 (AC015DNJDCG) has no single-zone pairing: it goes on an FJM multi-zone, whose AHRI number applies.

11 · AirGreen × SAMSUNG

Samsung built it for low on the wall. AirGreen picks which wall.

Samsung designs the console. We pick the wall, the drain slope and the size, then register it with Samsung.

SAMSUNG

What SAMSUNG brings

  • Heat from top and bottomTwo outlets in heating, one in cooling, per Samsung.
  • Remote includedRechargeable by USB-C or its own solar panel.
  • Built-in leak detectionIt stops the compressor and stirs the air if it detects a leak.
  • Single or multi-zoneOn its own outdoor unit, or as a head on an FJM Premium.
AirGreen

What AirGreen brings

  • Sold and installed by AirGreenThe visit, the quote, the installation and start-up.
  • The drain on a slopeOne 65 mm hole, and a hose that runs downhill all the way.
  • The room measuredOn the 18,000 with long lines, floor area counts.
  • RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16.
12 · True or false

The console, in six claims.

True or false? Each card flips to its source.

0/ 6

Pick True or False: the card flips to show the answer and its source.

01

The console is less than 8 in deep.

02

In cooling, air also comes out at the bottom.

03

At -8 °C, the 12,000 console heats less than the 9,000.

04

Its remote runs on disposable batteries.

05

It moves more air in heating than in cooling.

06

On a sloped floor, the console should lean toward its drain.

13 · Frequently asked questions

What people ask about the Samsung console.

The 9,000 is under the 12,000 BTU/h cooling minimum. With the console, the 12,000 is certified at 10,200 BTU/h in cooling: it is not on Hydro-Québec’s list (Oct. 26, 2026). The 15,000 goes on a multi-zone: the amount goes to the system.

In heating, from the top and the bottom; in cooling, through the motorized top vane, per Samsung.

720 × 620 × 199 mm (28 3/8 × 24 3/8 × 7 13/16 in) for the 9,000, 12,000 and 18,000, per Samsung. Samsung also allows a half-concealed install, partly inside the wall.

Down to -25 °C (-13 °F), per Samsung, with high heating capacity at -20 °C (-4 °F). At -25 °C, NEEP lists up to 6,200, 6,500 and 14,600 BTU/h for the 9,000, 12,000 and 18,000.

Not at 9,000 or 12,000: their charge stays under the 1.836 kg in Samsung’s table. The 18,000 passes that line beyond about 16.5 m of line; then it needs at least 20.0 m², and up to 26.1 m² at maximum length.

Partly. Samsung allows a half-concealed install, with about half of its 199 mm depth inside the wall. We check the wall, its framing and the drain path at the visit.

Yes: Samsung lists it among the heads compatible with FJM Premium multi-zone. The LogisVert amount then goes to the system. We confirm the combination in the quote.

Samsung’s submittals list it as built in; some Samsung web pages mention an adapter sold separately. We confirm it for your unit in the quote.

No, per Samsung. Water drains by gravity through the 65 mm (2.56 in) hole drilled in the wall. If the slope does not allow it, Samsung lists four third-party pumps as accessories.

Yes. The console comes with a rechargeable remote and its holder; it charges by USB-C cable or its own solar panel, per Samsung. The front panel also has its own touch controls and display.

No. Without a pump, it has to run downhill all the way and end at least 5 cm above the ground, never under water or in a hollow. Otherwise, Samsung lists four third-party pumps.

No question matches. Call us: 514 316-2973.

14 · The Samsung range

Rather high on the wall, or hidden? The rest of the line.

The full SAMSUNG page
AirGreen × SAMSUNGSold and installed by AirGreenHeats down to -25 °CLogisVert checked by AHRI numberFree home estimate

Sources checked October 14 to 26, 2026

  1. Samsung HVAC, Slim Duct, WindFree Mini 4-Way Cassette and Console pages; CAC Premium R-32 submittals (versions 10072024A and 02132025A).
  2. ENERGY STAR, Certified Air-Source Heat Pumps (dataset w7cv-9xjt), queried by AHRI number on Oct. 14, 2026.
  3. Hydro-Québec, residential LogisVert page and LogisVert Participation Guide v1.10 (Sept. 15, 2026), checked Oct. 8, 2026.
  4. airgreen.ca product pages, Oct. 8, 2026.
  5. Samsung CAC Premium R-32 submittals (Slim Duct 02132025A; WindFree Mini 4-Way Cassette and Console 10072024A and 02132025A), Slim Duct data book Ver. 3.1 and Console data book Ver. 1.1, installation manuals DB68-12926A-00, DB68-12928A-04 and DB68-12932A-02 (re-read Oct 26, 2026).
  6. American Academy of Audiology, “Levels of Noise in Decibels”, 2023 (sound references).
  7. NEEP, Cold Climate Air Source Heat Pump List, records read by AHRI number on Oct. 14, 2026 (COP, coldest certified point, HSPF2 region V).
  8. Hydro-Québec, list of heat pumps eligible for LogisVert (owner, existing home), re-read Oct. 26, 2026: amounts and “capacity at -8 °C”.
  9. NIST, SP 811, Appendix B (conversions: ounce, foot, square foot).

LogisVert amounts come from Hydro-Québec’s list, re-read Oct. 26, 2026; Hydro-Québec confirms them when you apply. Prices on quote.

The SAMSUNG shop

Our Samsung consoles, right below.

Each product page gives the models, the AHRI number, the dimensions and the certified performance.

AirGreenSAMSUNG
Prices on quote. Free home estimate.