LG LKMMA48D1 Evaporator A-Coil | 4 Tons
The LG LKMMA48D1 4-ton R-32 cased coil sits on your furnace and, matched with the LG KUSXA482A outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberLKMMA48D1
514 316-2973 · sales@airgreen.ca
Quick facts
LKMMA48D1: the large 24-1/2 in. LG cabinet for a 4-ton system
Some mechanical rooms look like machine rooms: a large furnace, space above it, ducts of generous size. For these installations, LG offers the LKMMA48D1, a cased evaporator A-coil of 4 tons, 24-1/2 in. wide and 34 in. high. It runs on R-32 refrigerant and pairs with the KUSXA482A or the KUSXB481A. We install it in Montreal, in Laval, in Longueuil, on the North Shore and on the South Shore.
A size to measure before dreaming about it
At 24-1/2 in. wide, 34 in. high and 21 in. deep, this cabinet is one of the most imposing in the series; it weighs 73 lb net. It is not a model you order blind. Here is what we measure at your home:
- the width of the furnace, which must be close to 24-1/2 in., otherwise a transition becomes necessary;
- the clear height above the unit, since a 34 in. cabinet requires real clearance;
- the route to the mechanical room, with the 73 lb weight to manoeuvre on the stairs;
- the path of the piping to the outdoor unit.
In many homes, these measurements are enough to decide between this model and the LKMMA48C1, which has the same capacity but is narrower.
The published ratings for this match-up
- KUSXA482A, AHRI number 216445262: 45,500 BTU/h of cooling, 50,000 BTU/h of heating at 47 °F, SEER2 16.1, HSPF2 9.1;
- KUSXB481A, AHRI number 216445251: 45,500 BTU/h of cooling, 48,000 BTU/h of heating at 47 °F, SEER2 15.5, HSPF2 8.5.
With the KUSXA482A, this coil reaches SEER2 16.1 and HSPF2 9.1, the highest published values among the LKMMA coil match-ups that LG has certified. That is an interesting indication, but keep in mind that only the complete system carries the rating: the coil has none on its own.
The D versus the C, at equal capacity
The LKMMA48C1 also offers 4 tons, with a 21 in. width and three possible match-ups. The LKMMA48D1 is wider at 24-1/2 in., taller, heavier, and limited to two match-ups. What matters, in the end, is the furnace: if yours is wide, the D sits on it naturally; if it is more modest, the C avoids a bulky transition.
The LKMMA60D1 has the same 24-1/2 in. width and goes up to 5 tons with the KUSXB601A. The two D models therefore resemble each other in size and differ in capacity.
What a large cabinet brings, without exaggeration
A larger cabinet offers more frontal surface to the air passing through the fins. There is nothing magic about it: the quality of air distribution depends mostly on the ducts and the blower. But in a home where the network is generous, a coil that matches the network avoids creating a bottleneck at the centre of the system.
Where the heat pump's heat makes the difference
In a large home heated with electricity, the heat pump absorbs most of the heating season when the weather is moderate. The furnace stays in reserve and takes over below the threshold that we set with you. In summer, the same coil cools and dries the air on both floors through the ducts already in place, with no window units.
The transition: when the furnace is not the right width
Many owners learn at this point that a coil does not need to match the furnace exactly. An insulated sheet-metal transition, built on site, connects the two sizes. Done well, it is airtight, quiet and invisible once the mechanical room is closed up. Done badly, it leaks and whistles. That is why we design it after measuring, seal every joint, and insulate the whole assembly to avoid condensation on the cold sheet metal.
If your furnace is clearly narrower than 24-1/2 in., it is often simpler, and cleaner, to choose a coil of a closer width rather than multiply the adaptations.
Installation day
A 73 lb cabinet is not placed at arm's length. Two technicians lift the coil, centre it on the furnace, check that it is plumb and that the pan slopes correctly, then connect the condensate drain to the most practical outlet, left or right. Next come the refrigerant connections, brazed with nitrogen flowing through the pipes to keep the inside clean, then the leak test and the vacuum. Each step is checked before moving to the next: a small defect caught early costs a few minutes; the same defect after start-up can cost a day.
We finish by explaining the thermostat, the furnace changeover threshold and routine maintenance, such as replacing the filters.
For whom does this model make the most sense?
- the owner of a large home whose furnace offers a cabinet of generous width;
- the one who wants a 4-ton with the option of relying on the KUSXA482A and its published ratings;
- the owner who already plans regular maintenance and an accessible mechanical room.
If your furnace is narrower, or if your home is smaller, the 21 in. or 17-1/2 in. wide models will probably be better suited.
Technical characteristics
- model: LKMMA48D1, LKMMA range;
- nominal size: 4 tons (48,000 BTU/h);
- 3/8 in. liquid connection, 3/4 in. suction connection;
- condensate drain of 1-1/4 in. O.D. and 1 in. I.D., left and right;
- installation positions: upflow, downflow, horizontal left or right;
- R-32 detection sensor according to the LG brochure.
Installation at your home by AirGreen
A family-owned heating and cooling company based in Montreal for more than fifteen years, AirGreen takes care of the whole job:
- measuring the furnace, checking the blower and the electrical panel;
- installing the coil in the plenum, with a transition built on site if needed, and sealing the duct connections;
- outdoor unit on a pad or bracket, brazed piping, nitrogen leak test, vacuum;
- connecting the condensate drain and the thermostat;
- commissioning, airflow adjustment, explanation of how the system works.
To check before choosing
- The coil uses R-32: it pairs with an outdoor unit using the same refrigerant, installed at the same time.
- The ratings apply to the certified match-up, not to the coil alone.
- The blower must deliver the system's airflow and the space must accommodate 24-1/2 in. by 34 in.
LogisVert rebate
The matched LG system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and on your situation: we check it against the official list when we prepare your quote and put the file together with you.
Request your estimate
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete LG system. Financing is available to spread out the cost of the project.
The heat pump coil for your furnace
The LKMMA48D1 sits in the plenum of a furnace or air handler. Connected to the LG KUSXA482A outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the LG KUSXA482A outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 24-1/2 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
LGSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 4-ton LG coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.