GENERAL AIRSTAGE UTY-XWZXZ5 Dry Contact Kit (with Error Output)
GENERAL’s most complete harness for wall-mount units: on/off or forced stop in, run status and error out.
AirGreen codeAG-AC-084
514 316-2973 · sales@airgreen.ca
Quick facts
The GENERAL AIRSTAGE UTY-XWZXZ5 dry contact kit and the Fujitsu AIRSTAGE kit with the same number are the same part. The name change dates from January 1, 2026: Fujitsu General Limited, now under the Paloma Rheem Holdings banner, became GENERAL Inc. without changing factories or model numbers. Known to the manufacturer as the “External Connect Kit”, this harness lets a wall-mounted or floor AIRSTAGE heat pump talk to a building management system, a timer or an external contact. Where the UTY-XWZX harness sticks to on/off and run status, this one adds an error output and lets you turn the input into a forced stop. The same part under the Fujitsu AIRSTAGE brand, identical in every way to the GENERAL one, also has its own page with us.
Controlling the unit and monitoring it from outside
The orange and yellow wires form the input: you connect a dry contact to them which, depending on the chosen setting, starts and stops the unit or forces it off. In forced stop mode, the unit stays off as long as the contact is active, even if someone tries to restart it with the remote. On the output side, the blue and purple wires show whether the unit is running, while the red and white wires report a normal or error status. For the manager of a hotel, a rental building or a shop, it is a way to know on the spot that a unit is in fault.
Manufacturer values
- Input: field-supplied dry contact, at least 24 V DC and 10 mA
- Outputs: 24 V DC at most, from 10 to 500 mA
- Wiring: 10 m maximum from the board to the connected devices
Units the manufacturer provides for
The Altair 500 (ASUH**KPAS), Orion XLTH (ASUH**KZAS) and Orion XLTH+ wall units of the R-32 H series are among the listed units, as are the AGUH**KUAS floor units. If your unit is a cassette or a ducted unit, plan on the UTY-XWZXZG instead.
AirGreen installs it across Greater Montréal
Connecting the kit, configuring the input and wiring the outputs to your system are handled by our technicians, in Montréal, Laval, Longueuil, on the South Shore and on the North Shore. All of this wiring is carried out under AirGreen’s RBQ licence 5645-9605-01. Tell us about your installation at 514 316-2973 or sales@airgreen.ca for availability or a quote.
Monitor the heat pump as well as control it
The UTY-XWZXZ5 adds an error output, so a building system knows right away when the unit is in fault.
- Connection to a building management system or controller
- Forced stop by a safety, window or key-card contact
- Remote alarm when the unit reports an error
- Rental buildings, hotels and shops that monitor several units
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- The input is driven only by a field-supplied dry (voltage-free) contact.
- Connected devices must be within 10 m of the unit’s board.
- Output load: 24 V DC max, 10 to 500 mA.
- On/off or forced stop is chosen in the unit’s settings: a technician handles it.
You may also need
GENERAL AIRSTAGE UTY-XWZX Dry Contact Kit (On/Off and Run Status)
GENERAL AIRSTAGE UTY-XCSXZ2 External Input and Output Board for Wall Unit
GENERAL AIRSTAGE UTY-VMSX Modbus Converter
GENERAL AIRSTAGE FJ-AC-485-1 BACnet MS/TP Module (Intesis Gateway)
Fujitsu Leak Detection System Accessory – UTYSGZU
GENERAL AIRSTAGE Leak Detection System Accessory – UTYSGZU
Hitachi 5-Wire Adapter for 24 V Thermostat – C3STAT01
Hitachi C1STAT01 5-Wire Thermostat Adapter (airHome)Original partsSee all
Frequently asked questions
Is my GENERAL or Fujitsu unit compatible?
The manufacturer lists the UTY-XWZXZ5 for its Altair 500 (ASUH**KPAS), Orion XLTH (ASUH**KZAS) and Orion XLTH+ wall-mount units and its AGUH**KUAS floor units. Send us your indoor unit’s model number and we confirm.
UTY-XWZX or UTY-XWZXZ5?
Choose the UTY-XWZXZ5 if you want an error output or a forced stop. For simple on/off with status feedback, the UTY-XWZX is enough.
What does forced stop mean?
While the contact is active the unit stays off, even if someone tries to start it with the remote. Useful with a window contact or a safety device.
Can you install it?
Yes. Our technicians connect it to the unit, set the input mode and wire the outputs to your system, everywhere in Greater Montréal.
Control and monitoring for your GENERAL or Fujitsu heat pump
Tell us the size and the quantity: we confirm availability and send you a quote. Or let our technicians install it for you.