KINGHOME Ultranixx R32 Central Heat Pump | 2 Tons - 24,000 BTU | Air Handler

In stock
SKU: KU36UXO-KD24UXI
24,000BTU/h · nominal capacity
−30 °Cheats down to
$2,472LogisVert grant, indicative
ENERGY STAR® · cold climateOptional Wi-FiR-3212-yr compressor, 12-yr parts

Replace a small house's electric furnace and air conditioner with a single system

In a bungalow, a semi-detached house or a compact cottage, the original central system often comes down to an electric furnace in the basement and an air conditioner against the back wall. When one of them gives out, the reflex is to replace only the broken piece. We suggest replacing both with a single central heat pump that heats and cools through the existing ducts. That's what this 2-ton Ultranixx system is for: the KU36UXO outdoor unit matched with the KD24UXI air handler, certified together under AHRI 217194944.

The air handler takes the furnace's place. It contains the coil, the blower and the control electronics, and it connects to the existing supply plenum and return air. For a house whose heating needs, assessed on site, are around 24,000 BTU/h, it's the simplest format in the series: one cabinet inside, one unit outside and no combustion in the house.

Heating capacity that holds up in the dead of winter

The system's seasonal ratings are 18 SEER2, 10 HSPF2 and an EER2 of 12. In Québec, though, the most useful figure is still cold-weather capacity, and that's where this matchup stands out; here are the values listed on NEEP (AHRI No. 217194944):

  • At -8.3 °C: 20,600 BTU/h, with a COP of 2.7
  • At -15 °C: 24,000 BTU/h, with a COP of 2.0
  • At -30 °C: 18,000 BTU/h, with a COP of 1.36

The certified capacity at -15 °C equals the nominal capacity of 24,000 BTU/h: the unit delivers 100% of its capacity at a temperature where most of the electric furnaces it replaces are already running flat out. At -30 °C, it still provides 75% of that value with a COP above 1, which means every kilowatt-hour it uses produces more heat than an electric resistance heater would, even on the coldest days of January. The heating operating range goes down to -30 °C, and the system carries the ENERGY STAR cold climate designation (ID 4011417).

The value at -15 °C is higher than the one at -8.3 °C. It's not a typo: both figures are published as certified. The inverter compressor ramps up as demand increases, and it's this extended speed range that the -15 °C test point measures.

Air handler or coil: why this format here

The Ultranixx series comes in two versions. The A-Coil sits on top of an existing gas furnace, which stays in place as backup in a dual-energy setup. The air handler, on the other hand, replaces the furnace entirely. In a house heated with electricity, it's the logical choice: there's no combustion appliance to keep, and the KD24UXI cabinet can be installed vertically or horizontally, which helps in a low basement or a crawl space. An optional electric backup heater can be built into the air handler for the coldest days or as emergency heat.

The indoor cabinet measures 18.13 x 21.25 x 43.50 inches. It's the most compact of the series' four air handlers, a real advantage in the narrow mechanical rooms found in many houses in Laval and on the South Shore, where the original furnace is squeezed between the water heater and the stairs.

Airflow, dehumidification and sound level

The indoor blower moves 760 CFM. That airflow suits original duct systems designed for a small furnace, provided the return air is sufficient, which we measure on site rather than assume. In cooling mode, the unit removes up to 4.25 pints of moisture per hour, which makes a difference in a finished basement in July. The published sound level is 50 dB(A) for the indoor unit and 60 dB(A) for the outdoor unit. Wi-Fi control is available as an option.

R-32 refrigerant and simplified controls

The system runs on R-32, a refrigerant with a lower global warming potential than R-410A that also carries heat better. The air handler has a built-in refrigerant leak sensor connected to the control board. The outdoor unit communicates with the indoor unit over a two- or four-wire digital bus, while remaining compatible with conventional low-voltage thermostats. The inverter-driven twin-cylinder rotary compressor adjusts its speed to the house's actual load, which avoids short cycling and temperature differences between floors.

What we check before installation

A spec sheet won't tell you whether a unit suits a specific house. During a visit in Montréal, Laval, Longueuil, the North Shore or the South Shore, we check the following points before confirming a quote.

The assessment of heating needs

We do an on-site assessment of heating needs, taking into account insulation, windows and air leakage. Two tons suit a well-insulated house of modest size. If the assessment shows more, we recommend the three-ton matchup rather than letting the backup heater make up the difference all winter.

Power supply

The outdoor unit requires a 220 V single-phase supply, a minimum circuit ampacity (MCA) of 21 A and a maximum overcurrent protection (MOP) of 25 A. The air handler is powered by its own circuit, and the backup heater, if added, represents a significant load on the panel. In a house that was already heated with an electric furnace, the electrical service is usually sufficient, but we do a load assessment before committing.

Outdoor unit location

The KU36UXO unit measures 39.00 x 14.56 x 37.81 inches. We set it on a wall bracket or a pad that keeps it above the snow buildup and lets defrost water drain, away from roof edges that drop ice and, as much as possible, away from the neighbour's bedroom windows. A unit buried after a storm defrosts more often and uses more energy.

Piping and drain

The refrigerant connections are 3/8 and 3/4 inch. We normally replace an old air conditioner's line set rather than reuse it, unless its diameter, condition and cleanliness allow it. The air handler's condensate drain gets a trap and a continuous slope; in the horizontal position, we add a secondary drain pan. A full vacuum is pulled before the valves are opened.

Ducts and filter

We inspect the plenum joints, registers that have been closed for years and the return air. An accessible filter of the right size is planned from the day of installation: a clogged filter cuts airflow, and with it heating capacity.

The LogisVert grant

This system has an indicative LogisVert amount of $2,472, calculated according to the LogisVert rule ($120 per 1,000 BTU/h of certified heating at -8.3 °C); eligibility is confirmed on the installation date. Only Hydro-Québec confirms the assistance granted. We include AHRI 217194944 and ENERGY STAR ID 4011417 in the file, as the program requires.

Why choose AirGreen

  • Salaried refrigeration technicians trained on central ducted systems.
  • Civil liability insurance of $5,000,000.
  • Warranty registration done by us, on start-up day.
  • After-sales service you can reach for maintenance and follow-ups.

Request your free estimate for the 2-ton Ultranixx with air handler: we assess your house's heating needs on site, check the panel and the ducts, and give you a clear quote.

Documentation

Warranty: 12 years on the compressor, 12 years on parts and 6 years on labour, directly from the distributor, on registered models.