GENERAL AIRSTAGE Simple 2-Wire Remote Control without Mode Selection – UTY-RHRY
The GENERAL AIRSTAGE wall remote designed for hospitality: occupants set the temperature but cannot change the mode.
AirGreen codeAG-AC-071
514 316-2973 · sales@airgreen.ca
Quick facts
The GENERAL AIRSTAGE UTY-RHRY is the simple 2-wire remote the manufacturer designs for the hotel industry. The name changed, not the product: on January 1, 2026, Fujitsu General Limited became GENERAL Inc., and the model numbers stayed the same. The GENERAL UTY-RHRY is the same part sold under the Fujitsu AIRSTAGE brand.
Occupants can turn the unit on, turn it off and set the temperature, but the operating mode stays out of their reach: the manager sets it.
A mode set in advance, fewer service calls
It is a classic scenario in a hotel, a residence or a managed rental unit: in the depths of winter, an occupant switches to cooling, ends up uncomfortable and complains. The UTY-RHRY cuts that short, since the mode is chosen a single time, for good. The temperature sensor sits in the remote and adjusts in 1 °F steps, while the backlit LCD screen is easy to read in a dark room.
Manufacturer technical data
- 12 V DC power supplied by the indoor unit, 0.3 W at most
- Non-polarized cable with 2 shielded, twisted conductors, 22 to 16 AWG
- Groups of up to 16 indoor units and 4 remotes
- 120 × 75 × 19 mm format, 120 g, operating range of 0 to 46 °C
Compatibility and newer version
The manufacturer offers it as an option for its R-32 AMUH air handlers, ARUH ducted units, ACUH and AUUH cassettes and ABUH suspended units, sold under both names, GENERAL and Fujitsu. GENERAL also has a newer version, the UTY-RHRYZ1, which additionally provides refrigerant leak and sensor replacement alerts. If occupants need to be able to choose the mode, look instead to the UTY-RSRY.
AirGreen equips your rooms
Hotels, residences, rental buildings: we equip them in Montreal, Laval, Longueuil, on the South Shore and on the North Shore, under RBQ licence 5645-9605-01. For a quote or an availability check, call 514 316-2973 or write to sales@airgreen.ca, specifying the indoor unit model and the quantity you need.
For guest rooms and places where the mode stays fixed
In a hotel room or a managed unit, the manager sets the mode; occupants only adjust the temperature.
- Hotel and residence rooms
- Rental units and centrally managed offices
- AIRSTAGE (GENERAL or Fujitsu) R-32 indoor units that list it as an option
- Replacing an existing UTY-RHRY
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- Non-polar 2-core shielded twisted pair, 22 to 16 AWG.
- Mount it away from direct sun, air outlets and heat sources: the sensor is in the housing.
- The manufacturer also offers the UTY-RHRYZ1, which adds refrigerant leak alerts.
- Send us the indoor unit model number to confirm compatibility.
You may also need
GENERAL AIRSTAGE 2-Wire Simple Remote Control with Mode Selection – UTY-RSRY
GENERAL AIRSTAGE Simple Wired Remote Control with Leak Alerts – UTY-RSRYZ1
GENERAL AIRSTAGE KAGAMI Wired Controller – UTY-RVRU
GENERAL AIRSTAGE UTY-TFSXJ4 Wi-Fi Module for Non-Wall-Mounted Unit (UART)
Fujitsu Leak Detection System Accessory – UTYSGZU
GENERAL AIRSTAGE Leak Detection System Accessory – UTYSGZU
Hitachi 5-Wire Adapter for 24 V Thermostat – C3STAT01
Hitachi C1STAT01 5-Wire Thermostat Adapter (airHome)Original partsSee all
Frequently asked questions
Is my unit compatible?
The manufacturer lists it on the submittal sheets of its R-32 AMUH air handlers, ARUH ducted units, ACUH and AUUH cassettes and ABUH ceiling-suspended units. Send us your model number and we confirm.
How is it different from the UTY-RSRY?
Same housing and wiring. The UTY-RSRY lets you change the mode, the UTY-RHRY does not.
Can a group have several remotes?
Yes, up to 4 remotes for a group of up to 16 indoor units.
Can you install it?
Yes. We mount and wire it, room by room if needed, everywhere in Greater Montréal.
Simple control for guest rooms and shared spaces
Tell us the size and the quantity: we confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on October 7, 2026.