Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
Hylex “add-on”: a heat pump on the furnace you keep.
A Hylex coil (HC series) goes on your furnace: the heat pump heats and cools through your ducts down to -25 °C, and the furnace takes over when needed. With the Premium, LogisVert is $1,812 (2 tons) or $2,592 (3 tons). We do not touch the burner or the gas or oil supply.
- Coils 17.5, 21 or 24.5 in wide
R-454B detector in the coilHA00A00203H1 controller required
LogisVert for the Hylex Premium 3-ton add-on. The furnace stays in place.
Hydro-Québec’s LogisVert list, re-read Oct. 26, 2026.
On your furnace: which Hylex, which coil?
Pick your options to see the models, the AHRI number, the heat at -8 °C, the LogisVert amount when there is one, and what to plan for.
Capacity is worked out during the visit, from the house and your ducts. Samsung recommends a two-stage thermostat.
For all: heating down to -25 °C per Samsung;

Hylex Premium · add-on 2 tons
HC36MBB021H1 + AC024FCUPCG · AHRI 218158139
Amount on Hydro-Québec’s LogisVert list (Oct. 26, 2026), $120 / 1,000 BTU/h at -8 °C
With an HC coil, Samsung also requires the HA00A00203H1 A2L mitigation controller.

Hylex Premium · add-on 3 tons
HC48MBC021H1 + AC036FCUPCG · AHRI 218158141
Amount on Hydro-Québec’s LogisVert list (Oct. 26, 2026), $120 / 1,000 BTU/h at -8 °C
With an HC coil, Samsung also requires the HA00A00203H1 A2L mitigation controller.
Hylex Premium · 4-ton add-on: on request
Samsung pairs it with the

Hylex Premium · add-on 5 tons
HC60MAD021H1 + AC060FCUPCG · AHRI 218331663
Combination not on the ENERGY STAR list: no LogisVert amount.
With an HC coil, Samsung also requires the HA00A00203H1 A2L mitigation controller.

Hylex Standard · add-on 2 tons
HC24MCB021H1 + AC024FCUDCG · AHRI 218226195
Not ENERGY STAR certified with the Samsung indoor unit: no LogisVert aid.
With an HC coil, Samsung also requires the HA00A00203H1 A2L mitigation controller.

Hylex Standard · add-on 3 tons
HC36MBB021H1 + AC036FCUDCG · AHRI 218158133
Not ENERGY STAR certified with the Samsung indoor unit: no LogisVert aid.
With an HC coil, Samsung also requires the HA00A00203H1 A2L mitigation controller.

Hylex Standard · add-on 4 tons
HC48MBC021H1 + AC048FCUDCG · AHRI 218158135
Not ENERGY STAR certified with the Samsung indoor unit: no LogisVert aid.
With an HC coil, Samsung also requires the HA00A00203H1 A2L mitigation controller.

Hylex Standard · add-on 5 tons
HC48MBC021H1 + AC060FCUDCG · AHRI 218158137
Not ENERGY STAR certified with the Samsung indoor unit: no LogisVert aid.
With an HC coil, Samsung also requires the HA00A00203H1 A2L mitigation controller.
Your furnace stays. The HC coil sits on top of it.
No HH unit here: the Hylex coil goes on your furnace, and the outdoor unit connects to it with two lines. We don’t touch the burner or the gas or oil supply.
- The Hylex HC coil, on the furnace
- The
MXD-U001XN control unit - The
HA00A00203H1 mitigation controller - The Hylex outdoor unit and its lines
- Your furnace
- Its burner
- The gas, oil or propane supply
- Your ducts
An electric furnace? The HH unit takes its place.
Your furnace, our heat pump, Hydro-Québec’s sensor.
An add-on brings several parties around one house. Tap a part of the diagram: we tell you who handles it.
AirGreenHydro-QuébecYou or your fuel specialist
Outdoor unit and lines
Sold and installed by AirGreen: the Hylex outdoor unit, the refrigerant lines and start-up. RBQ 5645-9605-01, subclasses 15.8, 15.10 and 16. We register the unit with Samsung.
HC coil
AirGreen sets the Hylex coil on the furnace, with its built-in
Control unit and mitigation
The
Thermostat
For dual fuel, Samsung requires a Samsung communicating control or a 24 V thermostat that supports it, and recommends a 2-stage thermostat.
Burner and fuel supply
Not us. We don’t touch the burner or the gas or oil supply: that’s for your fuel specialist.
Outdoor sensor
On Rate DT, Hydro-Québec supplies and installs it. It drives the switch between sources.
On Rate DT only.
Double-register meter
On Rate DT, Hydro-Québec installs a meter that measures electricity at the two prices.
On Rate DT only.
Indicator light
Optional, supplied free by Hydro-Québec: it shows which price your electricity is billed at.
On Rate DT only.
Dual-energy compliance attestation
Hydro-Québec asks the contractor to fill it in; you sign it to confirm you want Rate DT.
On Rate DT only.
For Rate DT, Hydro-Québec itself lists a conventional central heat pump among the accepted electric modes. Simplified illustration.
Source: Hydro-Québec, Rate DT and How Rate DT works pages, read Oct. 14, 2026 (sensor, meter, light, attestation, one source at a time); Samsung
Drop the temperature: who heats?
With an add-on, the Hylex and your furnace share the winter, never heating together. Slide the temperature and change the switch point.
The
—
Never both at once
—
Source: Samsung,
The HC coil: built-in detector, separate mitigation control.
The Hylex coil sits on your furnace. It has its own
Illustration. Sources: Samsung Hylex submittal with coil (05052026);
On your furnace, a high-temperature polymer drain pan.
In summer, the coil makes water. Samsung designed its pan around that. Tap the points, pick your drain side, then block it to see what happens.
High-temperature polymer
“UV resistant drain pans are molded of high temperature (450°F) engineered polymer.” The pan is UV resistant, per Samsung.
Little standing water
A patented HydroTEC low-water-retention pan, per Samsung.
Against mould
A Microban antimicrobial additive slows mould in the pan, per Samsung.
Less air leakage
A foam drain seal cuts air leakage, per Samsung.
Two outlets
Two 3/4 in FPT drains at the front, left and right: we use the side that leads to your floor drain.
The control unit has an input for a float switch (CN950 port, dry contact). Full pan: the system shuts down, and you get a notice in SmartThings (internet needed) or on the Samsung wall control. Samsung supplies the wire; the switch itself is bought separately.
A curious fact: the coil’s drain pan has its own antimicrobial additive, Microban, per Samsung. Data read on the
Source: Samsung,
17.5, 21 or 24.5 in: measure your furnace.
Hylex coils come in three widths. Measure your furnace cabinet and pull the tape: we show you which ones match.
17.5 in
HC24MCB021H1 Standard 2 tHC36MBB021H1 Premium 2 t, Standard 3 t
21 in
HC36MCC021H1 not in our storeHC48MBC021H1 Premium 3 t, Standard 4 t, Standard 5 tHC60MBC021H1 Premium 4 t (on request)
24.5 in
HC60MCD021H1 not in our storeHC60MAD021H1 Premium 5 t
The Samsung sheet we checked doesn’t mention downflow.
Measure the furnace cabinet left to right where the air comes out. Jot down the brand and model too: it helps us prep the visit. Samsung makes three “60” class coils in two widths: 21 in and 24.5 in. Only the
Source: Samsung brochure HYLEXBR 02.2026-V2, p. 8 (widths of the seven HC coils);
On your furnace: two required Samsung parts.
With an HC coil, Samsung requires the
Required by Samsung on every Hylex, even with its own indoor unit, and sold separately. We include it in the quote.
Required by Samsung, sold separately. The detector is in the coil; the controller shuts the system down and runs the mitigation.
You need a Samsung communicating control or a 24 V thermostat that supports dual fuel, per Samsung. Two stages recommended.
Your furnace is the backup. Samsung heat kits go in the HH unit, not on a coil.
As an add-on, $1,812 or $2,592 with the Premium.
The 2- and 3-ton Premium add-ons are ENERGY STAR cold-climate certified. The 5-ton Premium add-on is not on the ENERGY STAR list, and the Standard is not certified. Pick a system to see the math.
HC48MBC021H1 + AC036FCUPCG · AHRI 218158141
HC36MBB021H1 + AC024FCUPCG · AHRI 218158139
HC60MAD021H1 + AC060FCUPCG · AHRI 218331663
Combination not on the ENERGY STAR list: no LogisVert amount.
HC36MBB021H1 + AC036FCUDCG · AHRI 218158133
Not ENERGY STAR certified with the Samsung indoor unit: no LogisVert aid.
July 8, 2027
Source: Hydro-Québec, list of heat pumps eligible for LogisVert (owner, existing home), amounts re-read Oct. 26, 2026, by AHRI number; Participation guide v1.10 (Sept. 15, 2026). Hydro-Québec’s list prevails; the final amount is confirmed when you apply. The program rules are explained once, on the Samsung page. Our LogisVert guide
Same outdoor unit, different coil: the amount changes.
LogisVert doesn’t pay for an outdoor unit, it pays for a pairing. Pick a Premium size and compare the HH unit with the HC coil.
- AHRI
- Heat at -8 °C
- LogisVert
- SEER2 · COP at -15 °C
- AHRI
- Heat at -8 °C
- LogisVert
- SEER2 · COP at -15 °C
The 4-ton Premium with the
Amount = ENERGY STAR heat at -8 °C ÷ 1,000 × $120 (cold climate). The amounts shown are those on Hydro-Québec’s list; Hydro-Québec confirms them on application, capped at 100% of the pre-tax cost, claim within nine months. One pairing or the other: two choices, not two amounts to add up. At 3 tons, the add-on gets more than the central system, because its heat at -8 °C is higher.
Source: ENERGY STAR (w7cv-9xjt), re-read Oct. 26, 2026; Hydro-Québec’s LogisVert list, amounts re-read Oct. 26, 2026; participation guide v1.10; NEEP (218331663), read Oct. 14, 2026.
Heat pump + furnace: Hydro-Québec’s Rate DT.
A central heat pump with a gas, oil or propane furnace may qualify for Hydro-Québec’s Rate DT. Here are Hydro-Québec’s rules.
Electricity at -12 °C or warmer (or -15 °C, depending on the region); fuel below, per Hydro-Québec.
A temperature sensor that Hydro-Québec supplies and installs drives the switch from one source to the other.
Using both sources at once is not allowed on Rate DT. The Hylex works the same way in dual fuel.
Natural gas, oil, propane or wood pellets as backup. On the electric side, Hydro-Québec lists a conventional central heat pump.
A double-register meter measures electricity at the two prices. The account must qualify for rates D, DP or DM.
An indicator light shows which price your electricity is billed at. Hydro-Québec supplies it free; installing it is optional.
Source: Hydro-Québec, Rate DT and How Rate DT works pages, read Oct. 14, 2026. Rate DT conditions are set by Hydro-Québec: we tell you the steps. Hydro-Québec does not say which region switches at -12 °C and which at -15 °C.
The seven Hylex coils, side by side.
Samsung makes seven HC coils. We install five. Here is what Samsung publishes for each one, and what it doesn’t.
| Coil | |||||||
|---|---|---|---|---|---|---|---|
| Identification | |||||||
| WidthWidth (in.), brochure | 17.5 in | 17.5 in | 21 in | 21 in | 24.5 in | 21 in | 24.5 in |
| Our add-on systemspairing | Standard 2 t | Premium 2 t Standard 3 t | not in our store | Premium 3 t Standard 4 t Standard 5 t | not in our store | Premium 4 t (on request) | Premium 5 t |
| System AHRI numberAHRI Certified Ref. No. | 218226195* | 218158139 218158133 | not published | 218158141 218158135 218158137 | not published | 218159516 | 218331663 |
| System LogisVertHydro-Québec list | not listed | $1,812 not listed | not published | $2,592 not listed not listed | not published | $3,432 | not listed |
| Samsung sheet | |||||||
| W × H × D · weightIndoor Unit (in.) · lbs. | not published | not published | not published | not published | not published | 21 × 27 1/2 × 21 in · 58 lb | not published |
| Supply / returnSupply / Return (in.) | not published | not published | not published | not published | not published | 19.5 × 19.5 · 20 × 20.5 in | not published |
| Airflow min / maxAirflow Minimum / Maximum (CFM) | not published | not published | not published | not published | not published | 720 / 2,000 CFM | not published |
| PositionsMulti-position | not published | not published | not published | not published | not published | vertical, horizontal L and R | not published |
| DrainsCondensate Connection | not published | not published | not published | not published | not published | 2 × 3/4 in FPT, front left and right | not published |
| not published | not published | not published | not published | not published | built in | not published | |
| Required by Samsung | |||||||
| Mitigation controllerRequired Components | |||||||
| Control unitRequired Components | |||||||
- The dimensions, weight, airflow and positions of six of the seven coils: only the
HC60MBC021H1 sheet is published. - The HC coil installation manual and the
HA00A00203H1 controller’s sequence. - Which furnace fuels are accepted: the Samsung documents we read name none.
* Number found only in our store data: no NEEP or ENERGY STAR record. Sources: brochure HYLEXBR 02.2026-V2 (widths);
No fuel-burning furnace? Another Hylex page.
Electric furnace: the HH unit. To compare the lines: Premium and Standard.

Hylex Premium
Premium: $1,812 or $2,592 as an add-on.
See the collection
Hylex Standard
Standard: no LogisVert, lower at 2 and 3 t.
See the collection
“Add-on” central systems
You are here: the HC coil on your furnace.
You are here
Electric furnaces
Electric furnace? The HH unit takes its place.
See the collectionSamsung makes the coil. We add it and leave the burner alone.
Samsung designs the HC coil, its detector and the control unit. Sold and installed by AirGreen: the coil, the outdoor unit, the lines and the control unit. Gas and oil stay with a fuel specialist.
What SAMSUNG brings
- Cased HC coilBuilt-in
R-454B detector. - Polymer drain panHigh temperature, per Samsung.
- Control unitBetween the furnace, the thermostat and the outdoor unit.
- Dual fuelNever both sources at once.
What AirGreen brings
- Sold and installed by AirGreenThe visit, the quote, the installation and start-up.
- Free home estimateWe pick the range and tonnage with you, on site.
- Warranty registered for youWe register your unit with Samsung.
- RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16.
These apply to every Hylex: they have their own page, so we don’t repeat them here.
The Hylex add-on, in six claims.
True or false? Flip the cards.
With a Hylex add-on, your furnace stays in place.
In deep cold, the Hylex and the furnace heat together.
The Hylex coil has its own leak detector.
The
The Hylex coil’s drain pan has two drain outlets, one left, one right.
On Rate DT, a Hydro-Québec sensor decides the switch.
What people ask about the Hylex add-on.
No. We install the coil on the furnace and the heat pump outside; we don’t touch the burner or the gas or oil supply. That stays with your fuel specialist.
No. Samsung doesn’t allow the heat pump and a backup source to run at the same time, and Hydro-Québec rules out using both sources at once on Rate DT.
Maybe. For dual fuel, Samsung requires a Samsung communicating control or a 24 V thermostat that supports it, and recommends two stages. We check yours at the visit.
The one with the right width and the right pairing: Samsung coils are 17.5, 21 or 24.5 in wide. We measure the furnace at the visit.
It may: Hydro-Québec names the central heat pump among the accepted electric modes, with a fuel backup (natural gas, oil, propane or wood pellets). The sensor and the meter are installed by Hydro-Québec.
No question matches. Call us: 514 316-2973.
Far from the furnace: Samsung wall units, consoles and cassettes.
The rest of the Samsung range at AirGreen, sold and installed by us.

SAMSUNG wall-mounted heat pumps
WindFree Standard and Max Heat, 9,000 to 24,000 BTU/h.
See the collection
2, 3 or 4-head multi-zone
FJM Premium: up to 4 rooms on one outdoor unit.
See the collection
SAMSUNG ducted units
Slim duct hidden in a ceiling or closet.
See the collection
SAMSUNG ceiling cassettes
WindFree mini 4-way cassette, 2 × 2 ft.
See the collection
SAMSUNG floor consoles
Low on the wall, often under a window.
See the collection
SAMSUNG thermostats and Wi-Fi
Wired controllers and Wi-Fi adapter.
See the collectionYour furnace stays. Your Hylex joins it, installed by AirGreen.
We look at your ducts, your furnace and the right spot outside. Then a clear quote: range, tonnage, AHRI number, parts to plan for and indicative LogisVert amount.
Hydro-Québec does no phone or door-to-door solicitation for LogisVert. A call “from Hydro-Québec” selling a heat pump? Hang up.


Sources checked on October 26, 2026
- Samsung HVAC Hylex
R-454B spec sheets (2026), Hylex brochure (HYLEXBR 02.2026-V2) andMXD-U001XN control unit installation manual. - ENERGY STAR, Certified Air-Source Heat Pumps (dataset w7cv-9xjt), queried by AHRI number on Oct. 8, 2026, re-read Oct. 26, 2026.
- Hydro-Québec, residential LogisVert page and LogisVert Participation Guide v1.10 (Sept. 15, 2026), checked Oct. 8, 2026.
- Samsung HVAC 2026 spec sheets and warranty registration page (samsunghvac.com), checked Oct. 8, 2026.
- Samsung Hylex
R-454B submittals (outdoor units 02112026, HH air handler systems 04072026, HC coil 05052026), installation manualsDB68-13654A (outdoor),DB68-13653A (MXD-U001XN ) and 679608-01 (HH air handler), brochure HYLEXBR 02.2026-V2. - Hydro-Québec, Rate DT and How Rate DT works pages, read Oct. 14, 2026.
- ENERGY STAR, Certified Air-Source Heat Pumps (dataset w7cv-9xjt), Hylex records by AHRI number, re-read Oct. 26, 2026.
- NEEP, Cold Climate Air Source Heat Pump List, records read by AHRI number on Oct. 14, 2026.
- Hydro-Québec, list of heat pumps eligible for LogisVert (owner, existing home), amounts re-read Oct. 26, 2026.
- Samsung,
AC048FCUPCG +HC60MBC021H1 system submittal (05052026) and Hylex coil page, re-read Oct. 26, 2026.
LogisVert amounts are indicative: Hydro-Québec confirms them when you apply. Prices on quote.
Our Samsung add-on central systems, right below.
Hylex Standard and Premium with an HC coil, 2 to 5 tons.