4-Zone Heat Pump DURASTAR Standard | 55,000 BTU - R410A

In stock
SKU: DRA5U55M1B
55,000BTU/h · 4 heads
−25 °Cheats down to
Optional Wi-FiR-410AUp to 5 heads
Talk to a technician · 514 316-2973
Outdoor unit DRA5U55M1BPossible indoor models DRAC09F1A, DRAC12F1A, DRAC18F1A, DRAC24F1A, DRAC24F1B, DRAD09F1A, DRAD12F1A, DRAD18F1A, DRAD24F1A, DRAF18F1A, DRAF24F1A, DRAL06F1A, DRAL09F1A, DRAL12F1A, DRAL18F1A, DRAM18F1A, DRAM24F1A, DRAM30S1A, DRAM36S1A, DRAM48S1A, DRAM60S1A, DRAS12F1A, DRAS12F1BAHRI 210568208
In short

The Durastar Standard R410A 55 000 multi-zone heat pump heats and cools 4 rooms with a single outdoor unit. it delivers 36,400 BTU/h at −8 °C, heats down to −25 °C. Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.

01 · The verdict in 10 seconds

4 rooms, one outdoor unit.

Compared with the 13 multi-zone systems of 55,000 BTU we sell. Every number on this page carries its source.

NEEP 402875AHRI 210568208
!Good to know: heats down to −25 °CRank 10 of 13; class median: −30 °C.
36,400BTU/h certified at −8 °C
−25 °Cstill heating
4 → 5heads, on the same unit
2.56COP at −8 °C
02 · The machine

The parts that make a multi-zone system.

Tap a part to learn more.

DRA5U55M1B

Outdoor unit

One compressor for the whole house. It supplies up to 5 heads and modulates from 20,000 to 37,000 BTU/h depending on what the rooms call for (NEEP).

03 · How it works

Turn rooms on and off. Watch the power being shared.

One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.

04 · My plan

Tell us your rooms. We tell you if this size is enough.

Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide, the real calculation is done room by room at your home.

05 · The series

The whole series at a glance: find the box that fits you.

Each box is a product: the outdoor unit’s size, and the number of heads.

Outdoor2 zones3 zones4 zones5 zones
18,000BTU
2
28,000BTU
23
36,000BTU
234
48,000BTU
2345
55,000BTU
23Here5

Durastar Standard R410A 55 000 · 4 zones

36,400 BTU/h
at −8 °C

Up to 5 heads on this outdoor unit. Tap another box to see that size.

06 · Deep cold

At −15 °C, it still delivers 60 % of its rated capacity.

Tap a temperature: certified capacity, efficiency and the cost of one hour of heating.

It slows down, it speeds up: the certified modulation range

Light bar: from minimum to maximum capacity. Dark mark: the rated value.

+8.3 °C
20,000 → 60,000 BTU/h
-8 °C
18,000 → 37,000 BTU/h
-15 °C
13,000 → 33,200 BTU/h
Source: NEEP, minimum, rated and maximum ratings at 47, 17 and 5 °F.
07 · The bill

At every temperature, cheaper than baseboards.

Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.

08 · Efficiency

The official ratings, on the same scales as before.

SEER2, HSPF2 and EER2 come from the AHRI certification. The mark shows the median of the same-size multi-zone systems we sell.

SEER2 · seasonal cooling20.2
Scale 1 – 30Median: 20.2
Rank 6 (tied) of 13 in its class.
HSPF2 · seasonal heating9.6
Scale 1 – 15Median: 9.6
Rank 6 (tied) of 13 in its class.
EER2 · cooling in peak heat10.5
Scale 1 – 20Median: 10.5
Rank 6 (tied) of 13 in its class.
COP at −15 °C1.8
Scale 0 – 4Median: 1.8
Rank 6 (tied) of 13 in its class.
09 · Report card

Where it ranks among same-size multi-zone systems.

Compared with the 13 multi-zone systems of 55,000 BTU we sell. Weaknesses too, said plainly.

10 · Multi-zone or wall units

One multi-zone or several wall units? Both sides, honestly.

This multi-zone4 wall units
On the wall1 outdoor unit4 outdoor units
Electrical1 dedicated circuitOne circuit per unit
CapacityShared between roomsReserved for each room
If the outdoor unit stopsEvery zone stopsOnly one room
ModesSame mode everywhereEach room chooses
LogisVertPer the listDepends on each model

We compare both options on your floor plan during the estimate.

11 · Installation

What to know before installing a multi-zone system.

Dimensions, wiring and lines, drawn. Then our six steps.

The outdoor unit, dimensioned

52.50 in
DRA5U55M1BDepth 16.31 in
37.50 in
Dimensions: product sheet (W × D × H).

One circuit for the whole house

Electrical panel
Load calculation before the quote
60 A max. breaker
MCA 40 A · 220 V
Outdoor unit
Head 1
Head 2
Head 3
Head 4
Our RBQ licence covers electrical work (subclass 16).
01Room-by-room visit and surveyWe measure each zone and note insulation and windows. The on-site estimate is free.
02Heads and line layoutOne pair of lines per head.
03Outdoor unit baseAbove the snow line, away from the neighbours’ bedroom windows.
04Exposed, finished linesLines under line covers, no work inside the walls.
05Dedicated circuit220 V, MCA 40 A, 60 A protection. The panel load calculation is done before the quote.
06Commissioning, zone by zoneEach head is tested and the controls set up.
12 · Sound

Published sound levels, on one scale.

We use the outdoor figure to choose where the unit goes.

36
43
62
36
61
20 dB(A)3040506070
36 Reference head, lowest speed43 Reference head, highest speed36 Class indoor median62 Outdoor unit61 Class outdoor median
Values in dB(A). Indoor values are those of the sheet’s reference head; each head has its own, confirmed for the chosen model. Municipal noise by-laws vary by borough.
13 · What sets it apart

What is particular about this machine.

Only facts published by ENERGY STAR, NEEP or the manufacturer.

20,000BTU/h at low speedMinimum certified capacity (NEEP): it slows down instead of stopping when a single room calls.
150 WBase pan heaterHeater in the outdoor unit’s base pan, against ice (NEEP).
14 · Specifications

Every number, and where it comes from.

Each line carries its source; a line with no published value is not shown.

Performance
Cooling capacity (size)55,000 BTUSheet
Certified cooling at 35 °C55,000 BTU/hNEEP
SEER2 (seasonal cooling efficiency)20.2AHRI
EER2 (instant cooling efficiency)10.5AHRI
HSPF2 (seasonal heating efficiency, region IV)9.6AHRI
HSPF2, region V (coldest)7NEEP
Heating
Capacity at +8.3 °C55,000 BTU/h · COP 3.14NEEP
Capacity at −8 °C36,400 BTU/h · COP 2.56NEEP
Capacity at −15 °C33,200 BTU/h · COP 1.8NEEP
Capacity at -15 °C (max.)33,200 BTU/h · COP 1.8Sheet
Modulation range20,000 – 37,000 BTU/hNEEP
Heats down to−25 °CSheet
Zones and heads
Zones on this product4 Zones (Quad Zone)Sheet
Maximum zones5 ZonesSheet
Possible indoor modelsDRAC09F1A, DRAC12F1A, DRAC18F1A, DRAC24F1A, DRAC24F1B, DRAD09F1A, DRAD12F1A, DRAD18F1A, DRAD24F1A, DRAF18F1A, DRAF24F1A, DRAL06F1A, DRAL09F1A, DRAL12F1A, DRAL18F1A, DRAM18F1A, DRAM24F1A, DRAM30S1A, DRAM36S1A, DRAM48S1A, DRAM60S1A, DRAS12F1A, DRAS12F1BSheet
Indoor dimensions (W × D × H)22.44 x 22.44 x 10.24 inSheet
Vertical louversAutoSheet
Horizontal louversManuel / ManualSheet
Airflow (reference head)379 CFMSheet
Indoor sound (reference head)36 – 43 dB(A)Sheet
Installation
Outdoor unit (W × D × H)37.50 x 16.31 x 52.50 inSheet
Outdoor sound62 dB(A)Sheet
Base pan heater150 WNEEP
Electrical
Voltage220 VSheet
MCA (minimum circuit ampacity)40 ASheet
MOP (maximum overcurrent protection)60 ASheet
RefrigerantR-410ASheet
Wi-FiOptionalSheet
Certifications and warranty
AHRI210568208AHRI
Warranty (compressor · parts · labour)10 yrs · 10 yrs · 6 yrsSheet
AirGreen extended warrantyPossibleSheet
15 · Official brochures

The manufacturer’s documentation, as PDF.

16 · Description

Everything we have written about this system.

Une véranda quatre saisons vit avec un air qui ne bouge jamais assez

Une résidence de Candiac dotée d'une véranda quatre saisons hérite d'une pièce qui n'a ni les apports de la maison, ni son brassage d'air. L'hiver, l'air y stagne le long des grandes surfaces vitrées ; l'été, il y chauffe sans se renouveler, et la première facture complète révèle le coût de tenir ce volume à température avec des plinthes. La Thermopompe 4-Zones DURASTAR Standard | 55 000 BTU - R410A traite la véranda comme une zone à part entière, avec sa propre tête, sa propre consigne et son propre débit d'air.

Le mouvement d'air, zone par zone

La tête de référence publiée par DuraStar déplace 379 pi³/min et se tient entre 36 et 43 dB(A) ; ces chiffres décrivent une seule unité et non les quatre têtes du système. Dans une véranda, ce débit sert autant en hiver qu'en été : il décolle l'air froid des surfaces vitrées. Le déflecteur vertical travaille en mode automatique, ce qui balaye le volume, et le déflecteur horizontal se règle à la main.

Les paliers inscrits par le NEEP

  • Cotes saisonnières : 20,2 SEER2, 10,5 EER2 et 9,6 HSPF2
  • À -8 °C : 36 400 BTU/h, COP de 2,56
  • À -15 °C : 33 200 BTU/h, COP de 1,80
  • Limite de chauffage inscrite à -25 °C

Ces données proviennent du certificat AHRI 210568208, publié par le NEEP. Le COP de 2,56 à -8 °C est le chiffre qui parle pour une véranda : c'est la plage où la pièce demande le plus longtemps. Ce système ne figure pas sur la liste des thermopompes admissibles au programme LogisVert d'Hydro-Québec en vigueur, ce qui explique la valeur de 0 $ inscrite à sa fiche technique. Nous l'annonçons avant le devis, nous vérifions la liste à la date d'installation, et si un modèle inscrit convient, nous le présentons en comparaison sans avancer de montant.

Fixer le calendrier des travaux autour de la saison de la véranda

Quand poser, et dans quel ordre

Une véranda quatre saisons est la pièce la plus sensible au calendrier : elle devient inutilisable si on la traite en dernier en plein hiver. Nous arrêtons donc l'ordre des zones dès la soumission : relevé des pièces, choix des emplacements, pose du condenseur, tirage des lignes, mise sous vide, essais, mise en route. La véranda passe en premier quand la saison froide approche.

Le condenseur, sa hauteur et son bruit

L'unité extérieure mesure 37,50 po x 16,31 po x 52,50 po et se tient à 62 dB(A). Cette hauteur impose une base au sol mise de niveau, au-dessus de la ligne de neige, dégagée devant la grille. Nous l'éloignons de la véranda, dont les surfaces vitrées renvoient le bruit, et nous mesurons la distance aux fenêtres de chambre, y compris celles des voisins. L'élément chauffant du bac de base et le revêtement anticorrosion sont de série.

Quatre têtes et le partage des 55 000 BTU/h

Les 55 000 BTU/h nominaux se répartissent entre les quatre têtes selon le format retenu pour chacune : la véranda, très vitrée, réclame davantage qu'une chambre de surface comparable. Les vingt-trois modèles compatibles vont des DRAL09F1A aux DRAF24F1A et DRAM18F1A, et le châssis accepte jusqu'à cinq zones. Chaque tête rejoint le condenseur par sa propre paire de lignes frigorifiques, dont un parcours qui traverse la structure de la véranda. Nos installations sont entièrement apparentes, sans travaux à l'intérieur des murs. Fermer la zone de la véranda hors saison n'arrête pas les trois autres.

Le circuit dédié de 60 A et l'entretien

Le raccordement demande 220 V, un MCA de 40 A et un disjoncteur de 60 A sur un circuit dédié, après calcul de charge et avec toute mise à niveau du panneau annoncée avant la signature. Les filtres se rincent aux deux semaines et un entretien CVAC annuel vérifie les serpentins et l'écoulement du condensat. Entreprise familiale de Montréal depuis plus de quinze ans, titulaire des licences RBQ en ventilation, en réfrigération et en électricité et couverte par une assurance responsabilité de 5 000 000 $, AirGreen offre l'évaluation gratuite et la soumission écrite à Montréal, à Laval, à Longueuil, sur la Rive-Nord et sur la Rive-Sud. Nos réalisations montrent des vérandas traitées en zone distincte, et notre service de réparation prend le relais si un code persiste.

Demandez votre estimation gratuite pour la Thermopompe 4-Zones DURASTAR Standard | 55 000 BTU - R410A. Nous mesurons la surface vitrée, fixons l'ordre des quatre zones selon la saison et confirmons la capacité du panneau avant la signature.

Garantie : 10 ans sur le compresseur, 10 ans sur les pièces et 6 ans sur la main-d’œuvre, directement du distributeur.

17 · Questions

What people ask us about multi-zone systems.

Can I heat one room and cool another at the same time?

No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.

What happens when every room calls for heat?

They share the outdoor unit’s capacity: 36,400 BTU/h at −8 °C, 33,200 at −15 °C.

How many heads can I connect?

Up to 5 on this outdoor unit. This product is configured for 4 heads.

Down to what temperature does it heat?

Down to −25 °C.

Is it noisy?

Indoors, the reference head goes down to 36 dB(A). Outdoors, 62 dB(A): we place the unit away from bedroom windows.

Why a multi-zone instead of several wall units?

One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.

What does the warranty cover?

Our sheet lists 10 years on the compressor and 10 years on parts. AirGreen extended warranty: possible.

AirGreen

A multi-zone system is planned room by room. At your home.

We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.

RBQ 5645-9605-01Ventilation 15.8, refrigeration 15.10, electrical 16
We handle the circuitOur licence covers the electrical work
Beware of scamsHydro-Québec does no phone or door-to-door solicitation for LogisVert
Sources checked on October 1, 2026.NEEP, Cold Climate Air Source Heat Pump List, product 402875 (AHRI 210568208): capacities and COP, modulation, SEER2, EER2, HSPF2.Costs: Hydro-Québec Rate D, 11.142 ¢/kWh (second tier, since 1 April 2026). Amounts shown are estimates; only the responsible bodies confirm the grant awarded.