KINGHOME Ultranixx R32 Central Heat Pump | 3 Tons - 36,000 BTU | A-Coil
Your central air conditioner has died, but your gas furnace is still good
It's the call we get most often in early summer, from Laval to the South Shore: a cottage's central air conditioner won't start anymore, while the gas furnace in the basement is about ten years younger and works perfectly. Replacing the air conditioner with another air conditioner takes care of summer. Replacing it with a central heat pump takes care of summer and cuts gas consumption for the rest of the year. This 3-ton Ultranixx system, the KU36UXO outdoor unit and the KCAC36FI A-coil, certified together under AHRI 217603525, is designed for exactly this replacement.
What changes compared with a plain air conditioner
On paper, the installation looks like an air conditioner's: a coil on the furnace, a refrigerant line set, an outdoor unit. In practice, three differences matter.
- The outdoor unit works in winter. It has to sit above the snow, on a bracket or a pad, and the defrost water has to drain without forming ice under the unit.
- The coil also becomes a condenser. In heating mode, hot refrigerant flows through the coil sitting on the furnace. The furnace and the heat pump must never heat at the same time, and the control wiring takes that into account.
- The furnace gets new signals. During the outdoor unit's defrost cycle, the control sends a signal to the furnace so it doesn't blow cold air into the house. The coil's leak sensor is also wired to the furnace.
The result is a dual-energy system: the heat pump handles the heating for most of the season and the gas furnace takes over at the changeover point set during commissioning.
Cold-weather capacities
The system is certified at 16 SEER2, 8.5 HSPF2 and an EER2 of 11. The heating capacities listed on NEEP (AHRI No. 217603525) are as follows:
- At -8.3 °C: 26,000 BTU/h, with a COP of 2.0
- At -15 °C: 32,000 BTU/h, with a COP of 1.8
- At -30 °C: 19,600 BTU/h, with a COP of 1.21
At -15 °C, the pairing delivers 89% of its 36,000 BTU/h nominal capacity. At -30 °C, it still heats with a COP above 1. In a dual-energy installation, these figures are used to set the changeover point: as long as the heat pump covers the house's load with a good COP, the furnace stays off. The value at -15 °C is higher than the one at -8.3 °C, as shown on the certificate; that's how the inverter compressor was measured at each test point. The heating range goes down to -30 °C, and the system carries the ENERGY STAR cold climate designation (ID 4497871).
The furnace fan, the centrepiece of the system
With an A-coil, there's no fan in the heat pump's indoor unit: the furnace fan is what moves the air. Its speed has to be set for the airflow a three-ton coil requires, in cooling as well as in heating. A fan set too low means a coil that freezes in summer and reduced capacity in winter. With R-32, the standard also requires a minimum airflow if a leak is detected; we check that the furnace can deliver it.
The KCAC36FI coil
The coil measures 17.50 x 21.25 x 23.00 inches. It connects to the furnace's air outlet and can also be installed horizontally; its electrical box can be moved to suit the available space. It includes an electronic expansion valve, a primary drain pan, a secondary pan and a refrigerant leak sensor. Wi-Fi is available as an option. The outdoor unit's twin-cylinder rotary compressor modulates its speed, which lengthens the cycles and improves dehumidification compared with a basic air conditioner.
What we check before the installation
During a visit in Montréal, Laval or Longueuil, on the North Shore or on the South Shore, we confirm these points before giving you a quote.
The furnace
We look at its age, the condition of the heat exchanger, the fan motor and the dimensions of its air outlet. If the furnace has less fan capacity than the coil requires, or if it's nearing the end of its life, we recommend the air handler version of the same series instead.
The filter and the return air
Every installation must include a filter on the return air, at the coil or at the return grille. We plan an accessible location, because a filter that never gets changed reduces the airflow, makes the coil freeze in summer and lowers the heating capacity in winter.
The power supply
The outdoor unit requires a single-phase 220 V supply, an MCA of 28 A and a maximum overcurrent protection (MOP) of 30 A. We check whether the old air conditioner's circuit matches these values, which isn't always the case.
The outdoor unit location
The KU36UXO unit measures 39.00 x 14.56 x 37.81 inches and its published sound level is 60 dB(A). We often move it from where the old air conditioner stood, to keep it above the snow and out of the path of ice falling from the roof.
The piping and the drain
The connections are 3/8 and 3/4 inch. The old air conditioner's line set is only reused if its diameter and condition allow it, after cleaning. The drain gets a trap and a continuous slope, and the secondary pan is connected when required.
LogisVert assistance
This system has an indicative LogisVert amount of $3,120, calculated using the LogisVert rule ($120 per 1,000 BTU/h of certified heating capacity at -8.3 °C); eligibility is confirmed on the installation date. Only Hydro-Québec confirms the assistance granted. The file references are AHRI 217603525 and ENERGY STAR ID 4497871.
Why go with AirGreen
- Salaried refrigeration technicians who handle the connection, the furnace wiring and the commissioning.
- Civil liability insurance of $5,000,000.
- Warranty registration handled by us.
- After-sales service for maintenance and seasonal adjustments.
Ask for your free estimate for the 3-ton Ultranixx with A-coil: we check your furnace, your panel and your existing line set, then give you a precise quote.
Documentation
- KCAC36FI + KU36UXO spec sheet (English)
- Ultranixx outdoor unit manual (French)
- Ultranixx coil manual (French)
Warranty: 12 years on the compressor, 12 years on parts and 6 years on labour, directly from the distributor, on registered models.