3-Zone Heat Pump DURASTAR Standard | 55,000 BTU - R410A

In stock
SKU: DRA5U55M1B
55,000BTU/h · 3 heads
−25 °Cheats down to
Optional Wi-FiR-410AUp to 5 heads
Talk to a technician · 514 316-2973
Outdoor unit DRA5U55M1BPossible indoor models DRAC09F1A, DRAC12F1A, DRAC18F1A, DRAC24F1A, DRAC24F1B, DRAD09F1A, DRAD12F1A, DRAD18F1A, DRAD24F1A, DRAF18F1A, DRAF24F1A, DRAL06F1A, DRAL09F1A, DRAL12F1A, DRAL18F1A, DRAM18F1A, DRAM24F1A, DRAM30S1A, DRAM36S1A, DRAM48S1A, DRAM60S1A, DRAS12F1A, DRAS12F1BAHRI 210568208
In short

The Durastar Standard R410A 55 000 multi-zone heat pump heats and cools 3 rooms with a single outdoor unit. it delivers 36,400 BTU/h at −8 °C, heats down to −25 °C. Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.

01 · The verdict in 10 seconds

3 rooms, one outdoor unit.

Compared with the 13 multi-zone systems of 55,000 BTU we sell. Every number on this page carries its source.

NEEP 402875AHRI 210568208
!Good to know: heats down to −25 °CRank 10 of 13; class median: −30 °C.
36,400BTU/h certified at −8 °C
−25 °Cstill heating
3 → 5heads, on the same unit
2.56COP at −8 °C
02 · The machine

The parts that make a multi-zone system.

Tap a part to learn more.

DRA5U55M1B

Outdoor unit

One compressor for the whole house. It supplies up to 5 heads and modulates from 20,000 to 37,000 BTU/h depending on what the rooms call for (NEEP).

03 · How it works

Turn rooms on and off. Watch the power being shared.

One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.

04 · My plan

Tell us your rooms. We tell you if this size is enough.

Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide, the real calculation is done room by room at your home.

05 · The series

The whole series at a glance: find the box that fits you.

Each box is a product: the outdoor unit’s size, and the number of heads.

Outdoor2 zones3 zones4 zones5 zones
18,000BTU
2
28,000BTU
23
36,000BTU
234
48,000BTU
2345
55,000BTU
2Here45

Durastar Standard R410A 55 000 · 3 zones

36,400 BTU/h
at −8 °C

Up to 5 heads on this outdoor unit. Tap another box to see that size.

06 · Deep cold

At −15 °C, it still delivers 60 % of its rated capacity.

Tap a temperature: certified capacity, efficiency and the cost of one hour of heating.

It slows down, it speeds up: the certified modulation range

Light bar: from minimum to maximum capacity. Dark mark: the rated value.

+8.3 °C
20,000 → 60,000 BTU/h
-8 °C
18,000 → 37,000 BTU/h
-15 °C
13,000 → 33,200 BTU/h
Source: NEEP, minimum, rated and maximum ratings at 47, 17 and 5 °F.
07 · The bill

At every temperature, cheaper than baseboards.

Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.

08 · Efficiency

The official ratings, on the same scales as before.

SEER2, HSPF2 and EER2 come from the AHRI certification. The mark shows the median of the same-size multi-zone systems we sell.

SEER2 · seasonal cooling20.2
Scale 1 – 30Median: 20.2
Rank 6 (tied) of 13 in its class.
HSPF2 · seasonal heating9.6
Scale 1 – 15Median: 9.6
Rank 6 (tied) of 13 in its class.
EER2 · cooling in peak heat10.5
Scale 1 – 20Median: 10.5
Rank 6 (tied) of 13 in its class.
COP at −15 °C1.8
Scale 0 – 4Median: 1.8
Rank 6 (tied) of 13 in its class.
09 · Report card

Where it ranks among same-size multi-zone systems.

Compared with the 13 multi-zone systems of 55,000 BTU we sell. Weaknesses too, said plainly.

10 · Multi-zone or wall units

One multi-zone or several wall units? Both sides, honestly.

This multi-zone3 wall units
On the wall1 outdoor unit3 outdoor units
Electrical1 dedicated circuitOne circuit per unit
CapacityShared between roomsReserved for each room
If the outdoor unit stopsEvery zone stopsOnly one room
ModesSame mode everywhereEach room chooses
LogisVertPer the listDepends on each model

We compare both options on your floor plan during the estimate.

11 · Installation

What to know before installing a multi-zone system.

Dimensions, wiring and lines, drawn. Then our six steps.

The outdoor unit, dimensioned

52.50 in
DRA5U55M1BDepth 16.31 in
37.50 in
Dimensions: product sheet (W × D × H).

One circuit for the whole house

Electrical panel
Load calculation before the quote
60 A max. breaker
MCA 40 A · 220 V
Outdoor unit
Head 1
Head 2
Head 3
Our RBQ licence covers electrical work (subclass 16).
01Room-by-room visit and surveyWe measure each zone and note insulation and windows. The on-site estimate is free.
02Heads and line layoutOne pair of lines per head.
03Outdoor unit baseAbove the snow line, away from the neighbours’ bedroom windows.
04Exposed, finished linesLines under line covers, no work inside the walls.
05Dedicated circuit220 V, MCA 40 A, 60 A protection. The panel load calculation is done before the quote.
06Commissioning, zone by zoneEach head is tested and the controls set up.
12 · Sound

Published sound levels, on one scale.

We use the outdoor figure to choose where the unit goes.

36
43
62
36
61
20 dB(A)3040506070
36 Reference head, lowest speed43 Reference head, highest speed36 Class indoor median62 Outdoor unit61 Class outdoor median
Values in dB(A). Indoor values are those of the sheet’s reference head; each head has its own, confirmed for the chosen model. Municipal noise by-laws vary by borough.
13 · What sets it apart

What is particular about this machine.

Only facts published by ENERGY STAR, NEEP or the manufacturer.

20,000BTU/h at low speedMinimum certified capacity (NEEP): it slows down instead of stopping when a single room calls.
150 WBase pan heaterHeater in the outdoor unit’s base pan, against ice (NEEP).
14 · Specifications

Every number, and where it comes from.

Each line carries its source; a line with no published value is not shown.

Performance
Cooling capacity (size)55,000 BTUSheet
Certified cooling at 35 °C55,000 BTU/hNEEP
SEER2 (seasonal cooling efficiency)20.2AHRI
EER2 (instant cooling efficiency)10.5AHRI
HSPF2 (seasonal heating efficiency, region IV)9.6AHRI
HSPF2, region V (coldest)7NEEP
Heating
Capacity at +8.3 °C55,000 BTU/h · COP 3.14NEEP
Capacity at −8 °C36,400 BTU/h · COP 2.56NEEP
Capacity at −15 °C33,200 BTU/h · COP 1.8NEEP
Capacity at -15 °C (max.)33,200 BTU/h · COP 1.8Sheet
Modulation range20,000 – 37,000 BTU/hNEEP
Heats down to−25 °CSheet
Zones and heads
Zones on this product3 Zones (Triple Zone)Sheet
Maximum zones5 ZonesSheet
Possible indoor modelsDRAC09F1A, DRAC12F1A, DRAC18F1A, DRAC24F1A, DRAC24F1B, DRAD09F1A, DRAD12F1A, DRAD18F1A, DRAD24F1A, DRAF18F1A, DRAF24F1A, DRAL06F1A, DRAL09F1A, DRAL12F1A, DRAL18F1A, DRAM18F1A, DRAM24F1A, DRAM30S1A, DRAM36S1A, DRAM48S1A, DRAM60S1A, DRAS12F1A, DRAS12F1BSheet
Indoor dimensions (W × D × H)22.44 x 22.44 x 10.24 inSheet
Vertical louversAutoSheet
Horizontal louversManuel / ManualSheet
Airflow (reference head)379 CFMSheet
Indoor sound (reference head)36 – 43 dB(A)Sheet
Installation
Outdoor unit (W × D × H)37.50 x 16.31 x 52.50 inSheet
Outdoor sound62 dB(A)Sheet
Base pan heater150 WNEEP
Electrical
Voltage220 VSheet
MCA (minimum circuit ampacity)40 ASheet
MOP (maximum overcurrent protection)60 ASheet
RefrigerantR-410ASheet
Wi-FiOptionalSheet
Certifications and warranty
AHRI210568208AHRI
Warranty (compressor · parts · labour)10 yrs · 10 yrs · 6 yrsSheet
AirGreen extended warrantyPossibleSheet
15 · Official brochures

The manufacturer’s documentation, as PDF.

16 · Description

Everything we have written about this system.

Deux agrandissements en enfilade, et de l'air à pousser jusqu'au bout

Un bungalow de Laval agrandi à deux reprises se lit comme une suite de pièces mises bout à bout, chacune séparée de la précédente par un seuil, une marche ou une porte. Depuis que le télétravail est devenu permanent, la pièce du fond sert de bureau toute la journée, et c'est justement celle que l'air conditionné n'atteignait jamais. La Thermopompe 3-Zones DURASTAR Standard | 55 000 BTU - R410A traite l'enfilade en trois segments, chacun avec sa propre tête et son propre débit, au lieu d'essayer de pousser l'air d'une extrémité à l'autre.

Ses cotes sont de 20,2 SEER2, 10,5 EER2 et 9,6 HSPF2, pour une capacité nominale de 55 000 BTU/h et une limite de chauffage de -25 °C.

Les cotes portées au certificat 210568208

  • À -8 °C : 36 400 BTU/h, avec un COP de 2,56
  • À -15 °C : 33 200 BTU/h, avec un COP de 1,80
  • Limite de chauffage inscrite : -25 °C
  • Unité extérieure DRA5U55M1B : 37,50 x 16,31 x 52,50 po et 62 dB(A)

Ces données proviennent du certificat AHRI 210568208, publié par le NEEP. Le débit de 379 PCM, le niveau de 36 à 43 dB(A) et le boîtier de 22,44 x 22,44 x 10,24 po sont ceux de la seule tête que la fiche retient comme référence.

Le débit d'air, tête par tête, dans une enfilade

Dans une maison allongée, la distance tue le débit bien avant que la capacité ne manque : un appareil unique placé au centre envoie son air contre un mur de refend et s'arrête là. Trois têtes découpent le trajet, chacune brassant 379 PCM dans son segment, volet vertical automatique et volet horizontal réglable à la main. Le bureau du fond cesse de dépendre du salon.

Pourquoi ce format affiche 0 $ au programme LogisVert

Ce système ne figure pas sur la liste des thermopompes admissibles au programme LogisVert d'Hydro-Québec en vigueur, ce qui explique la valeur de 0 $ affichée dans la fiche technique. Nous le disons avant d'aller plus loin. Si l'aide change la décision, nous vérifions quels formats voisins figurent sur la liste en vigueur à la date d'installation ; des options de financement étalent le montant.

Laval : trois parcours de lignes et trois écoulements à prévoir

Répartir 55 000 BTU/h sur trois zones inégales

Les 55 000 BTU/h forment une réserve commune aux trois têtes. Dans un bungalow agrandi deux fois, les segments n'ont ni la même isolation ni la même fenestration : la partie d'origine est la mieux protégée, la dernière rallonge la plus exposée. Nous partons de la règle de 18 000 BTU/h par 1 000 pieds carrés, ajustée segment par segment. Arrêter la zone du bureau le soir laisse les deux autres en service. Les ensembles publiés comprennent DRAM30S1A, DRAC24F1A, DRAD24F1A et DRAL18F1A.

Trois tracés de lignes et trois évacuations de condensat

Chaque tête est reliée à l'unité extérieure par sa propre paire de lignes, et chacune doit évacuer son condensat. Dans un plain-pied agrandi, la pente naturelle manque souvent sur la dernière rallonge, et une pompe de relevage prend le relais de la gravité. Les trois tracés se dessinent avant la pose, car ils commandent l'emplacement du châssis. La pose est entièrement apparente, sans travaux à l'intérieur des murs.

Le circuit de 60 A du bungalow

La fiche demande 220 V, un MCA de 40 A et un disjoncteur de 60 A sur un circuit dédié. Toutes les entrées n'absorbent pas ce calibre : un panneau de 200 A l'accepte, alors qu'une entrée de 100 A déjà chargée par les plinthes et le chauffe-eau impose un calcul de charge et une mise à niveau annoncée avant la signature. Un code d'erreur persistant ou de l'eau à l'intérieur demandent l'arrêt et un appel à notre service de réparation.

AirGreen, pour une maison agrandie par étapes

Entreprise familiale depuis plus de quinze ans, nous desservons Montréal, Laval, Longueuil, la Rive-Nord et la Rive-Sud, avec les licences RBQ en ventilation, en réfrigération et en électricité. L'évaluation est gratuite et la soumission est remise par écrit. Les filtres se rincent aux deux semaines et l'entretien CVAC annuel couvre les serpentins, le condensat et les raccords électriques.

Planifiez votre estimation gratuite pour la Thermopompe 3-Zones DURASTAR Standard | 55 000 BTU - R410A. Nous relevons chaque segment de l'enfilade, vérifions la capacité du panneau pour un disjoncteur de 60 A et déterminons où le condensat s'écoule par gravité.

Garantie : 10 ans sur le compresseur, 10 ans sur les pièces et 6 ans sur la main-d’œuvre, directement du distributeur.

17 · Questions

What people ask us about multi-zone systems.

Can I heat one room and cool another at the same time?

No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.

What happens when every room calls for heat?

They share the outdoor unit’s capacity: 36,400 BTU/h at −8 °C, 33,200 at −15 °C.

How many heads can I connect?

Up to 5 on this outdoor unit. This product is configured for 3 heads.

Down to what temperature does it heat?

Down to −25 °C.

Is it noisy?

Indoors, the reference head goes down to 36 dB(A). Outdoors, 62 dB(A): we place the unit away from bedroom windows.

Why a multi-zone instead of several wall units?

One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.

What does the warranty cover?

Our sheet lists 10 years on the compressor and 10 years on parts. AirGreen extended warranty: possible.

AirGreen

A multi-zone system is planned room by room. At your home.

We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.

RBQ 5645-9605-01Ventilation 15.8, refrigeration 15.10, electrical 16
We handle the circuitOur licence covers the electrical work
Beware of scamsHydro-Québec does no phone or door-to-door solicitation for LogisVert
Sources checked on October 1, 2026.NEEP, Cold Climate Air Source Heat Pump List, product 402875 (AHRI 210568208): capacities and COP, modulation, SEER2, EER2, HSPF2.Costs: Hydro-Québec Rate D, 11.142 ¢/kWh (second tier, since 1 April 2026). Amounts shown are estimates; only the responsible bodies confirm the grant awarded.