The WindFree mini cassette: one ceiling tile, no drafts.
It takes the place of one 2 × 2 ft tile in a drop ceiling 2.5 m up or more, per Samsung. Its panel holds the display, the Wi-Fi and a humidity sensor; in cooling, WindFree mode blows at under 0.15 m/s. The best SEER2 of Samsung’s three CAC formats, at every size. LogisVert: $1,284 (12,000) and $1,872 (18,000).
- One 2 × 2 ft tile
- One panel for all three sizes
- Built-in leak detection
One drop-ceiling tile: panel 24 3/8 in (620 mm) square, body 9 13/16 in tall, per Samsung.
Samsung WindFree Mini 4-Way Cassette submittals (versions 10072024A and 02132025A).
The 9,000 delivers 9,700 BTU/h at -8 °C, yet no LogisVert.
For Hydro-Québec, what counts first is cooling: 12,000 BTU/h minimum. The 9,000 falls short, even though it heats well. Pick a size: models, AHRI number, certified heat and the math.

Not sure about the size? We work it out on site: insulation, windows, orientation, ceiling height.

WindFree mini cassette · 9,000 BTU/h
AC009DNNDCG + AC009DXSCCG · AHRI 216441725
Under 12,000 BTU/h: below the LogisVert minimum.
At -25 °C, the coldest point listed on NEEP: up to 6,400 BTU/h for it, at a COP of 1.75.

WindFree mini cassette · 12,000 BTU/h
AC012DNNDCG + AC012DXSCCG · AHRI 216441747
Amount on Hydro-Québec’s LogisVert list (Oct. 26, 2026), $120 / 1,000 BTU/h at -8 °C
At -25 °C, the coldest point listed on NEEP: up to 7,000 BTU/h for it, at a COP of 1.92.

WindFree mini cassette · 18,000 BTU/h
AC018DNNDCG + AC018DXSCCG · AHRI 215220729
Amount on Hydro-Québec’s LogisVert list (Oct. 26, 2026), $120 / 1,000 BTU/h at -8 °C
At -25 °C, the coldest point listed on NEEP: up to 15,400 BTU/h for it, at a COP of 1.67.
One tile, four directions, and the best SEER2 of the three.
Designed for a standard drop-ceiling grid, without getting in the way of the tiles next to it, per Samsung. 620 mm (24 3/8 in) square panel.
22.00 on the 9,000 and 12,000, per ENERGY STAR: the highest of Samsung’s three CAC Premium units.
Air leaves all four sides of the panel: a good option in the middle of an open room or a shop.
In cooling, air leaves at under 0.15 m/s in WindFree mode, per Samsung. The mode is not used in heating.
One tile, a 580 mm opening, and 2.5 m to the ceiling.
As a rule, Samsung doesn’t allow the mini cassette less than 2.5 m above the floor. Slide to your ceiling height, then follow the install, from tile to panel.
Above 1.836 kg of
A knock-out takes outside air, with a booster fan, per Samsung. A duct to another room does not apply to WindFree models.
The manual rules out a ship or a vehicle, such as a campervan.
Pattern sheet, drain hose, insulation, reducer, clamp and ties: the control is sold separately.
Source: Samsung installation manual
One panel, the PC4SUFMUNW , for all three sizes.
Everything you see of the cassette sits in its 620 mm square panel. Tap the dots.
Display and receiver
The panel carries the LED display and the infrared receiver for the remote, per the submittal. Samsung sells the remote separately.
“Fascia panel shall have LED display, infrared receiver, and motorized louvers”Wi-Fi
The submittal puts the Wi-Fi adapter in the panel, for the SmartThings app. Samsung’s web page, though, mentions an adapter sold separately: we confirm it in your quote.
“The indoor unit fascia panel shall have a built-in Wi-Fi adapter as standard”Humidity sensor
The WindFree panel has a humidity sensor: when the air is very humid, it holds WindFree mode back to prevent condensation.
“The WindFree™* fascia panel includes a humidity sensor to prevent condensation”Four motorized louvers
Each louver is set on its own, at the same angle as the others or not, between 32° and 65°.
“the four louver blades can be individually set at the same or different angles within a 32-65° range”Washable filter
Washable filter as standard, behind the grille. The reminder is set to 1,000 or 2,000 hours.
“Washable filter as standard”Occupancy sensor, optional
Samsung offers the MCR-SMDU sensor, sold separately: it turns the cassette off or changes its set point when the room empties.
“Use of MDS is optional (sensor sold separately).”Tap a number: each point shows what Samsung says about it.
Source: Mini 4-Way submittals (
Set the blades one by one. Or switch to WindFree.
The mini cassette blows in four directions, and each blade has its own angle. Switch to WindFree, in cooling: air then comes through the panel’s micro-holes.
Samsung: four outlets, with blades set one by one, at the same or different angles, between 32° and 65°. In WindFree mode, offered in cooling only, the blades close and air comes through thousands of micro-holes in the panel, at under 0.15 m/s.
Source: samsunghvac.com, WindFree Mini 4-Way Cassette page (32-65° blades, cooling only); submittal 02132025A (thousands of micro-holes, 0.15 m/s). Arrow length: illustration, not a measured throw.
Very humid air: the cassette holds WindFree back.
In WindFree mode, the louvers close and air seeps out through the micro-holes. When the air is very humid, a sensor in the panel limits that mode to prevent condensation, per Samsung. Pick the mode and the weather.
Louvers closed: air seeps out through thousands of micro-holes in the panel, under 0.15 m/s.
The panel’s humidity sensor limits WindFree mode to prevent condensation. Samsung does not publish the humidity threshold.
In heating, the cassette blows through its open louvers: WindFree mode exists in cooling only, per Samsung.
Did you know: below 0.15 m/s, air counts as “still air” under ASHRAE 55-2013, Samsung notes. With its humidity sensor, the cassette also sets its coil temperature by the dew point, the Samsung submittal says.
Source: Samsung WindFree Mini 4-Way Cassette page: “WindFree™* operation is available in cooling mode only”, panel humidity sensor that restricts WindFree in high humidity, 0.15 m/s and ASHRAE 55-2013; submittal 02132025A (louvers closed, thousands of micro-holes; coil set by the dew point). Humidity threshold: not published by Samsung.
Nobody in the room? With its sensor, the cassette knows.
Samsung offers an occupancy sensor for the mini cassette, the MCR-SMDU, sold separately. Depending on who’s there, it turns the unit off or changes its set point. Watch a day go by, or tap an hour.
Per Samsung, the sensor also learns your occupancy patterns, to cut run time between occupied and unoccupied periods.
Did you know: of Samsung’s three CAC Premium units, only the mini cassette has an occupancy sensor in its accessory list. Samsung publishes neither its range, its delay nor the set-point change.
Source: Samsung WindFree Mini 4-Way Cassette page: the “Motion Detection Sensor (MDS)” turns the unit off or changes its set point by occupancy and learns occupancy patterns; “Use of MDS is optional (sensor sold separately)”; submittal 02132025A (MCR-SMDU); Slim Duct and Console submittals (no occupancy sensor in their accessories). Schedule: made-up example.
Up to $1,872, checked by AHRI number.
ENERGY STAR cold-climate certified: $120 per 1,000 BTU/h of heat at -8 °C, from 12,000 BTU/h. Pick a size to see the math, or the reason when there is no amount.
AC018DNNDCG + AC018DXSCCG · AHRI 215220729
AC012DNNDCG + AC012DXSCCG · AHRI 216441747
AC009DNNDCG + AC009DXSCCG · AHRI 216441725
Under 12,000 BTU/h: below the LogisVert minimum.
July 8, 2027
For installations completed on or after November 26, 2025, the unit must be ENERGY STAR certified.
The outdoor unit needs a nominal cooling capacity of at least 12,000 BTU/h.
Apply no later than nine months after installation. The grant never exceeds 100% of the pre-tax cost.
The amount follows the installed combination, outdoor and indoor, as listed under its AHRI number.
Source: Hydro-Québec, list of heat pumps eligible for LogisVert (owner, existing home), by AHRI number, re-read Oct. 26, 2026; Participation guide v1.10 (Sept. 15, 2026). Hydro-Québec’s list prevails; the final amount is confirmed when you apply. Our LogisVert guide
The mini cassette, size by size.
Body, panel, sound, airflow and line limits: Samsung’s numbers. Pick a size.
Outdoor unit · 67.2 lb
Indoor body · 25.4 lb + panel 6.0 lb
Sound, with everyday references
Rustling leaves30
Whisper40
Quiet library50
Moderate rain60
Conversation
Scale references: American Academy of Audiology. The unit’s values are those Samsung publishes, in dB(A); the references only give a sense of scale.
Outdoor unit · 67.2 lb
Indoor body · 25.4 lb + panel 6.0 lb
Sound, with everyday references
Rustling leaves30
Whisper40
Quiet library50
Moderate rain60
Conversation
Scale references: American Academy of Audiology. The unit’s values are those Samsung publishes, in dB(A); the references only give a sense of scale.
Outdoor unit · 116.84 lb
Indoor body · 25.4 lb + panel 6.0 lb
Sound, with everyday references
Rustling leaves30
Whisper40
Quiet library50
Moderate rain60
Conversation
Scale references: American Academy of Audiology. The unit’s values are those Samsung publishes, in dB(A); the references only give a sense of scale.
Sources: Samsung Mini 4-Way submittals (10072024A / 02132025A): dimensions, weights, sound, airflow, pump (“maximum 29” lift”), 65 W fan. The 18,000 is rated 17,000 BTU/h in cooling.
The full plate, size by size.
The three WindFree™ Mini 4-Way Cassette sizes side by side, with Samsung’s own term under each row. Where Samsung publishes nothing, the cell says so.
| Size | 9,000 | 12,000 | 18,000 |
|---|---|---|---|
| Identification | |||
| Indoor unitIndoor unit · US Code | |||
| PanelFascia panel | |||
| Outdoor unitOutdoor unit · US Code | |||
| AHRI numberAHRI Certified Ref. No. | 216441725 | 216441747 | 215220729 |
| ENERGY STAR IDENERGY STAR Unique ID | 3891530 | 3891552 | 3621194 |
| LogisVert, Hydro-Québec listre-read Oct. 26, 2026 | not listed | $1,284 | $1,872 |
| Heating | |||
| Rated capacity, cooling / heatingNominal capacity (BTU/h) | 9,000 / 10,000 | 12,000 / 14,000 | 17,000 / 20,000 |
| Heating rangeCapacity range, heating | 2,900 – 15,200 | 3,000 – 16,000 | 3,300 – 23,500 |
| Heat at 8.3 / -8.3 °CENERGY STAR, 47 / 17 °F | 10,000 / 9,700 | 14,000 / 10,700 | 20,000 / 15,600 |
| COP at 8.3 / -8.3 °CNEEP, 47 / 17 °F | 4.31 / 2.47 | 3.80 / 2.61 | 3.20 / 2.31 |
| COP at -15 °CENERGY STAR, 5 °F | 1.80 | 1.80 | 1.80 |
| Coldest point listed on NEEP, -25 °CNEEP, -13 °F | up to 6,400 BTU/h · COP 1.75 | up to 7,000 BTU/h · COP 1.92 | up to 15,400 BTU/h · COP 1.67 |
| Efficiency | |||
| SEER2 / EER2ENERGY STAR | 22.00 / 14.00 | 22.00 / 12.60 | 20.50 / 12.50 |
| HSPF2, region IV / region VSamsung · NEEP | 10.60 / 8.5 | 10.40 / 8.3 | 9.50 / 7.6 |
| Sound | |||
| Indoor, low / mid / highSound pressure, dB(A) | 25 / 28 / 31 | 25 / 30 / 34 | 29 / 34 / 39 |
| Outdoor, high speedCooling / Heating (high), dB(A) | 53 / 53 | 54 / 54 | 58 / 58 |
| Test conditions | not published | not published | not published |
| Air and water | |||
| Airflow, low / mid / highCFM | 212 / 247 / 283 | 226 / 283 / 325 | 300 / 336 / 371 |
| Condensate pumpDrain pump | built in, 29 in lift | built in, 29 in lift | built in, 29 in lift |
| A2L leak detectionA2L Leak Detection | integral | integral | integral |
| Installation | |||
| Power · MCA / MOP208-230 V, 1 ph, 60 Hz | 13.9 A / 15 A | 13.9 A / 15 A | 22.7 A / 25 A |
| Line setLiquid / gas (in) | 1/4 + 3/8 in | 1/4 + 3/8 in | 1/4 + 1/2 in |
| Max length / max riseft | 66 / 49 ft | 66 / 49 ft | 164 / 98 ft |
| Factory charge for 24.6 ft · maximum | 31.7 · 38.4 oz | 31.7 · 38.4 oz | 60.0 · 82.4 oz |
| Outdoor W × H × D · weightin · lb | 31 1/8 × 21 5/8 × 11 3/16 in · 67.2 lb | 31 1/8 × 21 5/8 × 11 3/16 in · 67.2 lb | 34 5/8 × 31 3/8 × 12 3/16 in · 116.84 lb |
| Indoor W × H × D · weightin · lb | 22 5/8 × 9 13/16 × 22 5/8 in · 25.4 lb | 22 5/8 × 9 13/16 × 22 5/8 in · 25.4 lb | 22 5/8 × 9 13/16 × 22 5/8 in · 25.4 lb |
- The humidity level that holds WindFree back.
- The MCR-SMDU sensor’s range, delay and set-point change.
- The fresh-air knock-out’s size and airflow.
- The sound test conditions, and how to read the model numbers.
Sources: Samsung CAC Premium submittals (Slim Duct 02132025A; cassette and console 10072024A and 02132025A); Slim Duct data book Ver. 3.1 and Console data book Ver. 1.1; ENERGY STAR (w7cv-9xjt); NEEP, read by AHRI number on Oct. 14, 2026; Hydro-Québec’s LogisVert list re-read Oct. 26, 2026. HSPF2 region V comes from NEEP: Samsung prints region IV only. The 18,000s are rated under 18,000 BTU/h in cooling: that is their size class, not their rating.
A filter reminder, at 1,000 or 2,000 hours.
The mini cassette reminds you to wash its filter. Pick the setting and your usage: we show how often the reminder comes back.
In deep winter or a heat wave, the unit may run most of the day; in spring, much less. Try it with your season.
about 18 weeks at this pace
Washable filter as standard, per Samsung’s submittal. The reminder is set to 1,000 hours (the default) or 2,000 hours, at install.
Internal components and field wiring are reached from below the unit, per Samsung: no hatch to plan beside it.
Source: Samsung mini 4-way cassette installation manual (
Samsung sized it for one tile. AirGreen picks which one.
Samsung designs the cassette. We pick the tile, the drain and line route, then install it.
What SAMSUNG brings
- One 2 × 2 ft tileIn a standard drop-ceiling grid, per Samsung.
- WindFree in summerUnder 0.15 m/s in cooling, per Samsung.
- Built-in leak detectionThe
R-32 sensor is part of the unit, per the submittal. - Single or multi-zoneOn its own outdoor unit, or as a head on an FJM Premium.
What AirGreen brings
- Sold and installed by AirGreenThe visit, the quote, the installation and start-up.
- The right tileAt least 2.5 m off the floor, clear of lights and sprinklers.
- The drain checkedWe test the pump in cooling at start-up.
- RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16.
The mini cassette, in six claims.
True or false? Each card flips to its source.
The 12,000 mini cassette gets more LogisVert than the 12,000 Max Heat wall unit.
In heating, the cassette can switch to WindFree mode.
A duct to the next room can be connected to the cassette.
All three sizes share the same body.
Everything is serviced from below the unit.
The mini cassette can go in a camper van.
These topics have their own page, so we don’t repeat them here.
What people ask about the Samsung cassette.
A standard 2 × 2 ft drop-ceiling grid, at least 2.5 m off the floor as a rule, with room for a 9 13/16 in tall body above it. The opening is 580 to 585 mm square, per Samsung.
Yes, in cooling only: the louvers close and air comes through thousands of micro-holes, at under 0.15 m/s, per Samsung. A humidity sensor in the panel limits the mode when the air is very humid.
Yes, if the drop ceiling is at least 2.5 m above the floor. It takes one 2 × 2 ft tile, blows four ways, and Samsung offers an optional occupancy sensor, the MCR-SMDU.
Down to -25 °C (-13 °F), per Samsung, with high heating capacity at -20 °C (-4 °F). At -25 °C, NEEP lists up to 6,400, 7,000 and 15,400 BTU/h for the 9,000, 12,000 and 18,000.
Yes: the body has a knock-out for outside air, with a booster fan, per Samsung. Samsung publishes neither its size nor the airflow. A duct to another room, on the other hand, does not apply to WindFree models.
No. Samsung sells the controls separately: a wired wall control, or a wireless remote. The panel already has the display and the infrared receiver, and the remote is also used to set up Wi-Fi.
Yes: Samsung lists it among the heads compatible with FJM Premium multi-zone. The LogisVert amount then goes to the system. We confirm the combination in the quote.
Per the submittal, the Wi-Fi adapter is built into the
Hydro-Québec excludes indoor units installed outside the insulation envelope, for example in the attic or roof space. If the cassette body ends up in an unheated attic, the install falls in that case: we check the location during the visit.
Hydro-Québec first requires 12,000 BTU/h in cooling. ENERGY STAR certifies the 9,000 cassette at 9,100 BTU/h: it is not on the list, even though it gives 9,700 BTU/h at -8 °C, more than the other CAC 9,000s.
Only with a lot of
No question matches. Call us: 514 316-2973.
No drop ceiling? The rest of the Samsung line.

SAMSUNG wall-mounted heat pumps
WindFree Standard and Max Heat, 9,000 to 24,000 BTU/h.
See the collection
2, 3 or 4-head multi-zone
FJM Premium: up to 4 rooms on one outdoor unit.
See the collection
Hylex central heat pumps
Standard and Premium, 2 to 5 tons, on your ducts.
See the collection
“Add-on” central systems
A Hylex coil on the furnace you keep.
See the collection
Hylex electric furnaces
The Hylex indoor unit in place of an electric furnace.
See the collection
SAMSUNG ducted units
Slim duct hidden in a ceiling or closet.
See the collection
SAMSUNG floor consoles
Low on the wall, often under a window.
See the collection
SAMSUNG thermostats and Wi-Fi
We pick the tile with you.
We look at the ceiling height, the grid, the drain and the refrigerant line route, then hand you a clear quote with the AHRI number and the LogisVert amount from Hydro-Québec’s list.
Hydro-Québec does no phone or door-to-door solicitation for LogisVert. A call “from Hydro-Québec” selling a heat pump? Hang up.


Sources checked October 14 to 26, 2026
- Samsung HVAC, Slim Duct, WindFree Mini 4-Way Cassette and Console pages; CAC Premium
R-32 submittals (versions 10072024A and 02132025A). - ENERGY STAR, Certified Air-Source Heat Pumps (dataset w7cv-9xjt), queried by AHRI number on Oct. 14, 2026.
- Hydro-Québec, residential LogisVert page and LogisVert Participation Guide v1.10 (Sept. 15, 2026), checked Oct. 8, 2026.
- airgreen.ca product pages, Oct. 8, 2026.
- Samsung CAC Premium
R-32 submittals (Slim Duct 02132025A; WindFree Mini 4-Way Cassette and Console 10072024A and 02132025A), Slim Duct data book Ver. 3.1 and Console data book Ver. 1.1, installation manualsDB68-12926A-00 ,DB68-12928A-04 andDB68-12932A-02 (re-read Oct 26, 2026). - American Academy of Audiology, “Levels of Noise in Decibels”, 2023 (sound references).
- Hydro-Québec, LogisVert Participation Guide v1.10 (Sept 15, 2026): ineligible work.
- NEEP, Cold Climate Air Source Heat Pump List, records read by AHRI number on Oct. 14, 2026 (COP, coldest point listed, HSPF2 region V).
- Hydro-Québec, list of heat pumps eligible for LogisVert (owner, existing home), re-read Oct. 26, 2026: amounts and “capacity at -8 °C”.
- Samsung HVAC, WindFree Mini 4-Way Cassette page (samsunghvac.com), re-read Oct. 14, 2026.
LogisVert amounts come from Hydro-Québec’s list, re-read Oct. 26, 2026; Hydro-Québec confirms them when you apply. Prices on quote.
Our Samsung cassettes, right below.
Each product page gives the models, the AHRI number, the dimensions and the certified performance.