LG LKMMA18A1 Evaporator A-Coil | 1.5 Tons
The LG LKMMA18A1 1.5-ton R-32 cased coil sits on your furnace and, matched with the LG KUSXA181A outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberLKMMA18A1
514 316-2973 · sales@airgreen.ca
Quick facts
LKMMA18A1: the 14-1/2 in. LG coil for narrow furnaces
In a condo or plex mechanical room, the furnace often leaves no margin at all. That is the kind of space LG had in mind with the LKMMA18A1: a cased evaporator A-coil of 1.5 tons that is only 14-1/2 in. wide. It runs on R-32 refrigerant and sits on top of a furnace or a blower cabinet. In Montreal, Laval, Longueuil, on the North Shore and on the South Shore, we install it with the LG outdoor unit made for it.
Why width comes before everything else
Before talking about performance, we measure. A coil that is wider than the furnace forces us to build a transition; a coil that is too narrow lets air slip around the fins. At 14-1/2 in., the LKMMA18A1 is the narrowest of the LKMMA series we offer, and it suits the compact furnaces found in older Montreal buildings and small Longueuil bungalows.
Its full dimensions are 14-1/2 in. wide, 24 in. high and 21 in. deep, with a net weight of 44 lb. Two people can handle it without a hoist, which matters when the basement stairs are tight.
What an A-coil actually does
Picture two slanted fin plates leaning against each other at the top. Air from the blower rises through the centre, passes through both faces, and comes out cooler and drier. Inside the tubes, liquid refrigerant evaporates and carries heat away from the air. Moisture in the air condenses on the fins, drops into the pan and leaves through the condensate drain.
The drain measures 1-1/4 in. outside diameter and 1 in. inside diameter, with an outlet possible on the left or the right. That double outlet saves a lot of detours in the piping when the water drain is on the wrong side of the mechanical room.
Pairing with the KUSXA181A
A coil on its own has no efficiency rating. The LKMMA18A1 takes on its full meaning once it is connected to the KUSXA181A outdoor unit, an LG inverter-compressor heat pump. Together they form a system carrying AHRI number 216445254, with published ratings of SEER2 15.2 and HSPF2 8.1.
According to the match-up sheet, the system delivers 17,000 BTU/h of cooling and 20,000 BTU/h of heating at 47 °F. The refrigerant connections on the coil are 3/8 in. on the liquid side and 3/4 in. on the suction side.
Who should look at this model
- the condo owner who wants to replace a window air conditioner with a discreet central solution;
- the plex owner whose units each have their own furnace;
- the small, well-insulated house where the heating and cooling load stays modest;
- the owner of an electric furnace who wants to turn it into a central heat pump, with the furnace as backup.
If your home is large or poorly insulated, this size will be too small. We say so plainly: the right size is calculated, not guessed.
LKMMA18A1 or LKMMA18B1: how to decide
Both models have the same nominal capacity of 1.5 tons and the same refrigerant. The difference is the size: the LKMMA18B1 is 17-1/2 in. wide, and the LKMMA18A1 only 14-1/2 in. The first pairs with the KUSXA181A and the KUSXB181A; the second with the KUSXA181A only.
The rule is simple. If your furnace is narrow, the 14-1/2 in. coil avoids a transition. If it is wider, the LKMMA18B1 fits the sheet metal better. And if you are aiming for double the capacity, look instead at the LKMMA24B1, at 2 tons, or at the 2.5-ton and 3-ton models above it.
A July without sticky air
Real summer comfort does not depend only on the temperature on the display: it depends on humidity. A small unit served by an oversized system cools quickly, shuts off, then starts again, without ever drying the air. A coil of this size, properly matched, runs longer and more gently. The water has time to condense on the fins, and the walls no longer keep that clammy feeling that clings to the skin during Montreal heat waves.
It is also quieter in a bedroom next to the mechanical room, which condo occupants appreciate where every sound carries.
Specifications at a glance
- type: cased evaporator coil, LKMMA range;
- nominal size: 1.5 tons, or 18,000 BTU/h;
- refrigerant: R-32, with a leak detection sensor noted in the LG brochure;
- positions: multi-position, meaning upflow, downflow, horizontal left or right;
- connections: 3/8 in. liquid, 3/4 in. suction;
- matched outdoor unit: KUSXA181A.
Heat pump and furnace: who works when
In an "add-on" setup, the furnace keeps its blower, its filters and its ductwork. The coil slides into the plenum, in the path of the air. In summer it cools; in winter, with a heat pump, the cycle reverses and the heat captured outdoors is delivered through the same ducts.
The furnace only takes over when the outdoor temperature drops below the threshold we program with you. You therefore keep backup heating for the deepest cold, which reassures many Quebec homeowners.
What we check at your home before ordering
- the actual width of the furnace, measured on site rather than read from an old invoice;
- the blower's ability to deliver the airflow this system needs;
- the condition of the electrical panel and the location of the outdoor unit;
- access to the drain and the outlet, left or right, that suits best.
The coil uses R-32, so it is paired with an outdoor unit that uses the same refrigerant, installed at the same time. Keeping an old air conditioner is generally not possible.
Our installation in Greater Montreal
AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years. For this coil and its outdoor unit, the work goes like this:
- measuring the furnace, checking the blower and the electrical panel;
- installing the coil in the plenum, with an insulated transition built on site if the width requires it;
- installing the outdoor unit on a pad or bracket, brazed piping, nitrogen leak test and vacuum;
- connecting the condensate drain and the thermostat;
- commissioning, airflow adjustment and an explanation of how the system works.
LogisVert rebate
The matched LG system appears on Hydro-Québec's list of eligible heat pumps. Eligibility is based on the complete system, not on the coil alone. The amount depends on the installation date and on your situation: we check it against the official list when we prepare your quote, then put the file together with you.
Request your estimate
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete LG system. Financing is available to spread out the cost of the project.
The heat pump coil for your furnace
The LKMMA18A1 sits in the plenum of a furnace or air handler. Connected to the LG KUSXA181A outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the LG KUSXA181A outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 14-1/2 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
LGSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 1.5-ton LG coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.