LG

LG LKMMA36B1 Evaporator A-Coil | 3 Tons

In stock

The LG LKMMA36B1 3-ton R-32 cased coil sits on your furnace and, matched with the LG KUSXA361A outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberLKMMA36B1

3 tons36,000 BTU/h nominal
17-1/2 inwidth
R-32refrigerant
R-32Add-on heat pumpCasedAHRI 216445258
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberLKMMA36B1
ManufacturerLG
Size3 tons
Width17-1/2 in
RefrigerantR-32
Outdoor unitKUSXA361A

Three tons in 17-1/2 in.: the LG LKMMA36B1 coil for large homes with an ordinary furnace

"My house is big, but my furnace is an ordinary one." That is exactly the case the LKMMA36B1 is aimed at. This cased evaporator A-coil offers 3 tons of nominal capacity without requiring an oversized furnace: it is only 17-1/2 in. wide. It runs on R-32 refrigerant, and we install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.

A 3-ton capacity in a reasonable footprint

The nominal size is 3 tons, or 36,000 BTU/h. The dimensions are 17-1/2 in. wide, 26 in. high and 21 in. deep, with a net weight of 54 lb. The width is the same as the 2.5-ton coil, which means that on a 17-1/2 in. furnace, you can step up in capacity without changing the look of the installation.

This detail matters for anyone who already has a recent furnace and does not want to replace it: we keep the blower, the filters and the ductwork, and add the coil in the right place.

Two possible outdoor units

The LKMMA36B1 pairs with two LG heat pumps of the same capacity. Here are the AHRI numbers and the published ratings:

  • KUSXA361A, AHRI number 216445258: 34,400 BTU/h of cooling, 37,000 BTU/h of heating at 47 °F, SEER2 15.5, HSPF2 8.9;
  • KUSXB361A, AHRI number 216445247: the same capacities of 34,400 and 37,000 BTU/h, SEER2 15.2, HSPF2 8.4.

The capacities are identical; the efficiency ratings are slightly higher with the KUSXA361A. If your priority is the most favourable rating on paper, the first one stands out. If the outdoor location or the availability of the unit weighs more, the second remains a valid option. In both cases, we write the exact AHRI number on the quote.

Why so many people hesitate between the B and the C

The LKMMA36C1 offers the same 3-ton capacity, but in a cabinet 21 in. wide and with a different match-up. The only real question is therefore a physical one: is your furnace closer to 17-1/2 in. or to 21 in.? If it is the first, the LKMMA36B1 fits without a transition. If it is the second, the C avoids adapting the width.

At equal capacity, a coil that does not match the furnace forces us to build a transition fitting. That is done well, we do it regularly, but we would rather avoid an extra joint when the right model exists.

Higher up in the series, the LKMMA42C1 goes to 3.5 tons in the 21 in. size; lower down, the LKMMA30B1 keeps the 17-1/2 in. width with 2.5 tons.

Is it the right size for your home?

We never choose from floor area alone. A North Shore home with brick walls, a finished basement and large picture windows does not have the same load as a better-insulated Laval home of the same size. The load calculation weighs insulation, windows, orientation and air tightness. If the result lands at 3 tons, this coil is a good candidate; if it lands lower, a smaller size will run longer and dry the air better.

What happens in the plenum

The A-coil is installed in the furnace plenum. The refrigerant enters through a 3/8 in. connection, evaporates in the tubes while capturing heat from the air, then leaves as a gas through a 3/4 in. connection. The condensation water falls into the pan and runs to a drain of 1-1/4 in. outside diameter and 1 in. inside diameter, which exits left or right, whichever suits you.

In winter, the heat pump reverses the cycle and pushes heat from the outdoors into the house. The furnace only steps in below the temperature threshold that we set with you.

Three ways to use it

  • Replace an old central air conditioner: we remove the old coil and the old unit, then install the new set all at once, with R-32 as the common refrigerant.
  • Turn an electric furnace into a central heat pump: this is the classic scenario in homes heated with electricity. The furnace element becomes a backup rather than the main source.
  • Keep the furnace as reserve heating for the deepest cold, with a changeover threshold set according to your habits.

Everyday comfort in a large home

In a good-sized home, the classic flaw is unevenness: the main floor is cool, the upstairs is stifling. A system of the right capacity, running for long periods at moderate output, helps distribute the air more evenly because the ducts carry a continuous flow rather than brief bursts. It is not a miracle: if the ducts are poorly balanced, we point it out and suggest adjustments. But the foundation is good.

In summer, drier air is the other gain: less fogging on basement windows, less of that damp-laundry feeling in the closets.

LKMMA36B1 specifications

  • type: cased evaporator coil;
  • nominal size: 3 tons (36,000 BTU/h);
  • refrigerant: R-32, leak detection sensor according to the LG brochure;
  • positions: upflow, downflow, horizontal left or right;
  • matched outdoor units: KUSXA361A and KUSXB361A.

How we install this system

AirGreen is a family-owned heating and cooling company based in Montreal. For a system of this size, we pay particular attention to the blower, which must deliver enough airflow for 3 tons.

  • measuring the furnace, checking the blower and the electrical panel;
  • installation in the plenum, insulated transition if needed, duct joints sealed;
  • outdoor unit on a pad or bracket, brazed pipes, nitrogen test, vacuum;
  • condensate drain and thermostat connected;
  • start-up, airflow adjustment and an explanation at your home.

Points to confirm before ordering

  • The outdoor unit must use R-32 like the coil and be installed at the same time.
  • Efficiency ratings belong to the matched system, never to the coil alone.
  • The 17-1/2 in. width and the blower airflow are checked during the visit.

LogisVert rebate

The matched LG system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and on your situation; we check it against the official list when we prepare your quote and put the file together with you.

Request your estimate

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete LG system. Financing is available to spread out the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The LKMMA36B1 sits in the plenum of a furnace or air handler. Connected to the LG KUSXA361A outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with the LG KUSXA361A outdoor unit
Certified systemMatched with the KUSXA361A, the system carries AHRI 216445258.
On your furnaceThe blower, filters and existing ducts are kept.
R-32 refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerLG
ModelLKMMA36B1
TypeCased evaporator coil
LineLKMMA
Nominal size3 tons (36,000 BTU/h)
RefrigerantR-32
Liquid connection3/8 in
Suction connection3/4 in
Dimensions W × H × D17-1/2 × 26 × 21 in
Net weight54 lb
Matched outdoor unitKUSXA361A, KUSXB361A
System AHRI number216445258, 216445247
System SEER2 / HSPF215.5 / 8.9
Model numberLKMMA36B1
03 · Before installing

What to know before installing

  • R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 17-1/2 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
LG
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 3-ton LG coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.