LKMMA60D1: 5 tons and 24-1/2 in. wide, the highest-capacity coil in the LG series
At the top of the LKMMA range, two criteria meet in a single model: the 5-ton capacity and the 24-1/2 in. width. The LKMMA60D1 is a cased evaporator A-coil that runs on R-32 refrigerant, designed for homes with a high load and a furnace of large size. We install it in Montreal, in Laval, in Longueuil, on the North Shore and on the South Shore, always with the LG outdoor unit made for it.
The portrait in numbers
- nominal capacity: 5 tons, or 60,000 BTU/h;
- dimensions W × H × D: 24-1/2 × 34 × 21 in.;
- net weight: 73 lb;
- outdoor partner: KUSXB601A, AHRI number 216445253;
- published system ratings: SEER2 15.5, HSPF2 9.0;
- 52,500 BTU/h of cooling and 56,000 BTU/h of heating at 47 °F.
The coil alone has no rating; these figures describe the complete system. The liquid connection is 3/8 in. and the suction connection 3/4 in.
Why it is not simply "a bigger LKMMA60C1"
The two 5-ton models share the KUSXB601A as their outdoor unit. To tell them apart, you have to compare the container rather than the contents:
- the LKMMA60C1 is 21 in. wide; the LKMMA60D1 is 24-1/2;
- the D is taller and heavier, at 73 lb;
- each model carries its own AHRI number, and therefore its own published ratings: ours is 216445253.
In practice, if the furnace is wide, the D installs on it without a transition; if it is narrower, the C avoids adapting the size. For those whose load justifies only 4 tons, the LKMMA48D1 keeps the 24-1/2 in. width with a lower capacity.
The logistics of a 73 lb cabinet
Before choosing this model, think about the route the cabinet must take: front door, stairs, landing, mechanical room door. We measure this route at the visit. If the passage is narrow, we plan for two technicians, and if needed we temporarily remove a door. The 34 in. height also requires a generous ceiling above the furnace. The mechanical rooms of prestige homes, large cottages or mixed-use buildings often offer this space; small, low basements rarely do.
5 tons: for which homes?
A very large single-level home with wings, a property with high ceilings, a three-level home linked by a single network: these are the cases where a load calculation can end up at 5 tons. In a mid-size home, even an older one, it would be too much. We say so plainly: a properly sized system is better than a big system that starts and stops constantly, removes humidity poorly and ages faster.
For a very large load, some North Shore owners also consider two separate systems, one per zone. We assess that option if the layout of the house lends itself to it.
One last piece of advice
Finally, keep in mind that maximum capacity is not always the best answer: it is the right capacity that gives the most even comfort. We would rather spend an extra hour calculating than correct a poorly chosen system afterwards.
Air distribution, the final judge
At this capacity, everything rests on the network: duct sizes, return air, balancing between floors, tightness of the joints. A blower must deliver the system's airflow, and the ducts must accept it without whistling. We measure and write any necessary modification into the quote.
What the heat pump does for a large home
In summer, the air is cooled and dried in all the rooms served. In winter, the heat pump handles most of the heating in mild weather, and the furnace serves as backup when the outdoor temperature drops below the threshold set with you. The existing ducts, blower and filters stay in place: you add a coil and an outdoor unit, not a new network.
The small habits that extend the system's life
A large system deserves regular maintenance. The furnace filter is replaced on the agreed schedule; a clogged filter slows the air and strains the blower. The pan and the condensate drain are checked every spring, before the first heat wave, because a blocked drain always ends up overflowing at the worst moment. The outdoor unit must be kept clear of snow, leaves and tall grass.
If you hear an unusual noise, if water appears near the furnace or if a room cools less than before, call us: a small adjustment made early often avoids a bigger repair.
What you receive with the quote
- the AHRI number of the proposed system, so you can compare on an honest basis;
- the detail of the plenum, piping and electrical connection work;
- any modifications to the ducts or the blower, if there are any;
- the status of rebate eligibility, checked against the official list.
Technical characteristics in detail
- type: cased evaporator coil, LKMMA range;
- condensate drain: 1-1/4 in. O.D. and 1 in. I.D., left and right;
- positions: upflow, downflow, horizontal left or right;
- leak detection: R-32 refrigerant sensor according to the LG brochure.
The AirGreen installation, from plenum to commissioning
AirGreen, a family-owned heating and cooling company based in Montreal, carries out this type of job from start to finish:
- measuring the furnace, checking the blower and the electrical panel;
- installing the coil in the plenum, a transition built on site if the width requires it, sealing the duct connections;
- outdoor unit on a pad or bracket, brazed piping, nitrogen leak test, vacuum;
- connecting the condensate drain and the thermostat;
- commissioning, airflow adjustment and an explanation of how the system works.
To check before choosing
- R-32: the coil pairs with an outdoor unit using the same refrigerant, installed at the same time.
- The ratings belong to the certified system.
- The 24-1/2 in. width, the 34 in. height, the blower and the access route are confirmed during the visit.
LogisVert rebate
The matched LG system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and on your situation: we check it against the official list when we prepare your quote and put the file together with you.
Request your estimate
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete LG system. Financing is available to spread out the cost of the project.
The heat pump coil for your furnace
The LKMMA60D1 sits in the plenum of a furnace or air handler. Connected to the LG KUSXB601A outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the LG KUSXB601A outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 24-1/2 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
LGSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 5-ton LG coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.