LG LKMMA30B1 Evaporator A-Coil | 2.5 Tons
The LG LKMMA30B1 2.5-ton R-32 cased coil sits on your furnace and, matched with the LG KUSXA301A outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberLKMMA30B1
514 316-2973 · sales@airgreen.ca
Quick facts
LKMMA30B1: 2.5 tons and 26 in. high, the LG coil for mid-size homes
When a two-storey house is bigger than a bungalow but not as big as a large cottage, the 2.5-ton size often becomes the right compromise. The LKMMA30B1 is a cased evaporator A-coil that runs on R-32 refrigerant, 17-1/2 in. wide and 26 in. high. It arrives ready to install on a furnace or blower cabinet. AirGreen installs it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.
The 26 in. height: the detail that changes the visit
On a spec sheet, you mostly read the capacity. In the field, it is the height that creates surprises. A coil 26 in. high goes in the plenum above the furnace, and the mechanical room ceiling or the attic clearance has to leave room for it, with the space needed to reach the filter and the connections.
Here is what we check from the first visit:
- the clear height between the top of the furnace and the ceiling or the lowest beam;
- the distance needed to pull the coil out if a repair ever became necessary;
- the path the refrigerant piping will take to the outside;
- the location of the water drain, since the drain accepts an outlet on the left or the right.
Its full dimensions are 17-1/2 in. wide, 26 in. high and 21 in. deep, with a net weight of 54 lb.
Pairing with the KUSXA301A
This coil is matched with a single outdoor unit: the KUSXA301A, an LG inverter-compressor heat pump. The system carries AHRI number 216445257 and shows 30,000 BTU/h of cooling and 32,000 BTU/h of heating at 47 °F, with SEER2 15.7 and HSPF2 8.8.
A single matched unit also means a quote that is easier to read: no option to weigh, one AHRI number to put on the rebate file. Note that the KUSXA301A also goes with the 2-ton LKMMA24B1, which hints at the kinship between these two coils.
For which home?
A two-storey house with insulated walls and attic, a suburban North Shore residence with large windows, or a good-sized single-level home in Longueuil: these are the cases where the load calculation points to 2.5 tons. Owners with an electric furnace also find a way to reduce use of the heating element, since the heat pump supplies most of the heat during the mild season.
If your load is lower, a smaller model will avoid overly frequent starts. If it is higher, a 3-ton coil will be better suited. A unit that is too big for the house starts and stops constantly: it removes humidity poorly and wears out faster.
Compared with the other 17-1/2 in. coils
Several models share this width; here is where this one stands:
- the LKMMA18B1 and the LKMMA24B1 offer 1.5 and 2 tons respectively for more modest homes;
- the LKMMA36B1 climbs to 3 tons in the same width, with the KUSXA361A or the KUSXB361A;
- the LKMMA36C1, for its part, goes to 21 in. wide for the same 3-ton capacity.
The LKMMA30B1 is therefore the only 2.5-ton model we offer in this series. If your furnace is 21 in. wide, look instead at the C line: it starts at 3 tons.
How heat moves through the coil
The refrigerant arrives as a liquid through the 3/8 in. connection, passes through an expansion device and then evaporates in the tubes, where it absorbs heat from the air. The gas returns to the outdoor unit through the 3/4 in. suction connection. In summer, everything happens as described; in winter, a heat pump reverses the path. Condensation collects in the pan under the fins and flows out through a drain of 1-1/4 in. outside diameter and 1 in. inside diameter.
What you will notice at home
The first change is consistency. Instead of alternating between lukewarm rooms and icy ones, the temperature settles because the air circulates longer, at a calmer pace. The second is humidity: in summer, a properly sized system dries the air in the upstairs bedrooms, where heat builds up in two-storey homes. The third is the single thermostat: one setting for both seasons, with no portable units to move from room to room.
As for the electricity bill, we promise no figure: it depends on insulation, the rate and how you set the furnace's changeover threshold. We discuss it frankly during the visit.
Specifications
- model: LKMMA30B1, LKMMA range;
- nominal size: 2.5 tons, or 30,000 BTU/h;
- R-32 refrigerant, with a leak detection sensor according to the LG brochure;
- installation positions: upflow, downflow, horizontal left or right;
- connections: 3/8 in. liquid and 3/4 in. suction;
- outdoor unit: KUSXA301A.
Installation: from measuring to start-up
AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years. Here is the typical sequence for this system:
- measuring the furnace, checking the blower and the electrical panel;
- installing the coil in the plenum, a transition built on site if needed, and sealing the duct connections;
- installing the outdoor unit on a pad or bracket, brazing the piping, nitrogen leak test and vacuum;
- connecting the condensate drain and the thermostat;
- commissioning, airflow adjustment and an explanation of how the system works.
The furnace keeps its blower and its filters, and it serves as backup heating when the outdoor temperature drops below the threshold programmed with you.
To check before choosing
- R-32: the coil is only paired with an outdoor unit that uses the same refrigerant, installed at the same time.
- The published ratings only apply to the certified matched system.
- The available width and height, as well as the blower, must be confirmed at your home.
LogisVert rebate
The matched LG system appears on Hydro-Québec's list of eligible heat pumps. The amount varies with the installation date and your situation. We consult the official list when we prepare your quote and put the file together with you.
Request your estimate
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete LG system. Financing is available to spread out the cost of the project.
The heat pump coil for your furnace
The LKMMA30B1 sits in the plenum of a furnace or air handler. Connected to the LG KUSXA301A outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the LG KUSXA301A outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 17-1/2 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
LGSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 2.5-ton LG coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.