KINGHOME Ultranixx R32 Central Heat Pump | 3 Tons - 36,000 BTU | Air Handler

In stock
SKU: KU36UXO-KD36UXI
36,000BTU/h · nominal capacity
−30 °Cheats down to
$3,384LogisVert grant, indicative
ENERGY STAR® · cold climateOptional Wi-FiR-3212-yr compressor, 12-yr parts

The size that fits most two-storey houses with ductwork

The two-storey cottage with a basement is the most common house in the Montréal suburbs. Its original central system is almost always the same: an electric furnace, often installed in place of an old oil furnace, a duct network serving both floors and an air conditioner added later. When that equipment reaches the end of its life, a 3-ton central heat pump with an air handler is, in most cases, the most direct replacement. This Ultranixx system pairs the KU36UXO outdoor unit with the KD36UXI air handler, certified together under AHRI 217194945.

It shares the same outdoor unit as the two-ton pairing. What changes is the indoor unit: a larger coil and a stronger fan let the same compressor deliver more heating and cooling. It's a good example of what AHRI certification actually measures, meaning a specific matched system and not an outdoor unit on its own.

What the system delivers when it's cold

The seasonal ratings are 18 SEER2, 10 HSPF2 and an EER2 of 11.2. The heating capacities listed on NEEP (AHRI No. 217194945) are as follows:

  • At -8.3 °C: 28,200 BTU/h, with a COP of 2.5
  • At -15 °C: 34,000 BTU/h, with a COP of 2.0
  • At -30 °C: 20,400 BTU/h, with a COP of 1.31

At -15 °C, the system still delivers 94% of its 36,000 BTU/h nominal capacity. At -30 °C, it delivers 57%, still with a COP above 1: even in deep cold, it heats more efficiently than a baseboard or an electric furnace. The certified value at -15 °C is higher than the one at -8.3 °C, which reflects the inverter compressor ramping up as demand increases. The figures are published as certified. The heating range goes down to -30 °C, and the system carries the ENERGY STAR cold climate designation (ID 4011418).

The temperature difference between floors

The most frequent complaint in a two-storey cottage is an upstairs that's too hot in summer while the basement stays cold. A basic furnace runs on an all-or-nothing basis: it blows hard, stops, then starts again. The Ultranixx's twin-cylinder rotary compressor modulates its speed, and the KD36UXI's fan runs longer at reduced airflow. Air circulates between floors more often, which narrows the temperature difference. Maximum airflow is 1,000 CFM, a value most duct networks in a house this size can handle, provided the upstairs return air is adequate.

In cooling mode, the unit removes up to 6.02 pints of moisture per hour. In an upstairs bedroom in July, it's often the humidity, more than the temperature, that keeps you from sleeping.

An air handler that replaces the furnace

The air handler connects to the existing plenum and return air, in a vertical or horizontal position. Its cabinet measures 21.25 x 21.25 x 48.19 inches, which matches the space a replacement electric furnace usually takes up. An optional electric backup heater can be built in for emergency heat and the coldest days. If the house still has a gas furnace in good condition, the A-Coil version in the same series lets you keep it instead, in a dual-energy setup.

Refrigerant, controls and everyday comfort

The system runs on R-32, which has a lower global warming potential than R-410A. The air handler has a built-in refrigerant leak sensor. The units communicate over a two- or four-wire digital bus, and the installation remains compatible with a conventional low-voltage thermostat. Wi-Fi control is available as an option. The published sound level is 51 dB(A) for the indoor unit and 61 dB(A) for the outdoor unit.

What we check before the installation

During an assessment in Laval, in Longueuil, on the North Shore, on the South Shore or on the island of Montréal, we confirm these points before giving you a quote.

The on-site assessment of heating needs and choosing the capacity

We do an on-site assessment of the house's heating needs, room by room. Three tons suits a large share of cottages, but not all of them. A renovated house with new windows and an insulated attic can go down to two tons; a house with an addition or a poorly insulated basement may need four tons. Oversizing leads to short cycles and poor dehumidification. Undersizing keeps the backup heater working all winter.

Electrical supply

The outdoor unit requires a single-phase 220 V supply, an MCA of 27 A and a maximum overcurrent protection (MOP) of 30 A. The air handler has its own circuit, and the backup heater, if added, increases the load on the panel. We do an electrical review of the house, especially when an EV charger or an induction range is being added to the same panel.

Outdoor unit location

The KU36UXO unit measures 39.00 x 14.56 x 37.81 inches. It has to stay above the accumulated snow and let defrost water drain away. We favour a wall bracket or a suitable base, out of the path of ice falling from the roof and away from bedroom windows.

Piping and drain

The connections are 3/8 and 3/4 inch. An existing air conditioner line set is only reused if its diameter, condition and cleaning allow it. The condensate drain gets a trap and a continuous slope to the drain; in a horizontal installation, we add a secondary pan. The vacuum is completed before the valves are opened.

The ductwork

We inspect the plenum, the joints and the registers, and we measure static pressure. A single return air in the basement is often the reason an upper floor is poorly served; we point it out in the quote when a correction is warranted.

LogisVert assistance

This system has an indicative LogisVert amount of $3,384, calculated using the LogisVert rule ($120 per 1,000 BTU/h of certified heating capacity at -8.3 °C); eligibility is confirmed on the installation date. Only Hydro-Québec confirms the assistance granted. The references to keep are AHRI 217194945 and ENERGY STAR ID 4011418.

Why go with AirGreen

  • Salaried refrigeration technicians who install central systems every week.
  • Civil liability insurance of $5,000,000.
  • Warranty registration taken care of at commissioning.
  • After-sales service that handles maintenance and follow-ups.

Ask for your free estimate for the 3-ton Ultranixx with air handler: we do an on-site assessment of your home's heating needs, check your ductwork and your panel, and give you a detailed quote.

Documentation

Warranty: 12 years on the compressor, 12 years on parts and 6 years on labour, directly from the distributor, on registered models.