KINGHOME Ultranixx R32 Central Heat Pump | 2 Tons - 24,000 BTU | A-Coil
Keep the gas furnace and leave it only the coldest nights
Many small houses in Montréal and Longueuil are heated by a natural gas furnace that's still in good shape, paired with an old central air conditioner. Replacing the furnace makes no sense if it still has years left in it. What needs replacing is the air conditioner, and the right replacement is a central heat pump that cools in summer and handles most of the heating in winter. That's the job of this 2-ton Ultranixx system: the KU36UXO outdoor unit paired with the KCAC24FI A-coil, certified together under AHRI 218046860.
The coil sits directly on the furnace's air outlet, in place of the air conditioner's old coil. The furnace keeps its burner and its fan; that fan is what pushes the air through the heat pump's coil. The result is a dual-energy system: electricity for most of the year, gas as backup when the cold gets extreme.
How the work is shared between the heat pump and the furnace
The two units never heat at the same time: the manufacturer prohibits it for safety reasons. The thermostat, or the outdoor unit's control, chooses one or the other based on the outdoor temperature and the house's demand. During the outdoor unit's defrost cycles, a signal is sent to the furnace so it keeps warm air in the ducts, which prevents the bursts of cool air that poorly integrated central heat pumps are often blamed for.
The changeover point is set during commissioning. We set it based on the system's certified capacity and the on-site assessment of the house's heating needs, not on a default value.
The capacities of this pairing
The seasonal ratings are 16 SEER2, 8.5 HSPF2 and an EER2 of 11. The heating capacities listed on NEEP (AHRI No. 218046860) read as follows:
- At -8.3 °C: 15,000 BTU/h, with a COP of 2.1
- At -15 °C: 24,000 BTU/h, with a COP of 1.8
- At -30 °C: 19,300 BTU/h, with a COP of 1.4
These figures are published as is, and they call for a careful reading. The value at -8.3 °C is the lowest of the three, while the values at -15 °C and -30 °C are clearly higher. They reflect the speeds at which the inverter compressor was measured at each test point. For us, the practical consequence is simple: it's precisely because the furnace stays in place that this pairing makes sense. The on-site assessment of heating needs determines the temperature at which the furnace takes over, and the heat pump covers the rest of the season. The outdoor unit's heating range goes down to -30 °C, and the system carries the ENERGY STAR cold climate designation (ID 4577690).
A compact coil that fits most furnaces
The KCAC24FI coil measures 17.50 x 21.25 x 23.00 inches. Its width matches that of many low-capacity furnaces, which limits plenum modifications. It can also be installed horizontally, and its control box can be moved to suit the available space. It's equipped with an electronic expansion valve, a primary drain pan, a secondary pan and a refrigerant leak sensor. The system runs on R-32. Wi-Fi is available as an option, and a compatible smart thermostat can be added.
What we check before the installation
A coil on a furnace only works well if the furnace itself is up to it. Here's what we confirm during a visit in Montréal, Laval or Longueuil, on the North Shore or on the South Shore.
The furnace's condition and compatibility
We check the furnace's age, the condition of its heat exchanger, its fan and its control board. The fan has to be able to deliver the minimum airflow required with an R-32 coil; if it can't, we tell you before selling anything. A furnace at the end of its life is better replaced with the air handler version of the same series.
The power supply
The outdoor unit requires a single-phase 220 V supply, a minimum circuit ampacity (MCA) of 28 A and a maximum overcurrent protection (MOP) of 30 A. The old air conditioner's circuit can sometimes be reused, but only if its wire gauge and breaker match these values.
The outdoor unit location
The KU36UXO unit measures 39.00 x 14.56 x 37.81 inches, with a published sound level of 60 dB(A). Unlike an air conditioner, it runs all winter: it has to sit on a bracket or a pad that keeps it above the snow and lets the defrost water drain. The old air conditioner's spot, often right at ground level, is rarely the right one.
The piping and the drain
The connections are 3/8 and 3/4 inch. An existing air conditioner line set is only reused if its diameter, its condition and a cleaning allow it. The coil is connected to the drain through a trap, with a continuous slope; the secondary pan is connected when the installation requires it. The vacuum is completed before the valves are opened.
The safety wiring
The coil's leak sensor has to be wired to the furnace. If a leak is detected, the outdoor unit shuts down, the furnace fan switches to high speed and the burner is locked out. We test this sequence at commissioning.
LogisVert assistance
This system has an indicative LogisVert amount of $1,800, calculated using the LogisVert rule ($120 per 1,000 BTU/h of certified heating capacity at -8.3 °C); eligibility is confirmed on the installation date. Only Hydro-Québec confirms the assistance granted. The file references are AHRI 218046860 and ENERGY STAR ID 4577690.
Why go with AirGreen
- Salaried refrigeration technicians who know dual-energy integration with gas furnaces.
- Civil liability insurance of $5,000,000.
- Warranty registration handled by us.
- After-sales service for maintenance and changeover point adjustments.
Ask for your free estimate for the 2-ton Ultranixx with A-coil: we inspect your furnace, do the on-site assessment of your house's heating needs and give you a clear quote.
Documentation
- KCAC24FI + KU36UXO spec sheet (English)
- Ultranixx outdoor unit manual (French)
- Ultranixx coil manual (French)
Warranty: 12 years on the compressor, 12 years on parts and 6 years on labour, directly from the distributor, on registered models.