Dettson EHIA Electric Heater Kit for Duotec Air Handler

In stock

Electric backup heat for Dettson Duotec air handlers, in single-phase kits from 10 to 25 kW.

AirGreen codeAG-AC-14002

10 to 25 kWfour kits
1 to 3 circuitsdepending on output
240 / 208 Vsingle phase
Duotec air handlerGenuine part
Model
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

AirGreen codeAG-AC-14002
BrandDettson
Part no.EHIA10KN10 to EHIA25KB10
ForDettson Duotec AHV08 to AHV20 air handlers
Power supplySingle phase, 240 or 208 V

EHIA electric heater kits are field installed in Dettson Duotec series air handlers. They provide backup heat for a central heat pump by warming the duct air. The Duotec specifications list single-phase kits from 5 to 25 kW; this page groups the 10, 15, 20 and 25 kW models.

Actual output depends on voltage

The kit’s documentation gives its actual output at 240 V and at 208 V. The EHIA10KN10, for example, delivers 9.6 kW at 240 V and 7.2 kW at 208 V. The 10 kW model connects to a terminal block, with no breaker; the 15, 20 and 25 kW models have built-in circuit breakers.

One or several circuits

  • EHIA10KN10: one circuit
  • EHIA15KB10 and EHIA20KB10: one circuit or two
  • EHIA25KB10: one circuit or three

Before ordering

Dettson’s Duotec specifications exclude some output and airflow combinations: we check your air handler size before choosing the kit. Have your electrical service checked before choosing a high output.

Installed by AirGreen in Greater Montréal

We install the kit in your Dettson air handler and set up the backup heat with the heat pump in Montréal, Laval, Longueuil, on the South Shore and on the North Shore; the supply circuit is done by a licensed electrician. RBQ licence 5645-9605-01. For availability or a quote, call us at 514 316-2973 or email sales@airgreen.ca with the air handler model, the output and the quantity.

01 · What it is for

Backup heat for the Duotec air handler

Field installed in the air handler, the kit warms the duct air when the heat pump needs extra heat.

  • Backup heat for a central heat pump with a Dettson Duotec air handler
  • Homes heated electrically through ductwork
  • Adding backup heat to an existing Duotec air handler
  • Replacing an EHIA kit
Published actual outputThe documentation gives each kit’s output at 240 V and at 208 V.
Terminal block or breakersThe 10 kW kit uses a terminal block; the 15 to 25 kW kits have breakers.
One or several circuitsThe 15 and 20 kW kits take one or two circuits; the 25 kW, one or three.
Compatible with
AHV08AHV12AHV16AHV20
Per the manufacturer. Send us your unit’s model number and we confirm before ordering.
02 · Sizes

4 sizes, one page

Each size has its own AirGreen code. Tap a row to select it.

ModelOutput at 240 / 208 VOutput at 240 / 208 V (BTU/h)Heater current at 240 / 208 VCircuitsProtectionPower supplyPart no.AirGreen code
10 kW – EHIA10KN109.6 / 7.2 kW32,756 / 24,56740.0 / 34.6 A1Terminal block, no breakerSingle phaseEHIA10KN10AG-AC-14001
15 kW – EHIA15KB1014.4 / 10.8 kW49,134 / 36,85160.0 / 51.9 A1 or 2Circuit breakersSingle phaseEHIA15KB10AG-AC-14002
20 kW – EHIA20KB1019.2 / 14.4 kW65,513 / 49,13480.0 / 69.2 A1 or 2Circuit breakersSingle phaseEHIA20KB10AG-AC-14003
25 kW – EHIA25KB1024 / 18 kW81,891 / 61,418100.0 / 86.5 A1 or 3Circuit breakersSingle phaseEHIA25KB10AG-AC-14004

Nominal output in the name; actual output at 240 V and 208 V is in the table for the model you pick.

03 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

BrandDettson
TypeField-installed electric heater kit
Nominal outputs10, 15, 20 and 25 kW
Power supplySingle phase, 240 or 208 V
ProtectionTerminal block (EHIA10KN10), circuit breakers (EHIA15KB10, EHIA20KB10, EHIA25KB10)
Air handlersDettson Duotec AHV08, AHV12, AHV16, AHV20
Output at 240 / 208 V14.4 / 10.8 kW
Output at 240 / 208 V (BTU/h)49,134 / 36,851
Heater current at 240 / 208 V60.0 / 51.9 A
Circuits1 or 2
ProtectionCircuit breakers
Power supplySingle phase
Part no.EHIA15KB10
AirGreen codeAG-AC-14002
04 · Before installing

What to know before installing

  • Dettson excludes some output and airflow combinations in the Duotec specifications: we check your air handler size before ordering.
  • Actual output depends on voltage: the EHIA10KN10 delivers 9.6 kW at 240 V and 7.2 kW at 208 V.
  • The kits are single phase.
  • The supply circuit is done by a licensed electrician, with the unit powered off.
05 · Documents

Manufacturer documents

06 · Goes with

You may also need

Same category
Original parts
See all
07 · Questions

Frequently asked questions

Which kit fits my Duotec air handler?

Dettson’s Duotec specifications list EHIA kits from 5 to 25 kW and exclude some output and airflow combinations. Send us your air handler model number and we confirm before ordering.

Why 9.6 kW and not 10 kW?

The kit’s documentation gives its actual output: 9.6 kW at 240 V and 7.2 kW at 208 V for the EHIA10KN10, whose nominal output is 10 kW.

How many circuits do I need?

One for the 10 kW, one or two for the 15 and 20 kW, one or three for the 25 kW.

Can you install it?

Yes. We fit the kit in the air handler and set up the backup heat with the heat pump; the supply circuit is run by a licensed electrician, everywhere in Greater Montréal.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

Backup heat for your Dettson Duotec air handler

Tell us the size and the quantity: we confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 19, 2026.