LG

LG LKMMA24B1 Evaporator A-Coil | 2 Tons

In stock

The LG LKMMA24B1 2-ton R-32 cased coil sits on your furnace and, matched with the LG KUSXB241A outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberLKMMA24B1

2 tons24,000 BTU/h nominal
17-1/2 inwidth
R-32refrigerant
R-32Add-on heat pumpCasedAHRI 216445245
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberLKMMA24B1
ManufacturerLG
Size2 tons
Width17-1/2 in
RefrigerantR-32
Outdoor unitKUSXB241A

LKMMA24B1: the 2-ton LG coil that accepts the KUSXB241A or the KUSXA301A

Between the small 1.5-ton size and the 2.5-ton and 3-ton models, the LKMMA24B1 sits in the middle of the LG range. It is a cased evaporator A-coil of 2 tons that runs on R-32 refrigerant. Its 17-1/2 in. width lets it fit on many forced-air furnaces. We offer it across the whole region: Montreal, Laval, Longueuil, the North Shore and the South Shore.

The only 2-ton coil in the series

In the LKMMA list that we install, only one model carries the 2-ton label, or 24,000 nominal BTU/h. That simplifies the decision: if your load calculation lands at that level, the LKMMA24B1 is the answer, and the real question becomes which outdoor unit will go with it.

It measures 17-1/2 in. wide, 24 in. high and 21 in. deep, and weighs 46 lb. The liquid connection is 3/8 in. and the suction connection 3/4 in.

Two match-ups, two personalities

This is where the model stands out. LG publishes two certified systems that use this coil:

  • KUSXB241A, AHRI number 216445245: 21,600 BTU/h of cooling, 24,000 BTU/h of heating at 47 °F, SEER2 15.2 and HSPF2 8.5;
  • KUSXA301A, AHRI number 216445264: 23,000 BTU/h of cooling, 26,000 BTU/h of heating at 47 °F, SEER2 15.5 and HSPF2 8.8.

The second system shows higher capacities and ratings. It uses the same outdoor unit as the one that goes with the 2.5-ton LKMMA30B1, which shows that this coil's flexibility is not only about the size of the house. We look with you at what matters most: the heating capacity at 47 °F, the space available outdoors, or the rating that is most advantageous for your file.

What a heat pump adds to a furnace

The LKMMA24B1 slides into the plenum of a furnace or blower cabinet. In summer, it cools the air passing through it. In winter, paired with a heat pump, it delivers the heat captured outdoors into the ducts you already have. The furnace remains available as backup heating; it takes over below the temperature threshold that we program together.

For a family that heats with electricity, it is the most direct way to reduce reliance on baseboards or the furnace element without redoing the whole air distribution.

The 2-ton coil or its immediate neighbours

  • LKMMA18B1: the same 17-1/2 in. width, but 1.5 tons. More modest, it targets small floor areas and well-insulated units.
  • LKMMA30B1: the same width, 2.5 tons, matched with the KUSXA301A. It suits homes where the load exceeds what 2 tons can handle.
  • LKMMA18A1: only 14-1/2 in. wide and 1.5 tons; useful if the furnace is very narrow.

The width does not change from one of these models to the next, except for the narrowest. Capacity is therefore what separates these coils, and it is the load calculation, not the impression of heat or cold, that should decide.

A concrete example of the reasoning

Imagine a two-storey house in Laval, renovated a few years ago, with recent windows and a redone attic. The load calculation shows an average need, which 2 tons cover without excess. We do not choose 2.5 tons "to be safe": an oversized unit starts and stops constantly, removes humidity poorly and ages faster. Conversely, in a South Shore home with a glazed south wall, we double-check the solar gains before settling on this size.

LKMMA24B1 technical characteristics

  • type: cased evaporator coil;
  • nominal size: 2 tons (24,000 BTU/h);
  • installation positions: upflow, downflow, horizontal left or right;
  • condensate drain: 1-1/4 in. O.D. and 1 in. I.D., outlet on the left and right;
  • leak detection: R-32 refrigerant sensor noted in the LG brochure;
  • matched outdoor units: KUSXB241A and KUSXA301A.

Efficiency: what to read, what to ignore

The coil has no rating on its own. SEER2 and HSPF2 are assigned to the complete system, and the gap between the two match-ups above shows it well: the same coil gives different ratings depending on the outdoor unit. When you are handed a quote, always ask for the system's AHRI number and check that it matches the coil and unit pair being proposed to you.

Maintenance: what to expect as an owner

A properly installed coil needs little attention, but a few habits preserve its performance. Replace or clean the furnace filter on the agreed schedule: a clogged filter reduces airflow, and a coil that receives little air cools less well. Keep the condensate drain clear; if water appears near the furnace in the middle of summer, call us rather than waiting. Finally, have the system checked in the spring, before the first big heat.

The R-32 detection sensor mentioned by LG adds a layer of monitoring, but it does not replace a regular inspection by a technician.

Frequently asked questions about this model

My furnace is not exactly 17-1/2 in. Is that a dealbreaker? No. We measure the unit and, if needed, build an insulated transition on site.

Which installation position is right? The coil is multi-position: upflow, downflow or horizontal, left or right. We choose according to the layout of your mechanical room or attic space.

Who handles the rebate file? We do. We check Hydro-Québec's official list when we prepare your quote and put the file together with you.

Our installation work

AirGreen, a family-owned heating and cooling company based in Montreal, carries out all of the work:

  • measuring the furnace, checking the blower and the electrical panel;
  • installing the coil in the plenum, with an insulated transition if needed and sealed duct connections;
  • installing the outdoor unit, brazed piping, nitrogen test and vacuum;
  • connecting the condensate drain and the thermostat;
  • commissioning, airflow adjustment and a demonstration at your home.

Before buying

  • R-32 refrigerant: the coil is paired with an outdoor unit that uses the same refrigerant, installed with it.
  • The published ratings apply to the certified match-up.
  • The blower must deliver the system's airflow, and the furnace must offer the right width.

LogisVert rebate

The matched LG system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and on your situation: we check it against the official list when we prepare your quote, then put the file together with you.

Request your estimate

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete LG system. Financing is available to spread out the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The LKMMA24B1 sits in the plenum of a furnace or air handler. Connected to the LG KUSXB241A outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with the LG KUSXB241A outdoor unit
Certified systemMatched with the KUSXB241A, the system carries AHRI 216445245.
On your furnaceThe blower, filters and existing ducts are kept.
R-32 refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerLG
ModelLKMMA24B1
TypeCased evaporator coil
LineLKMMA
Nominal size2 tons (24,000 BTU/h)
RefrigerantR-32
Liquid connection3/8 in
Suction connection3/4 in
Dimensions W × H × D17-1/2 × 24 × 21 in
Net weight46 lb
Matched outdoor unitKUSXB241A, KUSXA301A
System AHRI number216445245, 216445264
System SEER2 / HSPF215.2 / 8.5
Model numberLKMMA24B1
03 · Before installing

What to know before installing

  • R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 17-1/2 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
LG
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 2-ton LG coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.