GENERAL AIRSTAGE FJ-AC-485-1 BACnet MS/TP Module (Intesis Gateway)

In stock

The gateway the manufacturer lists to connect its AIRSTAGE heat pumps to a building management system over BACnet MS/TP or Modbus RTU.

AirGreen codeAG-AC-103

BACnet MS/TPbuilding management network
Modbus RTUper the manufacturer’s description
R-32 H-Seriesmost unit families
BACnetGenuine part
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

AirGreen codeAG-AC-103
BrandGENERAL (formerly Fujitsu General)
Part no.FJ-AC-485-1
Manufacturer nameIntesis - BACnet MSTP & Modbus RTU Gateway
ForR-32 AIRSTAGE H-Series heat pumps

The GENERAL AIRSTAGE FJ-AC-485-1 BACnet module is the gateway the manufacturer lists for integrating its AIRSTAGE heat pumps into a building management system, and it is identical to the module sold under the Fujitsu AIRSTAGE brand. Fujitsu General Limited has carried the name GENERAL Inc. since January 1, 2026; the manufacturer, its factories and the AIRSTAGE lineup remain the same. In the manufacturer’s accessory lists, the module appears as the “Intesis - BACnet MSTP & Modbus RTU Gateway”: the gateway is designed by Intesis for AIRSTAGE equipment (GENERAL or Fujitsu).

If your plans refer to the gateway by its former name, see the same part under the Fujitsu AIRSTAGE brand; the GENERAL brand is gradually replacing the old one, and both are in circulation during the transition.

Heat pumps in centralized management

Managers of commercial buildings, schools or seniors’ residences often run lighting, ventilation and heating from one central workstation. The FJ-AC-485-1 gateway brings the AIRSTAGE heat pumps into that workstation, over a BACnet MS/TP network or, per the manufacturer’s description, over Modbus RTU. Each indoor unit then appears in the system, which can monitor and control it.

Compatible unit families

  • Altair 500 (ASUH**KPAS), Orion XLTH (ASUH**KZAS) and Orion XLTH+ wall-mounted heat pumps
  • ACUH and AUUH cassettes, as well as the suspended ceiling unit
  • ADUH and ARUH ducted units, and AMUH air handlers
  • Floor units in the AGUH family

Preparing the network connection

Network parameters are set with the integrator in charge of the management system. If the network runs on Modbus only, the manufacturer also offers the UTY-VMSX converter. Before ordering, we go over the protocol, the number of units and the model of each one with you.

Networking with AirGreen

Connecting the gateway to the units is our part of the job; the network setup is done hand in hand with your integrator, in Montreal, Laval, Longueuil, on the South Shore and on the North Shore. RBQ licence 5645-9605-01 applies to all of our work. The number of units to integrate helps us prepare the quote: mention it when you call 514 316-2973 or write to sales@airgreen.ca, including for an availability question.

01 · What it is for

The heat pump inside the building management system

The manufacturer presents the FJ-AC-485-1 as an Intesis BACnet MS/TP and Modbus RTU gateway.

  • Commercial and institutional buildings run by a BACnet system
  • Bringing a wall unit, cassette or ducted unit into central management
  • Projects where the manager wants to monitor and control each unit from one station
  • Modbus RTU installations, per the manufacturer’s description
Two protocolsThe manufacturer describes it as a BACnet MS/TP and Modbus RTU gateway.
Whole H-SeriesIt appears in the accessory list of R-32 wall, cassette, ducted and floor units.
Made by IntesisThe gateway is designed by Intesis for AIRSTAGE equipment (GENERAL or Fujitsu).
Compatible with
ASUH**KPASASUH**KZASASUH**KTASASUH**KTABACUH**KUASAUUH**KUASARUH**KUASADUH**KUASAMUH**KUASAGUH**KUAS
Per the manufacturer. Send us your unit’s model number and we confirm before ordering.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

BrandGENERAL (formerly Fujitsu General)
Part no.FJ-AC-485-1
TypeBACnet MS/TP and Modbus RTU gateway
Gateway makerIntesis
Listed unitsR-32 H-Series: wall, cassette, ducted, floor, air handler
AirGreen codeAG-AC-103
03 · Before installing

What to know before installing

  • The building system integrator must plan network settings (address, speed) with us.
  • Check that your unit appears in the manufacturer’s accessory list before ordering.
  • For a Modbus-only network, the manufacturer also offers the UTY-VMSX converter.
  • It connects inside the indoor unit: have a technician do it.
04 · Goes with

You may also need

Same category
Original parts
See all
05 · Questions

Frequently asked questions

Is my unit compatible?

The manufacturer lists the FJ-AC-485-1 among the accessories of its R-32 AIRSTAGE H-Series systems: Altair 500, Orion XLTH and Orion XLTH+ wall units, ACUH and AUUH cassettes, ADUH and ARUH ducted units, AMUH air handlers, AGUH floor units and the ceiling-suspended unit. Send us the model number and we confirm.

BACnet or Modbus: which one?

It depends on the building management system. The FJ-AC-485-1 is described for BACnet MS/TP and Modbus RTU; for a Modbus-only network, the manufacturer also offers the UTY-VMSX converter.

Is a communication kit required?

The manufacturer’s submittals do not require one for this gateway on Altair 500 and Orion XLTH wall units. We check your unit’s case before installation.

Can you install it?

Yes. We connect the gateway to the unit and work with your integrator on the network setup, everywhere in Greater Montréal.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

Connect your GENERAL or Fujitsu AIRSTAGE heat pumps to your BACnet system

Tell us the size and the quantity: we confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 7, 2026.