KINGHOME Ultranixx R32 Central Heat Pump | 4 Tons - 48,000 BTU | Air Handler

In stock
SKU: KU60UXO-KD48UXI
48,000BTU/h · nominal capacity
−30 °Cheats down to
$4,740LogisVert grant, indicative
ENERGY STAR® · cold climateOptional Wi-FiR-3212-yr compressor, 12-yr parts

For a large house where cooling matters as much as heating

A good-sized house, often renovated into an open-concept layout with large south- or west-facing windows, has two needs that pull in opposite directions: lots of heat in January and lots of cooling in July. This 4-ton Ultranixx pairing, made up of the KU60UXO outdoor unit and the KD48UXI air handler, certified together under AHRI 217194946, is the most efficient in the series for cooling. It's the central heat pump we recommend when the house has ductwork, the existing furnace has to come out and summer comfort matters as much as winter comfort.

19 SEER2: the best cooling rating in the series

The system is certified at 19 SEER2, with an EER2 of 11.7 and 10 HSPF2. SEER2 measures seasonal energy use in cooling; in a house with a lot of glass, it's the rating that determines the summer bill. EER2 measures efficiency in high heat, when the whole street is running its air conditioners. The inverter compressor modulates its speed and avoids the repeated starts that wear out a basic unit and leave the air humid.

In cooling mode, the KD48UXI removes up to 8.49 pints of moisture per hour. In an open-concept space where the kitchen, dining room and living room share the same volume of air, this dehumidification capacity prevents the cold, clammy feeling that oversized units create.

Heating in extreme cold

The system's heating capacities listed on NEEP (AHRI No. 217194946) are as follows:

  • At -8.3 °C: 39,500 BTU/h, with a COP of 2.86
  • At -15 °C: 48,000 BTU/h, with a COP of 2.0
  • At -30 °C: 26,200 BTU/h, with a COP of 1.25

The COP of 2.86 at -8.3 °C is the highest of the Ultranixx air handler pairings: at that temperature, very common in a Montréal winter, the unit produces nearly three times more heat than the electricity it uses. At -15 °C, it delivers 100% of its 48,000 BTU/h nominal capacity. At -30 °C, it still provides 55%, and the optional backup heater makes up the rest when the on-site assessment of heating needs calls for it. The heating range goes down to -30 °C, and the system carries the ENERGY STAR cold climate designation (ID 4011419). As with the whole series, the value at -15 °C is higher than the one at -8.3 °C: these are the figures as certified.

Airflow to match the house

The air handler moves up to 1,200 CFM. That kind of airflow calls for a serious duct system: a plenum with a good cross-section, return air in the main rooms and branches that aren't crushed between the joists. In a house that's been extended over the years, it sometimes turns out the original ductwork was never adapted to the addition. We measure it before installing a unit of this capacity. The cabinet, at 24.81 x 21.25 x 52.00 inches, can be installed in a vertical or horizontal position, and it has a built-in refrigerant leak sensor.

A vertical outdoor unit

The KU60UXO has a tall, narrow format: 35.44 x 13.38 x 49.63 inches. Its shallow depth makes it easy to install along a side wall, where a wide unit would block the passage between two houses. The published sound level is 62 dB(A) outdoors and 53 dB(A) indoors. The units communicate over a two- or four-wire digital bus, and they're compatible with conventional low-voltage thermostats; Wi-Fi is available as an option. The refrigerant is R-32.

What we check before installation

On a house this size, the on-site assessment makes all the difference. Here is what we validate during a visit in Laval, Longueuil, on the North Shore, on the South Shore or in Montréal.

Electrical capacity

The outdoor unit requires a 220 V single-phase supply, an MCA of 39 A and a maximum overcurrent protection (MOP) of 45 A. The air handler has its own circuit, and a high-capacity backup heater can add a considerable load. In a large house that already has an EV charger, a spa or a full electric kitchen, we do a load calculation on the electrical panel before confirming. If the electrical service needs to be upgraded, the quote says so clearly.

The on-site assessment of heating and cooling needs

We assess heating and cooling needs on site, room by room, paying particular attention to the windows. A house with a lot of west-facing windows can need four tons for cooling while heating alone would need less. We choose the capacity based on the more demanding need, without oversizing.

Outdoor unit location

We set the unit on a stand or pad that keeps it above the snow and lets defrost water drain away. The vertical format of the KU60UXO often allows it to go in a narrow side yard, but the manufacturer's clearances and the municipal bylaws on distance from property lines have to be respected.

Piping and drain

The connections are 3/8 and 3/4 inch. The air handler's condensate drain gets a trap and a continuous slope; in the horizontal position, a secondary drain pan is added. The vacuum is completed before commissioning.

LogisVert assistance

This system has an indicative LogisVert amount of $4,740, calculated according to the LogisVert rule ($120 per 1,000 BTU/h of certified heating capacity at -8.3 °C); eligibility is confirmed on the installation date. Only Hydro-Québec confirms the assistance granted. The file references are AHRI 217194946 and ENERGY STAR ID 4011419.

Why go with AirGreen

  • Salaried refrigeration technicians, with no improvised subcontracting.
  • Civil liability insurance of $5,000,000.
  • Warranty registration done by us at commissioning.
  • After-sales service for seasonal maintenance and follow-ups.

Request your free estimate for the 4-ton Ultranixx with air handler: we assess your house, your panel and your ducts, then give you an accurate quote.

Documentation

Warranty: 12 years on the compressor, 12 years on parts and 6 years on labour, directly from the distributor, on registered models.