The LG LKMMA18B1 1.5-ton R-32 cased coil sits on your furnace and, matched with the LG KUSXA181A outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberLKMMA18B1

1.5 tons18,000 BTU/h nominal
17-1/2 inwidth
R-32refrigerant
R-32Add-on heat pumpCasedAHRI 216445255
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberLKMMA18B1
ManufacturerLG
Size1.5 tons
Width17-1/2 in
RefrigerantR-32
Outdoor unitKUSXA181A

LG LKMMA18B1 coil: 1.5 tons, 17-1/2 in. and a choice of two outdoor units

Here is a small coil with a useful feature: it accepts two outdoor partners. The LKMMA18B1 is a cased A-coil of 1.5 tons that runs on R-32 refrigerant. It pairs with the LG KUSXA181A or the KUSXB181A outdoor unit, each with its own AHRI number. For a house in Laval, a plex in Montreal or a bungalow on the South Shore, that gives real freedom of choice without changing the coil.

The three questions customers ask us most often

Does it heat? Yes, as long as it is connected to a heat pump. With a plain central air conditioner, it only cools.

Can I keep my old air conditioner? As a rule, no. R-32 requires an outdoor unit designed for it, and the two components are installed together.

Will my furnace still be useful? Yes. It provides the blower and serves as backup heating when the mercury drops below the threshold set with you.

Two outdoor units, two AHRI numbers

Here are the published match-ups for this model, side by side:

  • with the KUSXA181A: AHRI number 216445255, with 18,000 BTU/h of cooling, 20,000 BTU/h of heating at 47 °F, SEER2 15.2 and HSPF2 8.1;
  • with the KUSXB181A: AHRI number 216445244, the same capacities of 18,000 and 20,000 BTU/h, the same ratings of 15.2 and 8.1.

On paper, the two systems are equal. The choice is therefore made in the field: space available around the exterior wall, availability at the time of the order, the installer's preference for one range. We explain the practical difference during the visit and write the correct AHRI number on the quote, because it is the reference used for the rebate.

What "17-1/2 in." means in a mechanical room

The 17-1/2 in. width is shared by several models in the range, from 1.5 tons up to 3 tons. The coil measures 17-1/2 in. wide, 24 in. high and 21 in. deep; it weighs 46 lb.

If your furnace is narrower or wider, that is not a problem: we build an insulated transition on site. But a transition adds labour, material and one more joint to seal. That is why we prefer to measure the furnace before choosing between this model and its narrower cousin.

How it compares with its neighbours in the series

  • LKMMA18A1: the same capacity of 1.5 tons, but 14-1/2 in. wide and a single partner, the KUSXA181A. The one to favour if the furnace is narrow.
  • LKMMA24B1: the same 17-1/2 in. width, but 2 tons and a match with the KUSXB241A. It suits a home whose load exceeds what 1.5 tons can cover.
  • LKMMA30B1: still 17-1/2 in. wide, with 2.5 tons for a larger home.

In other words, when the furnace width is fixed at 17-1/2 in., the only real variable is capacity, and the load calculation determines it.

The load calculation comes before the catalogue

We do not choose the size from floor area alone. Wall insulation, the number of windows, orientation, air tightness and the family's habits all go into the calculation. An oversized unit cycles too often, dries the air poorly and wears out its components faster. An undersized unit struggles during heat waves. For a small, well-insulated home, the 1.5-ton size is sometimes exactly what is needed; for an older home, it may simply be too modest.

Three homes, three lines of reasoning

A small, well-insulated townhouse in Longueuil with an average-width electric furnace: the LKMMA18B1 goes straight into the plenum, the heat pump handles most of the heating season, and the furnace stays there for the harshest days.

A Montreal duplex whose owner replaces two window air conditioners with a central system in the upper unit: here, it is mostly the quiet and the absence of a unit in the window that make the difference. We check that the existing blower pushes enough air through all the ducts, otherwise the cooling would stay uneven.

A North Shore home whose old central air conditioner has just given out: rather than patching it up, the owner takes the replacement as a chance to switch to a heat pump. They keep their ducts, remove the old coil and the old outdoor unit, then have the new set installed all at once.

Why the certified match-up matters

When two quotes compete, compare the AHRI numbers before the prices. That number links a specific coil to a specific outdoor unit; it confirms that the combination was rated as a whole. A coil chosen at random, even a good one, carries no rating: it is the whole system that counts, and it is also the whole system that is submitted to Hydro-Québec's eligibility list.

LG publishes several match-ups of LKMMA coils certified ENERGY STAR for Canada and the United States, all cold-climate, which is consistent with our Quebec winters.

Specifications

  • model: LKMMA18B1, cased evaporator coil;
  • nominal size: 1.5 tons (18,000 BTU/h);
  • 3/8 in. liquid connection, 3/4 in. suction connection;
  • condensate drain of 1-1/4 in. O.D. and 1 in. I.D., left and right;
  • multiple positions: upflow, downflow, horizontal left or right;
  • R-32 detection sensor mentioned in the LG brochure.

On the furnace: what stays, what changes

The existing blower, filters and ductwork are kept. The coil is added in the plenum, in the path of the air. In winter, with the heat pump, outdoor heat passes through the refrigerant and then into the air of the house; the furnace takes over when needed. Nothing to replace on the distribution side, which reduces the scope of the work.

The coil has no efficiency rating of its own: the ones you see on a quote belong to the matched system.

Installation at your home, from the first call to commissioning

Our heating and cooling team, based in Montreal and active in Longueuil, on the North Shore and throughout Greater Montreal, always follows the same sequence:

  • a visit, measuring the furnace and examining the electrical panel;
  • checking the blower, which must deliver the system's airflow;
  • installing the coil in the plenum, sealing the duct joints;
  • outdoor unit on a bracket, brazing the pipes, nitrogen test, vacuum;
  • connecting the drain and the thermostat, then final adjustment and explanation.

To check before buying

  • The coil and the outdoor unit must share the same refrigerant, R-32.
  • The published ratings apply to the certified match-up, not to a mix of parts from different sources.
  • The furnace width must be confirmed on site before ordering.

LogisVert rebate

The matched LG system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and on your situation. We check it against the official list when we prepare your quote and put the file together with you.

Request your estimate

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete LG system. Financing is available to spread out the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The LKMMA18B1 sits in the plenum of a furnace or air handler. Connected to the LG KUSXA181A outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with the LG KUSXA181A outdoor unit
Certified systemMatched with the KUSXA181A, the system carries AHRI 216445255.
On your furnaceThe blower, filters and existing ducts are kept.
R-32 refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerLG
ModelLKMMA18B1
TypeCased evaporator coil
LineLKMMA
Nominal size1.5 tons (18,000 BTU/h)
RefrigerantR-32
Liquid connection3/8 in
Suction connection3/4 in
Dimensions W × H × D17-1/2 × 24 × 21 in
Net weight46 lb
Matched outdoor unitKUSXA181A, KUSXB181A
System AHRI number216445255, 216445244
System SEER2 / HSPF215.2 / 8.1
Model numberLKMMA18B1
03 · Before installing

What to know before installing

  • R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 17-1/2 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
LG
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 1.5-ton LG coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.