KINGHOME Ultranixx R32 Central Heat Pump | 4 Tons - 48,000 BTU | A-Coil

In stock
SKU: KU60UXO-KCAC48HI
48,000BTU/h · nominal capacity
−30 °Cheats down to
$4,224LogisVert grant, indicative
ENERGY STAR® · cold climateOptional Wi-FiR-3212-yr compressor, 12-yr parts

Sharply cut a large house's natural gas or propane use without removing the furnace

A large house heated with natural gas or propane, like many on the North Shore and in the less densely built areas of the South Shore, burns a lot of fuel from October to April. When the furnace is recent and efficient, replacing it makes no economic sense. Adding a central heat pump to that furnace, on the other hand, shifts most of the heating hours over to electricity. This 4-ton Ultranixx system, made up of the KU60UXO outdoor unit and the KCAC48HI A-Coil, certified under AHRI 217603527, is built for exactly that scenario.

The furnace stays in place and keeps its role as backup. The heat pump coil sits on the furnace's air outlet, and it's the furnace blower that distributes the air through the existing ductwork. This is what's called a dual-energy system.

What the system covers in winter

The system is certified at 16 SEER2, 9 HSPF2 and an EER2 of 11. The heating capacities listed on NEEP (AHRI No. 217603527) are as follows:

  • At -8.3 °C: 35,200 BTU/h, with a COP of 2.4
  • At -15 °C: 48,000 BTU/h, with a COP of 1.85
  • At -30 °C: 24,000 BTU/h, with a COP of 1.21

At -15 °C, the matched system delivers 100% of its 48,000 BTU/h nominal capacity; at -30 °C, it still provides 50%, with a COP above 1. For a large house, that means the heat pump can carry the heating load on its own for the vast majority of the winter, and the furnace only kicks in at the switchover point we set based on the on-site assessment of heating needs. As with the whole series, the value at -15 °C is higher than the one at -8.3 °C: those are the numbers as certified. The heating range goes down to -30 °C, and the system carries the ENERGY STAR cold climate designation (ID 4663634).

R-32 on a combustion furnace: a built-in safety system

R-32 has a much lower global warming potential than R-410A, but it's classified as mildly flammable. Standards therefore govern how it's installed above a combustion furnace, and the KCAC48HI coil has what it takes to meet them:

  • a refrigerant leak sensor connected to the control board;
  • if a leak is detected, the outdoor unit shuts down, the furnace gas valve closes and the blower starts at high speed to dilute the refrigerant;
  • a separate error code when the sensor reaches the end of its life and needs to be replaced.

This sequence only works if the safety wiring between the coil and the furnace is done correctly. We test it at commissioning, and we check it during maintenance visits.

How the heat pump and furnace share the work

The furnace and the heat pump never heat at the same time; the manufacturer prohibits it for safety reasons. During defrost cycles, the outdoor unit sends a signal to the furnace so it doesn't blow cold air into the house. The inverter-driven twin-cylinder rotary compressor modulates its speed to match demand. In summer, the system cools the whole house through the same ducts. Wi-Fi is available as an option.

What we check before the installation

During a visit in Montréal, Laval, Longueuil, on the North Shore or on the South Shore, we confirm the following points.

The furnace and its blower

With an A-Coil, the furnace blower does all the air distribution work. For a four-ton coil, it has to deliver a high airflow, in cooling as well as in heating, and meet the minimum airflow required with R-32 in the event of a leak. We check the blower's capacity, the condition of the heat exchanger and the control board, and the age of the unit. A furnace that can't keep up is better replaced with the air handler version from the same series.

The electrical supply

The outdoor unit requires a 220 V single-phase supply, an MCA of 39 A and a maximum overcurrent protection (MOP) of 45 A. In a house heated with gas, the electrical panel was often sized without any electric heating load; we run the numbers before confirming that the circuit can be added.

Where the outdoor unit goes

The KU60UXO unit has a vertical format of 35.44 x 13.38 x 49.63 inches, with a published sound level of 62 dB(A). It runs all winter and has to stay above the snow, on a bracket or a stand that lets the defrost water drain. We keep it away from bedroom windows and roof overhangs.

The piping and the drain

The refrigerant connections are 3/8 and 3/4 inch. The coil drain gets a trap and a continuous slope, and the secondary pan is connected when the installation requires it. The vacuum is completed before the valves are opened.

The on-site assessment and the switchover point

We do an on-site assessment of the house's heating needs, room by room, to confirm that four tons is the right choice, then we set the temperature at which the furnace takes over. That setting, more than the spec sheet, is what determines the fuel savings.

LogisVert assistance

The indicative LogisVert amount for this system is $4,224, calculated using the LogisVert rule ($120 per 1,000 BTU/h of certified heating capacity at -8.3 °C); eligibility is confirmed on the installation date. Only Hydro-Québec confirms the assistance granted. The file references are AHRI 217603527 and ENERGY STAR ID 4663634.

Why go with AirGreen

  • Salaried refrigeration technicians, trained in dual-energy wiring and R-32 requirements.
  • Civil liability insurance of $5,000,000.
  • Warranty registration handled by us.
  • After-sales service for maintenance and checks of the safety system.

Ask for your free estimate for the 4-ton Ultranixx with A-Coil: we inspect your furnace, assess the house's heating needs on site and give you a clear quote.

Documentation

Warranty: 12 years on the compressor, 12 years on parts and 6 years on labour, directly from the distributor, on registered models.