The Samsung slim duct: nothing on the wall, 199 mm in the ceiling.
Samsung’s Slim Duct hides above the ceiling and blows into one room through a short duct. It is 199 mm high; Samsung wants 20 mm more under it, a hatch that depends on your ceiling and a static pressure set between 0.01 and 0.24 in. WC. LogisVert: $1,056 (12,000) and $1,944 (18,000).
- 199 mm high, all three sizes
- Built-in condensate pump
- Optional leak detection
Height of all three sizes, per Samsung. Plan on 219 mm: Samsung wants 20 mm more under the unit.
Samsung Slim Duct submittals (version 02132025A).
At -8 °C, the 18,000 heats almost twice as much as the 12,000.
Three sizes, two LogisVert amounts. Pick one: models, AHRI number, certified heat at -8 °C and the math. When there is no amount, we tell you why.

Not sure about the size? We work it out on site: insulation, windows, orientation, ceiling height.

Slim duct · 9,000 BTU/h
AC009DNLDCG + AC009DXSCCG · AHRI 216441743
Under 12,000 BTU/h: below the LogisVert minimum.
At -25 °C, its coldest certified point, NEEP lists up to 6,700 BTU/h for it, at a COP of 1.55.

Slim duct · 12,000 BTU/h
AC012DNLDCG + AC012DXSCCG · AHRI 216441744
Amount on Hydro-Québec’s LogisVert list (Oct. 26, 2026), $120 / 1,000 BTU/h at -8 °C
At -25 °C, its coldest certified point, NEEP lists up to 7,000 BTU/h for it, at a COP of 1.77.

Slim duct · 18,000 BTU/h
AC018DNLDCG + AC018DXSCCG · AHRI 215220929
Amount on Hydro-Québec’s LogisVert list (Oct. 26, 2026), $120 / 1,000 BTU/h at -8 °C
At -25 °C, its coldest certified point, NEEP lists up to 15,400 BTU/h for it, at a COP of 1.67.
Below the joists, 2.2 m up or more, for one room.
35 7/16 in wide (43 5/16 in on the 18,000) by 17 5/16 in deep: it hangs below the joists, in a bulkhead, a closet or a drop ceiling, not between two joists.
For a ceiling install, Samsung asks for at least 2.2 m (7.2 ft) between the floor and the unit.
Samsung intends the Slim Duct for free-air discharge or a duct serving one room only. We plan the duct at the visit.
Samsung lists the Slim Duct among the FJM Premium multi-zone heads: it can replace a wall unit in a bedroom.
Where the air goes, and where the water goes.
The Slim Duct draws room air, heats or cools it, then blows it through a grille. Pick the mode and the return: from the bottom, Samsung warns that noise rises by 3 to 6 dB(A).
Illustration. Sources: Samsung Slim Duct submittals (02132025A); installation manual
Drop tiles: no hatch. Drywall: one or two.
The Slim Duct is 199 mm high and Samsung wants 20 mm more under it: count on 219 mm. For service, it has to be reached from below. Pick your ceiling, the size and the clear height above: we check the room, then the manual’s hatches.
Drywall with less than 50 cm above: two hatches, A, 1,000 mm long (the unit’s width plus 100 mm), and B, 500 mm.
And always: at least 20 mm under the unit, and at least 2.2 m off the floor. Service is from below or from the side, per Samsung.
Source: Samsung installation manual
From 0.01 to 0.24 in. WC: the right range is set at start-up.
Static pressure is the resistance of the ducts and grilles that the fan has to push against. The Slim Duct doesn’t adjust itself: Samsung sets five ranges, and the installer enters the right one with a wired control. Slide to your duct pressure.
Range 2 of 5
Samsung says it plainly: the automatic air-volume function can’t be used on the AC***DNLDCG.
The option code can only be set from the main wired wall control, per the manual.
A wrong code may cause an error or a breakdown, Samsung warns: the installation specialist enters it.
Worth knowing: 0.24 in. WC is the pressure of a water column about 6 mm high. The Slim Duct pushes air through a short duct, not through a whole-house duct network.
Source: Samsung Slim Duct submittal 02132025A (0.10 standard, 0.01 and 0.24 in. WC); manual
Six duct layouts: which ones pass?
Samsung and Hydro-Québec each have rules for Slim Duct ducts. Tap a card, then the right bin: allowed, with a condition, or ruled out.
Tap a card first, then the bin.
Duct to one bedroom. Allowed: Samsung intends the Slim Duct for free-air discharge or a duct serving one room only.
Two rooms. Ruled out: one room per Slim Duct, per the manual. For two rooms, we plan two units or a multi-zone.
Bottom return. Allowed: the manual allows a bottom return. Samsung warns it adds 3 to 6 dB(A).
Drop ceiling as return. With a condition: only if a refrigerant leak detection system is installed, per Samsung. On the Slim Duct, the
Ducts in the attic. Ruled out of LogisVert: Hydro-Québec refuses indoor units and ducts outside the insulation envelope, for example in the attic or roof space.
A spark in the duct. Ruled out: Samsung forbids any auxiliary system in the ducts that could be an ignition source.
Did you know: a drop-ceiling return needs leak detection. It is an option on the Slim Duct, and built into the mini cassette and the console.
Source: Samsung installation manual
Same outdoor unit, three ways to heat the room.
The Slim Duct, the mini cassette and the console run on the same three CAC Premium outdoor units. Pick a size and a measure: the certified numbers show what each format gains or gives up.
Heat certified at -8.3 °C (17 °F) by ENERGY STAR, under each combination’s AHRI number: the “capacity at -8 °C” Hydro-Québec uses for LogisVert.
Cooling certified by ENERGY STAR. Hydro-Québec requires at least 12,000 BTU/h in cooling: that is where the 12,000 console loses its amount.
Seasonal cooling efficiency (SEER2), certified by ENERGY STAR. Higher is better.
Seasonal heating efficiency (HSPF2, region IV), certified by ENERGY STAR. Higher is better.
Sound pressure at the highest fan speed, per Samsung’s submittals. Lower is quieter. Samsung does not publish the test conditions.
Amount on Hydro-Québec’s LogisVert list (re-read Oct 26, 2026). No 9,000 is on it: their cooling is under 12,000 BTU/h.
At 9,000, the mini cassette gives the most heat at -8 °C (9,700 BTU/h) and the best SEER2 (22.00). None of the three has a LogisVert amount.
At 12,000, the mini cassette leads at -8 °C (10,700 BTU/h) and gets the most ($1,284). The 12,000 console is certified at 10,200 BTU/h in cooling: no amount.
At 18,000, the Slim Duct leads at -8 °C (16,200 BTU/h) and gets the most ($1,944); the mini cassette keeps the best SEER2 (20.50).
| Measure | Slim Duct (ducted) | WindFree mini cassette | Console |
|---|---|---|---|
| Where it goes | Above the ceiling, ducted to one room | In the ceiling, one 2 × 2 ft tile | On the floor or low on the wall |
| Minimum height | 2.2 m off the floor | 2.5 m, as a rule | Floor level |
| Condensate | Built-in pump, 29 in lift | Built-in pump, 29 in lift | By gravity (65 mm hole), or a third-party pump |
| Leak detection | Optional ( | Built in | Built in |
| Control | Sold separately | Sold separately | Rechargeable remote included |
Source: ENERGY STAR, dataset w7cv-9xjt, the nine CAC Premium records by AHRI number (heat at 17 °F, cooling, SEER2, HSPF2), read Oct 14, 2026; Samsung submittals (sound at high speed, pump “maximum 29” lift”, leak detection, controls); manuals
Up to $1,944, checked by AHRI number.
ENERGY STAR cold-climate certified: $120 per 1,000 BTU/h of heat at -8 °C, from 12,000 BTU/h. Pick a size to see the math, or the reason when there is no amount.
AC018DNLDCG + AC018DXSCCG · AHRI 215220929
AC012DNLDCG + AC012DXSCCG · AHRI 216441744
AC009DNLDCG + AC009DXSCCG · AHRI 216441743
Under 12,000 BTU/h: below the LogisVert minimum.
July 8, 2027
For installations completed on or after November 26, 2025, the unit must be ENERGY STAR certified.
The outdoor unit needs a nominal cooling capacity of at least 12,000 BTU/h.
Apply no later than nine months after installation. The grant never exceeds 100% of the pre-tax cost.
The amount follows the installed combination, outdoor and indoor, as listed under its AHRI number.
Source: Hydro-Québec, list of heat pumps eligible for LogisVert (owner, existing home), by AHRI number, re-read Oct. 26, 2026; Participation guide v1.10 (Sept. 15, 2026). Hydro-Québec’s list prevails; the final amount is confirmed when you apply. Our LogisVert guide
The Slim Duct, size by size.
Size, weight, sound, airflow and line limits: Samsung’s numbers, drawn out. Pick a size.
Outdoor unit · 67.2 lb
Indoor unit · 42.3 lb
Sound, with everyday references
Rustling leaves30
Whisper40
Quiet library50
Moderate rain60
Conversation
References in dB: American Academy of Audiology. The unit’s values are those Samsung publishes, in dB(A); the references only give a sense of scale.
Outdoor unit · 67.2 lb
Indoor unit · 42.3 lb
Sound, with everyday references
Rustling leaves30
Whisper40
Quiet library50
Moderate rain60
Conversation
References in dB: American Academy of Audiology. The unit’s values are those Samsung publishes, in dB(A); the references only give a sense of scale.
Outdoor unit · 116.84 lb
Indoor unit · 49.6 lb
Sound, with everyday references
Rustling leaves30
Whisper40
Quiet library50
Moderate rain60
Conversation
References in dB: American Academy of Audiology. The unit’s values are those Samsung publishes, in dB(A); the references only give a sense of scale.
Sources: Samsung Slim Duct submittals (02132025A) and technical data book Ver. 3.1 (pump lift: 29.53 in). Dimensions W × H × D. The 18,000 is rated 17,500 BTU/h in cooling. Fan: 84 W per the 9,000 and 18,000 submittals.
The full plate, size by size.
The three Slim Duct sizes side by side, with Samsung’s own term under each row. Where Samsung publishes nothing, the cell says so.
| Size | 9,000 | 12,000 | 18,000 |
|---|---|---|---|
| Identification | |||
| Indoor unitIndoor unit · US Code | |||
| Outdoor unitOutdoor unit · US Code | |||
| AHRI numberAHRI Certified Ref. No. | 216441743 | 216441744 | 215220929 |
| ENERGY STAR IDENERGY STAR Unique ID | 3891548 | 3891549 | 3621196 |
| LogisVert, Hydro-Québec listre-read Oct. 26, 2026 | not listed | $1,056 | $1,944 |
| Heating | |||
| Rated capacity, cooling / heatingNominal capacity (BTU/h) | 9,000 / 12,000 | 12,000 / 14,000 | 17,500 / 20,000 |
| Heating rangeCapacity range, heating | 2,900 – 16,000 | 3,000 – 17,000 | 3,000 – 25,000 |
| Heat at 8.3 / -8.3 °CENERGY STAR, 47 / 17 °F | 12,000 / 8,100 | 14,000 / 8,800 | 20,000 / 16,200 |
| COP at 8.3 / -8.3 °CNEEP, 47 / 17 °F | 3.41 / 2.20 | 3.60 / 2.69 | 3.20 / 2.16 |
| COP at -15 °CENERGY STAR, 5 °F | 1.80 | 1.80 | 1.80 |
| Coldest certified point, -25 °CNEEP, -13 °F | up to 6,700 BTU/h · COP 1.55 | up to 7,000 BTU/h · COP 1.77 | up to 15,400 BTU/h · COP 1.67 |
| Efficiency | |||
| SEER2 / EER2ENERGY STAR | 20.10 / 13.50 | 19.60 / 11.80 | 17.00 / 11.70 |
| HSPF2, region IV / region VSamsung · NEEP | 9.60 / 7.7 | 9.50 / 7.6 | 9.00 / 7.5 |
| Sound | |||
| Indoor, low / mid / highSound pressure, dB(A) | 26 / 30 / 33 | 27 / 31 / 34 | 28 / 32 / 35 |
| Outdoor, high speedCooling / Heating (high), dB(A) | 53 / 53 | 54 / 54 | 58 / 58 |
| Test conditions | not published | not published | not published |
| Air and water | |||
| Airflow, low / mid / highCFM | 247 / 283 / 325 | 325 / 385 / 456 | 353 / 459 / 600 |
| Static pressureExternal static pressure, in. WC | 0.10 standard · 0.01 to 0.24 | 0.10 standard · 0.01 to 0.24 | 0.10 standard · 0.01 to 0.24 |
| Condensate pumpDrain pump | built in, 29 in lift | built in, 29 in lift | built in, 29 in lift |
| A2L leak detectionA2L Leak Detection | optional ( | optional ( | optional ( |
| Installation | |||
| Power · MCA / MOP208-230 V, 1 ph, 60 Hz | 13.9 A / 15 A | 13.9 A / 15 A | 22.7 A / 25 A |
| Line setLiquid / gas (in) | 1/4 + 3/8 in | 1/4 + 3/8 in | 1/4 + 1/2 in |
| Max length / max riseft | 66 / 49 ft | 66 / 49 ft | 164 / 98 ft |
| Factory charge for 24.6 ft · maximum | 31.7 · 38.4 oz | 31.7 · 38.4 oz | 60.0 · 82.4 oz |
| Outdoor W × H × D · weightin · lb | 31 1/8 × 21 5/8 × 11 3/16 in · 67.2 lb | 31 1/8 × 21 5/8 × 11 3/16 in · 67.2 lb | 34 5/8 × 31 3/8 × 12 3/16 in · 116.84 lb |
| Indoor W × H × D · weightin · lb | 35 7/16 × 7 13/16 × 17 5/16 in · 42.3 lb | 35 7/16 × 7 13/16 × 17 5/16 in · 42.3 lb | 43 5/16 × 7 13/16 × 17 5/16 in · 49.6 lb |
- Static pressure in pascals: Samsung prints it only in in. WC and mmAq.
- A fresh-air knock-out: none in the Slim Duct documents.
- The minimum line length: the manual only says to keep it “at a minimum”.
- The sound test conditions, and how to read the model numbers.
Sources: Samsung CAC Premium submittals (Slim Duct 02132025A; cassette and console 10072024A and 02132025A); Slim Duct data book Ver. 3.1 and Console data book Ver. 1.1; ENERGY STAR (w7cv-9xjt); NEEP, read by AHRI number on Oct. 14, 2026; Hydro-Québec’s LogisVert list re-read Oct. 26, 2026. HSPF2 region V comes from NEEP: Samsung prints region IV only. The 18,000s are rated under 18,000 BTU/h in cooling: that is their size class, not their rating.
Samsung builds it to hide. AirGreen plans the duct.
Samsung designs the unit. We pick the size, the hatch and the duct route, then register it with Samsung.
What SAMSUNG brings
- Nothing on the wall199 mm high, hidden above the ceiling, with a discreet grille.
- Built-in pump750 mm of lift, check valve and float switch, per Samsung.
- ENERGY STAR cold climateAll three sizes, by AHRI number; LogisVert from the 12,000 up.
- Single or multi-zoneOn its own outdoor unit, or as a head on an FJM Premium.
What AirGreen brings
- Sold and installed by AirGreenThe visit, the quote, the installation and start-up.
- The hatch in the right placeWe plan it before the ceiling is closed.
- The right pressure rangeEntered at start-up, with a wired control.
- RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16.
The slim duct, in six claims.
True or false? Each card flips to its source.
Samsung ships a remote with the Slim Duct.
The box holds a 1.4 m Wi-Fi wire.
The 18,000 is taller than the 12,000.
Its indoor fan is the most powerful of Samsung’s three CAC units.
In a very humid ceiling, Samsung asks for thicker insulation.
The 9,000 is not cold-climate certified.
These topics have their own page, so we don’t repeat them here.
What people ask about the Samsung slim duct.
Above a ceiling: a drop ceiling, a bulkhead or a closet, at least 2.2 m off the floor. Air goes through a short duct to one room’s grille.
199 mm (7 13/16 in) for all three sizes, per Samsung, which also wants at least 20 mm between the unit and the ceiling: count on 219 mm. The 18,000 is wider, 1,100 mm instead of 900. We measure the space during the visit.
A slim duct serves a single room through short ducts: that is what Samsung’s installation manual specifies. A Hylex central system uses the whole house’s duct network.
Down to -25 °C (-13 °F), per Samsung, with high heating capacity at -20 °C (-4 °F). At -25 °C, NEEP lists up to 6,700, 7,000 and 15,400 BTU/h for the 9,000, 12,000 and 18,000.
Yes, built in: it lifts water up to 750 mm (29.5 in), with a check valve and a float switch that stops the unit if the water rises too high. The drain route follows the drawing in Samsung’s manual: we confirm it at install and test the pump in cooling.
No. Samsung intends it for free-air discharge or a duct serving one room only. For two rooms, we plan two units or an FJM Premium multi-zone, where the Slim Duct can be one of the heads.
Only if a refrigerant leak detection system is installed, per Samsung’s manual. On the Slim Duct, the
Yes: Samsung lists it among the heads compatible with FJM Premium multi-zone. The LogisVert amount then goes to the system. We confirm the combination in the quote.
Samsung’s submittals list it as built in, and the box holds a 1,400 mm Wi-Fi wire; the Slim Duct web page still mentions an adapter sold separately. We confirm it for your unit in the quote.
No. Hydro-Québec excludes indoor units and ducts installed outside the insulation envelope, for example in the attic or roof space. We place the unit on the heated side of the house, and check it during the visit.
Under drop tiles, no: a tile lifts out. Under drywall, Samsung’s manual asks for a 500 mm hatch B if there is more than 50 cm above, and two hatches, A (the unit’s width plus 100 mm) and B, if there is less.
The installer, at start-up. Samsung sets five ranges between 0.01 and 0.24 in. WC, 0.10 as standard, and the code is entered from the main wired control. The Slim Duct has no automatic airflow setting.
No question matches. Call us: 514 316-2973.
No room in the ceiling? The rest of the Samsung line.

SAMSUNG wall-mounted heat pumps
WindFree Standard and Max Heat, 9,000 to 24,000 BTU/h.
See the collection
2, 3 or 4-head multi-zone
FJM Premium: up to 4 rooms on one outdoor unit.
See the collection
Hylex central heat pumps
Standard and Premium, 2 to 5 tons, on your ducts.
See the collection
“Add-on” central systems
A Hylex coil on the furnace you keep.
See the collection
Hylex electric furnaces
The Hylex indoor unit in place of an electric furnace.
See the collection
SAMSUNG ceiling cassettes
WindFree mini 4-way cassette, 2 × 2 ft.
See the collection
SAMSUNG floor consoles
Low on the wall, often under a window.
See the collection
SAMSUNG thermostats and Wi-Fi
We measure your ceiling before we suggest a size.
We look at the clear height, the hatch, the duct and the refrigerant line route, then hand you a clear quote with the AHRI number and the LogisVert amount from Hydro-Québec’s list.
Hydro-Québec does no phone or door-to-door solicitation for LogisVert. A call “from Hydro-Québec” selling a heat pump? Hang up.


Sources checked October 14 to 26, 2026
- Samsung HVAC, Slim Duct, WindFree Mini 4-Way Cassette and Console pages; CAC Premium
R-32 submittals (versions 10072024A and 02132025A). - ENERGY STAR, Certified Air-Source Heat Pumps (dataset w7cv-9xjt), queried by AHRI number on Oct. 14, 2026.
- Hydro-Québec, residential LogisVert page and LogisVert Participation Guide v1.10 (Sept. 15, 2026), checked Oct. 8, 2026.
- airgreen.ca product pages, Oct. 8, 2026.
- Samsung CAC Premium
R-32 submittals (Slim Duct 02132025A; WindFree Mini 4-Way Cassette and Console 10072024A and 02132025A), Slim Duct data book Ver. 3.1 and Console data book Ver. 1.1, installation manualsDB68-12926A-00 ,DB68-12928A-04 andDB68-12932A-02 (re-read Oct 26, 2026). - American Academy of Audiology, “Levels of Noise in Decibels”, 2023 (sound references).
- Hydro-Québec, LogisVert Participation Guide v1.10 (Sept 15, 2026): ineligible work.
- NEEP, Cold Climate Air Source Heat Pump List, records read by AHRI number on Oct. 14, 2026 (COP, coldest certified point, HSPF2 region V).
- Hydro-Québec, list of heat pumps eligible for LogisVert (owner, existing home), re-read Oct. 26, 2026: amounts and “capacity at -8 °C”.
- NIST, SP 811, Appendix B.9 (1 inch of water = 249.0889 Pa).
LogisVert amounts come from Hydro-Québec’s list, re-read Oct. 26, 2026; Hydro-Québec confirms them when you apply. Prices on quote.
Our Samsung ducted units, right below.
Each product page gives the models, the AHRI number, the dimensions and the certified performance.