KINGHOME Ultranixx R32 Central Heat Pump | 5 Tons - 60,000 BTU | A-Coil
A high-capacity heat pump on the furnace of a large house
Large houses heated with natural gas often have a high-capacity furnace, installed a few years ago, and a central air conditioner that struggles to cool the upper floor in July. When the air conditioner reaches the end of its life, replacing it with a 5-ton central heat pump turns the installation into a dual-energy system: the heat pump heats and cools, and the furnace is only used as backup. This Ultranixx system, the KU60UXO outdoor unit paired with the KCAC60HI A-coil, certified together under AHRI 217603526, is the largest capacity offered in the coil version.
The capacities and what they make possible
The system is certified at 16 SEER2, 9 HSPF2 and an EER2 of 9.8. The heating capacities listed on NEEP (AHRI No. 217603526) are as follows:
- At -8.3 °C: 41,000 BTU/h, with a COP of 2.34
- At -15 °C: 54,000 BTU/h, with a COP of 1.8
- At -30 °C: 24,900 BTU/h, with a COP of 1.14
At -15 °C, the heat pump delivers 90% of its 60,000 BTU/h nominal capacity. That's enough to heat a large, well-insulated house on its own for most of the winter. At -30 °C, the capacity drops by more than half, and that's exactly where the furnace takes over again. The changeover point is set at commissioning, based on the on-site assessment of heating needs. The value at -15 °C is higher than the one at -8.3 °C, as shown on the certificate. The heating range goes down to -30 °C, and the system carries the ENERGY STAR cold climate designation (ID 4657195).
The 9.8 EER2 is lower than that of the smaller pairings. It measures efficiency in very hot weather, a condition that represents only a small share of cooling hours in Québec. The SEER2 of 16, which covers the whole season, is still the rating to look at for your summer bill.
Why keep the furnace in a large house
A large all-electric house would need a high-capacity backup heating element for the coldest nights, along with the electrical service that goes with it. By keeping the gas furnace for those few periods, you often avoid a panel upgrade, while shifting most of the season's heating hours to electricity.
The KCAC60HI coil and the space in the basement
The coil measures 24.50 x 21.25 x 28.50 inches. Its width matches high-capacity furnaces, and its height adds to the furnace's height under the supply plenum. In a basement with a low ceiling, or when the plenum runs straight to the joists, this height has to be checked before the installation is confirmed: the transition between the furnace and the duct network sometimes has to be redone. The coil can also be installed horizontally, and its control box can be moved to suit the available space.
It includes an electronic expansion valve, a primary drain pan, a secondary pan and a refrigerant leak sensor. The system runs on R-32, whose global warming potential is much lower than that of R-410A.
Airflow that depends on the furnace
With a five-ton coil, the furnace fan has to move a large volume of air. A high-capacity furnace can generally do it, as long as its speed is set for the coil and not left at the factory setting meant for gas heating. The duct network, for its part, has to handle this airflow without the static pressure climbing to the point where the fan strains. We measure it on site.
Full dual-energy integration
The wiring connects the outdoor unit, the coil, the thermostat and the furnace. The heat pump and the furnace never heat at the same time. During defrost, a signal is sent to the furnace to avoid cold air in the ducts. If there's a refrigerant leak, the outdoor unit shuts down, the gas valve is closed and the fan switches to high speed. The twin-cylinder inverter compressor modulates its speed based on demand. Wi-Fi is available as an option.
What we check before the installation
During a visit in Montréal, Laval or Longueuil, on the North Shore or on the South Shore, we confirm these points before giving you a quote.
The furnace and the clearance
Age, condition of the heat exchanger, fan capacity, width of the air outlet and clear height under the ceiling: these factors decide whether the coil goes on directly or an adaptation is needed. A furnace at the end of its life is better replaced with the air handler version of the same series.
The power supply
The outdoor unit requires a single-phase 220 V supply, an MCA of 39 A and a maximum overcurrent protection (MOP) of 45 A. The circuit of an old five-ton air conditioner can sometimes be reused, but we check the wire gauge, the breaker and the remaining capacity of the panel.
The outdoor unit location
The KU60UXO unit has a vertical format of 35.44 x 13.38 x 49.63 inches and a published sound level of 62 dB(A). It has to stay above the snow, on a bracket or a pad that lets the defrost water drain, and a good distance from bedroom windows, yours as well as your neighbour's.
The piping and the drain
The connections are 3/8 and 3/4 inch. The old air conditioner's line set is only reused if its diameter and condition allow it. The drain gets a trap and a continuous slope, and the secondary pan is connected when required.
LogisVert assistance
This system has an indicative LogisVert amount of $4,920, calculated using the LogisVert rule ($120 per 1,000 BTU/h of certified heating capacity at -8.3 °C); eligibility is confirmed on the installation date. Only Hydro-Québec confirms the assistance granted. The file references are AHRI 217603526 and ENERGY STAR ID 4657195.
Why go with AirGreen
- Salaried refrigeration technicians who handle the furnace integration from start to finish.
- Civil liability insurance of $5,000,000.
- Warranty registration handled by us.
- After-sales service for maintenance and changeover point adjustments.
Ask for your free estimate for the 5-ton Ultranixx with A-coil: we check your furnace, the available space and your panel, then give you a detailed quote.
Documentation
- KCAC60HI + KU60UXO spec sheet (English)
- Ultranixx outdoor unit manual (French)
- Ultranixx coil manual (French)
Warranty: 12 years on the compressor, 12 years on parts and 6 years on labour, directly from the distributor, on registered models.