2-Zone Heat Pump DURASTAR Standard | 55,000 BTU - R410A

In stock
SKU: DRA5U55M1B
55,000BTU/h · 2 heads
−25 °Cheats down to
Optional Wi-FiR-410AUp to 5 heads
Talk to a technician · 514 316-2973
Outdoor unit DRA5U55M1BPossible indoor models DRAC09F1A, DRAC12F1A, DRAC18F1A, DRAC24F1A, DRAC24F1B, DRAD09F1A, DRAD12F1A, DRAD18F1A, DRAD24F1A, DRAF18F1A, DRAF24F1A, DRAL06F1A, DRAL09F1A, DRAL12F1A, DRAL18F1A, DRAM18F1A, DRAM24F1A, DRAM30S1A, DRAM36S1A, DRAM48S1A, DRAM60S1A, DRAS12F1A, DRAS12F1BAHRI 210568208
In short

The Durastar Standard R410A 55 000 multi-zone heat pump heats and cools 2 rooms with a single outdoor unit. it delivers 36,400 BTU/h at −8 °C, heats down to −25 °C. Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.

01 · The verdict in 10 seconds

2 rooms, one outdoor unit.

Compared with the 13 multi-zone systems of 55,000 BTU we sell. Every number on this page carries its source.

NEEP 402875AHRI 210568208
!Good to know: heats down to −25 °CRank 10 of 13; class median: −30 °C.
36,400BTU/h certified at −8 °C
−25 °Cstill heating
2 → 5heads, on the same unit
2.56COP at −8 °C
02 · The machine

The parts that make a multi-zone system.

Tap a part to learn more.

DRA5U55M1B

Outdoor unit

One compressor for the whole house. It supplies up to 5 heads and modulates from 20,000 to 37,000 BTU/h depending on what the rooms call for (NEEP).

03 · How it works

Turn rooms on and off. Watch the power being shared.

One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.

04 · My plan

Tell us your rooms. We tell you if this size is enough.

Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide, the real calculation is done room by room at your home.

05 · The series

The whole series at a glance: find the box that fits you.

Each box is a product: the outdoor unit’s size, and the number of heads.

Outdoor2 zones3 zones4 zones5 zones
18,000BTU
2
28,000BTU
23
36,000BTU
234
48,000BTU
2345
55,000BTU
Here345

Durastar Standard R410A 55 000 · 2 zones

36,400 BTU/h
at −8 °C

Up to 5 heads on this outdoor unit. Tap another box to see that size.

06 · Deep cold

At −15 °C, it still delivers 60 % of its rated capacity.

Tap a temperature: certified capacity, efficiency and the cost of one hour of heating.

It slows down, it speeds up: the certified modulation range

Light bar: from minimum to maximum capacity. Dark mark: the rated value.

+8.3 °C
20,000 → 60,000 BTU/h
-8 °C
18,000 → 37,000 BTU/h
-15 °C
13,000 → 33,200 BTU/h
Source: NEEP, minimum, rated and maximum ratings at 47, 17 and 5 °F.
07 · The bill

At every temperature, cheaper than baseboards.

Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.

08 · Efficiency

The official ratings, on the same scales as before.

SEER2, HSPF2 and EER2 come from the AHRI certification. The mark shows the median of the same-size multi-zone systems we sell.

SEER2 · seasonal cooling20.2
Scale 1 – 30Median: 20.2
Rank 6 (tied) of 13 in its class.
HSPF2 · seasonal heating9.6
Scale 1 – 15Median: 9.6
Rank 6 (tied) of 13 in its class.
EER2 · cooling in peak heat10.5
Scale 1 – 20Median: 10.5
Rank 6 (tied) of 13 in its class.
COP at −15 °C1.8
Scale 0 – 4Median: 1.8
Rank 6 (tied) of 13 in its class.
09 · Report card

Where it ranks among same-size multi-zone systems.

Compared with the 13 multi-zone systems of 55,000 BTU we sell. Weaknesses too, said plainly.

10 · Multi-zone or wall units

One multi-zone or several wall units? Both sides, honestly.

This multi-zone2 wall units
On the wall1 outdoor unit2 outdoor units
Electrical1 dedicated circuitOne circuit per unit
CapacityShared between roomsReserved for each room
If the outdoor unit stopsEvery zone stopsOnly one room
ModesSame mode everywhereEach room chooses
LogisVertPer the listDepends on each model

We compare both options on your floor plan during the estimate.

11 · Installation

What to know before installing a multi-zone system.

Dimensions, wiring and lines, drawn. Then our six steps.

The outdoor unit, dimensioned

52.50 in
DRA5U55M1BDepth 16.31 in
37.50 in
Dimensions: product sheet (W × D × H).

One circuit for the whole house

Electrical panel
Load calculation before the quote
60 A max. breaker
MCA 40 A · 220 V
Outdoor unit
Head 1
Head 2
Our RBQ licence covers electrical work (subclass 16).
01Room-by-room visit and surveyWe measure each zone and note insulation and windows. The on-site estimate is free.
02Heads and line layoutOne pair of lines per head.
03Outdoor unit baseAbove the snow line, away from the neighbours’ bedroom windows.
04Exposed, finished linesLines under line covers, no work inside the walls.
05Dedicated circuit220 V, MCA 40 A, 60 A protection. The panel load calculation is done before the quote.
06Commissioning, zone by zoneEach head is tested and the controls set up.
12 · Sound

Published sound levels, on one scale.

We use the outdoor figure to choose where the unit goes.

36
43
62
36
61
20 dB(A)3040506070
36 Reference head, lowest speed43 Reference head, highest speed36 Class indoor median62 Outdoor unit61 Class outdoor median
Values in dB(A). Indoor values are those of the sheet’s reference head; each head has its own, confirmed for the chosen model. Municipal noise by-laws vary by borough.
13 · What sets it apart

What is particular about this machine.

Only facts published by ENERGY STAR, NEEP or the manufacturer.

20,000BTU/h at low speedMinimum certified capacity (NEEP): it slows down instead of stopping when a single room calls.
150 WBase pan heaterHeater in the outdoor unit’s base pan, against ice (NEEP).
14 · Specifications

Every number, and where it comes from.

Each line carries its source; a line with no published value is not shown.

Performance
Cooling capacity (size)55,000 BTUSheet
Certified cooling at 35 °C55,000 BTU/hNEEP
SEER2 (seasonal cooling efficiency)20.2AHRI
EER2 (instant cooling efficiency)10.5AHRI
HSPF2 (seasonal heating efficiency, region IV)9.6AHRI
HSPF2, region V (coldest)7NEEP
Heating
Capacity at +8.3 °C55,000 BTU/h · COP 3.14NEEP
Capacity at −8 °C36,400 BTU/h · COP 2.56NEEP
Capacity at −15 °C33,200 BTU/h · COP 1.8NEEP
Capacity at -15 °C (max.)33,200 BTU/h · COP 1.8Sheet
Modulation range20,000 – 37,000 BTU/hNEEP
Heats down to−25 °CSheet
Zones and heads
Zones on this product2 Zones (Dual Zone)Sheet
Maximum zones5 ZonesSheet
Possible indoor modelsDRAC09F1A, DRAC12F1A, DRAC18F1A, DRAC24F1A, DRAC24F1B, DRAD09F1A, DRAD12F1A, DRAD18F1A, DRAD24F1A, DRAF18F1A, DRAF24F1A, DRAL06F1A, DRAL09F1A, DRAL12F1A, DRAL18F1A, DRAM18F1A, DRAM24F1A, DRAM30S1A, DRAM36S1A, DRAM48S1A, DRAM60S1A, DRAS12F1A, DRAS12F1BSheet
Indoor dimensions (W × D × H)22.44 x 22.44 x 10.24 inSheet
Vertical louversAutoSheet
Horizontal louversManuel / ManualSheet
Airflow (reference head)379 CFMSheet
Indoor sound (reference head)36 – 43 dB(A)Sheet
Installation
Outdoor unit (W × D × H)37.50 x 16.31 x 52.50 inSheet
Outdoor sound62 dB(A)Sheet
Base pan heater150 WNEEP
Electrical
Voltage220 VSheet
MCA (minimum circuit ampacity)40 ASheet
MOP (maximum overcurrent protection)60 ASheet
RefrigerantR-410ASheet
Wi-FiOptionalSheet
Certifications and warranty
AHRI210568208AHRI
Warranty (compressor · parts · labour)10 yrs · 10 yrs · 6 yrsSheet
AirGreen extended warrantyPossibleSheet
15 · Official brochures

The manufacturer’s documentation, as PDF.

16 · Description

Everything we have written about this system.

Un garage devenu pièce habitable, traité comme une zone à part entière

Un garage converti ne se comporte jamais comme le reste d'un bungalow de Rivière-des-Prairies : dalle sur sol, plafond bas, un mur entier exposé et aucun conduit qui s'y rende. Quand l'entretien annuel révèle que le système en place arrive en fin de vie, le moment est venu de cesser de la traiter comme une annexe. La Thermopompe 2-Zones DURASTAR Standard | 55 000 BTU - R410A le permet : une tête pour l'aire de vie d'origine, une autre pour la pièce ajoutée, sur un seul condenseur.

Ses cotes sont de 20,2 SEER2, 10,5 EER2 et 9,6 HSPF2, avec un chauffage inscrit jusqu'à -25 °C. Ce système ne figure pas sur la liste des thermopompes admissibles au programme LogisVert d'Hydro-Québec en vigueur, ce qui explique la valeur de 0 $ affichée dans la fiche technique.

Ce que le certificat inscrit pour ce condenseur

  • À -8 °C : 36 400 BTU/h, avec un COP de 2,56
  • À -15 °C : 33 200 BTU/h, avec un COP de 1,80
  • Limite de chauffage inscrite : -25 °C
  • Unité extérieure : 62 dB(A)

Ces chiffres sont ceux du certificat AHRI 210568208, tels que publiés par le NEEP. Le débit de 379 PCM et le niveau sonore de 36 à 43 dB(A) valent pour la tête que la fiche prend comme référence, non pour chacun des modèles raccordables.

L'été dans une pièce ajoutée au bungalow

Une pièce sur dalle avec un grand mur exposé réclame du froid avant le reste de la maison. Avec deux zones, chaque tête garde sa consigne, et couper celle de la pièce ajoutée quand on ne s'y trouve pas laisse l'autre poursuivre son cycle. La cote de 20,2 SEER2 se mesure sur une saison complète : c'est un rendement moyen, pas la performance d'une journée de canicule.

LogisVert : ce que veut dire le 0 $ de la fiche

Le 0 $ ne traduit pas un défaut de l'appareil : la liste d'Hydro-Québec retient des combinaisons précises de condenseur et de têtes, et celle-ci n'y est pas. Pour un propriétaire d'une habitation existante, le format voisin de la même série, la Thermopompe 2-Zones DURASTAR Standard | 48 000 BTU - R410A, y figure pour sa part. Nous mettons les deux côte à côte avant la signature, selon la liste en vigueur à la date d'installation.

Dimensionner chaque zone du bungalow avant de percer

Répartir la capacité entre deux têtes

Le condenseur DRA5U55M1B dessert deux zones qui puisent dans la même réserve : ce que prend l'une n'est plus disponible pour l'autre. On établit donc le besoin de l'aire de vie et celui de la pièce ajoutée avant de retenir les formats. DuraStar publie les ensembles intérieurs compatibles, parmi lesquels DRAS12F1B, DRAL12F1A, DRAC18F1A et DRAM24F1A. Chaque tête reste commandée séparément, de sorte qu'une zone fermée n'immobilise pas la seconde.

Si une des deux zones passe par un ensemble gainable

Une pièce sur dalle accepte mal une tête en hauteur, et un ensemble gainable comme le DRAD09F1A ou le DRAD18F1A devient parfois le bon choix. Le réseau de conduits se dimensionne alors pour la tête retenue, pas pour l'ensemble du système : parcours court, grilles suffisantes, accès au filtre. Chaque tête conserve son propre jeu de lignes jusqu'au condenseur, et nos installations demeurent entièrement apparentes, sans travaux à l'intérieur des murs.

L'alimentation électrique du bungalow

Le condenseur demande 220 V, un MCA de 40 A et un disjoncteur de 60 A sur un circuit dédié. Un bungalow dont le garage a été converti a souvent vu s'ajouter plinthes et prises sans que l'entrée soit revue. Nous faisons le calcul de charge avant de proposer l'installation, et une mise à niveau du panneau figure dans la soumission, jamais dans la facture finale.

AirGreen, du relevé jusqu'à l'entretien annuel

Entreprise familiale depuis plus de quinze ans, nous intervenons à Montréal, à Laval, à Longueuil, sur la Rive-Nord et sur la Rive-Sud, avec les licences RBQ en ventilation, en réfrigération et en électricité. L'évaluation à domicile est gratuite et rien n'est signé sur place. Les filtres des deux têtes se rincent aux deux semaines et l'entretien CVAC annuel couvre serpentins, écoulement du condensat et raccords électriques ; notre service de nettoyage s'en charge, et nos options de financement couvrent le reste du projet.

Réservez votre estimation gratuite pour la Thermopompe 2-Zones DURASTAR Standard | 55 000 BTU - R410A. Nous mesurons la pièce convertie, comparons ce format avec le 48 000 BTU inscrit à LogisVert et validons la charge du panneau.

Garantie : 10 ans sur le compresseur, 10 ans sur les pièces et 6 ans sur la main-d’œuvre, directement du distributeur.

17 · Questions

What people ask us about multi-zone systems.

Can I heat one room and cool another at the same time?

No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.

What happens when every room calls for heat?

They share the outdoor unit’s capacity: 36,400 BTU/h at −8 °C, 33,200 at −15 °C.

How many heads can I connect?

Up to 5 on this outdoor unit. This product is configured for 2 heads.

Down to what temperature does it heat?

Down to −25 °C.

Is it noisy?

Indoors, the reference head goes down to 36 dB(A). Outdoors, 62 dB(A): we place the unit away from bedroom windows.

Why a multi-zone instead of several wall units?

One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.

What does the warranty cover?

Our sheet lists 10 years on the compressor and 10 years on parts. AirGreen extended warranty: possible.

AirGreen

A multi-zone system is planned room by room. At your home.

We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.

RBQ 5645-9605-01Ventilation 15.8, refrigeration 15.10, electrical 16
We handle the circuitOur licence covers the electrical work
Beware of scamsHydro-Québec does no phone or door-to-door solicitation for LogisVert
Sources checked on October 1, 2026.NEEP, Cold Climate Air Source Heat Pump List, product 402875 (AHRI 210568208): capacities and COP, modulation, SEER2, EER2, HSPF2.Costs: Hydro-Québec Rate D, 11.142 ¢/kWh (second tier, since 1 April 2026). Amounts shown are estimates; only the responsible bodies confirm the grant awarded.