GENERAL AIRSTAGE Simple 2-Wire Remote Control without Mode Selection – UTY-RHRY

In stock

The GENERAL AIRSTAGE wall remote designed for hospitality: occupants set the temperature but cannot change the mode.

AirGreen codeAG-AC-071

No modeoccupants cannot change the mode
16 unitsper group
120 gcompact housing
HospitalityGenuine part
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

AirGreen codeAG-AC-071
BrandGENERAL (formerly Fujitsu General)
Part no.UTY-RHRY
Manufacturer nameSimple Wired Remote (Without Mode Function)
Wiring2-wire
Units controlledUp to 16

The GENERAL AIRSTAGE UTY-RHRY is the simple 2-wire remote the manufacturer designs for the hotel industry. The name changed, not the product: on January 1, 2026, Fujitsu General Limited became GENERAL Inc., and the model numbers stayed the same. The GENERAL UTY-RHRY is the same part sold under the Fujitsu AIRSTAGE brand.

Occupants can turn the unit on, turn it off and set the temperature, but the operating mode stays out of their reach: the manager sets it.

A mode set in advance, fewer service calls

It is a classic scenario in a hotel, a residence or a managed rental unit: in the depths of winter, an occupant switches to cooling, ends up uncomfortable and complains. The UTY-RHRY cuts that short, since the mode is chosen a single time, for good. The temperature sensor sits in the remote and adjusts in 1 °F steps, while the backlit LCD screen is easy to read in a dark room.

Manufacturer technical data

  • 12 V DC power supplied by the indoor unit, 0.3 W at most
  • Non-polarized cable with 2 shielded, twisted conductors, 22 to 16 AWG
  • Groups of up to 16 indoor units and 4 remotes
  • 120 × 75 × 19 mm format, 120 g, operating range of 0 to 46 °C

Compatibility and newer version

The manufacturer offers it as an option for its R-32 AMUH air handlers, ARUH ducted units, ACUH and AUUH cassettes and ABUH suspended units, sold under both names, GENERAL and Fujitsu. GENERAL also has a newer version, the UTY-RHRYZ1, which additionally provides refrigerant leak and sensor replacement alerts. If occupants need to be able to choose the mode, look instead to the UTY-RSRY.

AirGreen equips your rooms

Hotels, residences, rental buildings: we equip them in Montreal, Laval, Longueuil, on the South Shore and on the North Shore, under RBQ licence 5645-9605-01. For a quote or an availability check, call 514 316-2973 or write to sales@airgreen.ca, specifying the indoor unit model and the quantity you need.

01 · What it is for

For guest rooms and places where the mode stays fixed

In a hotel room or a managed unit, the manager sets the mode; occupants only adjust the temperature.

  • Hotel and residence rooms
  • Rental units and centrally managed offices
  • AIRSTAGE (GENERAL or Fujitsu) R-32 indoor units that list it as an option
  • Replacing an existing UTY-RHRY
No mode accessThe operating mode is not offered to occupants.
Built-in sensorRoom temperature is read in the remote, adjustable in 1 °F steps.
GroupsUp to 16 units and 4 remotes per group.
Compatible with
AMUH24KUASAMUH48KUASARUH12KUASACUH12KUASACUH18KUASAUUH48KUASABUH36KUAS
Per the manufacturer. Send us your unit’s model number and we confirm before ordering.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

BrandGENERAL (formerly Fujitsu General)
TypeSimple wired remote, without mode selection
Part no.UTY-RHRY
SensorBuilt-in room temperature, 1 °F adjustment
DisplayLarge backlit LCD
Power12 V DC, 0.3 W max.
WiringNon-polar 2-core shielded twisted pair, 22 to 16 AWG
Units per groupUp to 16 indoor units
Remotes per groupUp to 4
Operating temperature0 to 46 °C (32 to 114 °F)
Storage temperature-20 to 70 °C (-4 to 158 °F)
Dimensions120 × 75 × 19 mm (4-3/4 × 2-15/16 × 3/4 in)
Weight120 g (4 oz)
AirGreen codeAG-AC-071
03 · Before installing

What to know before installing

  • Non-polar 2-core shielded twisted pair, 22 to 16 AWG.
  • Mount it away from direct sun, air outlets and heat sources: the sensor is in the housing.
  • The manufacturer also offers the UTY-RHRYZ1, which adds refrigerant leak alerts.
  • Send us the indoor unit model number to confirm compatibility.
04 · Goes with

You may also need

Same category
Original parts
See all
05 · Questions

Frequently asked questions

Is my unit compatible?

The manufacturer lists it on the submittal sheets of its R-32 AMUH air handlers, ARUH ducted units, ACUH and AUUH cassettes and ABUH ceiling-suspended units. Send us your model number and we confirm.

How is it different from the UTY-RSRY?

Same housing and wiring. The UTY-RSRY lets you change the mode, the UTY-RHRY does not.

Can a group have several remotes?

Yes, up to 4 remotes for a group of up to 16 indoor units.

Can you install it?

Yes. We mount and wire it, room by room if needed, everywhere in Greater Montréal.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

Simple control for guest rooms and shared spaces

Tell us the size and the quantity: we confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 7, 2026.