Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
Your electric furnace, replaced by a Samsung Hylex central heat pump.
Our Samsung “electric furnaces” are complete Hylex systems: the multi-position air handler (HH series), which takes the place of the electric furnace, with its outdoor unit. Same AHRI numbers as our central heat pumps. Heating down to -25 °C, optional 5 to 20 kW heat kits, LogisVert from $1,980 to $4,680 with the Premium.
- Cabinets 15, 18 1/2 or 21 7/8 in wide
- Detector and mitigation built in
- 5-speed ECM blower
Optional Samsung heat kits for the HH unit, for the coldest days.
Samsung submittals with HH unit (04072026).
Which Hylex replaces your electric furnace?
Pick your options to see the models, the AHRI number, the heat at -8 °C, the LogisVert amount when there is one, and what to plan for.
Capacity is worked out during the visit, from the house and your ducts. Samsung recommends a two-stage thermostat.
For all: heating down to -25 °C per Samsung;

Hylex Premium · electric furnace 2 tons
HH24MABC11H1 + AC024FCUPCG · AHRI 218158146
Amount on Hydro-Québec’s LogisVert list (Oct. 26, 2026), $120 / 1,000 BTU/h at -8 °C

Hylex Premium · electric furnace 3 tons
HH36MACC11H1 + AC036FCUPCG · AHRI 218158147
Amount on Hydro-Québec’s LogisVert list (Oct. 26, 2026), $120 / 1,000 BTU/h at -8 °C

Hylex Premium · electric furnace 4 tons
HH60MBCC11H1 + AC048FCUPCG · AHRI 218158148
Amount on Hydro-Québec’s LogisVert list (Oct. 26, 2026), $120 / 1,000 BTU/h at -8 °C

Hylex Premium · electric furnace 5 tons
HH60MACC11H1 + AC060FCUPCG · AHRI 218158149
Amount on Hydro-Québec’s LogisVert list (Oct. 26, 2026), $120 / 1,000 BTU/h at -8 °C

Hylex Standard · electric furnace 2 tons
HH24MCAC11H1 + AC024FCUDCG · AHRI 218158142
Not ENERGY STAR certified with the Samsung indoor unit: no LogisVert aid.

Hylex Standard · electric furnace 3 tons
HH36MCBC11H1 + AC036FCUDCG · AHRI 218158143
Not ENERGY STAR certified with the Samsung indoor unit: no LogisVert aid.

Hylex Standard · electric furnace 4 tons
HH48MCCC11H1 + AC048FCUDCG · AHRI 218158144
Not ENERGY STAR certified with the Samsung indoor unit: no LogisVert aid.

Hylex Standard · electric furnace 5 tons
HH60MBCC11H1 + AC060FCUDCG · AHRI 218158145
Not ENERGY STAR certified with the Samsung indoor unit: no LogisVert aid.
Electric furnace: the HH unit takes its place.
The Hylex air handler takes the electric furnace’s place, on your ducts. If you need backup heat, the heat kit installs inside the HH unit.
Three cabinet widths: 15 in · 18 1/2 in · 21 7/8 in.
A gas, oil or propane furnace? It can stay: see the add-on.
Upflow, downflow or horizontal: where does your HH unit go?
Your electric furnace blew one way. The HH unit can blow four ways, each with its own rules. Turn it.
Upflow
Air comes in at the bottom and out the top. The unit is supported from below only, on a solid floor or a field-built frame, per Samsung. It can also go in a closet whose false floor serves as the return plenum.
Downflow
It takes Samsung’s downflow conversion kit (by cabinet width: ), and the fan moves to speed 5.
On 24,000 BTU/h units, no 10 kW heat kit with the downflow kit, per Samsung.
Horizontal, left
The unit lies on its side, air goes out to the left. Samsung calls for a 1/2 in pitch toward the drain.
Horizontal, right
Air goes out to the right. This way, the drain pan has to move, per Samsung. Same 1/2 in pitch toward the drain.
Over a finished room, Samsung requires a secondary pan, drained to the outside.
Samsung calls for an auxiliary pan in an attic or above a finished ceiling. And Hydro-Québec excludes from LogisVert any indoor unit or ducts outside the insulation envelope, such as in the attic.
Samsung’s manual says some models ship upflow-only, without naming them. The submittals give all four positions to every HH unit. We confirm the position with your unit’s rating plate.
A curious fact: three HH widths, three downflow kits.
Source: Samsung HH unit installation manual (679608-01, April 2026), re-read Oct. 26, 2026: support, closet, speed 5, pitch, right-hand pan, secondary and auxiliary pans, upflow-only models; submittals with HH unit (04072026): positions and kits; brochure HYLEXBR 02.2026-V2: 10 kW in downflow; Hydro-Québec LogisVert guide v1.10: insulation envelope.
Which heat kit fits which unit?
The Hylex HH unit can take an optional electric heat kit for backup. The sizes allowed change with the model: pick your Hylex, then a kit.
Samsung makes five kits, 5 to 20 kW. Greyed-out sizes are not listed in Samsung’s submittal for the selected HH unit.
that is — of electric heat
For 15 and 20 kW, Samsung offers the
On 24,000 BTU/h units like this one, Samsung rules out the 10 kW kit in the downflow position.
Without a kit, the HH unit has no built-in backup: we look at how to cover the coldest days during the visit.
Source: Samsung Hylex submittals with HH unit (04072026), accessories p. 5, re-read Oct. 26, 2026; manual 679608-01 (10 kW downflow restriction). Brochure 02.2026-V2 lists 7.5 kW for
During defrost, the fan stops. Here’s why.
In cold weather, the outdoor unit sometimes has to defrost. Samsung built in fan settings so you don’t feel cold air. Watch one cycle.
Cold-air prevention option: the coil warms up before the fan starts.Option off: the fan starts right away, with the coil still cold.
The fan turns, warm air rises in the ducts.
The outdoor unit defrosts. The fan stops so it doesn’t blow cold air and, per Samsung, to reduce the need for heat kits.
The fan restarts after a delay. Samsung provides adjustable delays for defrost and cold-air prevention.
A curious fact: Samsung says it outright. Stopping the fan during defrost is there to “reduce the need of electric heat kits”. Illustration: Samsung doesn’t publish defrost length or frequency in the documents we checked. The control unit manual also says the fan stop is disabled if low pressure drops to 14 psi or lower during defrost.
Source: Samsung,
Your HH unit’s airflow, by duct resistance.
Samsung publishes each HH unit’s airflow by duct resistance, from 0.1 to 1.0 in of water column. Slide the resistance: the airflow follows Samsung’s table.
Speed 3, factory setting, dry coil, filter in place. Samsung allows other speeds. The table is shown as printed, quirks included (586 then 588 CFM on the
Source: Samsung HH unit manual (679608-01), Table 1, re-read Oct. 26, 2026; submittals with HH unit (04072026), p. 3: 0.30 in rated, 0.1 to 1.0 in range. Conversion: 1 in of water = 249.09 Pa (NIST SP 811).
With the HH unit: the ACU, a filter, and a heat kit if needed.
The leak detector is already inside the HH unit. Plan for: the
Required by Samsung on every Hylex, even with its own indoor unit, and sold separately. We include it in the quote.
12 × 20, 16 × 20 or 18 × 25 in depending on the model. Samsung requires a filter listed as a “Class 2 furnace air filter”.
5 to 20 kW, fed by 1 or 2 circuits depending on the kit. For 15 and 20 kW, the
Built into the HH unit with its mitigation: no
If refrigerant leaks, here is what the unit does.
Illustration. Source: Samsung HH unit installation manual (679608-01, March 2026), re-read Oct. 26, 2026. Class A2L: burning velocity of 10 cm/s or less (ASHRAE 34). Per UL, mitigation must start within 15 seconds, at 25% of the lower flammability limit.
R-454B charge and minimum floor area: where does your Hylex sit?
The HH manual ties the refrigerant charge to a minimum conditioned area. Pick your Hylex: we do the math with Samsung’s table.
proportionalnext table row up
| Area | m² | |
|---|---|---|
| 3 lb | 45 sq ft | 4.2 m² |
| 5 lb | 75 sq ft | 7.0 m² |
| 10 lb | 150 sq ft | 13.9 m² |
| 15 lb | 225 sq ft | 20.9 m² |
| 20 lb | 300 sq ft | 27.9 m² |
| 25 lb | 375 sq ft | 34.8 m² |
| 30 lb | 450 sq ft | 41.8 m² |
It’s a manufacturer safety rule for
Source: Samsung HH unit manual (679608-01), p. 5, re-read Oct. 26, 2026; outdoor unit submittals (02112026): factory and maximum charges; manual
With the HH unit, $1,980 to $4,680 in Premium.
The same amount as the Hylex central: it is the same system, with the same AHRI number. With Samsung indoor units, the Standard is not ENERGY STAR certified. Pick a system to see the math.
HH60MACC11H1 + AC060FCUPCG · AHRI 218158149
HH60MBCC11H1 + AC048FCUPCG · AHRI 218158148
HH36MACC11H1 + AC036FCUPCG · AHRI 218158147
HH24MABC11H1 + AC024FCUPCG · AHRI 218158146
HH36MCBC11H1 + AC036FCUDCG · AHRI 218158143
Not ENERGY STAR certified with the Samsung indoor unit: no LogisVert aid.
July 8, 2027
Source: Hydro-Québec, list of heat pumps eligible for LogisVert (owner, existing home), amounts re-read Oct. 26, 2026, by AHRI number; Participation guide v1.10 (Sept. 15, 2026). Hydro-Québec’s list prevails; the final amount is confirmed when you apply. The program rules are explained once, on the Samsung page. Our LogisVert guide
The HH unit, system by system.
The unit that takes your electric furnace’s place: size, weight, airflow, filter and kits allowed. Pick your Hylex.
HH24MCAC11H1 · 75 lb
HH36MCBC11H1 · 100 lb
HH48MCCC11H1 · 150 lb
HH60MBCC11H1 · 150 lb
HH24MABC11H1 · 100 lb
HH36MACC11H1 · 150 lb
HH60MBCC11H1 · 150 lb
HH60MACC11H1 · 150 lb
Sources: Samsung Hylex submittals with HH unit (04072026), re-read Oct. 26, 2026; manual 679608-01. Dimensions W × H × D.
The seven HH units, side by side.
Samsung makes seven HH units for the Hylex. Here is what Samsung publishes for each, in its own terms, and what it doesn’t.
| HH unit | |||||||
|---|---|---|---|---|---|---|---|
| Identification | |||||||
| Our systemspairing | Standard 2 t | Premium 2 t | Standard 3 t | Premium 3 t | Standard 4 t | Premium 4 t Standard 5 t | Premium 5 t |
| System AHRI numberAHRI Certified Ref. No. | 218158142* | 218158146 | 218158143 | 218158147 | 218158144 | 218158148 218158145 | 218158149 |
| ENERGY STAR recordpd_id | not published | 4576541 | not published | 4576540 | not published | 4576539 | 4576538 |
| System LogisVertHydro-Québec list | none | $1,980 | none | $2,520 | none | $3,696 (Premium 4 t) none (Standard 5 t) | $4,680 |
| Cabinet | |||||||
| W × H × DDimensions (in.) | 15 × 36 × 22 in | 18 1/2 × 41 × 22 in | 18 1/2 × 41 × 22 in | 21 7/8 × 48 × 26 in | 21 7/8 × 48 × 26 in | 21 7/8 × 48 × 26 in | 21 7/8 × 48 × 26 in |
| WeightWeight (lbs.) | 75 lb | 100 lb | 100 lb | 150 lb | 150 lb | 150 lb | 150 lb |
| Filter, field-providedFilter (in.) | 12 × 20 in | 16 × 20 in | 16 × 20 in | 18 × 25 in | 18 × 25 in | 18 × 25 in | 18 × 25 in |
| Downflow kitDownflow Kit | |||||||
| Air and power | |||||||
| Airflow low / mid / highAirflow (CFM) | 613 / 670 / 809 CFM | 686 / 739 / 902 CFM | 786 / 1,028 / 1,297 CFM | 946 / 1,104 / 1,345 CFM | 1,189 / 1,712 / 1,971 CFM | 1,316 / 1,793 / 2,071 CFM | 1,337 / 1,817 / 2,102 CFM |
| Static pressureStandard / Min. / Max. (“WC) | 0.30 · 0.1 to 1.0 in | 0.30 · 0.1 to 1.0 in | 0.30 · 0.1 to 1.0 in | 0.30 · 0.1 to 1.0 in | 0.30 · 0.1 to 1.0 in | 0.30 · 0.1 to 1.0 in | 0.30 · 0.1 to 1.0 in |
| MotorECM | 5-speed ECM | 5-speed ECM | 5-speed ECM | 5-speed ECM | 5-speed ECM | 5-speed ECM | 5-speed ECM |
| MCA 208 / 240 VMCA (A) | 4 / 3.8 A | 4 / 3.8 A | 4 / 3.8 A | 4 / 3.8 A | 4.2 / 4 A | 6.1 / 5.8 A | 6.1 / 5.8 A |
| Max. breakerIndoor Max. Breaker Amps | 15 A | 15 A | 15 A | 15 A | 15 A | 15 A | 15 A |
| Heat kits allowedElectric Heat Kits | 5 · 7 · 10 kW | 5 · 7 · 10 kW | 5 · 7 · 10 · 15 kW | 5 · 7 · 10 · 15 kW | 5 · 7 · 10 · 15 · 20 kW | 7 · 10 · 15 · 20 kW | 7 · 10 · 15 · 20 kW |
| SoundSound | not published | not published | not published | not published | not published | not published | not published |
- The HH unit’s sound level: the submittals say “TBD”.
- Current draw (MCA and protection) with a heat kit installed: the manual refers to the rating plate.
- Which models ship upflow-only.
* Number found only in our store data: no NEEP or ENERGY STAR record. Sources: Samsung submittals with HH unit (04072026), re-read Oct. 26, 2026; manual 679608-01; ENERGY STAR, re-read Oct. 26, 2026; Hydro-Québec’s LogisVert list. One combination at a time: the amounts don’t add up.
Keeping a fuel-burning furnace? See the add-on.
Gas, oil or propane: the furnace can stay, and an HC coil goes on it.

Hylex Premium
Premium with the HH unit: $1,980 to $4,680.
See the collection
Hylex Standard
Standard: a 15 in wide HH unit at 2 t.
See the collection
“Add-on” central systems
A fuel-burning furnace? It can stay.
See the collection
Electric furnaces
You are here: the HH unit in place of the electric furnace.
You are hereSamsung makes the HH unit. We install it where the furnace was.
Samsung designs the air handler, its detector and its heat kits. Sold and installed by AirGreen: the install, the duct connection and start-up.
What SAMSUNG brings
- 3 cabinet widths15, 18 1/2 and 21 7/8 in.
- 4 positionsDownflow included, with a kit.
- 5-speed ECM motorFor the blower, per Samsung.
- Built-in detector
R-454B detector and mitigation.
What AirGreen brings
- Sold and installed by AirGreenThe visit, the quote, the installation and start-up.
- Free home estimateWe pick the range and tonnage with you, on site.
- 12-12-6 warranty12 years compressor, 12 years parts, 6 years labour.
- RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16.
These apply to every Hylex: they have their own page, so we don’t repeat them here.
The Hylex HH unit, in six claims.
True or false? Flip the cards.
The Hylex HH unit can touch combustible material.
The 20 kW kit fits every Hylex unit.
The HH unit blower has five speeds.
The filter comes with the unit.
After a leak, the blower runs for 7 more minutes.
A 20 kW heat kit is about 68,000 BTU/h of heat.
What people ask about the Hylex “furnace”.
A heat pump. The HH unit takes the electric furnace’s place on your ducts, and the Hylex outdoor unit does the heat-pump work. Without a heat kit, the HH unit has no electric resistance heat.
A field-supplied filter: 12 × 20, 16 × 20 or 18 × 25 in depending on the model. Samsung requires a filter listed as a “Class 2 furnace air filter”.
Per Samsung’s submittals: 5, 7 or 10 kW on the 2-ton units; 5 to 15 kW at 3 tons; 5 to 20 kW on the Standard 4-ton; 7 to 20 kW on the Standard 5-ton and the Premium 4- and 5-ton.
They are the same systems, with the same AHRI numbers. We show them here too for people looking to replace an electric furnace.
Yes, per Samsung, on a false floor that serves as the return plenum. Keep 24 in clear in front for service.
No question matches. Call us: 514 316-2973.
Baseboards in some rooms? The ductless range.
The rest of the Samsung range at AirGreen, sold and installed by us.

SAMSUNG wall-mounted heat pumps
WindFree Standard and Max Heat, 9,000 to 24,000 BTU/h.
See the collection
2, 3 or 4-head multi-zone
FJM Premium: up to 4 rooms on one outdoor unit.
See the collection
SAMSUNG ducted units
Slim duct hidden in a ceiling or closet.
See the collection
SAMSUNG ceiling cassettes
WindFree mini 4-way cassette, 2 × 2 ft.
See the collection
SAMSUNG floor consoles
Low on the wall, often under a window.
See the collection
SAMSUNG thermostats and Wi-Fi
Wired controllers and Wi-Fi adapter.
See the collectionYour old electric furnace replaced by a Hylex, installed by AirGreen.
We look at your ducts, your current electric furnace and the right spot outside. Then a clear quote: range, tonnage, AHRI number, parts to plan for and indicative LogisVert amount.
Hydro-Québec does no phone or door-to-door solicitation for LogisVert. A call “from Hydro-Québec” selling a heat pump? Hang up.


Sources checked on October 26, 2026
- Samsung HVAC Hylex
R-454B spec sheets (2026), Hylex brochure (HYLEXBR 02.2026-V2) andMXD-U001XN control unit installation manual. - ENERGY STAR, Certified Air-Source Heat Pumps (dataset w7cv-9xjt), queried by AHRI number on Oct. 8, 2026, re-read Oct. 26, 2026.
- Hydro-Québec, residential LogisVert page and LogisVert Participation Guide v1.10 (Sept. 15, 2026), checked Oct. 8, 2026.
- Samsung HVAC 2026 spec sheets (samsunghvac.com), checked Oct. 8, 2026.
- Samsung Hylex
R-454B submittals (outdoor units 02112026, HH air handler systems 04072026, HC coil 05052026), installation manualsDB68-13654A (outdoor),DB68-13653A (MXD-U001XN ) and 679608-01 (HH air handler), brochure HYLEXBR 02.2026-V2. - UL Solutions, “Inspecting Refrigerant Detection Systems in HVAC Equipment”, 2024; ASHRAE 34, Addendum ak (class 2L).
- Natural Resources Canada, “Heating and cooling with a heat pump” (1 ton = 3.5 kW = 12,000 BTU/h); ASHRAE Terminology, “ton of refrigeration”; NBS 1913 bulletin (143.5 BTU per pound of ice); NIST SP 811 (conversions).
- ENERGY STAR, Certified Air-Source Heat Pumps (dataset w7cv-9xjt), Hylex records by AHRI number, re-read Oct. 26, 2026.
- Hydro-Québec, list of heat pumps eligible for LogisVert (owner, existing home), amounts re-read Oct. 26, 2026.
- Samsung Hylex
R-454B submittals: eight outdoor units (02112026) and eight systems with the HH air handler (04072026), re-read Oct. 26, 2026. - Samsung HH unit installation manual 679608-01 (April 2026), re-read Oct. 26, 2026: positions, airflow (Table 1), minimum area (p. 5); National Building Code of Canada 2020, Table
C-2 .
LogisVert amounts are indicative: Hydro-Québec confirms them when you apply. Prices on quote.
Our Samsung electric furnaces, right below.
Hylex Standard and Premium, 2 to 5 tons, with the HH air handler.