Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
Your electric furnace, replaced by a Samsung Hylex central heat pump.
Our Samsung “electric furnaces” are complete Hylex systems: the multi-position air handler (HH series), which takes the place of the electric furnace, with its outdoor unit. Same AHRI numbers as our central heat pumps. Heating down to -25 °C, optional 5 to 20 kW heat kits, LogisVert from $1,980 to $4,680 with the Premium.

Optional Samsung heat kits for the HH unit, for the coldest days.
Samsung Hylex multi-position air handler spec sheet (2026).
Premium or Standard, 2 to 5 tons.
Pick your options to see the models, the AHRI number, the heat at -8 °C, the LogisVert amount when there is one, and what to plan for.
Capacity is worked out during the visit, from the house and your ducts. Samsung recommends a two-stage thermostat.

Hylex Premium · electric furnace 2 tons
HH24MABC11H1 + AC024FCUPCG · AHRI 218158146
Indicative LogisVert (Hydro-Québec), $120 / 1,000 BTU/h at -8 °C
Plan for: the

Hylex Premium · electric furnace 3 tons
HH36MACC11H1 + AC036FCUPCG · AHRI 218158147
Indicative LogisVert (Hydro-Québec), $120 / 1,000 BTU/h at -8 °C
Plan for: the

Hylex Premium · electric furnace 4 tons
HH60MBCC11H1 + AC048FCUPCG · AHRI 218158148
Indicative LogisVert (Hydro-Québec), $120 / 1,000 BTU/h at -8 °C
Plan for: the

Hylex Premium · electric furnace 5 tons
HH60MACC11H1 + AC060FCUPCG · AHRI 218158149
Indicative LogisVert (Hydro-Québec), $120 / 1,000 BTU/h at -8 °C
Plan for: the

Hylex Standard · electric furnace 2 tons
HH24MCAC11H1 + AC024FCUDCG · AHRI 218158142
Not ENERGY STAR certified with the Samsung indoor unit: no LogisVert aid.
Plan for: the

Hylex Standard · electric furnace 3 tons
HH36MCBC11H1 + AC036FCUDCG · AHRI 218158143
Not ENERGY STAR certified with the Samsung indoor unit: no LogisVert aid.
Plan for: the

Hylex Standard · electric furnace 4 tons
HH48MCCC11H1 + AC048FCUDCG · AHRI 218158144
Not ENERGY STAR certified with the Samsung indoor unit: no LogisVert aid.
Plan for: the

Hylex Standard · electric furnace 5 tons
HH60MBCC11H1 + AC060FCUDCG · AHRI 218158145
Not ENERGY STAR certified with the Samsung indoor unit: no LogisVert aid.
Plan for: the
Two ways to install a Hylex.
Replacing an electric furnace? The HH unit takes its place. Keeping your furnace? We add a coil to it.
The Hylex multi-position indoor unit (HH series) takes the place of an electric furnace and uses your ducts. Built-in
A Hylex cased A-coil (HC series) goes on the furnace you keep. The heat pump heats and cools; the furnace takes over when needed. We do not touch the burner or the gas or oil supply.
Which heat kit fits which unit?
The Hylex HH unit can take an optional electric heat kit for backup. The sizes allowed change with the model: pick your Hylex, then a kit.
Greyed-out sizes are not listed in Samsung’s submittal for the selected HH unit.
that is — of electric heat
For 15 and 20 kW, Samsung offers the
On 24,000 BTU/h units like this one, Samsung rules out the 10 kW kit in the downflow position.
Without a kit, the HH unit has no built-in backup: we look at how to cover the coldest days during the visit.
Source: Samsung Hylex submittals with HH unit (04072026), accessories p. 5; manual 679608-01 (10 kW downflow restriction). Brochure 02.2026-V2 lists 7.5 kW for
What Samsung requires around the Hylex.
Nothing hidden: these parts are in the quote when your install needs them.
Required by Samsung, even with its own indoor unit, and sold separately. We include it in the quote.
Hylex works with a standard 24 V thermostat. Samsung recommends a two-stage thermostat.
In a central install, on the HH unit: 5 to 20 kW depending on the model (up to 10 kW on 2-ton units, 15 kW on 3-ton units). For 15 and 20 kW, Samsung offers the
Required with an HC coil (add-on), per Samsung: HA00A00203H1. The HH unit already has its own.
If refrigerant leaks, here is what the unit does.
Illustration. Source: Samsung HH unit installation manual (679608-01, March 2026). Class A2L: burning velocity of 10 cm/s or less (ASHRAE 34). Per UL, mitigation must start within 15 seconds, at 25% of the lower flammability limit.
From $1,980 to $4,680 with the Premium.
The same amount as the Hylex central: it is the same system, with the same AHRI number. With Samsung indoor units, the Standard is not ENERGY STAR certified. Pick a system to see the math.
HH60MACC11H1 + AC060FCUPCG · AHRI 218158149
HH60MBCC11H1 + AC048FCUPCG · AHRI 218158148
HH36MACC11H1 + AC036FCUPCG · AHRI 218158147
HH24MABC11H1 + AC024FCUPCG · AHRI 218158146
HH36MCBC11H1 + AC036FCUDCG · AHRI 218158143
Not ENERGY STAR certified with the Samsung indoor unit: no LogisVert aid.
July 8, 2027
For installations completed on or after November 26, 2025, the unit must be ENERGY STAR certified.
The outdoor unit needs a nominal cooling capacity of at least 12,000 BTU/h.
Apply no later than nine months after installation. The grant never exceeds 100% of the pre-tax cost.
The amount follows the installed combination, outdoor and indoor, as listed under its AHRI number.
Source: Hydro-Québec, residential LogisVert page and Participation Guide v1.10 (Sept. 15, 2026), checked Oct. 8, 2026. Indicative amounts, confirmed by Hydro-Québec when you apply. Our LogisVert guide
The HH unit, model by model.
The unit that takes your electric furnace’s place: size, weight, airflow, filter and kits allowed. Pick your Hylex.
HH24MCAC11H1 · 75 lb
HH36MCBC11H1 · 100 lb
HH48MCCC11H1 · 150 lb
HH60MBCC11H1 · 150 lb
HH24MABC11H1 · 100 lb
HH36MACC11H1 · 150 lb
HH60MBCC11H1 · 150 lb
HH60MACC11H1 · 150 lb
Sources: Samsung Hylex submittals with HH unit (04072026); manual 679608-01. Dimensions W × H × D.
By range and by install.

Hylex Premium
ENERGY STAR cold climate, LogisVert $1,980 to $4,680.
See the collection
Hylex Standard
Same

“Add-on” central systems
A Hylex coil on the furnace you keep.
See the collection
Electric furnaces
The HH unit in place of the electric furnace.
You are hereYour new Samsung “furnace”, installed by a local team.
Samsung designs the unit. AirGreen picks it with you, installs it and registers it.
What SAMSUNG brings
- Hylex
R-454B A central heat pump onR-454B refrigerant, 2 to 5 tons. - Down to -25 °CFor the whole range, per the Samsung spec sheets.
- Two installsWith its air handler, or on your furnace.
- 24 V thermostatA standard thermostat, ideally two-stage.
What AirGreen brings
- Sold and installed by AirGreenThe visit, the quote, the installation and start-up.
- Free home estimateWe pick the range and tonnage with you, on site.
- Warranty registered for youWe register your unit with Samsung.
- RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16.
Up to 10 years on compressor and parts, if the unit is registered on time.
Samsung states up to 10 years on the compressor and parts, registration required within 60 days, conditions apply. We do the registration for you.
compressor and parts, unit registered within 60 days of installation
Without registration within 60 days, the extended warranty does not apply. The base warranty term depends on the product: we confirm it in writing in your quote.
Samsung limited warranty, extended by registration. Labour: see your AirGreen quote.
Samsung’s extended warranty requires registering the unit within 60 days of installation. We do it for you.
Installed by a company holding a Régie du bâtiment du Québec licence.
We look at your ducts, your current electric furnace and the best spot for the outdoor unit.
The range, the size, the AHRI number and the indicative LogisVert amount.
Evacuation, charge adjusted to the line length, heating and cooling tests.
We take care of it for you.
Source: Samsung HVAC 2026 spec sheets and warranty registration page, checked Oct. 8, 2026.
The Hylex HH unit, in six claims.
True or false? Flip the cards.
The Hylex HH unit can touch combustible material.
The 20 kW kit fits every Hylex unit.
The HH unit blower has five speeds.
The filter comes with the unit.
After a leak, the blower runs for 7 more minutes.
A 20 kW electric furnace is about 68,000 BTU/h.
What people ask about the Hylex “furnace”.
Both roles: the HH unit takes the electric furnace’s place in your ducts, and the Hylex outdoor unit does the heat pump work. The optional heat kits serve as backup.
They are the same systems, with the same AHRI numbers. We list them here too for people looking to replace an electric furnace.
In a central install, the Hylex air handler (HH) replaces the electric furnace. In an add-on, a Hylex coil (HC) goes on the furnace you keep, and the furnace takes over when needed.
With the Samsung indoor unit, the Hylex Standard is not ENERGY STAR certified. Since November 26, 2025, Hydro-Québec requires that certification.
A standard 24 V thermostat, ideally two-stage per Samsung. The
Per Samsung’s submittals: 5, 7 or 10 kW on 2-ton units; 5 to 15 kW on 3-ton units; 5 to 20 kW on the 4-ton Standard; 7 to 20 kW on the 5-ton Standard and the 4- and 5-ton Premium. They are optional.
Down to -25 °C (-13 °F) for the whole range. Premium 2 and 3 tons keep 100% of rated capacity down to -20 °C; the others down to -10 °C, per the Samsung spec sheets (except Standard 5 tons, not stated).
In a central install, Samsung offers 5 to 20 kW heat kits for the HH unit. In an add-on, your furnace takes over. We discuss it during the visit.
The HH unit has its own leak detector and mitigation control. With an HC coil, Samsung requires the HA00A00203H1 mitigation controller.
No. In an add-on, we install the coil on the furnace and the heat pump outside; we do not touch the burner or the gas or oil supply.
Up to 10 years on compressor and parts if the system is registered with Samsung within 60 days. Conditions apply. We register it for you.
Hydro-Québec excludes indoor units and ducts installed outside the insulation envelope, for example in the attic or roof space. We look at your duct route during the visit.
No question matches. Call us: 514 316-2973.
The rest of the Samsung range at AirGreen.

SAMSUNG wall-mounted heat pumps
WindFree Standard and Max Heat, 9,000 to 24,000 BTU/h.
See the collection
2, 3 or 4-head multi-zone
FJM Premium: up to 4 rooms on one outdoor unit.
See the collection
SAMSUNG ducted units
Slim duct hidden in a ceiling or closet.
See the collection
SAMSUNG ceiling cassettes
WindFree mini 4-way cassette, 2 × 2 ft.
See the collection
SAMSUNG floor consoles
Low on the wall, often under a window.
See the collection
SAMSUNG thermostats and Wi-Fi
Wired controllers and Wi-Fi adapter.
See the collectionYour old electric furnace replaced by a Hylex, installed by AirGreen.
We look at your ducts, your current electric furnace and the right spot outside. Then a clear quote: range, tonnage, AHRI number, parts to plan for and indicative LogisVert amount.
Hydro-Québec does no phone or door-to-door solicitation for LogisVert. A call “from Hydro-Québec” selling a heat pump? Hang up.


Sources checked on October 8, 2026
- Samsung HVAC Hylex
R-454B spec sheets (2026), Hylex brochure (HYLEXBR 02.2026-V2) andMXD-U001XN control unit installation manual. - ENERGY STAR, Certified Air-Source Heat Pumps (dataset w7cv-9xjt), queried by AHRI number on Oct. 8, 2026.
- Hydro-Québec, residential LogisVert page and LogisVert Participation Guide v1.10 (Sept. 15, 2026), checked Oct. 8, 2026.
- Samsung HVAC 2026 spec sheets and warranty registration page (samsunghvac.com), checked Oct. 8, 2026.
- airgreen.ca product pages, Oct. 8, 2026.
- Samsung Hylex
R-454B submittals (outdoor units 02112026, HH air handler systems 04072026, HC coil 05052026), installation manualsDB68-13654A (outdoor),DB68-13653A (MXD-U001XN ) and 679608-01 (HH air handler), brochure HYLEXBR 02.2026-V2. - UL Solutions, “Inspecting Refrigerant Detection Systems in HVAC Equipment”, 2024; ASHRAE 34, Addendum ak (class 2L).
- Natural Resources Canada, “Heating and cooling with a heat pump” (1 ton = 3.5 kW = 12,000 BTU/h); NIST SP 811 (conversions); ACCA, “A Little History Behind Tons” (2015).
LogisVert amounts are indicative: Hydro-Québec confirms them when you apply. Prices on quote.
Our Samsung electric furnaces, right below.
Hylex Standard and Premium, 2 to 5 tons, with the HH air handler.