ARCOAIRE END4X42L17A "N" Evaporator Coil | 3.5 Tons

In stock

Arcoaire 3.5-ton N coil, R-410A, in a 17-1/2 in cabinet with a removable front access panel.

Model numberEND4X42L17A

3.5 tons42,000 BTU/h nominal size
Front accessremovable panel for service
1,225–1,600CFM, airflow range
R-410A17-1/2 in cabinetFactory-installed TXVAvailable while supplies last
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberEND4X42L17A
ManufacturerArcoaire
Size3.5 tons (42,000 BTU/h)
Cabinet width17-1/2 in (445 mm)
Connections3/8 in liquid, 7/8 in suction
Shipping weight52 lb (24 kg)

A 3.5-ton coil that is straightforward to service

Accessible from the front

The evaporator coil remains one of the hardest parts of a central system to reach: it sits above the furnace, often in a corner of the basement. On Arcoaire’s END4X42L17A, the cabinet’s front panel comes off. The technician inspects and cleans the coil without undoing the connection to the furnace, which makes service simpler and faster.

The rest of the cabinet follows the same logic: pre-painted steel, foil-faced insulation to keep it from sweating, hemmed flanges. Inside, the main tubing and fins are aluminum, with copper stubs for the connections, and the TXV is bolted on at the factory, equalizer tube already brazed in.

At a glance

The END4X42L17A is a 3.5-ton (42,000 BTU/h) N evaporator coil, R-410A, in a 17-1/2 in cabinet that lines up flush with furnace and air handler cabinets of the same width. It installs in upflow or downflow. For a 21 in unit, the same capacity comes as the END4X42L21A.

It suits good-sized single-family homes and two-storey houses heated by a 17-1/2 in electric furnace, on the North Shore as in Laval, whether to add central air conditioning or to replace a cased coil of the same width.

Before installation: lines, clearance and airflow

Three checks come before ordering. The refrigerant lines first: the coil calls for a 7/8 in suction connection and a 3/8 in liquid connection, and lines of the wrong diameter or in poor condition are replaced before installation. Clearance next: room must be kept in front of the cabinet to remove the access panel. The blower last, which must deliver 1,225 to 1,600 CFM, the range given for this size. Since the ICP sheet does not state use with a heat pump, we also confirm the match with the outdoor unit.

Installation by AirGreen

The on-site estimate is free and you receive a written quote. Our technicians set the coil, connect the plenum, braze the lines, hook up one of the two condensate drains, run the leak test and the evacuation, then commission the system. A family business established in Montreal for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.

Arcoaire grants a 5-year limited parts warranty, plus an additional 5 years with timely registration, for owner-occupied homes. This model is available while supplies last; sold alone, it is not eligible for the LogisVert grant.

Ask for your free estimate in Montreal, Laval, Longueuil, on the North Shore or on the South Shore, and learn about financing.

01 · What it is for

A 3.5-ton coil designed for service

The END4X42L17A sits flush on a 17-1/2 in electric furnace or air handler, in upflow or downflow, and connects to a 3.5-ton R-410A outdoor unit. Its removable front panel gives access to the coil for service.

  • 3.5-ton central air conditioning on a 17-1/2 in electric furnace
  • Replacing a cased R-410A coil of the same width
  • Good-sized single-family homes and two-storey houses with ductwork
  • Homeowners who have their system serviced regularly
Front access panelRemovable, it gives access to the coil for inspection and cleaning.
5.35 sq ft face area16 x 16 in slab and 16 fins per inch, according to the ICP sheet.
Factory-installed TXVBolt-on metering device, equalizer tube already brazed in.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerArcoaire
TypeCased N evaporator coil
Nominal size3.5 tons (42,000 BTU/h)
RefrigerantR-410A
Metering deviceBolt-on TXV, factory installed (equalizer tube brazed in)
ConfigurationUpflow or downflow
MaterialAluminum main tubing and fins, copper stubs for field connection
CabinetPre-painted steel, foil-faced insulation, non-sweat, removable front access panel, hemmed flanges
Cabinet width (dimension E)17-1/2 in (445 mm)
Other ICP drawing dimensions, in (mm)A 21-1/8 (537) · B 13-7/8 (352) · C 3-9/16 (91) · D 15-3/4 (400) · F 7/8 (22)
Airflow range1,225 to 1,600 CFM
Face area5.35 sq ft
Fins16 per inch
Coil slab (H x L)16 x 16 in
Liquid connection3/8 in
Suction connection7/8 in
Condensate drainTwo connections
Shipping weight52 lb (24 kg)
Manufacturer warrantyParts: 5 years, plus an additional 5 years with timely registration (owner-occupied residential use)
Model numberEND4X42L17A
03 · Before installing

What to know before installing

  • Available while supplies last.
  • Sold alone: not eligible for the LogisVert grant.
  • 7/8 in suction connection: we check the diameter and condition of the existing refrigerant lines.
  • Keep clearance in front of the cabinet so the access panel can be removed.
  • The ICP sheet does not state use with a heat pump: we confirm the match before ordering.
  • The blower must deliver 1,225 to 1,600 CFM, the range given for this size.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
ARCOAIRE
See all
06 · Questions

Frequently asked questions

What is the front access panel for?

It comes off to give access to the coil. The technician can then inspect and clean it without undoing the connection to the furnace.

When should the coil be cleaned?

That depends mostly on the filter and how the system is used. A filter changed regularly spaces out cleanings; a technician checks the coil’s condition during service.

Are my refrigerant lines suitable?

The coil calls for a 7/8 in suction connection and a 3/8 in liquid connection. We check the diameter and condition of the lines in place during the visit.

Is there a wider version?

Yes. The END4X42L21A offers the same capacity in a 21 in cabinet, for units of that width.

Does it work with a heat pump?

The ICP spec sheet does not say so for this model. We confirm the match with your outdoor unit before ordering.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

An easy-access 3.5-ton coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom