LG LKMMA48C1 Evaporator A-Coil | 4 Tons
The LG LKMMA48C1 4-ton R-32 cased coil sits on your furnace and, matched with the LG KUSXA482A outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberLKMMA48C1
514 316-2973 · sales@airgreen.ca
Quick facts
LKMMA48C1: a 4-ton LG coil with three possible outdoor units
Most coils in the LKMMA series pair with one or two outdoor units. The LKMMA48C1 accepts three, which makes it the most versatile of its family on that score. It is a cased evaporator A-coil of 4 tons (48,000 BTU/h) that runs on R-32 refrigerant and is 21 in. wide. For large homes in Laval, on the North Shore or on the South Shore, as well as for properties in Montreal and Longueuil, it opens several avenues without changing the coil.
Three partners, three spec sheets
Here are the certified systems published by LG for this model:
- KUSXA482A, AHRI number 216445261: 45,500 BTU/h of cooling, 50,000 BTU/h of heating at 47 °F, SEER2 15.9, HSPF2 8.9;
- KUSXB481A, AHRI number 216445250: 45,500 BTU/h of cooling, 48,000 BTU/h of heating at 47 °F, SEER2 15.2, HSPF2 8.3;
- KUSXB601A, AHRI number 216445263: 45,500 BTU/h of cooling, 50,000 BTU/h of heating at 47 °F, SEER2 15.9, HSPF2 8.9.
The cooling is identical in all three cases. The first and third sheets show the same heating capacities and the same ratings; the second stays slightly behind on heating and on efficiency. One remark is in order: the KUSXB601A is the outdoor unit normally associated with a 5-ton coil. Here, it is published as a valid match-up for 4 tons, which can be useful depending on availability or the outdoor layout.
How to choose among the three
- Look at the heating first: 50,000 BTU/h at 47 °F with the KUSXA482A or the KUSXB601A, 48,000 with the KUSXB481A.
- Then look at the outdoor space: the units are not all the same size, and we check the location before ordering.
- Finish with the efficiency rating, which comes with the AHRI number.
We give you a quote that specifies which of the three AHRI numbers applies, because rebate eligibility is checked from that number.
Dimensions and weight: plan the access
The cabinet measures 21 in. wide, 30 in. high and 21 in. deep, and weighs 63 lb net. With these measurements, two people need to work together, especially if the mechanical room is in the basement and the stairs are narrow. We plan the route at the visit: removing a door, spotting a clearance, arranging a second technician. Nothing dramatic, but it is better to think about it before installation day.
A 4-ton for what type of home?
A large two-storey suburban home with a finished basement, an older cottage whose insulation has been improved in stages, a property with large south-facing windows: all of these cases can lead to 4 tons. Conversely, a recent, very well-insulated home might need only 3 tons, which is why the load calculation matters. We do not recommend this size to a home that does not need it: an oversized unit cycles too often and removes humidity poorly.
LKMMA48C1 or LKMMA48D1
Both coils have the same 4-ton capacity and share the KUSXA482A. The D is 24-1/2 in. wide, the C 21 in. The D is limited to two match-ups, with the KUSXA482A and the KUSXB481A; the C offers three. What decides is therefore, first, the width of your furnace, and then the variety of outdoor units you need.
One step down in the same width, the LKMMA42C1 offers 3.5 tons; one step up, the LKMMA60C1 offers 5 tons.
What the furnace keeps, what the coil changes
The existing blower, filters and ductwork are kept. In summer, the coil cools and dries the air. In winter, paired with a heat pump, it gives back the heat captured outdoors. The furnace only takes over below the threshold that we program with you. On a 4-ton system, the blower plays a vital role: if it is too weak, we tell you before the order.
What you do not see on a spec sheet
A coil of this size moves a lot of air, and the noise depends less on it than on the duct network. Undersized ducts whistle; a return air that is too small makes the grilles vibrate. Before proposing this system, we therefore look at the return, the main trunk sections and the condition of the plenum. If a correction is needed, we state it clearly in the quote rather than finding it out on installation day.
The R-32 detection sensor that LG mentions is one of the system's safety features; it does not replace regular maintenance, which we recommend every spring.
Planning the job
A complete installation generally takes place in a single planned visit: we reserve access to the mechanical room, cut the power at the right moment, then put the heating back in service before leaving. If you are counting on the furnace in the middle of winter, we avoid leaving you without heat: the schedule is discussed with you so that the house stays comfortable during the work.
Specifications
- type: cased evaporator coil, LKMMA range;
- nominal size: 4 tons (48,000 BTU/h);
- connections: 3/8 in. for liquid, 3/4 in. for suction;
- condensate drain: 1-1/4 in. O.D. and 1 in. I.D., left and right;
- positions: upflow, downflow, horizontal left or right;
- R-32 refrigerant with a leak detection sensor according to the LG brochure.
The installation, step by step
AirGreen, a family-owned heating and cooling company based in Montreal, follows this sequence:
- measuring the furnace, checking the blower and the electrical panel;
- installing the coil in the plenum, with a transition built on site if needed;
- outdoor unit on a pad or bracket, brazed piping, nitrogen test, vacuum;
- connecting the condensate drain and the thermostat;
- commissioning, airflow adjustment and an explanation at your home.
To check before ordering
- R-32: the coil pairs with a unit using the same refrigerant, installed at the same time.
- The published ratings apply to the certified match-up.
- The blower and the furnace width are confirmed at your home.
LogisVert rebate
The matched LG system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and on your situation; we check it against the official list when we prepare your quote and put the file together with you.
Request your estimate
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete LG system. Financing is available to spread out the cost of the project.
The heat pump coil for your furnace
The LKMMA48C1 sits in the plenum of a furnace or air handler. Connected to the LG KUSXA482A outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the LG KUSXA482A outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 21 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
LGSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 4-ton LG coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.