Four rooms, one outdoor unit.
Four heads, the most the range takes, on one 24,000, 30,000 or 36,000 BTU/h outdoor unit: Samsung lists 55 sets of four heads. The Samsung FJM Premium heats down to -25 °C and keeps 100% of its heating performance down to -15 °C, per Samsung. LogisVert, all wall heads: $1,824 to $2,760 for the system.
- 55 sets in Samsung’s tables
- Three 4-port outdoor units
- WindFree™ heads, 7,000 to 24,000
All four ports are in use: two 3/8 in gas ports, two 1/2 in, with the adapters Samsung supplies.
Samsung FJM Premium submittals (02142025A).
Four heads: three possible outdoor units, starting at the 24,000.
Pick an outdoor unit: its model, its ports, the heads it takes with 4 heads, its certified capacity at -8 °C and the LogisVert amount of the all-wall-head listing, with the math.
55 sets in all
The outdoor unit size follows the rooms: we size each one during the visit.
FJM Premium 24,000 · 4 heads
Hydro-Québec’s LogisVert list, all-wall-head listing (Oct. 26, 2026)
With a slim duct, cassette or console head, the AHRI listing changes, and so does the amount: we confirm it in the quote.
FJM Premium 30,000 · 4 heads
Hydro-Québec’s LogisVert list, all-wall-head listing (Oct. 26, 2026)
With a slim duct, cassette or console head, the AHRI listing changes, and so does the amount: we confirm it in the quote.
FJM Premium 36,000 · 4 heads
Hydro-Québec’s LogisVert list, all-wall-head listing (Oct. 26, 2026)
With a slim duct, cassette or console head, the AHRI listing changes, and so does the amount: we confirm it in the quote.
Source: Samsung FJM Premium submittals (02142025A); Hydro-Québec’s LogisVert list, all-wall-head listings, read Oct. 26, 2026 (“Puissance à -8 °C”); SEER2 and HSPF2: Samsung’s “Non-ducted” column and the ENERGY STAR record for each AHRI number.
Four heads: is your set in Samsung’s table?
Pick each room’s head. The tool looks the set up in the tables of the three four-port units. With four heads, only the total counts.
Sizes come from the load calculation for each room, done at the visit. Here you see what Samsung’s combination table accepts, unit by unit.
No FJM Premium lists this set. Change a size, or talk to us at the visit.
Why a refusal: our reading of Samsung’s tables, where each unit has two limits, the heads’ total and the biggest head. Separate units: one Max Heat of the same size per room (a 7,000 head becomes a 9,000, the smallest Max Heat); under 12,000 BTU/h, no amount. The LogisVert guide doesn’t say whether several systems in one home each get an amount, so we never add them up.
Source: combination tables in Samsung FJM Premium submittals (02142025A); amounts: Hydro-Québec’s LogisVert list, all-wall-head listings, read Oct. 26, 2026; Max Heat: same list, Oct. 14, 2026.
126 ways to pick four heads. The 36,000 accepts 37.
With six head sizes there are 126 sets of four. Samsung lists 3 on the 24,000, 15 on the 30,000 and 37 on the 36,000. Our reading of the tables: with four heads, only the total counts.
Refused at 49,0007 + 9 + 9 + 247 + 9 + 15 + 187 + 12 + 12 + 187 + 12 + 15 + 15
On the 36,000, every set of four heads totalling 48,000 BTU/h or less is in the table, and none above. That’s our reading of Samsung’s 37 rows; we confirm yours in the quote. On a computer, hover a dot to read its set. The lightest refused set is 49,000 BTU/h, 1,000 too many.
Source: four-head tables in Samsung AJ024/030/036DXS4CG submittals (02142025A): 3, 15 and 37 rows; six head sizes AJ007 to
Four heads on the 24,000: at least two are wall heads.
The 24,000 with four heads only takes 7,000s and 9,000s, and the 7,000 only comes as a wall head. So a slim duct, cassette or console goes in as a 9,000, two at most (7,000 + 7,000 + 9,000 + 9,000). On the 30,000 and 36,000 you get more choice. Restrictions apply, so we confirm it in the quote.
The only family offered in 7,000 and 24,000. WindFree mode in summer.
- 7,000 to 24,000 BTU/h
Nothing on the wall. One slim duct serves one room, per Samsung.
- 9,000, 12,000, 18,000 BTU/h
Panel sized for a 2 × 2 ft ceiling grid, WindFree mode in summer.
- 9,000, 12,000, 18,000 BTU/h
Often under a window. The 15,000 is multi-zone only.
- 9,000, 12,000, 15,000, 18,000 BTU/h
Source: Samsung FJM Premium submittals (02142025A), compatibility matrix (“** Restrictions apply”); Samsung model lists by family; slim duct manual
Four heads on four ports.
All four ports are in use. Switch between four wall heads and a mix of families, then follow the start-up.
Illustration. Ports and adapters: Samsung AJ024/030/036DXS4CG submittals (02142025A); addressing: installation manual
Two floors, four lines: the total is what breaks first.
Four times 82 ft is 328 ft; Samsung allows 230 ft in total. Move the outdoor unit back: each line stays under 82 ft long after the total passes 230.
Each line’s length (illustrative house): horizontal run to the wall and out to the unit, plus the head’s height, plus 6 ft for wall passes and fittings.
With four heads we don’t just look at the longest line, we add up all four. Two heads at most can be at 82 ft; the other two then share 66 ft, and the average line can’t exceed 57.5 ft (17.5 m). Our math, on Samsung’s limits. The demo moves the unit back once, when the section comes into view.
Source: Samsung FJM Premium submittals (02142025A): 82 ft per head, 230 ft in total, 49 ft of height, 25 ft between heads; installation manual
Four heads, the most the range takes. Fewer rooms? This way.
Multi-zone 2 heads
4 outdoor units, 20,000 to 36,000; from 14,000 BTU/h of heads.
See the pageMulti-zone 3 heads
4 outdoor units, 20,000 to 36,000; from 21,000 BTU/h of heads.
See the pageMulti-zone 4 heads
3 outdoor units, 24,000 to 36,000; from 28,000 BTU/h of heads.
You’re hereSource: combination tables in Samsung FJM Premium submittals (02142025A): 62 pairs, 83 trios, 55 sets of four; samsunghvac.com, “up to four zones with one outdoor unit”.
Four small rooms: one FJM 24,000, or four 9,000 wall units?
Both heat and cool. What changes: the number of outdoor units, the LogisVert amount, the lowest heating temperature and the distances allowed. Switch to count the boxes outside.
| FJM 24,000 (7,000 + 7,000 + 9,000 + 9,000) | 4 × Max Heat 9,000 | |
|---|---|---|
| Outdoor units | 1 · 194.0 lb · 37 × 47 5/8 × 13 in | 4 · 71.0 lb each (284.0 lb) · 4 × 31 1/8 in = 124 1/2 in side by side |
| LogisVert | $1,824 (AHRI 216372794, all wall heads) | $0: each unit is 9,000 BTU/h in cooling, under the 12,000 minimum |
| Heats down to | -25 °C; 100% down to -15 °C, per Samsung | -30 °C; 100% down to -20 °C, per Samsung |
| Lines | 82 ft per head, 230 ft in total | 66 ft per unit |
| Max breaker | 40 A | 20 A per unit |
Four small rooms: four 9,000 wall units are 124 1/2 in wide side by side, with no LogisVert amount. There is no 7,000 Max Heat, so a 7,000 head counts as a 9,000. The
Source: Samsung FJM Premium (02142025A) and WindFree Max Heat (10072024A) submittals; Hydro-Québec’s LogisVert list (FJM: Oct. 26, 2026; Max Heat: Oct. 14, 2026). Widths and sums: our math.
Four rooms: 109.3 oz of R-32 , versus 136 oz for four wall units.
The FJM ships with 109.3 oz and Samsung says to add none. Four 9,000 wall units each start at 34.0 oz, plus 0.16 oz per foot past 24.6 ft. Slide the line length per room.
109.3 oz · 3,100 g · factory charge, nothing to add
139.5 oz · 3,954 g · 34.0 oz each for 24.6 ft, plus 0.16 oz per foot beyond
less with the FJM, our math
With two or three rooms it’s the reverse: two or three 9,000 wall units hold less
One charge for four rooms also means each room with a head must meet Samsung’s
Source: Samsung FJM Premium submittals (109.3 oz, 3,100 g; “Do not add refrigerant”) and WindFree Max Heat 9,000 submittal (34.0 oz for 24.6 ft, 10072024A); AR**DX*** wall-unit manual (0.16 oz per foot beyond 24.6 ft); ENERGY STAR, “
Four rooms: one 4-head system, or two dual-zones?
Both can be done with FJM Premium. Pick a set of four heads: we compare one outdoor unit against two, with Samsung’s numbers.
7,000 + 7,000 + 9,000 + 9,000 · one 24,000 or 7,000 + 7,000 on the 20,000 + 9,000 + 9,000 on the 20,000
| One 4-head | Two dual-zones | |
|---|---|---|
| Outdoor units | 1 · 24,000 · 194.0 lb | 2 · 383.6 lb in total |
| 109.3 oz | 2 × 109.3 = 218.6 oz | |
| Outdoor sound, heating | 52 dB(A) | 51 dB(A) · 51 dB(A) |
| LogisVert, all wall heads | $1,824 (AHRI 216372794) | $1,584 (20,000, AHRI 216372795) · $1,584 (20,000, AHRI 216372795): worked out per system, never added up. Two systems in one home? Only Hydro-Québec confirms the assistance granted. |
| Lines | 4 × 82 ft max, 230 ft to share | 2 × 82 ft per system: the 230 ft cap never comes into play |
| AHRI numbers, start-ups | 1 | 2 |
9,000 + 9,000 + 9,000 + 9,000 · one 30,000 or 9,000 + 9,000 on the 20,000 + 9,000 + 9,000 on the 20,000
| One 4-head | Two dual-zones | |
|---|---|---|
| Outdoor units | 1 · 30,000 · 194.0 lb | 2 · 383.6 lb in total |
| 109.3 oz | 2 × 109.3 = 218.6 oz | |
| Outdoor sound, heating | 53 dB(A) | 51 dB(A) · 51 dB(A) |
| LogisVert, all wall heads | $2,100 (AHRI 216372793) | $1,584 (20,000, AHRI 216372795) · $1,584 (20,000, AHRI 216372795): worked out per system, never added up. Two systems in one home? Only Hydro-Québec confirms the assistance granted. |
| Lines | 4 × 82 ft max, 230 ft to share | 2 × 82 ft per system: the 230 ft cap never comes into play |
| AHRI numbers, start-ups | 1 | 2 |
12,000 + 12,000 + 12,000 + 12,000 · one 36,000 or 12,000 + 12,000 on the 20,000 + 12,000 + 12,000 on the 20,000
| One 4-head | Two dual-zones | |
|---|---|---|
| Outdoor units | 1 · 36,000 · 194.0 lb | 2 · 383.6 lb in total |
| 109.3 oz | 2 × 109.3 = 218.6 oz | |
| Outdoor sound, heating | 53 dB(A) | 51 dB(A) · 51 dB(A) |
| LogisVert, all wall heads | $2,760 (AHRI 216372792) | $1,584 (20,000, AHRI 216372795) · $1,584 (20,000, AHRI 216372795): worked out per system, never added up. Two systems in one home? Only Hydro-Québec confirms the assistance granted. |
| Lines | 4 × 82 ft max, 230 ft to share | 2 × 82 ft per system: the 230 ft cap never comes into play |
| AHRI numbers, start-ups | 1 | 2 |
7,000 + 7,000 + 7,000 + 24,000 · one 36,000 or 7,000 + 24,000 on the 30,000 + 7,000 + 7,000 on the 20,000
| One 4-head | Two dual-zones | |
|---|---|---|
| Outdoor units | 1 · 36,000 · 194.0 lb | 2 · 385.8 lb in total |
| 109.3 oz | 2 × 109.3 = 218.6 oz | |
| Outdoor sound, heating | 53 dB(A) | 53 dB(A) · 51 dB(A) |
| LogisVert, all wall heads | $2,760 (AHRI 216372792) | $2,100 (30,000, AHRI 216372793) · $1,584 (20,000, AHRI 216372795): worked out per system, never added up. Two systems in one home? Only Hydro-Québec confirms the assistance granted. |
| Lines | 4 × 82 ft max, 230 ft to share | 2 × 82 ft per system: the 230 ft cap never comes into play |
| AHRI numbers, start-ups | 1 | 2 |
Each system uses the smallest unit that lists its heads. Four 12,000 heads fit on one 36,000, or on two 20,000s: 12,000 + 12,000 = 24,000, under their 27,000 ceiling. A 4-head system puts one unit outside; two dual-zones put two, with two AHRI numbers and two start-ups. We look at both at the visit.
Source: 2- and 4-head tables in Samsung FJM Premium submittals (02142025A); weight and sound: same submittals; amounts: Hydro-Québec’s LogisVert list, all-wall-head listings, Oct. 26, 2026. Weight and refrigerant sums: our math.
Four heads, three outdoor units: $1,824 to $2,760.
With four heads the 20,000 is out, so the lowest amount becomes $1,824, the 24,000’s. One outdoor unit, one AHRI number, one amount for all four rooms. Pick a unit.
Source: Hydro-Québec, list of heat pumps eligible for LogisVert (owner, existing home), read Oct. 26, 2026, by AHRI number; the list prevails and the final amount is confirmed when you apply. With ducted heads or a mix of heads, the AHRI listing changes, and so does the amount: each unit’s three listings are on the 2-head page. The program rules are explained once, on the Samsung page.
The 4-head plate: three units, side by side.
The three four-port outdoor units, side by side, with Samsung’s own term under each row. Where Samsung publishes nothing, the cell says so.
| Outdoor unit | 24,000 | 30,000 | 36,000 |
|---|---|---|---|
| Identification | |||
| Outdoor unitModel (US code) | |||
| Ports4 Port Condensing Unit | 4 | 4 | 4 |
| Capacity indexCapacity Index | 24 | 30 | 36 |
| AHRI number, all wall headsMultizone All Non-Ducted | 216372794 | 216372793 | 216372792 |
| ENERGY STAR ID, all wall headsENERGY STAR Unique ID | 3891561 | 3891560 | 3891558 |
| LogisVert, Hydro-Québec listOct. 26, 2026, all wall heads | $1,824 | $2,100 | $2,760 |
| With 4 heads | |||
| Combinations in the table4-unit rows | 3 sets | 15 sets | 37 sets |
| Connected heads, lightest to heaviestBTU/h | 28,000 to 32,000 | 28,000 to 40,000 | 28,000 to 48,000 |
| Share of the index (our math) | 117 to 133 % | 93 to 133 % | 78 to 133 % |
| Largest head allowedBTU/h | 9,000 | 18,000 | 24,000 |
| Free ports | 0 of 4 | 0 of 4 | 0 of 4 |
| Heating, all wall heads | |||
| Rated capacity, cooling / heatingRated capacity, non-ducted (BTU/h) | 25,000 / 25,000 | 28,400 / 28,600 | 34,000 / 36,600 |
| Heat at 8.3 / -8.3 / -15 °CENERGY STAR, 47 / 17 / 5 °F | 25,000 / 15,200 / 25,000 | 28,600 / 17,500 / 28,600 | 36,600 / 23,000 / 36,600 |
| COP at 8.3 / -8.3 °CNEEP, 47 / 17 °F | 4.70 / 2.89 | 3.99 / 2.83 | 4.21 / 2.45 |
| COP at -15 °CENERGY STAR, 5 °F | 1.85 | 1.81 | 2.04 |
| Coldest point listed on NEEP, -25 °CNEEP, -13 °F | up to 18,000 BTU/h · COP 1.61 | up to 20,000 BTU/h · COP 1.87 | up to 20,000 BTU/h · COP 1.87 |
| Min / max capacity at 8.3 °CNEEP, 47 °F | 7,600 / 42,000 | 7,600 / 54,500 | 7,600 / 54,500 |
| Efficiency | |||
| SEER2 / EER2Non-ducted | 23.00 / 14.55 | 22.50 / 13.50 | 21.50 / 12.50 |
| HSPF2, region IV / region VSamsung · NEEP | 10.4 / 7.1 | 10.0 / 6.9 | 9.5 / 7.7 |
| Sound | |||
| Outdoor, cooling / heating, highSound Pressure Level, dB(A) | 51 / 52 | 52 / 53 | 52 / 53 |
| Distance and test conditions | not published | not published | not published |
| Installation | |||
| Power · MCA / max breaker1 / 208-230 / 60 | 35.9 A / 40.0 A | 35.9 A / 40.0 A | 35.9 A / 40.0 A |
| Liquid / gas connectionsHigh side / Low side (suction), in | 1/4 × 4 / 3/8 × 2 + 1/2 × 2 | 1/4 × 4 / 3/8 × 2 + 1/2 × 2 | 1/4 × 4 / 3/8 × 2 + 1/2 × 2 |
| Adapters includedIncluded Pipe Adapters, in | 2 × 1/2 × 3/8 | 2 × 1/2 × 3/8 | 2 × 1/2 × 3/8 + 2 × 1/2 × 5/8 |
| 109.3 oz (3,100 g) · 230 ft | 109.3 oz (3,100 g) · 230 ft | 109.3 oz (3,100 g) · 230 ft | |
| Lines: per head / total / minimumft | 82 / 230 / 10 ft | 82 / 230 / 10 ft | 82 / 230 / 10 ft |
| Rise: to the outdoor unit / between headsft | 49 / 25 ft | 49 / 25 ft | 49 / 25 ft |
| Outdoor W × H × D · weightin · lb | 37 × 47 5/8 × 13 in · 194.0 lb | 37 × 47 5/8 × 13 in · 194.0 lb | 37 × 47 5/8 × 13 in · 194.0 lb |
| Base pan heaterSamsung: “as standard” · NEEP | standard · 150 W per NEEP | standard · 150 W per NEEP | standard · 150 W per NEEP |
- The distance and conditions behind the sound figures, indoors and out.
- The base pan heater’s power: Samsung writes “as standard”, NEEP lists 150 W.
- How to read its model numbers: Samsung writes them with wildcards (AJ0**DXS*CG).
- Whether the heads’ leak detector changes each room’s
R-32 minimum floor area: the manual doesn’t say.
Sources: Samsung FJM Premium submittals (02142025A; 24,000 and 36,000 adapters re-read Oct. 26, 2026) and combination tables; manual
Four heads, one Samsung unit, one AirGreen crew.
Samsung makes the unit and its 55 sets. AirGreen traces the four lines, installs and addresses the four heads.
What SAMSUNG brings
- 55 sets of four headsIn Samsung’s tables, on three units.
- Four portsOn the 24,000, 30,000 and 36,000, with the adapters supplied.
- ENERGY STAR cold climateOur three 4-head FJM Premium units, all-wall-head listing.
- Down to -25 °CAnd 100% of heating performance down to -15 °C, per Samsung.
What AirGreen brings
- Sold and installed by AirGreenThe visit, the quote, the install and the start-up.
- Four lines traced at the visit230 ft in total, shared by the four heads.
- Four heads addressedAt start-up, following Samsung’s procedure.
- RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16.
The 4-head multi-zone, in six claims.
True or false? Flip the cards: the answers come from Samsung’s submittals and manuals, and Hydro-Québec’s list.
On a 4-head FJM 24,000, you can use a 12,000 head.
FJM wall heads can be mounted 4 ft off the floor.
The 7,000, 9,000 and 12,000 heads are exactly the same size.
For four 3/8 in heads on the 24,000, Samsung ships adapters.
A 4-head FJM 30,000 accepts a 24,000 head.
An FJM 36,000 can run four 12,000 heads.
These apply across the Samsung range: they have their own page, so we don’t repeat them here.
What people ask about 4-head multi-zones.
No. Samsung says it plainly for its wall controls: “Group control is not supported for R32 systems”. Each head keeps its own setting: remote, Samsung’s app, or one wall control per head.
Yes, if the combination is in the table. On the 24,000, only as a 9,000, and two at most: the other two rooms get 7,000 wall heads.
No. 4 × 82 = 328 ft, and Samsung allows 230 ft in total. Two lines at most can be 82 ft; the other two share 66 ft.
It only has three ports: Samsung calls it a “3 Port Condensing Unit”. For four heads you need the 24,000, the 30,000 or the 36,000.
Yes, only on the 36,000: 4 × 12,000 = 48,000 BTU/h of heads, its table maximum.
Yes. Samsung notes that automatic head addressing works between 5 and 40 °C outside (41 to 104 °F) and at 16 °C (60.8 °F) or more inside; outside that range, we set the addresses by hand, as its manual provides.
One calculation for the system, by its AHRI number: $1,824 (24,000) to $2,760 (36,000) with wall heads, per Hydro-Québec’s list of Oct. 26, 2026. With ducted heads or a mix, the listing changes, and so does the amount.
No question matches. Call us: 514 316-2973.
More than four rooms? With ducts, the Hylex central system.
Four heads is an FJM Premium’s maximum. For a house with ducts, the Hylex central system serves every room through the ducts. The rest of the Samsung range.

SAMSUNG wall-mounted heat pumps
WindFree Standard and Max Heat, 9,000 to 24,000 BTU/h.
See the collection
Hylex central heat pumps
Standard and Premium, 2 to 5 tons, on your ducts.
See the collection
“Add-on” central systems
A Hylex coil on the furnace you keep.
See the collection
Hylex electric furnaces
The Hylex indoor unit in place of an electric furnace.
See the collection
SAMSUNG ducted units
Slim duct hidden in a ceiling or closet.
See the collection
SAMSUNG ceiling cassettes
WindFree mini 4-way cassette, 2 × 2 ft.
See the collection
SAMSUNG floor consoles
Low on the wall, often under a window.
See the collection
SAMSUNG thermostats and Wi-Fi
Wired controllers and Wi-Fi adapter.
See the collectionFour rooms, one Samsung outdoor unit, installed by AirGreen.
We trace the four lines, check every room, pick the heads and the outdoor unit with you, and hand you a clear quote with the AHRI number and the LogisVert amount from Hydro-Québec’s list.
Hydro-Québec does no phone or door-to-door solicitation for LogisVert. A call “from Hydro-Québec” selling a heat pump? Hang up.


Sources checked on October 14 and 26, 2026
- Samsung FJM Premium submittals
AJ020DXS3CG and AJ024/030/036DXS4CG, version 02142025A (files of Jan. 14, 2026), combination tables included; read Oct. 14, 2026, AJ024 and AJ036 re-read Oct. 26, 2026. - Samsung installation manuals
DB68-13175A-00 (FJMR-32 outdoor unit) andDB68-13426A-01 (AJ0**DNADCG wall heads); technical data book “Free Joint Multi … (R32, 60Hz, HP)”, Ver. 1.2 (head data). - samsunghvac.com, “Free Joint Multi Premium” page, read Oct. 14, 2026.
- ENERGY STAR, Certified Air-Source Heat Pumps (dataset w7cv-9xjt), records read by AHRI number on Oct. 14, 2026.
- NEEP, Cold Climate Air Source Heat Pump List, records read by AHRI number on Oct. 14, 2026 (listing classes, COP, coldest point, base pan heater).
- Hydro-Québec, list of heat pumps eligible for LogisVert (owner, existing home): file of Oct. 14, 2026, FJM rows re-read Oct. 26, 2026; Participation guide v1.10 (Sept. 15, 2026).
- Samsung WindFree Max Heat submittals (10072024A) and AR**DX*** wall-unit installation manual, for the comparisons with separate wall units.
- ENERGY STAR, refrigerant field “
R-32 (GWP:675 | Lower GWP)”, for the CO2 equivalent (our math).
LogisVert amounts are indicative: Hydro-Québec confirms them when you apply. Prices on quote.
Our 4-head Samsung multi-zones, right below.
Each listing gives the outdoor unit, the AHRI number and the certified ratings. The head sizes allowed are those in Samsung’s table, above.